Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
lspci(8)			The PCI Utilities			lspci(8)

NAME
     lspci - list all PCI devices

SYNOPSIS
     lspci [options]

DESCRIPTION
     lspci is a utility for displaying information about PCI buses in the system
     and devices connected to them.

     By default, it shows a brief list of devices. Use the options described be-
     low  to request either a more verbose output or output intended for parsing
     by other programs.

     If you are going to report bugs in PCI device drivers or in  lspci  itself,
     please  include  output of "lspci -vvx" or even better "lspci -vvxxx" (how-
     ever, see below for possible caveats).

     Some parts of the output, especially in the highly verbose modes, are prob-
     ably intelligible only to experienced PCI hackers. For exact definitions of
     the fields, please consult either the PCI specifications  or  the	header.h
     and /usr/include/linux/pci.h include files.

     Access  to  some parts of the PCI configuration space is restricted to root
     on many operating systems, so the features of  lspci  available  to  normal
     users  are  limited.  However,  lspci  tries its best to display as much as
     available and mark all other information with <access denied> text.

OPTIONS
   Basic display modes
     -m     Dump PCI device data in a backward-compatible machine readable form.
	    See below for details.

     -mm    Dump PCI device data in a machine readable form for easy parsing  by
	    scripts.  See below for details.

     -t     Show  a tree-like diagram containing all buses, bridges, devices and
	    connections between them.

   Display options
     -v     Be verbose and display detailed information about all devices.

     -vv    Be very verbose and display more details. This level includes every-
	    thing deemed useful.

     -vvv   Be even more verbose and display everything we are	able  to  parse,
	    even  if  it doesn't look interesting at all (e.g., undefined memory
	    regions).

     -k     Show kernel drivers handling each device and also kernel modules ca-
	    pable of handling it.  Turned on by default when -v is given in  the
	    normal  mode  of output.  (Currently works only on Linux with kernel
	    2.6 or newer.)

     -x     Show hexadecimal dump of the  standard  part  of  the  configuration
	    space (the first 64 bytes or 128 bytes for CardBus bridges).

     -xxx   Show  hexadecimal  dump  of the whole PCI configuration space. It is
	    available only to root as several PCI devices crash when you try  to
	    read  some parts of the config space (this behavior probably doesn't
	    violate the PCI standard, but it's at least very  stupid).	However,
	    such devices are rare, so you needn't worry much.

     -xxxx  Show  hexadecimal dump of the extended (4096-byte) PCI configuration
	    space available on PCI-X 2.0 and PCI Express buses.

     -b     Bus-centric view. Show all IRQ numbers and addresses as seen by  the
	    cards on the PCI bus instead of as seen by the kernel.

     -D     Always show PCI domain numbers. By default, lspci suppresses them on
	    machines which have only domain 0.

     -P     Identify  PCI devices by path through each bridge, instead of by bus
	    number.

     -PP    Identify PCI devices by path through each bridge,  showing	the  bus
	    number as well as the device number.

   Options to control resolving ID's to names
     -n     Show  PCI vendor and device codes as numbers instead of looking them
	    up in the PCI ID list.

     -nn    Show PCI vendor and device codes as both numbers and names.

     -q     Use DNS to query the central PCI ID database  if  a  device  is  not
	    found  in the local pci.ids file. If the DNS query succeeds, the re-
	    sult is cached in $XDG_CACHE_HOME/pci-ids and it  is  recognized  in
	    subsequent	runs  even  if -q is not given any more. Please use this
	    switch inside automated scripts only with caution to avoid overload-
	    ing the database servers.

     -qq    Same as -q, but the local cache is reset.

     -Q     Query the central database even for entries which are recognized lo-
	    cally.  Use this if you suspect that the displayed entry is wrong.

   Options for selection of devices
     -s [[[[<domain>]:]<bus>]:][<device>][.[<func>]]
	    Show only devices in the specified domain (in case your machine  has
	    several  host  bridges,  they  can	either share a common bus number
	    space or each of them can address a PCI domain of its  own;  domains
	    are  numbered  from  0 to ffff), bus (0 to ff), device (0 to 1f) and
	    function (0 to 7).	Each component of  the	device	address  can  be
	    omitted  or  set  to  "*", both meaning "any value". All numbers are
	    hexadecimal.  E.g., "0:" means all devices on bus 0, "0"  means  all
	    functions  of  device  0 on any bus, "0.3" selects third function of
	    device 0 on all buses and ".4" shows only  the  fourth  function  of
	    each device.

     -d [<vendor>]:[<device>][:<class>[:<prog-if>]]
	    Show  only devices with specified vendor, device, class ID, and pro-
	    gramming interface.  The ID's are given in hexadecimal  and  may  be
	    omitted  or given as "*", both meaning "any value". The class ID can
	    contain "x" characters which stand for "any digit".

   Other options
     -i <file>
	    Use <file> as the  PCI  ID	list  instead  of  /usr/local/share/pci-
	    ids/pci.ids.

     -p <file>
	    Use  <file> as the map of PCI ID's handled by kernel modules. By de-
	    fault, lspci uses  /lib/modules/kernel_version/modules.pcimap.   Ap-
	    plies only to Linux systems with recent enough module tools.

