VM-BHYVE(8)		    System Manager's Manual		   VM-BHYVE(8)

NAME
       vm -- utility to	manage bhyve virtual machines

SYNOPSIS
       vm version
       vm init

       vm get all [setting] [...]
       vm set setting=value [...]

       vm switch list
       vm switch info [name] [...]
       vm  switch  create  [-t	type]  [-i interface] [-n vlan-id] [-b bridge]
	  [-m mtu] [-a address]	[-p] name
       vm switch vlan name vlan-id
       vm switch nat name on|off
       vm switch address name a.b.c.d/xx|none
       vm switch private name on|off
       vm switch add name interface
       vm switch remove	name interface
       vm switch destroy name

       vm datastore list
       vm datastore add	name spec
       vm datastore remove name
       vm datastore iso	name path

       vm create [-d datastore]	[-t template] [-s size]	[-c vCPUs] [-m memory]
	  [-i vm-image]	[-C -k pubkeys]	[-n netconfig] name
       vm destroy [-f] name
       vm list [-rv]
       vm info [name] [...]
       vm install [-fi]	name iso
       vm start	[-fi] name ...
       vm stop name ...
       vm restart name
       vm suspend name ...
       vm discard [-f] name
       vm console [-w] name [com1|com2]
       vm rename name new-name
       vm add [-d device] [-t type] [-s	size|switch] name
       vm reset	[-f] name
       vm poweroff [-f]	name
       vm startall
       vm stopall [-f]
       vm suspendall [-f]
       vm configure name [meta-data|network-config|user-data]
       vm edit name [meta-data|network-config|user-data]
       vm passthru
       vm clone	name[@snapshot]	new-name
       vm snapshot [-f]	name|name@snapshot
       vm rollback [-r]	name@snapshot
       vm migrate [-s12t] [-r name] [-i	snapshot] [-d datastore] guest host

       vm iso [-d datastore] [url]
       vm img [-d datastore] [url]

       vm image	list
       vm image	create [-d description]	[-u] name
       vm image	provision [-d datastore] uuid new-name
       vm image	destroy	uuid

DESCRIPTION
       The vm utility is used to provide  simplified  management  of  bhyve(8)
       virtual machines, including networking and console access.

       Networking  is  handled by creating one or more virtual switches.  Each
       switch has a simple name	which is referenced  in	 the  virtual  machine
       configuration  file.   The vm utility automatically creates a bridge(4)
       device for each virtual switch and assigns virtual machine  tap(4)  in-
       terfaces	dynamically.

       All  configuration  for virtual machines	is stored in a simple rc style
       configuration file.  When virtual machines are first created, the  con-
       figuration file is copied from a	template which can be specified	by the
       user.   Multiple	templates can be created providing an easy way to pro-
       vision guests with specific configurations.

       vm gracefully handles reboot and	 shutdown  commands  from  inside  the
       guests,	whilst	providing  full	management of the virtual machine from
       the host	system.

BASIC SETUP
       Once vm is installed, create the	directory which	will store  your  vir-
       tual  machine  configuration and	data.  This directory will be referred
       to as $vm_dir throughput	this man page.

       Add the following into /etc/rc.conf

	     vm_enable="YES"
	     vm_dir="/your/vm/path"
	     vm_list=""
	     vm_delay="5"

       The first and second lines are  required	 to  enable  the  vm  utility.
       Please  see the startall	subcommand description for more	information on
       the third and fourth settings.

       Now run the vm init subcommand to  finish  initialisation.   This  will
       create  subdirectories  inside  $vm_dir	to hold	configuration and tem-
       plates.	It will	also load any required kernel modules.	 This  subcom-
       mand  needs  to	be  run	on each	boot, which is normally	handled	by the
       rc.d script.

       Sample templates	are installed to  /usr/local/share/examples/vm-bhyve/.
       You can make use	of these by copying them into your $vm_dir/.templates/
       directory.   You	 can create and	edit the templates as required.	 It is
       recommended to keep a template called default.conf,  as	this  will  be
       used when no template is	manually specified.

ZFS
       If you are using	a ZFS dataset to store your virtual machines, and want
       a new child dataset created for each one, specify the dataset to	use in
       /etc/rc.conf as follows:

	     vm_dir="zfs:pool/dataset"

       In  contrast  to	earlier	versions, if $vm_dir is	a normal path, a stan-
       dard subdirectory will be created for each virtual machine,  regardless
       of  the file system type.  However, vm is now able to handle situations
       where the dataset mountpoint does not match the dataset name.

QUICKSTART
       Create a	virtual	switch called public (which is the switch name	speci-
       fied  in	the default templates) and attach it to	a real interface.  Use
       your own	interface in place of em0 as required.

	    # vm switch	create public
	    # vm switch	add public em0

       Download	an ISO file to use for installation:

	    # vm iso ftp://ftp.freebsd.org/pub/FreeBSD/releases/ISO-IMAGES/10.1/FreeBSD-10.1-RELEASE-amd64-disc1.iso

       Create a	new guest using	the default template and disk size, then start
       the installation.  The install subcommand will immediately  return  you
       to  your	shell.	Once started, use the console subcommand to connect to
       the guest and complete the installation.

	    # vm create	my-guest
	    # vm install my-guest FreeBSD-10.1-RELEASE-amd64-disc1.iso
	    # vm console my-guest

       Please	note	that	Linux	 guests	   currently	require	   the
       sysutils/grub2-bhyve package to be installed.  This is used in place of
       bhyveload(8) to load the	guest kernel into memory.

WINDOWS	SUPPORT
       Windows guests are supported on versions	of FreeBSD that	have UEFI sup-
       port  in	 bhyve(8).  As of April	2016, UEFI support should be available
       in FreeBSD 10.3-RELEASE and FreeBSD 11-CURRENT.

       You will	also need a copy of the	UEFI firmware.	This can either	be in-
       stalled using the sysutils/edk2 port, or	you can	 manually  download  a
       copy  (see  URL below) to $vm_dir/.config/BHYVE_UEFI.fd and configure a
       guest to	use it by setting loader="uefi-custom".

       If you are running FreeBSD 10 , there is	no VGA	console	 in  bhyve(8),
       and  so an unattended installation ISO is required which	allows Windows
       to install and boot without any	user  interaction.   Instructions  for
       creating	a suitable ISO can be found at the URL below.

