SMARTD.CONF(5)		     SMART Monitoring Tools		  SMARTD.CONF(5)

NAME
     smartd.conf - SMART Disk Monitoring Daemon Configuration File

DESCRIPTION
     [This  man  page is generated for the FreeBSD version of smartmontools.  It
     does not contain info specific to other platforms.]

     /usr/local/etc/smartd.conf is the configuration file for the smartd daemon.

     If the configuration file	/usr/local/etc/smartd.conf  is	present,  smartd
     reads it at startup.  If smartd subsequently receives a HUP signal, it will
     then  re-read  the configuration file.  If smartd is running in debug mode,
     then an INT signal will also make it re-read the configuration file.   This
     signal  can be generated by typing <CONTROL-C> in the terminal window where
     smartd is running.

     In the absence of a configuration file smartd will try to open  all  avail-
     able  devices (see smartd(8) man page).  A configuration file with a single
     line 'DEVICESCAN -a' would have the same effect.

     This can be annoying if you have an ATA or SCSI device that hangs or misbe-
     haves when receiving SMART commands.  Even if this causes no problems,  you
     may be annoyed by the string of error log messages about devices that can't
     be opened.

     One  can avoid this problem, and gain more control over the types of events
     monitored	by  smartd,   by   using   the	 configuration	 file	/usr/lo-
     cal/etc/smartd.conf.  This file contains a list of devices to monitor, with
     one  device  per  line.  An example file is included with the smartmontools
     distribution.  You will find this sample  configuration  file  in	/usr/lo-
     cal/share/doc/smartmontools/.   For security, the configuration file should
     not be writable by anyone but root.  The syntax of the file is as follows:

     *	 There should be one device listed per line, although you may have lines
	 that are entirely comments or white space.

     *	 Any text following a hash sign '#' and up to the end  of  the	line  is
	 taken to be a comment, and ignored.

     *	 Lines	may be continued by using a backslash '\' as the last non-white-
	 space or non-comment item on a line.

     *	 Note: a line whose first character is a hash sign '#' is treated  as  a
	 white-space blank line, not as a non-existent line, and will end a con-
	 tinuation line.

     Here  is  an  example  configuration  file.  It's for illustrative purposes
     only; please don't copy it onto your system without reading to the  end  of
     the DIRECTIVES Section below!

     ################################################
     # This is an example smartd startup config file
     # /usr/local/etc/smartd.conf
     #
     # On the second disk, start a long self-test every
     # Sunday between 3 and 4 am.
     #
     /dev/sda -a -m admin@example.com,root@localhost
     /dev/sdb -a -I 194 -I 5 -i 12 -s L/../../7/03
     #
     # Send a TEST warning email to admin on startup.
     #
     /dev/sdc -m admin@example.com -M test
     #
     # An ATA disk may appear as a SCSI device to the
     # OS.  If a SCSI to ATA Translation (SAT) layer
     # is between the OS and the device then this can be
     # flagged with the '-d sat' option.
     /dev/sda -a -d sat
     #
     # Disks connected to a MegaRAID controller
     # Start short self-tests daily between 1-2, 2-3, and
     # 3-4 am.
     # FreeBSD:
     /dev/mfi0 -d megaraid,0 -a -s S/../.././01
     /dev/mfi0 -d megaraid,1 -a -s S/../.././02
     /dev/mfi0 -d megaraid,2 -a -s S/../.././03
     /dev/mrsas0 -d megaraid,2 -a -s S/../.././03
     #
     # Two SATA (not SAS) disks on a 3ware 9750 controller.
     # Start long self-tests Sundays between midnight and
     # 1 am and 2-3 am
     # under FreeBSD
     /dev/tws0 -d 3ware,0 -a -s L/../../7/00
     /dev/tws0 -d 3ware,1 -a -s L/../../7/02
     #
     # Three SATA disks on a HighPoint RocketRAID controller.
     # Start short self-tests daily between 1-2, 2-3, and
     # 3-4 am.
     # under FreeBSD
     /dev/hptrr -d hpt,1/1 -a -s S/../.././01
     /dev/hptrr -d hpt,1/2 -a -s S/../.././02
     /dev/hptrr -d hpt,1/3 -a -s S/../.././03
     #
     # Two SATA disks connected to a HighPoint RocketRAID
     # via a pmport device.  Start long self-tests Sundays
     # between midnight and 1 am and 2-3 am.
     # under FreeBSD
     /dev/hptrr -d hpt,1/4/1 -a -s L/../../7/00
     /dev/hptrr -d hpt,1/4/2 -a -s L/../../7/02
     #
     # Three SATA disks connected to an Areca
     # RAID controller.  Start long self-tests Sundays
     # between midnight and 3 am.
     # under FreeBSD
     /dev/arcmsr0 -d areca,1 -a -s L/../../7/00
     /dev/arcmsr0 -d areca,2 -a -s L/../../7/01
     /dev/arcmsr0 -d areca,3 -a -s L/../../7/02
     #
     # The following line enables monitoring of the
     # ATA Error Log and the Self-Test Error Log.
     # It also tracks changes in both Prefailure
     # and Usage Attributes, apart from Attributes
     # 9, 194, and 231, and shows  continued lines:
     #
     /dev/sdd -l error \
	  -l selftest \
	  -t \	       # Attributes not tracked:
	  -I 194 \     # temperature
	  -I 231 \     # also temperature
	  -I 9	       # power-on hours
     #
     ################################################

