Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
SA(4)			     Kernel Interfaces Manual			   SA(4)

NAME
     sa -- SCSI Sequential Access device driver

SYNOPSIS
     device sa

DESCRIPTION
     The  sa  driver provides support for all SCSI devices of the sequential ac-
     cess class that are attached to the system through a  supported  SCSI  Host
     Adapter.  The sequential access class includes tape and other linear access
     devices.

     A	SCSI Host adapter must also be separately configured into the system be-
     fore a SCSI sequential access device can be configured.

MOUNT SESSIONS
     The sa driver is based around the concept of a "mount  session",  which  is
     defined as the period between the time that a tape is mounted, and the time
     when  it is unmounted.  Any parameters set during a mount session remain in
     effect for the remainder of the session or until replaced.  The tape can be
     unmounted, bringing the session to a close in several ways.  These include:

     1.   Closing a `rewind device', referred to as sub-mode 00 below.	An exam-
	  ple is /dev/sa0.

     2.   Using the MTOFFL ioctl(2) command,  reachable  through  the  `offline'
	  command of mt(1).

     It  should be noted that tape devices are exclusive open devices, except in
     the case where a control mode device is opened.  In the latter case, exclu-
     sive access is only sought when needed (e.g., to set parameters).

SUB-MODES
     The sub-modes differ in the action taken when the device is closed:

     /dev/sa*
	   A close will rewind the device; if the tape has been written, then  a
	   file mark will be written before the rewind is requested.  The device
	   is unmounted.

     /dev/nsa*
	   A  close  will leave the tape mounted.  If the tape was written to, a
	   file mark will be written.  No other head  positioning  takes  place.
	   Any	further reads or writes will occur directly after the last read,
	   or the written file mark.

     /dev/esa*
	   A close will rewind the device.  If the tape has been written, then a
	   file mark will be written before the rewind is requested.  On comple-
	   tion of the rewind an unload command will be issued.  The  device  is
	   unmounted.

BLOCKING MODES
     SCSI  tapes may run in either `variable' or `fixed' block-size modes.  Most
     QIC-type devices run in fixed block-size mode, where most nine-track  tapes
     and  many	new cartridge formats allow variable block-size.  The difference
     between the two is as follows:

     Variable block-size: Each write made to the device results in a single log-
     ical record written to the tape.  One can never read or  write  part  of  a
     record  from tape (though you may request a larger block and read a smaller
     record); nor can one read multiple blocks.  Data from  a  single  write  is
     therefore read by a single read.  The block size used may be any value sup-
     ported  by  the  device, the SCSI adapter and the system (usually between 1
     byte and 64 Kbytes, sometimes more).

     When reading a variable record/block from the tape, the head  is  logically
     considered  to be immediately after the last item read, and before the next
     item after that.  If the next item is a file mark, but it was  never  read,
     then  the	next  process to read will immediately hit the file mark and re-
     ceive an end-of-file notification.

     Fixed block-size: Data written by the user is passed to the tape as a  suc-
     cession  of  fixed  size blocks.  It may be contiguous in memory, but it is
     considered to be a series of independent blocks.  One may	never  write  an
     amount  of  data  that  is not an exact multiple of the blocksize.  One may
     read and write the same data as a	different  set	of  records.   In  other
     words,  blocks that were written together may be read separately, and vice-
     versa.

     If one requests more blocks than remain in the file,  the	drive  will  en-
     counter  the file mark.  As there is some data to return (unless there were
     no records before the file mark), the read  will  succeed,  returning  that
     data.  The next read will return immediately with a value of 0.  (As above,
     if  the file mark is never read, it remains for the next process to read if
     in no-rewind mode.)

BLOCK SIZES
     By default, the driver will NOT accept reads or writes  to  a  tape  device
     that  are larger than may be written to or read from the mounted tape using
     a single write or read request.  Because of this,	the  application  author
     may  have	confidence  that  his wishes are respected in terms of the block
     size written to tape.  For example, if the user  tries  to  write	a  256KB
     block  to	the  tape, but the controller can handle no more than 128KB, the
     write will fail.  The previous FreeBSD behavior, prior to FreeBSD 10.0, was
     to break up large reads or writes into smaller blocks  when  going  to  the
     tape.   The problem with that behavior, though, is that it hides the actual
     on-tape block size from the application writer, at least in variable  block
     mode.

     If  the  user would like his large reads and writes broken up into separate
     pieces, he may set the following loader tunables.	Note that these tunables
     WILL GO AWAY in FreeBSD 11.0.  They are provided  for  transition	purposes
     only.

     kern.cam.sa.allow_io_split

	 This  variable,  when	set to 1, will configure all sa devices to split
	 large buffers into smaller pieces when needed.

     kern.cam.sa.%d.allow_io_split

	 This variable, when set to 1, will configure the given sa unit to split
	 large buffers into multiple pieces.  This will override the global set-
	 ting, if it exists.