       On  FreeBSD 11, VGA access can be enabled by setting the	graphics="yes"
       option in the guest configuration file.	Once the  guest	 has  started,
       vnc  IP & port details can be seen in vm	list output.  See the configu-
       ration format documentation below for more detailed information on con-
       figuring	graphics.  If network drivers are required,  I	recommend  re-
       running	the  vm	 install subcommand once the guest has been installed,
       but providing an	ISO of the virtio-net drivers instead.

       Once the	installation ISO is ready, has been placed in the $vm_dir/.iso
       directory, and you have the UEFI	firmware,  installation	 can  be  per-
       formed as normal.

	     # vm create -t windows -s 30G winguest
	     # vm install winguest win_repack.iso

       Windows installation has	been tested with 2012r2	and takes around 20-25
       minutes.	  During  install,  the	guest will reboot twice	(three runs in
       total).	You can	 see  the  guest  reboot  by  watching	the  log  file
       $vm_dir/guestname/vm-bhyve.log.	 The  third run	should boot fully into
       Windows.	 The virtio network adapter will request an IP	address	 using
       DHCP.   Connect	to the guest console and press i to see	the IP address
       that has	been assigned.	 The  default  unattended  installation	 files
       should  make  RDP available, using Administrator	and Test123 as the de-
       fault login details.

       A pre-compiled copy of the UEFI firmware	 (BHYVE_UEFI_20160526.fd),  as
       well  as	 instructions  for creating an unattended installation ISO can
       currently		be		  obtained		  from
       https://people.freebsd.org/~grehan/bhyve_uefi/

SUBCOMMANDS
       version
	       Show the	version	number of vm-bhyve installed.

       init
	       This  should  be	run once after each host reboot	before running
	       any other vm subcommand.	 The main function of the init subcom-
	       mand is as follows:

	       o Load all necessary kernel modules if not already loaded
	       o Set tap devices to come up automatically when opened
	       o Create	any configured virtual switches

       get all|setting
	       Get a global configuration setting.  These  are	settings  that
	       affect  the  functionality of vm-bhyve, such as configuring the
	       type of serial console to use.  The keyword all can be used  to
	       retrieve	all user configurable settings,	or you can specify one
	       or more settings	by name, separated by a	space.

       set setting=value
	       Sets  the  value	 of  a global configuration setting.  Multiple
	       settings	can be changed at the  same  time  by  seperating  the
	       setting=value pairs with	a space.

	       These settings are stored in $vm_dir/.config/system.conf

       switch list
	       List  virtual  switches.	  This	reads  all  configured virtual
	       switches	from  the  $vm_dir/.config/switch  file	 and  displays
	       them.   If  the	virtual	 switches are loaded, it also tries to
	       display the bridge(4) interface that has	been assigned to  each
	       one.

       switch info [name [...]]
	       This  subcommand	shows detailed information about the specified
	       virtual switch(es).  If no switch names are provided,  informa-
	       tion  is	 output	for all	configured switches.  Information dis-
	       played includes the following:

	       o Basic switch settings
	       o Overall bytes sent and	received via this switch
	       o Physical ports	connected
	       o Virtual ports,	including the associated virtual machine

       switch create [-t type] [-i interface] [-n  vlan-id]  [-b  bridge]  [-m
	       mtu] [-a	address] [-p] name
	       Create a	new virtual switch.  The name must be supplied and may
	       only  contain letters, numbers and dashes.  However, it may not
	       contain a dash at the beginning or end.	Note that the  maximum
	       length  of  a switch name is also limited to 12 characters, due
	       to the way we use this as the interface name.

	       There are currently 4 types of virtual switch that can be  cre-
	       ated.   These  are  standard, manual, netgraph, vale and	vxlan.
	       The default type	is standard, which creates a  basic  bridge(4)
	       interface  and bridges clients to it.  manual allows you	to at-
	       tach guests to a	bridge that you	have  created  and  configured
	       manually.   netgraph switches use the netgraph ng_bridge	system
	       to create a virtual switch connecting  guests.	vale  switches
	       use  the	netmap VALE system to create a virtual switch connect-
	       ing guests.  vxlan allows you to	create virtual	LANs  (similar
	       to a VLAN) which	tunnel L2 guest	traffic	over L3.

	       -t type	     The type of virtual switch	to create.  The	avail-
			     able  types  are  listed above.  This defaults to
			     standard if not specified.

	       -i interface  For standard and vxlan switches you can attach  a
			     physical interface	at creation time.  This	option
			     is	required for vxlan switches.

	       -n vlan-id    Allows  you to specify a VLAN ID for standard and
			     vxlan switches.   This  option  is	 required  for
			     vxlan switches.

	       -b bridge     If	 creating  a  manual  switch using an existing
			     bridge on your system, this option	allows you  to
			     specify  the  name	 of  the  bridge interface you
			     would like	to use.	 This option is	 required  for
			     manual switches.

	       -m mtu	     Specify an	mtu to use for the bridge interface.

	       -a address    This  allows you to specify an IP address that is
			     assigned to the bridge interface.	This should be
			     specified in a.b.c.d/prefix-len CIDR notation.

	       -p	     Use this option to	create a private  switch.   If
			     this  is  enabled,	no traffic will	be allowed be-
			     tween guests on the  same	switch,	 however  then
			     will all be able to communicate with any physical
			     interfaces	added to the switch.

       switch vlan name	vlan-id
	       Assign a	VLAN number to a virtual switch.  The VLAN number must
	       be between 0-4094.

	       When  adding  an	 interface to a	VLAN enabled virtual switch, a
	       new vlan(4) interface is	created.  This interface has the rele-
	       vant parent interface and VLAN tag configured.  This  vlan  in-
	       terface	is  then  added	 to  the virtual switch.  As such, all
	       traffic between guests on the same switch is untagged and trav-
	       els freely.  However, all traffic exiting via  physical	inter-
	       faces is	tagged.

	       If the virtual switch already has physical interfaces assigned,
	       they  are  all  removed from the	bridge,	reconfigured, then re-
	       added.