DEVICESCAN
     If  a  non-comment  entry	in the configuration file is the text string DE-
     VICESCAN in capital letters, then smartd will ignore any remaining lines in
     the configuration file, and will scan for devices.  If  DEVICESCAN  is  not
     followed by any Directives, then '-a' will apply to all devices.

     DEVICESCAN  may optionally be followed by Directives that will apply to all
     devices that are found in the scan.  For example

       DEVICESCAN -m root@example.com

     will scan for all devices, and then monitor them.	It will send  one  email
     warning per device for any problems that are found.

       DEVICESCAN -H -m root@example.com

     will do the same, but only monitors the SMART health status of the devices,
     rather than the default '-a'.

     Multiple  '-d TYPE' options may be specified with DEVICESCAN to combine the
     scan results of more than one TYPE.

     Configuration entries for specific devices may precede the  DEVICESCAN  en-
     try.  For example

       DEFAULT -m root@example.com
       /dev/sda -s S/../.././02
       /dev/sdc -d ignore
       DEVICESCAN -s L/../.././02

     will  scan  for all devices except /dev/sda and /dev/sdc, monitor them, and
     run a long test between 2-3 am every morning.  Device /dev/sda will also be
     monitored, but only a short test will be run.  Device /dev/sdc will be  ig-
     nored.  Warning emails will be sent for all monitored devices.

     A device is ignored by DEVICESCAN if a configuration line with the same de-
     vice  name  exists.  Symbolic links are resolved before this check is done.
     A device name is also ignored if another device with same identify informa-
     tion (vendor, model, firmware version, serial number, WWN) already exists.

     [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] If a  device  only  supports  a
     single  namespace and a configuration line which addresses its namespace id
     already exists, a DEVICESCAN result which does not address a  namespace  is
     also ignored (and vice versa).

DEFAULT SETTINGS
     If  an entry in the configuration file starts with DEFAULT instead of a de-
     vice name, then all directives in this entry are set as  defaults	for  the
     next device entries.

     This configuration:

       DEFAULT -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
       /dev/sda
       /dev/sdb
       /dev/sdc
       DEFAULT -H -m admin@example.com
       /dev/sdd
       /dev/sde -d removable

     has the same effect as:

       /dev/sda -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
       /dev/sdb -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
       /dev/sdc -a -R5! -W 2,40,45 -I 194 -s L/../../7/00 -m admin@example.com
       /dev/sdd -H -m admin@example.com
       /dev/sde -d removable -H -m admin@example.com

CONFIGURATION FILE DIRECTIVES
     The  following are the Directives that may appear following the device name
     or DEVICESCAN or DEFAULT on any line of the /usr/local/etc/smartd.conf con-
     figuration file.  Note that these are NOT command-line options for  smartd.
     The Directives below may appear in any order, following the device name.

     If  no  Directives appear, then the device will be monitored as if the '-a'
     Directive had been given.

     -d TYPE
	    Specifies the type of the device.  The valid arguments to  this  di-
	    rective are:

	    auto - attempt to guess the device type from the device name or from
	    controller	type  info  provided  by  the operating system or from a
	    matching USB ID entry in the drive database.  This is the default.

	    ata - the device type is ATA.  This  prevents  smartd  from  issuing
	    SCSI commands to an ATA device.

	    scsi  -  the device type is SCSI.  This prevents smartd from issuing
	    ATA commands to a SCSI device.

	    nvme[,NSID] - the device type is NVM Express (NVMe).   The	optional
	    parameter  NSID  specifies	the  namespace id (in hex) passed to the
	    driver.  Use 0xffffffff for the broadcast namespace id.  The default
	    for NSID is the namespace id addressed by the device name.

	    sat[,auto][,N] - the device type is SCSI to ATA  Translation  (SAT).
	    This  is  for  ATA	disks  that have a SCSI to ATA Translation Layer
	    (SATL) between the disk and the operating system.  SAT  defines  two
	    ATA  PASS  THROUGH SCSI commands, one 12 bytes long and the other 16
	    bytes long.  The default is the 16 byte variant which can  be  over-
	    ridden with either '-d sat,12' or '-d sat,16'.