     There are several sysctl(8) variables available to view block handling  pa-
     rameters:

     kern.cam.sa.%d.allow_io_split

	 This  variable  allows the user to see, but not modify, the current I/O
	 split setting.  The user is not permitted to  modify  this  setting  so
	 that  there is no chance of behavior changing for the application while
	 a tape is mounted.

     kern.cam.sa.%d.maxio

	 This variable shows the maximum I/O size in bytes that  is  allowed  by
	 the combination of kernel tuning parameters (MAXPHYS, DFLTPHYS) and the
	 capabilities of the controller that is attached to the tape drive.  Ap-
	 plications  may  look at this value for a guide on how large an I/O may
	 be permitted, but should keep in mind that the actual	maximum  may  be
	 restricted  further  by  the  tape drive via the SCSI READ BLOCK LIMITS
	 command.

     kern.cam.sa.%d.cpi_maxio

	 This variable shows the maximum I/O size supported by	the  controller,
	 in bytes, that is reported via the CAM Path Inquiry CCB (XPT_PATH_INQ).
	 If this is 0, that means that the controller has not reported a maximum
	 I/O size.

FILE MARK HANDLING
     The  handling of file marks on write is automatic.  If the user has written
     to the tape, and has not done a read since the last write, then a file mark
     will be written to the tape when the device is closed.  If a rewind is  re-
     quested  after  a	write, then the driver assumes that the last file on the
     tape has been written, and ensures that there are two file marks written to
     the tape.	The exception to this is that  there  seems  to  be  a	standard
     (which  we follow, but do not understand why) that certain types of tape do
     not actually write two file marks to tape, but when read, report  a  `phan-
     tom'  file  mark when the last file is read.  These devices include the QIC
     family of devices.  (It might be that this set of devices is the  same  set
     as that of fixed block devices.  This has not been determined yet, and they
     are treated as separate behaviors by the driver at this time.)

PARAMETERS
     The  sa driver supports a number of parameters.  The user can query parame-
     ters using "mt param -l" (which uses the MTIOCPARAMGET ioctl) and the  user
     can  set  parameters  using  "mt  param  -s"  (which uses the MTIOCPARAMSET
     ioctl).  See mt(1) and mtio(4) for more details on the interface.

     Supported parameters:

     sili   The default is 0.  When set to 1, it  sets	the  Suppress  Incorrect
	    Length Indicator (SILI) bit on tape reads.	Tape drives normally re-
	    turn  sense  data (which contains the residual) when the application
	    reads a block that is not the same length as the amount of data  re-
	    quested.   The  SILI bit suppresses that notification in most cases.
	    See the SSC-5 spec (available at t10.org), specifically the  section
	    on the READ(6) command, for more information.

     eot_warn
	    The  default  is 0.  By default, the sa driver reports entering Pro-
	    grammable Early Warning, Early Warning and End of  Media  conditions
	    by	returning  a write with 0 bytes written, and errno set to 0.  If
	    eot_warn is set to 1, the sa driver will set errno to ENOSPC when it
	    enters any of the out of space conditions.

     protection.protection_supported
	    This is a read-only parameter, and is set to 1  if	the  tape  drive
	    supports protection information.

     protection.prot_method
	    If	protection  is	supported,  set  this  to the desired protection
	    method supported by the tape drive.  As of	SSC-5r03  (available  at
	    t10.org), the protection method values are:

	    0	 No protection.

	    1	 Reed-Solomon CRC, 4 bytes in length.

	    2	 CRC32C, 4 bytes in length.

     protection.pi_length
	    Length of the protection information, see above for lengths.

     protection.lbp_w
	    If	set  to  1,  enable logical block protection on writes.  The CRC
	    must be appended to the end of the block written to the tape driver.
	    The tape drive will verify the CRC when it receives the block.

     protection.lbp_r
	    If set to 1, enable logical block protection on reads.  The CRC will
	    be appended to the end of the block read from the tape driver.   The
	    application should verify the CRC when it receives the block.

     protection.rdbp
	    If set to 1, enable logical block protection on the RECOVER BUFFERED
	    DATA  command.   The  sa  driver  does not currently use the RECOVER
	    BUFFERED DATA command.

TIMEOUTS
     The sa driver has a set of default timeouts for SCSI commands (READ, WRITE,
     TEST UNIT READY, etc.) that will likely work in most cases  for  many  tape
     drives.

     For  newer  tape drives that claim to support the SPC-4 standard (SCSI Pri-
     mary Commands 4) or later standards, the sa driver will attempt to use  the
     REPORT  SUPPORTED OPERATION CODES command to fetch timeout descriptors from
     the drive.  If the drive does report timeout  descriptors,  the  sa  driver
     will use the drive's recommended timeouts for commands.