	       To remove the VLAN configuration	from a virtual switch, specify
	       a vlan-id of 0.

       switch address name a.b.c.d/xx|none
	       Configure an IP address for the specified virtual switch.   The
	       address should be specified in CIDR notation.  To remove	an ad-
	       dress, specify none in place of the address.

	       If  NAT	functionality is required, please configure an address
	       on the switch to	become the gateway address for guests.	Source
	       NAT rules can then be created using your	choice of firewall  or
	       NAT  daemon.   If  DHCP is desired, we recommend	using a	manual
	       switch and configuring this by hand.

       switch private name on|off
	       Enable of disable private mode for a virtual switch.   In  pri-
	       vate  mode,  guests  will  only be able to communicate with the
	       physical	interface(s), not with each other.

	       Please note that	changing this setting does not	affect	guests
	       that  are  already  running,  but will be applied to any	guests
	       started from cold-boot thereafter.

       switch add name interface
	       Add the specified interface to the named	virtual	switch.

	       The interface will immediately be added to the relevant	bridge
	       if  possible, and stored	in the persistent switch configuration
	       file.  If a vlan-id is specified	on the	virtual	 switch,  this
	       will cause a new	vlan(4)	interface to be	created.

       switch remove name interface
	       Removes	the  specified interface from the named	virtual	switch
	       and updates the persistent configuration	file.

       switch destroy name
	       Completely remove the named virtual switch and  all  configura-
	       tion.   The  associated bridge(4) interface will	be removed, as
	       well as any vlan(4) interfaces if they are not in use by	 other
	       virtual switches.

       datastore list
	       List  the  configured datastores.  Normally vm-bhyve will store
	       all guests under	the directory specified	in /etc/rc.conf.  This
	       is the default datastore.  Additional datastores	can be	added,
	       providing  the ability to store guests in multiple locations on
	       your system.

       datastore add name spec
	       Add a new datastore to the system.  The datastore name can only
	       contain letters,	numbers	and _. characters.   The  spec	should
	       use  the	 same  format as $vm_dir.  A standard directory	can be
	       specified by just providing the path, whereas a ZFS storage lo-
	       cation should be	specified in zfs:pool/dataset format.

	       Please note that	the directory or dataset should	already	exist.
	       We do not try to	create it.

       datastore remove	name
	       Remove the specified datastore from the list.   This  does  not
	       destroy the directory or	dataset, leaving all files intact.

       datastore iso name path
	       Adds  a	new  datastore location	for storing iso	files.	Guests
	       cannot be created in an iso store, but this  provides  an  easy
	       way  to configure vm-bhyve to look in any arbitrary location on
	       your system (or mounted network share) where you	 may  want  to
	       store iso images.

       create [-d datastore] [-t template] [-s size] name
	       Create a	new virtual machine.

	       Unless  specified, the default.conf template will be used and a
	       20GB virtual disk image is created.  This subcommand will  cre-
	       ate the virtual machine directory $vm_dir/$name,	and create the
	       configuration file and empty disk image within.

	       -d datastore  Specify  the datastore to create this virtual ma-
			     chine  under.   If	 not  specified,  the  default
			     dataset will be used, which is the	location spec-
			     ified in /etc/rc.conf.

	       -t template   Specifies	the  template  to  use from within the
			     $vm_dir/.templates	directory.  The	 .conf	suffix
			     should not	be included.

	       -s size	     The  size	of disk	image to create	in bytes.  Un-
			     less specified, the guest image will be a	sparse
			     file 20GB in size.

       destroy name
	       Removes the specified virtual machine from the system, deleting
	       all associated disk images & configuration.

       list [-rv]
	       List  all  the virtual machines in the $vm_dir directory.  This
	       will show the basic configuration for each virtual machine, and
	       whether they are	currently running.  Using the -v  option  dis-
	       plays additional	information about each virtual machine.

	       If the -r option	is specified, only running guests are listed.

       info [name [...]]
	       Shows  detailed	information  about  the	 specified virtual ma-
	       chine(s).  If no	names are given, information for  all  virtual
	       machines	is displayed.

	       This  output  includes  detailed	 information about network and
	       disk devices, including the space usage for all	virtual	 disks
	       (excluding  custom disk devices).  If the guest is running, the
	       output also shows the amount of host memory currently  in  use,
	       and  additional	network	 details including bytes sent/received
	       for each	virtual	interface.

       install [-fi] name iso
	       Start a guest installation for the named	virtual	machine, using
	       the specified ISO file or install disk image.  The iso argument
	       should be the filename of an ISO	or image  file	already	 down-
	       loaded  into  the  $vm_dir/.iso	directory (or any media	datas-
	       tore), a	full path, or a	file in	the  current  directory.   ISO
	       files in	the default .iso store can be downloaded using the iso
	       subcommand described below.

	       By  default the installation is started in the background.  Use
	       the console subcommand to connect and begin the installation.

	       After installation, the guest can be rebooted and will  restart
	       using  its own disk image to boot.  At this point the installa-
	       tion ISO	file is	still attached,	allowing you to	use the	CD/DVD
	       image for any post installation tasks.  The ISO file  will  re-
	       main  attached  after  each  reboot  until  the	guest is fully
	       stopped.

	       If the -f option	is specified, the guest	will be	started	in the
	       foreground on stdio.  The -i option starts the guest in	inter-
	       active  mode.   If the global console setting must be set like-
	       wise.  In interactive mode the guest is started on a foreground
	       tmux session, but this can be detached using the	standard  tmux
	       commands.

       start [-fi] name	...
	       Start  the  named virtual machine(s).  The guests will boot and
	       run completely in the background.  Use the  console  subcommand
	       to connect to it	if required.

	       For  each network adapter specified in the guest	configuration,
	       a tap(4)	interface will be created.  If possible, the  tap  in-
	       terface	will  be  attached  the	 relevant bridge(4) interface,
	       based on	the virtual switch specified in	the  guest  configura-
	       tion.

	       If the -f option	is specified, the guest	will be	started	in the
	       foreground on stdio.

	       The  -i	option	starts	the guest in interactive mode.	If the
	       global console setting is set to	tmux, the guest	is started  on
	       a  foreground  tmux session, but	this can be detached using the
	       standard	tmux commands.	Otherwise, the guest is	started	in the
	       background, and cu(1) is	launched to connect to the console.

