LP(4)			    Kernel Interfaces Manual			 LP(4)

NAME
       lp -- printer port Internet Protocol driver

SYNOPSIS
       ifconfig	plip0 myaddress	hisaddress [-link0]

       device ppbus
       device plip
       device ppc

DESCRIPTION
       The  lp driver allows a PC parallel printer port	to be used as a	point-
       to-point	network	interface between two  similarly  configured  systems.
       Data  is	 transferred  4	bits at	a time,	using the printer status lines
       for input: hence	there is  no  requirement  for	special	 bidirectional
       hardware	 and  any standard AT-compatible printer port with working in-
       terrupts	may be used.

       During the boot process,	for each plip device which is probed  and  has
       an interrupt assigned, a	corresponding network device is	created.

       Configuring  an	lp  device  with  ifconfig(8) causes the corresponding
       parallel	port bus to be reserved	for PLIP until the  network  interface
       is configured 'down'.

       The communication protocol is selected by the link0 flag:

       -link0	   (default)  Use FreeBSD mode (LPIP).	This is	the simpler of
		   the two modes and therefore slightly	more efficient.

       link0	   Use Crynwr/Linux compatible mode (CLPIP).  This mode	has  a
		   simulated  Ethernet	packet header, and is easier to	inter-
		   face	to other types of equipment.

       The interface MTU defaults to 1500, but may be set to any value.	  Both
       ends of the link	must be	configured with	the same MTU.

   Cable Connections
       The cable connecting the	two parallel ports should be wired as follows:

	       Pin     Pin     Description
	       2       15      Data0 ->	ERROR*
	       3       13      Data1 ->	SLCT
	       4       12      Data2 ->	PE
	       5       10      Data3 ->	ACK*
	       6       11      Data4 ->	BUSY
	       15      2       ERROR* -> Data0
	       13      3       SLCT   -> Data1
	       12      4       PE     -> Data2
	       10      5       ACK*   -> Data3
	       11      6       BUSY   -> Data4
	       18-25   18-25   Ground

       Cables  with  this wiring are widely available as 'Laplink' cables, and
       are often coloured yellow.

       The connections are symmetric, and provide 5 lines  in  each  direction
       (four data plus one handshake).	The two	modes use the same wiring, but
       make a different	choice of which	line to	use as handshake.

   FreeBSD LPIP	mode
       The signal lines	are used as follows:

       Data0 (Pin 2)	Data out, bit 0.

       Data1 (Pin 3)	Data out, bit 1.

       Data2 (Pin 4)	Data out, bit 2.

       Data3 (Pin 5)	Handshake out.

       Data4 (Pin 6)	Data out, bit 3.

       ERROR* (pin 15)	Data in, bit 0.

       SLCT (pin 13)	Data in, bit 1.

       PE (pin 12)	Data in, bit 2.

       BUSY (pin 11)	Data in, bit 3.

       ACK* (pin 10)	Handshake in.

       When  idle, all data lines are at zero.	Each byte is signalled in four
       steps: sender writes the	4 most significant bits	and raises  the	 hand-
       shake  line;  receiver reads the	4 bits and raises its handshake	to ac-
       knowledge; sender places	the 4 least significant	bits on	the data lines
       and lowers the handshake; receiver reads	the data and lowers its	 hand-
       shake.

       The  packet  format  has	a two-byte header, comprising the fixed	values
       0x08, 0x00, immediately followed	by the IP header and data.

       The start of a packet is	indicated by simply signalling the first  byte
       of  the	header.	  The  end of the packet is indicated by inverting the
       data lines (i.e., writing the ones-complement of	the previous nibble to
       be transmitted) without changing	the state of the handshake.

       Note that the end-of-packet marker assumes that	the  handshake	signal
       and  the	 data-out bits can be written in a single instruction -	other-
       wise certain byte values	in the packet data  would  falsely  be	inter-
       preted  as  end-of-packet.   This  is  not a problem for	the PC printer
       port, but requires care when implementing this protocol on other	equip-
       ment.

   Crynwr/Linux	CLPIP mode
       The signal lines	are used as follows:

       Data0 (Pin 2)	Data out, bit 0.

       Data1 (Pin 3)	Data out, bit 1.

       Data2 (Pin 4)	Data out, bit 2.

       Data3 (Pin 5)	Data out, bit 3.

       Data4 (Pin 6)	Handshake out.

       ERROR* (pin 15)	Data in, bit 0.

       SLCT (pin 13)	Data in, bit 1.

       PE (pin 12)	Data in, bit 2.

       ACK* (pin 10)	Data in, bit 3.

       BUSY (pin 11)	Handshake in.

       When idle, all data lines are at	zero.  Each byte is signalled in  four
       steps:  sender writes the 4 least significant bits and raises the hand-
       shake line; receiver reads the 4	bits and raises	its handshake  to  ac-
       knowledge;  sender places the 4 most significant	bits on	the data lines
       and lowers the handshake; receiver reads	the data and lowers its	 hand-
       shake.  [Note that this is the opposite nibble order to LPIP mode].

       Packet format is:

       Length (least significant byte)
       Length (most significant	byte)
       12 bytes	of supposed MAC	addresses (ignored by FreeBSD).
       Fixed byte 0x08
       Fixed byte 0x00
       <IP datagram>
       Checksum	byte.

       The length includes the 14 header bytes,	but not	the length bytes them-
       selves nor the checksum byte.

       The  checksum  is  a simple arithmetic sum of all the bytes (again, in-
       cluding the header but not checksum or length bytes).   FreeBSD	calcu-
       lates outgoing checksums, but does not validate incoming	ones.

       The  start of packet has	to be signalled	specially, since the line cho-
       sen for handshake-in cannot be used  to	generate  an  interrupt.   The
       sender  writes  the value 0x08 to the data lines, and waits for the re-
       ceiver to respond by writing 0x01 to its	data lines.  The  sender  then
       starts signalling the first byte	of the packet (the length byte).

       End  of	packet	is deduced from	the packet length and is not signalled
       specially (although the data lines are restored to the zero, idle state
       to avoid	spuriously indicating the start	of the next packet).

SEE ALSO
       ppbus(4), ppc(4), ifconfig(8)

BUGS
       Busy-waiting loops are used while handshaking bytes, (and  worse	 still
       when  waiting  for  the receiving system	to respond to an interrupt for
       the start of a packet).	Hence a	fast system talking to a slow one will
       consume excessive amounts of CPU.  This is unavoidable in the  case  of
       CLPIP mode due to the choice of handshake lines;	it could theoretically
       be improved in the case of LPIP mode.

       Polling timeouts	are controlled by counting loop	iterations rather than
       timers, and so are dependent on CPU speed.  This	is somewhat stabilised
       by the need to perform (slow) ISA bus cycles to actually	read the port.

FreeBSD	14.3			 March 4, 1996				 LP(4)