     The  timeouts  in	use are reported in units of thousandths of a second via
     the kern.cam.sa.%d.timeout.* sysctl(8) variables.

     To override either the default timeouts, or the timeouts recommended by the
     drive, you can set one of two sets of loader tunable values.  If you have a
     drive that supports the REPORT SUPPORTED OPERATION CODES  timeout	descrip-
     tors (see the camcontrol(8) opcodes subcommand) it is generally best to use
     those  values.   The  global kern.cam.sa.timeout.* values will override the
     timeouts for all sa driver instances.  If there are 5 tape  drives  in  the
     system,  they'll  all  get the same timeouts.  The kern.cam.sa.%d.timeout.*
     values (where %d is the numeric  sa  instance  number)  will  override  the
     global timeouts as well as either the default timeouts or the timeouts rec-
     ommended by the drive.

     To  set  timeouts after boot, the per-instance timeout values, for example:
     kern.cam.sa.0.timeout.read, are available as sysctl variables.

     If a tape drive arrives after boot, the  global  tunables	or  per-instance
     tunables that apply to the newly arrived drive will be used.

     Loader tunables:

     kern.cam.sa.timeout.erase
     kern.cam.sa.timeout.locate
     kern.cam.sa.timeout.mode_select
     kern.cam.sa.timeout.mode_sense
     kern.cam.sa.timeout.prevent
     kern.cam.sa.timeout.read
     kern.cam.sa.timeout.read_position
     kern.cam.sa.timeout.read_block_limits
     kern.cam.sa.timeout.report_density
     kern.cam.sa.timeout.reserve
     kern.cam.sa.timeout.rewind
     kern.cam.sa.timeout.space
     kern.cam.sa.timeout.tur
     kern.cam.sa.timeout.write
     kern.cam.sa.timeout.write_filemarks

     Loader tunable values and sysctl(8) values:

     kern.cam.sa.%d.timeout.erase
     kern.cam.sa.%d.timeout.locate
     kern.cam.sa.%d.timeout.mode_select
     kern.cam.sa.%d.timeout.mode_sense
     kern.cam.sa.%d.timeout.prevent
     kern.cam.sa.%d.timeout.read
     kern.cam.sa.%d.timeout.read_position
     kern.cam.sa.%d.timeout.read_block_limits
     kern.cam.sa.%d.timeout.report_density
     kern.cam.sa.%d.timeout.reserve
     kern.cam.sa.%d.timeout.rewind
     kern.cam.sa.%d.timeout.space
     kern.cam.sa.%d.timeout.tur
     kern.cam.sa.%d.timeout.write
     kern.cam.sa.%d.timeout.write_filemarks

     As  mentioned  above, the timeouts are set and reported in thousandths of a
     second, so be sure to account for that when setting them.

IOCTLS
     The sa driver supports all of the ioctls of mtio(4).

FILES
     /dev/[n][e]sa[0-9]  general form:
     /dev/sa0		 Rewind on close
     /dev/nsa0		 No rewind on close
     /dev/esa0		 Eject on close (if capable)
     /dev/sa0.ctl	 Control mode device (to  examine  state  while  another
			 program is accessing the device, e.g.).

DIAGNOSTICS
     The sa driver supports injecting End Of Media (EOM) notification to aid ap-
     plication	development and testing.  EOM is indicated to the application by
     returning the read or write with 0 bytes written.	In addition, when EOM is
     injected, the tape position status will be updated to temporarily show  Be-
     yond  of the Programmable Early Warning (BPEW) status.  To see BPEW status,
     use the MTIOCEXTGET ioctl, which is used by the "mt  status"  command.   To
     inject an EOM notification, set the

     kern.cam.sa.%d.inject_eom

     sysctl  variable to 1.  One EOM notification will be sent, BPEW status will
     be set for one position query, and then the driver state will be  reset  to
     normal.

SEE ALSO
     mt(1), cam(4), mtio(4)

AUTHORS
     The sa driver was written for the CAM SCSI subsystem by Justin T. Gibbs and
     Kenneth  Merry.   Many ideas were gleaned from the st device driver written
     and ported from Mach 2.5 by Julian Elischer.

     The owner of record for many years was Matthew Jacob.   The  current  main-
     tainer is Kenneth Merry

BUGS
     This  driver  lacks  many of the hacks required to deal with older devices.
     Many older SCSI-1 devices may not work properly with this driver yet.

     Additionally, certain tapes (QIC tapes  mostly)  that  were  written  under
     FreeBSD  2.X are not automatically read correctly with this driver: you may
     need to explicitly set variable block mode or set	to  the  blocksize  that
     works  best  for  your  device in order to read tapes written under FreeBSD
     2.X.

     Partitions are only supported for	status	information  and  location.   It
     would be nice to add support for creating and editing tape partitions.

FreeBSD 15.1			January 18, 2022			   SA(4)