NAME
     mptutil -- Utility for managing LSI Fusion-MPT controllers

SYNOPSIS
     mptutil version
     mptutil [-u unit] show adapter
     mptutil [-u unit] show config
     mptutil [-u unit] show drives
     mptutil [-u unit] show events
     mptutil [-u unit] show volumes
     mptutil [-u unit] fail drive
     mptutil [-u unit] online drive
     mptutil [-u unit] offline drive
     mptutil [-u unit] name volume name
     mptutil [-u unit] volume status volume
     mptutil [-u unit] volume cache volume enable|enabled|disable|disabled
     mptutil [-u unit] clear
     mptutil [-u unit] create type [-q] [-v] [-s stripe_size]
	     drive[,drive[,...]]
     mptutil [-u unit] delete volume
     mptutil [-u unit] add drive [volume]
     mptutil [-u unit] remove drive

DESCRIPTION
     The  mptutil utility can be used to display or modify various parameters on
     LSI Fusion-MPT controllers.  Each invocation of mptutil consists of zero or
     more global options followed by a command.  Commands may support additional
     optional or required arguments after the command.

     Currently one global option is supported:

     -u unit
	     unit specifies the unit of the controller to work with.  If no unit
	     is specified, then unit 0 is used.

     Volumes may be specified in two forms.  First, a volume may  be  identified
     by  its location as [xx:]yy where xx is the bus ID and yy is the target ID.
     If the bus ID is omitted, the volume is assumed to be on bus 0.  Second, on
     the volume may be specified by the corresponding daX device, such as da0.

     The mpt(4) controller divides drives up into  two	categories.   Configured
     drives  belong to a RAID volume either as a member drive or as a hot spare.
     Each configured drive is assigned a unique device ID such as 0 or 1 that is
     show in show config, and in the first column of show drives.  Any drive not
     associated with a RAID volume as either a member or a hot spare is a stand-
     alone drive.  Standalone drives are visible to the operating system as SCSI
     disk devices.  As a result, drives may be specified in three forms.  First,
     a configured drive may be identified by its device ID.  Second,  any  drive
     may be identified by its location as xx:yy where xx is the bus ID and yy is
     the target ID for each drive as displayed in show drives.	Note that unlike
     volumes,  a  drive  location  always requires the bus ID to avoid confusion
     with device IDs.  Third, a standalone drive that is not part  of  a  volume
     may  be  identified  by  its  corresponding daX device as displayed in show
     drives.

     The mptutil utility supports several different  groups  of  commands.   The
     first  group of commands provide information about the controller, the vol-
     umes it manages, and the drives it controls.  The second group of	commands
     are  used	to  manage  the physical drives attached to the controller.  The
     third group of commands are used to manage the logical volumes  managed  by
     the  controller.  The fourth group of commands are used to manage the drive
     configuration for the controller.

     The informational commands include:

     version
	     Displays the version of mptutil.

     show adapter
	     Displays information about the RAID controller such  as  the  model
	     number.

     show config
	     Displays  the  volume  and  drive configuration for the controller.
	     Each volume is listed along with the physical drives that the  vol-
	     ume  spans.   If any hot spare drives are configured, then they are
	     listed as well.

     show drives
	     Lists all of the physical drives attached to the controller.

     show events
	     Display all the entries from the controller's event  log.	 Due  to
	     lack of documentation this command is not very useful currently and
	     just dumps each log entry in hex.

     show volumes
	     Lists all of the logical volumes managed by the controller.

     The physical drive management commands include:

     fail drive
	     Mark  drive as "failed requested".  Note that this state is differ-
	     ent from the "failed" state that is used when the firmware fails  a
	     drive.  Drive must be a configured drive.

     online drive
	     Mark  drive  as  an  online drive.  Drive must be part a configured
	     drive in either the "offline" or "failed requested" states.

     offline drive
	     Mark drive as offline.  Drive must be a configured, online drive.