	    If	'-d sat,auto' is specified, device type SAT (for ATA/SATA disks)
	    is only used if the SCSI INQUIRY data reports a SATL  (VENDOR:  "ATA
	    ").  Otherwise device type SCSI (for SCSI/SAS disks) is used.

	    usbasm1352r,PORT - [NEW EXPERIMENTAL SMARTD 7.4 FEATURE] this device
	    type  is  for  one	or  two  SATA  disks  that are behind an ASMedia
	    ASM1352R USB to SATA (RAID) bridge.  The parameter PORT (0 or 1) se-
	    lects the disk to monitor.
	    Note: This USB bridge also supports '-d sat'.  This monitors  either
	    the  first	disk  or  the second disk if no disk is connected to the
	    first port.

	    usbcypress - this device type is for ATA disks that are behind a Cy-
	    press USB to PATA bridge.  This will use the ATACB proprietary  scsi
	    pass  through command.  The default SCSI operation code is 0x24, but
	    although it can be overridden with '-d usbcypress,0xN', where  N  is
	    the  scsi  operation  code, you're running the risk of damage to the
	    device or filesystems on it.

	    usbjmicron[,p][,x][,PORT] - this device type is for SATA disks  that
	    are  behind  a JMicron USB to PATA/SATA bridge.  The 48-bit ATA com-
	    mands (required e.g. for '-l xerror', see below) do  not  work  with
	    all  of  these bridges and are therefore disabled by default.  These
	    commands can be enabled by '-d usbjmicron,x'.  If two disks are con-
	    nected to a bridge with two ports, an error message is printed if no
	    PORT (0 or 1) is specified.
	    The PORT parameter is not necessary if the device uses a port multi-
	    plier to connect multiple disks to one port.  The disks appear under
	    separate /dev/ice names then.
	    CAUTION: Specifying ',x' for a device which does not support it  re-
	    sults  in I/O errors and may disconnect the drive.	The same applies
	    if the specified PORT does not exist or is not connected to a disk.

	    The Prolific PL2507/3507 USB bridges with older firmware  support  a
	    pass-through  command  similar  to JMicron and work with '-d usbjmi-
	    cron,0'.  Newer Prolific firmware requires a modified command  which
	    can  be  selected by '-d usbjmicron,p'.  Note that this does not yet
	    support the SMART status command.

	    usbprolific - this device type is for SATA disks that are  behind  a
	    Prolific PL2571/2771/2773/2775 USB to SATA bridge.

	    usbsunplus	-  this  device type is for SATA disks that are behind a
	    SunplusIT USB to SATA bridge.

	    sntasmedia[/sat] - this device type is for NVMe disks that	are  be-
	    hind an ASMedia USB to NVMe bridge.
	    [NEW EXPERIMENTAL SMARTD 7.5 FEATURE] If the '/sat' suffix is speci-
	    fied and the NVMe Identify Controller command fails, the device type
	    is	changed  to '-d sat'.  This is useful for USB M.2 adapters which
	    support NVMe and SATA devices.

	    sntjmicron[,NSID][/sat] - this device type is for  NVMe  disks  that
	    are  behind  a  JMicron  USB to NVMe bridge.  The optional parameter
	    NSID specifies the namespace id (in hex) passed to the driver.   The
	    default  namespace	id  is	the broadcast namespace id (0xffffffff).
	    See also '-d sntasmedia' for the '/sat' suffix.

	    sntrealtek[/sat] - this device type is for NVMe disks that	are  be-
	    hind a Realtek USB to NVMe bridge.	See also '-d sntasmedia' for the
	    '/sat' suffix.

	    megaraid,N	- [FreeBSD and Linux only] the device consists of one or
	    more SCSI/SAS disks connected to a MegaRAID  controller.   The  non-
	    negative  integer  N  (in  the  range of 0 to 127 inclusive) denotes
	    which disk on the controller is monitored.	This interface will also
	    work for Dell PERC controllers.  In log  files  and  email	messages
	    this  disk	will  be identified as megaraid_disk_XXX with XXX in the
	    range from 000 to 127 inclusive.  Please  see  the	smartctl(8)  man
	    page for further details.

	    3ware,N  -	[FreeBSD  and  Linux only] the device consists of one or
	    more ATA disks connected to a 3ware RAID controller.  The  non-nega-
	    tive  integer N (in the range from 0 to 127 inclusive) denotes which
	    disk on the controller is monitored.  In log files	and  email  mes-
	    sages this disk will be identified as 3ware_disk_XXX with XXX in the
	    range from 000 to 127 inclusive.