	       Both the	-f option and -i option	are ignored when attempting to
	       start more than one VM.

       stop name ...
	       Stop a named virtual machine.  All tap(4) and  nmdm(4)  devices
	       will be automatically cleaned up	once the guest has exited.

	       If  a guest is stuck in the bootloader stage, you are given the
	       option to forcibly stop it.

	       Multiple	guests can be specified	to this	command	 at  the  same
	       time.  Each one will be sent a poweroff event.

       restart name
	       Attempt to restart the specified	guest.	This causes a shutdown
	       event  to  be sent to the guest,	however, vm-bhyve will restart
	       the guest rather	than stopping completely.

	       A benefit of using this function	is that	vm-bhyve will not  de-
	       stroy  and  recreate  network  devices like it would when using
	       stop/start.  Note that guest configuration is not re-loaded, so
	       all guest settings will be as they  were	 when  the  guest  was
	       originally started.

       suspend name ...
	       Stop  the named virtual machine(s) while	retaining their	state.
	       The memory contents of the virtual machine(s) are saved in  the
	       datastore.   When  resumed,  the	operating systems and applica-
	       tions are restored to the exact state they were in before  sus-
	       pension.

	       To  resume  a  suspended	virtual	machine, use the start subcom-
	       mand.  It will automatically detect whether the virtual machine
	       is suspended and	resume it.

	       This feature is still experimental as of	September 2025 and re-
	       quires the FreeBSD FreeBSD kernel and userland  to  be  rebuilt
	       with BHYVE_SNAPSHOT option.

       discard [-f] name
	       Discard the saved state files of	the virtual machine.  This op-
	       eration is equivalent to	a forced power-off from	the guest, and
	       any unsaved files may be	lost.

	       If  the -f option is specified, the state files will be removed
	       without prompting for confirmation.

       console [-w] name [com1|com2]
	       Connect to the console of the named virtual  machine.   Without
	       network	access,	 this  is the primary way of connecting	to the
	       guest once it is	running.

	       By default this will connect to the first com port specified in
	       the client configuration, which is usually com1.	 Alternatively
	       you can specify the com port to connect to.

	       This looks for the nmdm(4) device associated with  the  virtual
	       machine,	 and  connects to it with cu(1).  Use ~+Ctrl-D to exit
	       the console and return to the host.

	       If the -w option	is specified, wait until the  virtual  machine
	       starts before connecting	to the console.

       rename name new-name
	       Renames	the  specified	virtual	 machine.   The	 guest must be
	       stopped or suspended to use this	function.

       add [-d device] [-t type] [-s size|switch] name
	       Add a new network or disk device	to the named virtual  machine.
	       The options depend on the type of device	that is	being added:

	       -d device	The type of device to add.  Currently this can
				either be disk or network

	       -t type		For  disk  devices, this specifies the type of
				disk device to create.	Valid options for this
				are zvol, sparse-zvol and file.	 If not	speci-
				fied, this defaults to file.

	       -s size|switch	For disk devices, this is used to specify  the
				size of	the disk image to create.  For network
				devices,  use  this option to specify the vir-
				tual switch to connect the  network  interface
				to.

	       For both	types of device, the emulation type will be chosen au-
	       tomatically  based on the emulation used	for the	existing guest
	       devices.

       reset [-f] name
	       Forcefully reset	the named virtual  machine.   This  can	 cause
	       corruption  to the guest	file system just as with real hardware
	       and should only be used if necessary.

       poweroff	[-f] name
	       Forcefully power	off the	named virtual machine.	As with	 reset
	       above,  this  does  not inform the guest	to shutdown gracefully
	       and should only be used if the guest can	not be shut down using
	       normal methods.

       startall
	       Start all virtual machines  configured  for  auto-start.	  This
	       subcommand is used by the rc.d scripts to start all machines on
	       boot.

	       The  list  of  virtual  machines	 should	be specified using the
	       $vm_list	variable in /etc/rc.conf.   This  allows  you  to  use
	       shared  storage	for  virtual  machine data, whilst making sure
	       that the	correct	guests are started automatically on each host.
	       (Or to just make	sure your required guests start	on boot	whilst
	       leaving test/un-needed guests alone)

	       The  delay  between  starting  guests  can  be  set  using  the
	       $vm_delay  variable,  which defaults to 5 seconds.  Too small a
	       delay can cause problems, as each  guest	 doesn't  have	enough
	       time to claim a null modem device before	the next guest starts.
	       Increasing  this	value can be useful if you have	disk-intensive
	       guests and want to give each guest a chance to fully  boot  be-
	       fore the	next starts.

       stopall [-f]
	       Stop  all  running virtual machines.  This sends	a stop command
	       to all bhyve(8) instances,  regardless  of  whether  they  were
	       starting	using or not.

	       If  the	-f  option  is specified, all instances	are stopped in
	       parallel.

       suspendall [-f]
	       Suspend all running machines.  Unlike  stopall,	this  sends  a
	       suspend command to the instances	started	by vm-bhyve.

	       If  the	-f option is specified,	all instances are suspended in
	       parallel.

       configure name [meta-data|network-config|user-data]
	       The configure subcommand	simply opens the virtual machine  con-
	       figuration  file	in your	default	editor,	allowing you to	easily
	       make changes.  Please note, changes do not  take	 effect	 until
	       the virtual machine is fully shutdown and restarted.

	       If  a  second  argument is given, it opens the specified	cloud-
	       init configuration file in the default editor.

       edit name [meta-data|network-config|user-data]
	       An alias	to the configure subcommand.

       passthru
	       The passthru subcommand lists all PCI devices  in  the  system,
	       the  device  ID	required  for bhyve, and whether the device is
	       currently ready to be used by a guest.  In order	to make	a  de-
	       vice  ready,  it	needs to be reserved on	boot by	adding the de-
	       vice ID to the pptdevs variable in /boot/loader.conf.

	       Once a device is	ready, it can be assigned to a guest by	adding
	       passthruX="{ID}"	to the guest's configuration file.   X	should
	       be an integer starting at 0 for the first passthrough device.