     The logical volume management commands include:

     name volume name
	     Sets the name of volume to name.

     volume cache volume enable|enabled|disable|disabled
	     Enables or disables the drive write cache for the member drives  of
	     volume.

     volume status volume
	     Display  more  detailed  status about a single volume including the
	     current progress of a rebuild operation if one is being performed.

     The configuration commands include:

     clear   Delete the entire configuration including all volumes  and  spares.
	     All drives will become standalone drives.

     create type [-q] [-v] [-s stripe_size] drive[,drive[,...]]
	     Create a new volume.  The type specifies the type of volume to cre-
	     ate.  Currently supported types include:

	     raid0   Creates  one RAID0 volume spanning the drives listed in the
		     single drive list.

	     raid1   Creates one RAID1 volume spanning the drives listed in  the
		     single drive list.

	     raid1e  Creates one RAID1E volume spanning the drives listed in the
		     single drive list.

	     Note: Not all volume types are supported by all controllers.

	     If  the -q flag is specified after type, then a "quick" initializa-
	     tion of the volume will be done.  This is useful when the drives do
	     not contain any existing data that need to be preserved.

	     If the -v flag is specified after type, then  more  verbose  output
	     will be enabled.  Currently this just provides notification as dri-
	     ves are added to volumes when building the configuration.

	     The -s stripe_size parameter allows the stripe size of the array to
	     be  set.	By  default  a	stripe size of 64K is used.  The list of
	     valid values for a given type are listed  in  the	output	of  show
	     adapter.

     delete volume
	     Delete  the  volume  volume.   Member drives will become standalone
	     drives.

     add drive [volume]
	     Mark drive as a hot spare.  Drive must not be a member of a volume.
	     If volume is specified, then the hot spare  will  be  dedicated  to
	     that  volume.   Otherwise, drive will be used as a global hot spare
	     backing all volumes for this controller.  Note that drive	must  be
	     as large as the smallest drive in all of the volumes it is going to
	     back.

     remove drive
	     Remove  the  hot spare drive from service.  It will become a stand-
	     alone drive.

EXAMPLES
     Mark the drive at bus 0 target 4 as offline:

	   mptutil offline 0:4

     Create a RAID1 array from the two standalone drives da1 and da2:

	   mptutil create raid1 da1,da2

     Mark standalone drive da3 as a global hot spare:

	   mptutil add da3

SEE ALSO
     mpt(4)

HISTORY
     The mptutil utility first appeared in FreeBSD 8.0.

BUGS
     The handling of spare drives appears to be unreliable.  The mpt(4) firmware
     manages spares via spare drive "pools".  There are eight pools  numbered  0
     through  7.   Each spare drive can only be assigned to a single pool.  Each
     volume can be backed by any combination of zero or more spare  pools.   The
     mptutil  utility  attempts  to  use  the  following  algorithm for managing
     spares.  Global spares are always assigned to pool 0, and all  volumes  are
     always  backed by pool 0.	For dedicated spares, mptutil assigns one of the
     remaining 7 pools to each volume and assigns dedicated drives to that pool.
     In practice however, it seems that assigning a drive as a	spare  does  not
     take  effect until the box has been rebooted.  Also, the firmware renumbers
     the spare pool assignments after a reboot which undoes the effects  of  the
     algorithm above.  Simple cases such as assigning global spares seem to work
     ok  (albeit requiring a reboot to take effect) but more "exotic" configura-
     tions may not work reliably.

     Drive configuration commands result in an excessive flood	of  messages  on
     the console.

     The  mpt  version 1 API that is used by mptutil and mpt(4) does not support
     volumes above two terabytes.  This is a limitation of the API.  If you  are
     using  this adapter with volumes larger than two terabytes, use the adapter
     in JBOD mode.  Utilize geom(8), zfs(8), or another software volume  manager
     to work around this limitation.