	    Note  that	while  you may use any of the 3ware SCSI logical devices
	    /dev/tw* to address any of the physical disks (3ware  ports),  error
	    and  log  messages	will  make the most sense if you always list the
	    3ware SCSI logical device corresponding to the  particular	physical
	    disks.  Please see the smartctl(8) man page for further details.

	    areca,N  - [FreeBSD, Linux, Windows and Cygwin only] the device con-
	    sists of one or more SATA disks connected to an Areca SATA RAID con-
	    troller.  The positive integer N (in the range from 1 to  24  inclu-
	    sive)  denotes  which  disk  on the controller is monitored.  In log
	    files  and	email  messages  this  disk  will   be	 identified   as
	    areca_disk_XX  with XX in the range from 01 to 24 inclusive.  Please
	    see the smartctl(8) man page for further details.

	    areca,N/E - [FreeBSD, Linux, Windows and  Cygwin  only]  the  device
	    consists  of one or more SATA or SAS disks connected to an Areca SAS
	    RAID controller.  The integer N (range 1 to 128) denotes the channel
	    (slot) and E (range 1 to 8) denotes the enclosure.	Important:  This
	    requires Areca SAS controller firmware version 1.51 or later.

	    cciss,N  -	[FreeBSD  and  Linux only] the device consists of one or
	    more SCSI/SAS or SATA disks connected to a	cciss  RAID  controller.
	    The  non-negative  integer	N (in the range from 0 to 127 inclusive)
	    denotes which disk on the controller is monitored.	In log files and
	    email messages this disk will be identified as cciss_disk_XX with XX
	    in the range from 00 to 127 inclusive.  Please see	the  smartctl(8)
	    man page for further details.

	    hpt,L/M/N  -  [FreeBSD and Linux only] the device consists of one or
	    more ATA disks connected to a HighPoint RocketRAID controller.   The
	    integer L is the controller id, the integer M is the channel number,
	    and  the integer N is the PMPort number if it is available.  The al-
	    lowed values of L are from 1 to 4 inclusive, M are from 1 to 128 in-
	    clusive and N from 1 to 4 if PMPort available.  And also these  val-
	    ues are limited by the model of the HighPoint RocketRAID controller.
	    In	log  files  and  email	messages this disk will be identified as
	    hpt_X/X/X and X/X/X is the same as L/M/N, note if no N indicated,  N
	    set to the default value 1.  Please see the smartctl(8) man page for
	    further details.

	    intelliprop,N[+TYPE] - (deprecated and subject to remove).

	    jmb39x[-q[2]],N[,sLBA][,force][+TYPE]  - the device consists of mul-
	    tiple SATA disks connected to a JMicron JMB39x RAID port multiplier.
	    The suffix '-q' selects a slightly different command variant used by
	    QNAP TR-004 NAS devices.  The integer N is the port number from 0 to
	    4.
	    [NEW EXPERIMENTAL SMARTD 7.5 FEATURE] The suffix '-q2'  selects  an-
	    other  command  variant used by QNAP TR-002 NAS devices.  Please see
	    the smartctl(8) man page for further details.

	    jms56x,N[,sLBA][,force][+TYPE] - the  device  consists  of	multiple
	    SATA  disks  connected  to a JMicron JMS56x USB to SATA RAID bridge.
	    See 'jmb39x...' above for valid arguments.

	    ignore - the device specified by this configuration entry should  be
	    ignored.   This  allows one to ignore specific devices which are de-
	    tected by a following DEVICESCAN configuration line.  It may also be
	    used to temporary disable longer multi-line  configuration	entries.
	    This Directive may be used in conjunction with the other '-d' Direc-
	    tives.

	    removable - the device or its media is removable.  This indicates to
	    smartd that it should continue (instead of exiting, which is the de-
	    fault  behavior)  if  the  device does not appear to be present when
	    smartd is started.	This directive also  suppresses  warning  emails
	    and  repeated  log	messages if the device is removed after startup.
	    This Directive may be used in conjunction with the other '-d' Direc-
	    tives.
	    WARNING: Removing a device and connecting a different  one	to  same
	    interface  is  not	supported and may result in bogus warnings until
	    smartd is restarted.

     -n POWERMODE[,N][,q]
	    [ATA only] This 'nocheck' Directive is used to prevent a  disk  from
	    being spun-up when it is periodically polled by smartd.

	    ATA  disks have five different power states.  In order of increasing
	    power consumption they are: 'OFF', 'SLEEP', 'STANDBY',  'IDLE',  and
	    'ACTIVE'.  Typically in the OFF, SLEEP, and STANDBY modes the disk's
	    platters  are  not spinning.  But usually, in response to SMART com-
	    mands issued by smartd, the disk platters are spun up.  So	if  this
	    option  is not used, then a disk which is in a low-power mode may be
	    spun up and put into a higher-power mode  when  it	is  periodically
	    polled by smartd.

	    Note  that if the disk is in SLEEP mode when smartd is started, then
	    it won't respond to smartd commands, and so the disk won't be regis-
	    tered as a device for smartd to monitor.  If a disk is in any  other
	    low-power  mode,  then the commands issued by smartd to register the
	    disk will probably cause it to spin-up.