	       More details can	be found in the	bhyve wiki.

       clone name[@snapshot] new-name
	       Create  a  clone	 of the	virtual	machine	name, as long as it is
	       currently  powered  off.	  The  new  machine  will  be	called
	       new-name,  and will be ready to boot with a newly assigned UUID
	       and empty log file.

	       If no snapshot name is given, a new snapshot will be  taken  of
	       the guest and any descendant datasets or	ZVOLs.	If you wish to
	       use  an	existing  snapshot as the source for the clone,	please
	       make sure the snapshot exists  for  the	guest  and  any	 child
	       ZVOLs, otherwise	the clone will fail.

	       Please note that	this function requires ZFS.

       snapshot	[-f] name|name@snapshot
	       Create  a  snapshot of the names	virtual	machine.  This subcom-
	       mand is only supported with ZFS and will	take a snapshot	of the
	       guest dataset and any descendant	ZVOL devices.

	       The guest and snapshot name can	be  specified  in  the	normal
	       name@snapshot  way  familiar to ZFS users.  If no snapshot name
	       is given, the snapshot is based on  the	current	 timestamp  in
	       Y-m-d-H:M:S format.

	       By  default  the	guest must be stopped to use this command, al-
	       though you can force a snapshot of a running guest by using the
	       -f option.

       rollback	[-r] name@snapshot
	       Rollback	the guest to the specified snapshot.  This  will  roll
	       back the	guest dataset and all descendant ZVOL devices.

	       Normally,  ZFS will only	allow you to roll back to the most re-
	       cent snapshot.  If the snapshot given is	not the	 most  recent,
	       ZFS  will  produce a warning detailing that you need to use the
	       -r option to remove the more recent snapshots.	It  will  also
	       produce	a  list	of the snapshots that will be destroyed	if you
	       use this	option.	 The -r	option can be passed directly into  vm
	       rollback

	       The guest must always be	stopped	to use this command.

       migrate [-s12t] [-r name] [-i snapshot] [-d datastore] guest host
	       The  migrate  subcommand	 allows	 transferring a	guest from one
	       host to another.	 Note that currently  this  involves  shutting
	       down  the guest,	and optionally restarting it once migration is
	       complete.

	       The migration process uses ssh, and works best if key-based ssh
	       is enabled between your hosts  without  the  requirement	 of  a
	       password.  Transfer is still possible using a password, but you
	       will  be	 prompted  for	this several times during the transfer
	       process.

	       Firstly a full snapshot of the guest is sent while the guest is
	       still running.  Optionally, an intermediate  incremental	 snap-
	       shot  can  then be sent to bring	the remote guest up to date if
	       it is expected that the full send may take a long time, or that
	       a large amount of data may change during	this time.   Once  the
	       remote  end  is reasonably up to	date, the guest	is powered off
	       so a final incremental snapshot can be sent.

	       -r name	     Allows the	remote guest to	be given  a  different
			     name to the source.

	       -d datastore  Specify  the  datastore to	store the guest	on the
			     destination host.

	       -s	     Start the guest on	the remote host	once migration
			     is	complete.

	       -1	     Run only the first	stage of migration.  This will
			     take a full snapshot of the local guest and  send
			     it	to the destination host.

	       -2	     Run  only	the second stage.  This	will second an
			     incremental snapshot and then complete the	migra-
			     tion.  This requires the -i parameter to  specify
			     the source	snapshot.

	       -t	     Triple snapshot mode.  This will send both	a full
			     snapshot,	and  one  incremental, before shutting
			     the guest down  and  doing	 a  final  incremental
			     send.   This  may	be  useful  for	 large or busy
			     guests where there	could be  a  large  number  of
			     changes  during  the initial full send.  The idea
			     is	that the first incremental send	will bring the
			     remote guest nearly up to date,  sending  changes
			     that  have	 occurred  during  the lengthy initial
			     full send.	 This should reduce the	 size  of  the
			     final  incremental	send, minimising the amount of
			     time the guest is powered off.

	       -x	     Destroy the local guest  once  the	 migration  is
			     complete.

	       -i snapshot   When  running the second stage of migration, this
			     parameter is used to  specify  the	 name  of  the
			     snapshot  to  base	the incremental	send on.  This
			     snapshot must exist on both hosts.

       iso [-d datastore] [url]
	       List all	the ISO	files currently	stored in the $vm_dir/.iso di-
	       rectory.	 This is often useful during guest  installation,  al-
	       lowing you to copy and paste the	ISO filename.

	       If  a  url  is  specified, instead of listing ISO files,	it at-
	       tempts to download the given file using fetch(1)	to the default
	       datastore.  The target datasource can be	changed	by  specifying
	       -d datastore with url.

       img [-d datastore] [url]
	       List   all  the	cloud-init  images  currently  stored  in  the
	       $vm_dir/.img directory.	This is	often useful during guest  in-
	       stallation, allowing you	to copy	and paste the image filename.

	       If  a  url is specified,	instead	of listing the image files, it
	       attempts	to download the	given file using fetch(1) to  the  de-
	       fault datastore.	 The target datastore can be changed by	speci-
	       fying -d	datastore with url.

       image list
	       List  available	images.	  Any  virtual machine can be packaged
	       into an image, which can	then be	used to	create additional  ma-
	       chines.	 All  images have a globally unique ID (UUID) which is
	       used to identify	them.  The list	subcommand shows the UUID, the
	       original	machine	name, the date it was created and a short  de-
	       scription of the	image.

	       Please  note  that these	subcommands rely on using ZFS features
	       to package/unpackage the	images,	and as such are	only available
	       when using a ZFS	dataset	as the storage location.

       image create [-d	description] [-u] name
	       Create a	new image from the named virtual machine.   This  will
	       create  a  compressed copy of the original guest	dataset, which
	       is stored in the	$vm_dir/images directory.  It also  creates  a
	       UUID.manifest file which	contains details about the image.

	       Once complete, it will display the UUID which has been assigned
	       to this image.

	       If  you	do not want the	image to be compressed,	specify	the -u
	       option.

       image provision [-d datastore] uuid new-name
	       Create a	new virtual machine, named new-name, from  the	speci-
	       fied image UUID.	 This will be created on the default datastore
	       unless specified	otherwise.

       image destroy uuid
	       Destroy the specified image.

