OW_TEMP(4)		     Kernel Interfaces Manual		      OW_TEMP(4)

NAME
     ow_temp -- Dallas Semiconductor 1-Wire Temperature sensor

SYNOPSIS
     device ow_temp

DESCRIPTION
     The ow_temp module supports many of the 1-Wire temperature sensors.

     The sensor is read periodically and the results returned via a sysctl(3) as
     described below.

HARDWARE
     The ow_temp driver supports the following temperature sensors:

     DS1820	1-Wire Digital Thermometer
     DS18S20	High-Precision 1-Wire Digital Thermometer
     DS18B20	Programmable Resolution 1-Wire Digital Thermometer
     DS1822	Econo 1-Wire Digital Thermometer
     DS1825	Programmable Resolution 1-Wire Digital Thermometer with 4-bit ID
     MAX31820	1-Wire, Parasite-Power, Ambient Temperature Sensor

     The driver supports Family codes 0x10, 0x22, 0x28, and 0x3b.

SYSCTL
     The  ow_temp driver reports data via sysctl(8) entries in the device's node
     in the sysctl(8) tree:

     temperature       The last temperature read, in milli-Kelvin.

     badcrc	       The number of CRC errors in reading the temperature  from
		       the  device.   Some  CRC errors are to be expected.  High
		       rates of CRC errors, however, generally indicate a  noisy
		       environment,  cabling  issues, or too many devices on the
		       bus.

     badread	       The number of times a non-CRC error was encountered read-
		       ing the temperature from the card.  This type of error is
		       very rare.

     reading_interval  The time, in ticks, between successive reads of the  sen-
		       sor.

     parasite	       This  item is non-zero when the device is connected using
		       its parasitic power mode.  It can also indicate a  wiring
		       error.

     Temperatures  are	reported in milli-Kelvin, even though the absolute accu-
     racy is around 0.2 degrees for the good devices and  around  1  degree  for
     cheaper  devices.	The devices report in steps of 0.0625 degrees.	The dri-
     ver preserves the precision of the device's measurements in  its  sysctl(8)
     reports.	These devices often have a much higher relative accuracy and re-
     peatability than their absolute accuracy.	This makes them well suited  for
     control  loops  that  strive  for stability and become possible if the full
     precision is preserved.

SEE ALSO
     ow(4), owc(4), sysctl(8), owll(9), own(9)

LEGAL
     1-Wire is a registered trademark of Maxim Integrated Products, Inc.

HISTORY
     The ow_temp driver first appeared in FreeBSD 11.0.

AUTHORS
     The ow_temp device driver and this manual page were written by Warner Losh.

BUGS
     The parasitic mode of the devices does not work.  It requires support  from
     the owc(4) driver that is unimplemented.

     The ID bits from the DS1825 are not recognized or reported.

     The type of the device is not reported via sysctl(8).

     Alarm  mode  is  not supported.  It is not possible to set the low and high
     alarm temperatures.

     There is no way to write to the EEPROM.

     "Convert Temperature" requests are sent directly to the device.   There  is
     no way to use the broadcast ability of the 1-Wire bus to do all the conver-
     sions in parallel.

     It is not possible to set the precision on those devices that support it.

     The  time	to  convert  is  fixed at 1 second, even though some devices are
     faster.

     There is no character device to supply a stream of readings to  a	program.
     Programs interested in the temperature must poll the sysctl to get the tem-
     perature.