	    The '-n' (nocheck) Directive specifies if smartd's	periodic  checks
	    should  still be carried out when the device is in a low-power mode.
	    It may be used to prevent a disk  from  being  spun-up  by	periodic
	    smartd polling.  The allowed values of POWERMODE are:

	    never  - smartd will poll (check) the device regardless of its power
	    mode.  This may cause a disk which is spun-down to be  spun-up  when
	    smartd  checks  it.  This is the default behavior if the '-n' Direc-
	    tive is not given.

	    sleep - check the device unless it is in SLEEP mode.

	    standby - check the device unless it is in SLEEP  or  STANDBY  mode.
	    In	these  modes most disks are not spinning, so if you want to pre-
	    vent a laptop disk from spinning up each  time  that  smartd  polls,
	    this is probably what you want.

	    idle - check the device unless it is in SLEEP, STANDBY or IDLE mode.
	    In	the IDLE state, most disks are still spinning, so this is proba-
	    bly not what you want.

	    Maximum number of skipped checks (in a row) can be specified by  ap-
	    pending  positive  number  ',N' to POWERMODE (like '-n standby,15').
	    After N checks are skipped in a row, powermode is  ignored	and  the
	    check is performed anyway.

	    When  a periodic test is skipped, smartd normally writes an informal
	    log message.  The message can be suppressed by appending the  option
	    ',q'  to  POWERMODE  (like	'-n standby,q').  This prevents a laptop
	    disk from spinning up due to this message.

	    Both ',N' and ',q' can be specified together.

     -T TYPE
	    Specifies how tolerant smartd should be of SMART  command  failures.
	    The valid arguments to this Directive are:

	    normal - do not try to monitor the disk if a mandatory SMART command
	    fails, but continue if an optional SMART command fails.  This is the
	    default.

	    permissive	-  try	to  monitor  the disk even if it appears to lack
	    SMART capabilities.  This may be required for some old disks  (prior
	    to	ATA-3  revision 4) that implemented SMART before the SMART stan-
	    dards were incorporated into the ATA/ATAPI Specifications.	 [Please
	    see the smartctl -T command-line option.]

     -o VALUE
	    [ATA  only] Enables or disables SMART Automatic Offline Testing when
	    smartd starts up and has no further effect.  The valid arguments  to
	    this Directive are on and off.

	    The  delay	between  tests is vendor-specific, but is typically four
	    hours.

	    Note that SMART Automatic Offline Testing is not  part  of	the  ATA
	    Specification.  Please see the smartctl -o command-line option docu-
	    mentation for further information about this feature.

     -S VALUE
	    Enables or disables Attribute Autosave when smartd starts up and has
	    no further effect.	The valid arguments to this Directive are on and
	    off.   Also  affects SCSI devices.	[Please see the smartctl -S com-
	    mand-line option.]

     -H [MASK]
	    Check the health status of the disk.  If the disk reports a  failing
	    health status, a message at loglevel LOG_CRIT will be logged to sys-
	    log.  [Please see the smartctl -H command-line option.]

	    [ATA]  Checks the (boolean) result returned by the SMART RETURN STA-
	    TUS command.  The optional parameter MASK is ignored.

	    [SCSI] Checks the Additional Sense Code (ASC) and  Additional  Sense
	    Code  Qualifier  (ASCQ)  from  Informal Exceptions (IE) log page (if
	    supported) and/or from SCSI sense data.  The optional parameter MASK
	    is ignored.
	    Note: for historical reasons, this check is always done for SCSI de-
	    vices, regardless of the '-H' directive.

	    [NVMe] Checks the "Critical Warning" byte from the SMART/Health  In-
	    formation  log.   If  any  warning bit is set, a message at loglevel
	    LOG_CRIT will be logged to syslog.
	    [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] If the optional  parame-
	    ter  MASK  (hexadecimal)  is  specified, the check is limited to the
	    warning bits set in MASK.  For example if '-H  0xf9'  is  specified,
	    the warning bit 1 ("temperature out of range") and bit 2 ("reliabil-
	    ity degraded") will be ignored.  '-H 0xff' is the same as '-H' with-
	    out a parameter.

     -l TYPE
	    Reports  increases	in  the  number  of errors in one of three SMART
	    logs.  The valid arguments to this Directive are:

	    error - [ATA] report if the number of ATA  errors  reported  in  the
	    Summary SMART error log has increased since the last check.

	    error  -  [NVMe]  report if the "Number of Error Information Log En-
	    tries" from the SMART/Health Information log has increased since the
	    last check.
	    [NEW EXPERIMENTAL SMARTD 7.4 FEATURE] This will only  be  logged  as
	    LOG_CRIT  if  at least one of the new errors is still present in the
	    Error Information log and its status indicates a device related  er-
	    ror.   Up  to eight of the most recent of these errors are logged as
	    LOG_INFO then.  This is useful because the	NVMe  Error  Information
	    log is not persistent across power cycles or device resets.
	    If all new errors are either no longer present in the log or are not
	    device  related  (e.g.  invalid  command,  invalid field in command,
	    ...), a LOG_INFO message is generated instead.  This avoids mislead-
	    ing warnings if the operating system issues unsupported commands and
	    the device firmware also logs these kind of errors.

	    xerror - [ATA] report if the number of ATA errors  reported  in  the
	    Extended  Comprehensive SMART error log has increased since the last
	    check.