GLOBAL CONFIGURATION
       These  configuration options are	stored in $vm_dir/.config/system.conf,
       and affect the global functionality of vm-bhyve.	 These settings	can be
       changed by either editing the configuration file	manually, or using the
       vm set and vm get commands.

       console		  Set the type of console to use,  which  defaults  to
			  nmdm.	 If you	have the tmux port installed and would
			  prefer to use	that for guest console access, you can
			  set this option to tmux.

GUEST CONFIGURATION FORMAT
       Each  virtual machine has a configuration file that specifies the hard-
       ware configuration.  This uses a	similar	format to the rc files,	making
       them easy to edit by hand.  The settings	for each guest are  stored  in
       $vm_dir/$vm_name/$vm_name.conf.	 An overview of	the available configu-
       ration options is listed	below.

       loader		  This option sets the loader to use for a  guest  and
			  must be specified.  The valid	options	are bhyveload,
			  grub,	uefi, uefi-csm,	or uefi-custom.

       uefi_vars	  Setting  this	option to a true value allows the per-
			  sistent storage of UEFI variables.  This may be  re-
			  quired for some guests that install boot firmware to
			  a  non-standard  location and	rely on	UEFI variables
			  to locate it.	  The  version	of  uefi-firmware  in-
			  stalled  must	 provide  the  template	data file, and
			  support also needs to	be present in bhyve

       bhyveload_loader	  This option allows a custom path to be used for  the
			  loader  inside the guest.  Passed to bhyveload using
			  the -l argument.

       bhyveload_args	  This option allows extra arguments to	be  given  for
			  the  loader  inside the guest.  Appended verbatim to
			  the bhyveload	command	line.

       loader_timeout	  By default the bhyveload and grub loaders will  wait
			  for 3	seconds	before booting the default option.  If
			  access  to  the  grub	console	is needed, this	can be
			  increased to give more time to connect to  the  con-
			  sole.	  If  access  to  the  grub console is not re-
			  quired, it can also be reduced to speed  up  overall
			  boot.

       cpu_sockets	  Specify the number of	CPU sockets that should	be ex-
			  posed	 to the	guest.	The product of sockets * cores
			  * threads should equal the number of cpus  that  has
			  been	configured.  The ability to control CPU	topol-
			  ogy on a per-guest  basis  requires  FreeBSD	12  or
			  newer.  On older systems, there are vmm sysctl vari-
			  ables	 available  to	configure these	settings glob-
			  ally.

       cpu_cores	  The number of	cores to create	per CPU	socket.

       cpu_threads	  The number of	threads	to create per CPU core.

       memory		  The amount of	memory to assign to the	 guest.	  This
			  can be specified in megabytes	or gigabytes using the
			  M and	G suffixes.

       wired_memory	  Set  this  to	 yes  in  order	 to have the requested
			  amount of memory wired to the	guest.

       hostbridge	  This option allows you to specify the	type of	 host-
			  bridge  used	for  the guest hardware.  Normally you
			  can leave this as default, which is to use  a	 stan-
			  dard bhyve hostbridge.

			  There	 are  two other	options.  amd, which is	almost
			  identical to the standard hostbridge,	but advertises
			  itself with a	vendor ID of AMD.  There are also some
			  special cases	where you may require no hostbridge at
			  all, which can be achieved using the none value.

       fwcfg		  This option allows you to specify the	 fwcfg	inter-
			  face.	 The valid options are bhyve, or qemu.

       comports		  This option allows you to specify which com ports to
			  create  for  the  guest.  The	default	is to create a
			  single com1 port.  Valid values for  this  are  com1
			  and  com2.   You  can	 also connect two com ports by
			  specifying both, separated by	a space.

       utctime		  As of	version	1.2, vm-bhyve defaults to yes for this
			  option.  This	causes bhyve to	try and	set the	guests
			  RTC clock to UTC rather than	the  host's  time.   I
			  consider  this  more	consistent, and	should produce
			  the correct time in the guest	as long	as  the	 time-
			  zone	is  correctly  set.  Additionally, some	guests
			  actually expect a UTC	realtime clock.

			  If you require bhyve to use the host's time,	as  it
			  would	by default, explicitly set this	to no.

       debug		  If  this is set to yes, all output from the bhyve(8)
			  process	will	   be	     written	    to
			  ${vm_dir}/guest/bhyve.log.   This  is	useful for de-
			  bugging purposes as it allows	you to see  any	 error
			  messages that	are being produced by bhyve(8) itself.

       network0_type	  The  emulation to use	for the	first network adapter.
			  This option can be unspecified if no guest  network-
			  ing  is required.  The recommended value for this is
			  virtio-net.  Additional network  interfaces  can  be
			  configured  by  adding  additional networkX_type and
			  networkX_switch values, replacing X  with  the  next
			  available integer.

       network0_switch	  The  virtual switch to connect interface 0 to.  This
			  should correspond to a virtual switch	created	 using
			  the  vm  switch  create  subcommand.	If the virtual
			  switch is not	found, an interface will still be  as-
			  signed, but not connected to any bridge.

			  Note that this field is no longer strictly required.
			  If  you are using a custom device for	the networking
			  that is already configured, you may not need the in-
			  terface connected to	a  virtual  switch.   See  the
			  network0_device configuration	option.

       network0_device	  Normally  vm-bhyve  will  create  a tap(4) device at
			  run-time for each virtual network  interface.	  This
			  may  be  an  issue  in  more advanced	configurations
			  where	you want to pre-configure the networking manu-
			  ally in a way	unsupported by vm-bhyve.  This	option
			  allows  you  to instruct vm-bhyve to use an existing
			  network device for this  virtual  interface,	rather
			  than creating	one dynamically.

       network0_mac	  This	option	allows you to specify a	mac address to
			  use for this interface.  If not  provided,  bhyve(8)
			  will generate	a mac address.

       network0_span	  Set  this  option to yes to instruct vm-bhyve	to add
			  the virtual network interface	to  the	 switch	 as  a
			  span	port on	the bridge.  The default is to add the
			  port to the switch as	an ordinary bridge member.

       disk0_type	  The emulation	type for the first virtual  disk.   At
			  least	 one  virtual disk is required.	 Valid options
			  for this are currently virtio-blk, ahci-hd, ahci-cd,
			  and nvme.  Additional	disks can be added  by	adding
			  additional diskX_type	and diskX_name values, replac-
			  ing X	with the next available	integer.

       disk0_name	  The  filename	for the	first virtual disk.  The first
			  disk is created automatically	 when  provisioning  a
			  new  virtual machine.	 If additional disks are added
			  manually, the	image will need	to be created, usually
			  done using the truncate(1) or	zfs(8) commands.   Al-
			  ternatively,	you  can use the vm add	command, which
			  will create the disk image for you.

