COMCONTROL(8)		    System Manager's Manual		 COMCONTROL(8)

NAME
       comcontrol -- control a special tty device

SYNOPSIS
       comcontrol special_device [dtrwait number] [drainwait number]

DESCRIPTION
       The  comcontrol	utility	is used	to examine and modify some of the spe-
       cial characteristics of the specified  tty  device.   If	 no  arguments
       other  than  the	device (or "-" for stdin) are specified, it prints the
       settings	of all controllable characteristics.  This usage requires only
       read access on the device.  Only	the superuser can change the settings.

       The following options are available:

       dtrwait number
	       Set the time to wait after dropping DTR to  the	given  number.
	       The  units are hundredths of a second.  The default is 300 hun-
	       dredths,	i.e., 3	seconds.  This option  needed  mainly  to  set
	       proper recover time after modem reset.

       drainwait number
	       Set the time to wait for	output drain to	the given number.  The
	       units  are  seconds.  The default is 5 minutes, 0 means waiting
	       forever.	 This option needed mainly to specify upper  limit  of
	       minutes to prevent modem	hanging.

       The  standard  way to use comcontrol is to put invocations of it	in the
       /etc/rc.d/serial	startup	script.

FILES
       /dev/ttyd?  dialin devices, hardwired terminals
       /dev/cuau?  dialout devices

SEE ALSO
       stty(1)

HISTORY
       Originally part of cgd's	com package patches, version 0.2.1, to	386BSD
       0.1.   Once  controlled	bidirectional capabilities.  Little is left to
       control now that	these capabilities are standard.

AUTHORS
       Christopher G. Demetriou