	    If both '-l error' and '-l xerror' are specified, smartd checks  the
	    maximum of both values.

	    [Please see the smartctl -l xerror command-line option.]

	    xerror - [NVMe] same as '-l error'.

	    selftest  - [ATA] [SCSI] [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE]
	    report if the number of failed tests reported in the SMART Self-Test
	    Log has increased since the last check, or if the timestamp  associ-
	    ated with the most recent failed test has increased.  Note that such
	    errors will only be logged if you run self-tests on the disk (and it
	    fails  a  test!).	Self-Tests  can  be run automatically by smartd:
	    please see the '-s' Directive below.  Self-Tests  can  also  be  run
	    manually  by  using the '-t short' and '-t long' options of smartctl
	    and the results of the testing can be observed  using  the	smartctl
	    '-l selftest'  command-line option.  [Please see the smartctl -l and
	    -t command-line options.]

	    [ATA] [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] Failed  self-tests
	    outdated  by a newer successful extended self-test are ignored.  The
	    warning email counter is reset if the number of  failed  self  tests
	    dropped  to 0.  This typically happens when an extended self-test is
	    run after all bad blocks have been reallocated.

	    [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] If the device  name  ad-
	    dresses  an  individual  namespace, log entries with different name-
	    space ids are ignored.  Entries with unspecified or broadcast  name-
	    space id are always checked.

	    offlinests[,ns]  -	[ATA only] report if the Offline Data Collection
	    status has changed since the last check.  The report will be  logged
	    as	LOG_CRIT if the new status indicates an error.	With some drives
	    the status often changes, therefore '-l offlinests' is  not  enabled
	    by	'-a'  Directive.  Appending ',ns' (no standby) to this directive
	    is not implemented on FreeBSD.

	    selfteststs[,ns] - [ATA] [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE]
	    report if the Self-Test execution status has changed since the  last
	    check.   The report will be logged as LOG_CRIT if the new status in-
	    dicates an error.  Appending ',ns' (no standby) to this directive is
	    not implemented on FreeBSD.

	    scterc,READTIME,WRITETIME - [ATA only] sets the SCT  Error	Recovery
	    Control  settings  to the specified values (deciseconds) when smartd
	    starts up and has no further effect.  Values of 0 disable  the  fea-
	    ture,  other  values  less	than 65 are probably not supported.  For
	    RAID configurations, this is typically  set  to  70,70  deciseconds.
	    [Please see the smartctl -l scterc command-line option.]

     -e NAME[,VALUE]
	    Sets non-SMART device settings when smartd starts up and has no fur-
	    ther  effect.   [Please see the smartctl --set command-line option.]
	    Valid arguments are:

	    aam,[N|off] - [ATA only]  Sets  the  Automatic  Acoustic  Management
	    (AAM) feature.

	    apm,[N|off]  -  [ATA  only] Sets the Advanced Power Management (APM)
	    feature.

	    lookahead,[on|off] - [ATA only] Sets the read look-ahead feature.

	    security-freeze - [ATA only] Sets ATA  Security  feature  to  frozen
	    mode.

	    standby,[N|off]  -	[ATA only] Sets the standby (spindown) timer and
	    places the drive in the IDLE mode.

	    wcache,[on|off] - [ATA only] Sets the volatile write cache feature.

	    dsn,[on|off] - [ATA only] Sets the DSN feature.

     -s REGEXP
	    Run Self-Tests or Offline Immediate Tests, at  scheduled  times.   A
	    Self-  or  Offline Immediate Test will be run at the end of periodic
	    device polling, if all 12  characters  of  the  string  T/MM/DD/d/HH
	    match the extended regular expression REGEXP.  Here:

	    T	is  the  type  of  the test.  The values that smartd will try to
		match (in turn) are: 'L' for a Long Self-Test, 'S' for	a  Short
		Self-Test,  'C'  for  a Conveyance Self-Test (ATA only), and 'O'
		for an Offline Immediate Test (ATA only).  As soon as a match is
		found, the test will be started and no additional  matches  will
		be sought for that device and that polling cycle.

		[NVMe:	NEW  EXPERIMENTAL  SMARTD  7.5 FEATURE] For NVMe devices
		with Self-Test support, use 'L'  to  start  an	"Extended"  NVMe
		Self-Test  and	'S'  for  a Short NVMe Self-Test.  If the device
		name addresses an individial namespace, the test will be started
		using this namespace id, otherwise using the broadcast namespace
		id.

		[ATA only] To run scheduled Selective Self-Tests,  use	'n'  for
		next  span,  'r' to redo last span, or 'c' to continue with next
		span or redo last span based on status of last	test.	The  LBA
		range  is  based  on the first span from the last test.  See the
		smartctl -t select,[next|redo|cont] options for further info.

		Some disks (e.g. WD) do not preserve the selective self test log
		across power cycles.  If state persistence ('-s' option) is  en-
		abled,	the  last  test  span is preserved by smartd and used if
		(and only if) the selective self test log is empty.