			  Normally disk	images or zvols	 are  stored  directly
			  inside  the  guest.	To  use	 a  disk image that is
			  stored anywhere else,	you can	specify	the full  path
			  in this option, and configure	the device as custom.

			  To use an established	iscsi device, specify a	target
			  'session[/lun]'  (default /0)	which matches a	unique
			  session from the 'iscsictl(8)	 -L'  command  output,
			  and configure	the device as iscsi.

       disk0_dev	  The  type  of	 device	 to  use for the disk.	If not
			  specified, this will default to file,	and  a	sparse
			  file,	 located  in the guest directory, will be used
			  as the disk image.  Other options include:  zvol  or
			  sparse-zvol  (which  will use	a ZVOL as the disk im-
			  age, created	directly  under	 the  guest  dataset),
			  custom, and iscsi.

			  When	using custom, the diskX_name parameter must be
			  set to the full path to the image file or device.

			  Already attached iscsi devices can have their	device
			  nodes	dynamically detected and used by setting  this
			  option to iscsi and diskX_name as described above.

       disk0_opts	  Any  additional options to use for this disk device.
			  Multiple options can be specified,  separated	 by  a
			  comma.   Please  see	the bhyve(8) man page for more
			  details on supported options.

       disk0_size	  This setting can be specified	in  templates  to  set
			  the  size  of	 this disk.  When creating a guest, vm
			  will default to creating a 20G image for each	 disk,
			  unless  an  alternative size is specified using this
			  option.  The size of the first disk can be  overrid-
			  den using the	-s option.

			  NOTE:	 This  setting is only supported in templates.
			  It has no function in	real guest configuration,  and
			  is  not  copied  over	 when  a new machine is	provi-
			  sioned.

       ahci_device_limit  By default, all AHCI devices are added on their  own
			  controller in	a unique slot/function.	 In FreeBSD 12
			  it  is  possible to put up to	32 devices on one con-
			  troller.  This setting allows	 you  to  control  the
			  number  of  devices  (ahci-hd/ahci-cd) that vm-bhyve
			  will put on a	single controller.  The	default	 is  1
			  and allowed values are 2-32.

       uuid		  This	option	allows you to specify a	fixed UUID for
			  the guests SMBIOS.  Normally,	the UUID is  generated
			  by  bhyve(8)	based  on the hostname and guest name.
			  Because this may change if guests are	moved  between
			  systems, the vm create command automatically assigns
			  a UUID to all	newly created guests.

       ignore_bad_msr	  Set to true|on|yes|1 to configure bhyve(8) to	ignore
			  accesses  to unimplemented model specific registers.
			  This is commonly required  on	 AMD  processors,  al-
			  though is enabled by default for UEFI	guests.

       bhyve_options	  Specify  any	additional  command  line arguments to
			  pass to the bhyve command.  This allows the  use  of
			  options  such	 as  cpu pinning or debug that are not
			  exposed by vm-bhyve.

       grub_installX	  This option allows  you  to  specify	grub  commands
			  needed  to boot the install media for	this guest.  X
			  should be an integer starting	at 0, with  additional
			  grub commands	using the next numbers in sequence.

			  If  no  install  commands  are specified, grub-bhyve
			  will be run on the guests console, so	 you  can  use
			  the  standard	 vm  console  subcommand to access the
			  bootloader if	needed.

       grub_run_partition
			  Specify the partition	that grub should look  in  for
			  the  grub configuration files.  By default, vm-bhyve
			  will specify partition 1, which is correct  in  most
			  standard cases.

       grub_runX	  The  option  allows you to specify the grub commands
			  needed to boot the guest from	disk.  X should	be  an
			  integer starting at 0, with additional grub commands
			  using	the next numbers in sequence.

			  If  no  boot commands	are specified, grub-bhyve will
			  be run on the	guests console,	so  you	 can  use  the
			  standard  vm	console	subcommand to access the boot-
			  loader if needed.

			  The sample templates contain	examples  of  how  the
			  grub configuration variables can be used.

       grub_run_dir	  By  default  grub-bhyve  will	 look in the directory
			  /boot/grub for the grub  configuration  file.	  This
			  option  allows  you  to specify an alternate path to
			  use when starting a guest.

       grub_run_file	  Allows you to	specify	the  grub  configuration  file
			  that	grub-bhyve  will  look	for  inside the	guest,
			  rather than the default of grub.cfg.

       passthruX	  Specify a device to pass through to the guest.   You
			  will	need to	reserve	the device first so that is it
			  claimed by the ppt driver on boot.

			  Once the device is successfully  reserved,  you  can
			  add  it  to the guest	by adding passthruX="1/2/3" to
			  the guest configuration file,	where X	is an  integer
			  starting  at	0, and 1/2/3 is	the Base/Slot/Function
			  of the device.  If you are passing through  multiple
			  functions  on	 the  same  device, make sure they are
			  specified together in	the configuration file in  the
			  same sequence	as the original	device.

			  Please					   see
			  https://wiki.freebsd.org/bhyve/pci_passthru for more
			  details on how this works.

       virt_random	  Set this option to yes  if  you  want	 to  create  a
			  virtio-rnd device for	this guest.

       graphics		  If set to yes, a frame buffer	is added to the	guest.
			  This provides	a graphical console that is accessible
			  using	 VNC.	By default the console is 800x600, and
			  will listen on 0.0.0.0:5900.	If port	 5900  is  not
			  available,  the  next	 available  port will be used.
			  The active address and port can be viewed in vm list
			  and vm info output.

       graphics_port	  This option allows you to specific a fixed port that
			  the VNC service should listen	on.   Please  remember
			  that	all guests should ideally use a	unique port to
			  avoid	any problems.

       graphics_listen	  By default the graphical VNC console will listen  on
			  0.0.0.0,  so	is  accessible by connecting to	any IP
			  address assigned to the bhyve	host.  Use this	option
			  to specify a specific	IP address that	the  VNC  ser-
			  vice should bind to.

       graphics_res	  Specify  the	resolution of the graphical console in
			  WxH format.  Please note that	only a	certain	 range
			  of  resolutions are currently	supported.  Please see
			  config.sample	for a full up-to-date list.

       graphics_wait	  Set this to yes in order to make guest boot wait for
			  the VNC console to be	opened.	 This  can  help  when
			  installing  operating	systems	that require immediate
			  keyboard  input  (such  as  a	 timed	'enter	setup'
			  screen).   Set  to no	in order to completely disable
			  this function.