     -M     Invoke  bus  mapping  mode which performs a thorough scan of all PCI
	    devices, including those behind misconfigured bridges, etc. This op-
	    tion gives meaningful results only with  a	direct	hardware  access
	    mode,  which  usually requires root privileges.  By default, the bus
	    mapper scans domain. You can use the -s option to select a different
	    domain.

     --version
	    Shows lspci version. This option should be used stand-alone.

   PCI access options
     The PCI utilities use the PCI library to talk to PCI devices (see pcilib(7)
     for details). You can use the following options to influence its behavior:

     -A <method>
	    The library supports a variety of methods to access  the  PCI  hard-
	    ware.   By	default,  it uses the first access method available, but
	    you can use this option to override this decision. See -A help for a
	    list of available methods and their descriptions.

     -O <param>=<value>
	    The behavior of the library is controlled by several  named  parame-
	    ters.  This option allows one to set the value of any of the parame-
	    ters.  Use	-O help for a list of known parameters and their default
	    values.

     -H1    Use direct hardware access	via  Intel  configuration  mechanism  1.
	    (This is a shorthand for -A intel-conf1.)

     -H2    Use  direct  hardware  access  via	Intel configuration mechanism 2.
	    (This is a shorthand for -A intel-conf2.)

     -F <file>
	    Instead of accessing real hardware, read the  list	of  devices  and
	    values of their configuration registers from the given file produced
	    by	an earlier run of lspci -x.  This is very useful for analysis of
	    user-supplied bug reports, because you can display the hardware con-
	    figuration in any way you want without disturbing the user with  re-
	    quests for more dumps.

     -G     Increase debug level of the library.

MACHINE READABLE OUTPUT
     If  you intend to process the output of lspci automatically, please use one
     of the machine-readable output formats (-m, -vm, -vmm)  described	in  this
     section. All other formats are likely to change between versions of lspci.

     All  numbers  are always printed in hexadecimal. If you want to process nu-
     meric ID's instead of names, please add the -n switch.

   Simple format (-m)
     In the simple format, each device is described on a single line,  which  is
     formatted	as parameters suitable for passing to a shell script, i.e., val-
     ues separated by whitespaces, quoted and escaped if necessary.  Some of the
     arguments are positional: slot, class, vendor name, device name,  subsystem
     vendor name and subsystem name (the last two are empty if the device has no
     subsystem); the remaining arguments are option-like:

     -rrev  Revision number.

     -pprogif
	    Programming interface.

     The  relative  order of positional arguments and options is undefined.  New
     options can be added in future versions, but they will always have a single
     argument not separated from the option by any spaces, so they can be easily
     ignored if not recognized.

   Verbose format (-vmm)
     The verbose output is a sequence of records separated by blank lines.  Each
     record describes a single device by a sequence of lines, each line contain-
     ing a single `tag: value' pair. The tag and the value are	separated  by  a
     single  tab  character.   Neither the records nor the lines within a record
     are in any particular order.  Tags are case-sensitive.

     The following tags are defined:

     Slot   The name of the slot  where  the  device  resides  ([domain:]bus:de-
	    vice.function).  This tag is always the first in a record.

     Class  Name of the class.

     Vendor
	    Name of the vendor.

     Device
	    Name of the device.

     SVendor
	    Name of the subsystem vendor (optional).

     SDevice
	    Name of the subsystem (optional).

     PhySlot
	    The physical slot where the device resides (optional, Linux only).

     Rev    Revision number (optional).

     ProgIf
	    Programming interface (optional).

     Driver
	    Kernel driver currently handling the device (optional, Linux only).

     Module
	    Kernel  module  reporting  that it is capable of handling the device
	    (optional, Linux only). Multiple lines with this tag can occur.

     NUMANode
	    NUMA node this device is connected to (optional, Linux only).

     IOMMUGroup
	    IOMMU group that this device is part of (optional, Linux only).

     New tags can be added in future versions, so you should silently ignore any
     tags you don't recognize.

   Backward-compatible verbose format (-vm)
     In this mode, lspci tries to be perfectly compatible with its old versions.
     It's almost the same as the regular verbose format, but the Device  tag  is
     used  for both the slot and the device name, so it occurs twice in a single
     record. Please avoid using this format in any new code.

FILES
     /usr/local/share/pciids/pci.ids
	    A list of all known PCI ID's (vendors,  devices,  classes  and  sub-
	    classes). Maintained at https://pci-ids.ucw.cz/, use the update-pci-
	    ids utility to download the most recent version.

     /usr/local/share/pciids/pci.ids.gz
	    If	lspci  is  compiled  with  support for compression, this file is
	    tried before pci.ids.

     $XDG_CACHE_HOME/pci-ids
	    All ID's found in the DNS query mode are cached in this file.

BUGS
     Sometimes, lspci is not able to decode  the  configuration  registers  com-
     pletely.	This usually happens when not enough documentation was available
     to the authors.  In such cases, it at least prints the <?> mark  to  signal
     that  there  is potentially something more to say. If you know the details,
     patches will be of course welcome.

     Access to the extended configuration space is currently supported	only  by
     the linux_sysfs back-end.

SEE ALSO
     setpci(8), pci.ids(5), update-pciids(8), pcilib(7)

AUTHOR
     The PCI Utilities are maintained by Martin Mares <mj@ucw.cz>.

pciutils-3.14.0 		  21 June 2025				lspci(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=lspci&sektion=8&manpath=FreeBSD+15.1-RELEASE+and+Ports>

home | help