	    MM	is the month of the year, expressed  with  two	decimal  digits.
		The  range  is from 01 (January) to 12 (December) inclusive.  Do
		not use a single decimal digit or the match will always fail!

	    DD	is the day of the month, expressed with two decimal digits.  The
		range is from 01 to 31 inclusive.  Do not use a  single  decimal
		digit or the match will always fail!

	    d	is  the  day of the week, expressed with one decimal digit.  The
		range is from 1 (Monday) to 7 (Sunday) inclusive.

	    HH	is the hour of the day, written with  two  decimal  digits,  and
		given  in  hours  after  midnight.  The range is 00 (midnight to
		just before 1 am) to 23 (11pm to just  before  midnight)  inclu-
		sive.	Do  not use a single decimal digit or the match will al-
		ways fail!

	    If the regular expression contains substrings of the  form	:NNN  or
	    :NNN-LLL,  where  NNN  and	LLL  are three decimal digits, staggered
	    tests are enabled.	Then a test will also be run if all 16	(or  20)
	    characters	of the string T/MM/DD/d/HH:NNN (or T/MM/DD/d/HH:NNN-LLL)
	    match the regular expression.  This check is done for  up  to  seven
	    :NNN or :NNN-LLL found in the regular expression.  The time used for
	    the check is adjusted to the past such that tests of the first drive
	    are not delayed, tests of the second drive are delayed by NNN hours,
	    tests of the third drive are delayed by 2*NNN hours, and so on.
	    If	LLL is also specified, delays are limited to LLL hours by calcu-
	    lating each individual delay as:
	    '((DRIVE_INDEX * NNN) mod (LLL + 1))'.

	    Some examples follow.  In reading these, keep in mind  that  in  ex-
	    tended  regular  expressions a dot '.' matches any single character,
	    and a parenthetical expression such as '(A|B|C)' denotes any one  of
	    the three possibilities A, B, or C.

	    To schedule a short Self-Test between 2-3 am every morning, use:
	     -s S/../.././02
	    To	schedule  a  long Self-Test between 4-5 am every Sunday morning,
	    use:
	     -s L/../../7/04
	    To enable staggered tests with delays in three hour steps, use:
	     -s L/../../7/04:003
	    To enable staggered tests with delays 0, 3, 6, 9, 1, 4, 7, 10, 2, 5,
	    8, 0, ... hours, use:
	     -s L/../../7/04:003-010
	    To enable staggered tests with delays 0, 1, 2, ..., 9,  10,  0,  ...
	    hours, use:
	     -s L/../../7/04:001-010
	    To	schedule a long Self-Test between 10-11 pm on the first and fif-
	    teenth day of each month, use:
	     -s L/../(01|15)/./22
	    To schedule an Offline Immediate test after every  midnight,  6  am,
	    noon,  and	6  pm, plus a Short Self-Test daily at 1-2 am and a Long
	    Self-Test every Saturday at 3-4 am, use:
	     -s (O/../.././(00|06|12|18)|S/../.././01|L/../../6/03)
	    To enable staggered Long Self-Tests with delays in three hour steps,
	    use:
	     -s (O/../.././(00|06|12|18)|S/../.././01|L/../../6/03:003)
	    If Long Self-Tests of a large disks take longer than the system  up-
	    time,  a  full disk test can be performed by several Selective Self-
	    Tests.  To setup a full test of a 1 TB disk within 20 days	(one  50
	    GB span each day), run this command once:
	      smartctl -t select,0-99999999 /dev/sda
	    To	run  the  next test spans on Monday-Friday between 12-13 am, run
	    smartd with this directive:
	     -s n/../../[1-5]/12

	    Scheduled tests are run immediately following  the	regularly-sched-
	    uled device polling, if the current local date, time, and test type,
	    match REGEXP.  By default the regularly-scheduled device polling oc-
	    curs  every  thirty  minutes after starting smartd.  Take caution if
	    you use the '-i' option to make  this  polling  interval  more  than
	    sixty  minutes:  the poll times may fail to coincide with any of the
	    testing times that you have specified with REGEXP.	In this case the
	    test will be run following the next device polling.

	    Before running an offline or self-test, smartd  checks  to	be  sure
	    that  a self-test is not already running.  If a self-test is already
	    running, then this running self test will not be interrupted to  be-
	    gin another test.

	    smartd  will not attempt to run any type of test if another test was
	    already started or run in the same hour.

	    To avoid performance problems during system boot,  smartd  will  not
	    attempt  to  run any scheduled tests following the very first device
	    polling (unless '-q onecheck' is specified).

	    Each time a test is run, smartd will log an entry  to  SYSLOG.   You
	    can  use  these  or the '-q showtests' command-line option to verify
	    that you constructed REGEXP correctly.  The matching order (L before
	    S before C before O) ensures that if multiple  test  types	are  all
	    scheduled  for  the  same hour, the longer test type has precedence.
	    This is usually the desired behavior.