			  The default is auto, in which	case the console  will
			  wait	if the guest is	started	in install mode.  Note
			  that after the first boot, the system	will boot  im-
			  mediately  as	 normal.  To force the console to wait
			  on each boot,	the yes	setting	should be used.

       graphics_vga	  This configures how the graphics card	is exposed  to
			  the  guest.	Valid  options are io (default), on or
			  off.	Please see the bhyve(8)	man page for more  de-
			  tails	on this	option.

       xhci_mouse	  Set  this  option to yes in order to provide an XHCI
			  mouse	device to the guest.  This tracks much	better
			  than the default PS2 mouse in	VNC settings, although
			  this mouse may not supported by older	guests.

       sound		  Set  this option to yes in order to provide HD Audio
			  Emulation to the guest.  Please see bhyve(8) for de-
			  tails.

       sound_play	  Set this to the desired audio	output device  of  the
			  host to the guest.  Defaults to '/dev/dsp0'

       sound_rec	  Set  this  to	 the desired audio input device	of the
			  host to the guest.  If empty no audio	 input	device
			  is configured.  Defaults to '' (empty)

       virt_consoleX	  Allows  the  creation	of up to 16 virtio-console de-
			  vices	in the guest.  The value to this option	can be
			  yes|on|1 to create a numbered	 port.	 This  is  the
			  only method supported	by some	guests.

			  If any other value is	provided, this will be used as
			  the	  name	   of	  the	 port.	   The	  name
			  org.freenas.bhyve-agent can be useful, as it ties in
			  with utilities written for the  FreeNAS  bhyve-agent
			  interface.

       zfs_dataset_opts	  This	allows	you to specify one or more ZFS proper-
			  ties to set on the dataset when a guest is  created.
			  Because  properties  are  assigned as	the dataset is
			  created, this	option is most useful  when  specified
			  inside a template.  As a guest is created, all prop-
			  erties  listed in this option	will be	applied	to the
			  guest	dataset.

			  Multiple properties can be specified,	separated by a
			  space.  Please note that spaces  are	not  currently
			  supported in the property values.

       zfs_zvol_opts	  Allows  you to specify ZFS properties	that should be
			  assigned to any ZVOLs	that are created for a	guest.
			  As with zfs_dataset_opts, this makes most sense when
			  entered  into	 a  template, as the properties	can be
			  assigned while a guest is being created.  Some  ZVOL
			  options,  such  as  volblocksize  can	only be	set at
			  creation time.

			  Multiple properties can be specified,	separated by a
			  space.  For example, the  following  will  configure
			  the  ZVOL  block  size to 128k, and turn compression
			  off.

			  zfs_zvol_opts="volblocksize=128k compress=off"

       prestart		  Allows you to	specify	a script  or  executable  that
			  will	run  before the	guest starts, including	on re-
			  boot.	 This is provided  the	guest  name,  and  ZFS
			  dataset  (if	applicable)  as	 arguments.   We  also
			  change directory to the guest	 path  before  running
			  the script.

			  This	can  be	 specified  as	a full path, or	just a
			  script filename.  In the latter case we look in  the
			  guest	directory for the script.

			  Note	that although the guest	is technically stopped
			  when this process runs, calls	to vm will still  con-
			  sider	the guest locked.

       priority		  Allows a priority to be set for a guest by using the
			  nice(1) facility.  The default value is 0, and has a
			  range	 from  -20,  which is the highest priority, to
			  20.  A priority of 20	will cause the guest  to  only
			  run when the host system is idle.

       limit_pcpu	  Limit	 the  bhyve  process to	the specified cpu per-
			  centage.

			  Please note this, as with all	 limit	settings,  re-
			  quires rctl(8) to be enabled in your kernel.

       limit_rbps	  Limit	 guest	disk  read throughput to the specified
			  bits per second.

       limit_wbps	  Limit	guest disk write throughput to	the  specified
			  bits per second.

       limit_riops	  Limit	 guest	disk read iops to the specified	number
			  of operations	per second.

       limit_wiops	  Limit	guest disk write iops to the specified	number
			  of operations	per second.

SEE ALSO
       cu(1),  fetch(1),  tmux(1),  truncate(1),  bridge(4),  nmdm(4), tap(4),
       vlan(4),	bhyve(8), bhyveload(8),	rctl(8), zfs(8)

KNOWN BUGS
       If a guest is renamed, and then cloned using a  snapshot	 taken	before
       the  rename,  vm-bhyve  is unable to find the guest configuration file.
       This is because the configuration file in the snapshot still refers  to
       the  old	guest name.  In	this circumstance, vm-bhyve will output	an er-
       ror during cloning detailing that the configuration  file  in  the  new
       guest will need to be renamed and updated manually.

       On some systems it has been observed that bridging can cause interfaces
       to go down for up to 10 seconds,	which is enough	to stall ssh sessions.
       This  is	 noticable  when  the  first guest is started or when the last
       guest is	stopped.  Once there are at least 2  interfaces	 bridged  (one
       real   interface	  and	a   tap	 interface),  further  guests  can  be
       started/stopped without issue.

       Please report all bugs/issues/feature requests to the GitHub project at
       https://github.com/freebsd/vm-bhyve

AUTHORS
       Matt Churchyard <churchers@gmail.com>
       Koichiro	Iwao <meta@FreeBSD.org>

FreeBSD	15.0		       September 1, 2025		   VM-BHYVE(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=vm&manpath=FreeBSD+15.0-RELEASE+and+Ports.quarterly>

home | help