	    If the scheduled tests are used in conjunction  with  state  persis-
	    tence  ('-s'  option), smartd will also try to match the hours since
	    last shutdown (or 90 days at most).  If any  test  would  have  been
	    started  during  downtime, the longest (see above) of these tests is
	    run after second device polling.

	    If the '-n' directive is used and any test would have  been  started
	    during disk standby time, the longest of these tests is run when the
	    disk is active again.

	    Unix  users:  please  beware that the rules for extended regular ex-
	    pressions [regex(7)] are not the same as  the  rules  for  file-name
	    pattern matching by the shell [glob(7)].  smartd will issue harmless
	    informational  warning  messages  if it detects characters in REGEXP
	    that appear to indicate that you have made this mistake.

     -m ADD
	    Send a warning email to the email address ADD if the '-H',	'-l  er-
	    ror',  '-l	xerror', '-l selftest', '-f', '-C', '-U', or '-W' Direc-
	    tives detect a failure or a new error, or if a SMART command to  the
	    disk  fails.   This  Directive  only works in conjunction with these
	    other Directives (or with the equivalent default '-a' Directive).

	    To prevent your email in-box from getting  filled  up  with  warning
	    messages,  by  default  only a single warning and (depending on '-s'
	    option) daily reminder emails will be sent for each of  the  enabled
	    alert types.  See the '-M' Directive below for details.

	    To send email to more than one user, please use the following "comma
	    separated"		form	      for	   the		address:
	    user1@add1,user2@add2,...,userN@addN (with no spaces).

	    To test that email is being sent correctly, use the '-M test' Direc-
	    tive described below to  send  one	test  email  message  on  smartd
	    startup.

	    By	default, email is sent using the system mail(1) command.  In or-
	    der that smartd find this command (normally /usr/bin/mail) the  exe-
	    cutable  must  be in the path of the shell or environment from which
	    smartd was started.  If you wish to specify an explicit path to  the
	    mail executable (for example /usr/local/bin/mail) or a custom script
	    to run, please use the '-M exec' Directive below.

	    Note  also	that there is a special argument <nomailer> which can be
	    given to the '-m' Directive in conjunction with the '-M exec' Direc-
	    tive.  Please see below for an explanation of its effect.

	    If the mailer or the shell running	it  produces  any  STDERR/STDOUT
	    output, then a snippet of that output will be copied to SYSLOG.  The
	    remainder  of  the output is discarded.  If problems are encountered
	    in sending mail, this should help you to understand  and  fix  them.
	    If you have mail problems, we recommend running smartd in debug mode
	    with the '-d' flag, using the '-M test' Directive described below.

	    If a word of the comma separated list has the form '@plugin', a cus-
	    tom  script  /usr/local/etc/smartd_warning.d/plugin  is  run and the
	    word is removed from the list before sending mail.	The string 'plu-
	    gin' may be any valid name except 'ALL'.  If  '@ALL'  is  specified,
	    all  scripts  in  /usr/local/etc/smartd_warning.d/* are run instead.
	    This is handled by the script /usr/local/etc/smartd_warning.sh  (see
	    also  '-M  exec'  below).  Plugin scripts without execute permission
	    are silently ignored.  If any plugin script is missing or fails with
	    a nonzero exit status, the warning script exits immediately  without
	    sending mail.

     -M TYPE
	    These  Directives  modify  the behavior of the smartd email warnings
	    enabled with the '-m' email Directive described above.   These  '-M'
	    Directives	only work in conjunction with the '-m' Directive and can
	    not be used without it.

	    Multiple -M Directives may be given.  If more than one of  the  fol-
	    lowing  three  -M  Directives  are given (example: -M once -M daily)
	    then the final one (in the example, -M daily) is used.

	    The valid arguments to the -M Directive are (one  of  the  following
	    three):

	    once - send only one warning email for each type of disk problem de-
	    tected.   This is the default unless state persistence ('-s' option)
	    is enabled.

	    always - [NEW EXPERIMENTAL SMARTD 7.4 FEATURE] send additional warn-
	    ing reminder emails, upon each check, for each type of disk  problem
	    detected.

	    daily  -  send additional warning reminder emails, once per day, for
	    each type of disk problem detected.  This is the  default  if  state
	    persistence ('-s' option) is enabled.

	    diminishing  - send additional warning reminder emails, after a one-
	    day interval, then a two-day interval, then a four-day interval, and
	    so on for each type of disk  problem  detected.   Each  interval  is
	    twice as long as the previous interval.
	    [NEW  EXPERIMENTAL SMARTD 7.4 FEATURE] The interval length will stay
	    at 32 days after 5 warning reminder emails.

	    If a disk problem is no longer detected, the internal email  counter
	    is	reset.	If the problem reappears a new warning email is sent im-
	    mediately.

	    In addition, one may add zero or more of the following Directives:

	    test - send a single test email  immediately  upon	smartd	startup.
	    This  allows  one to verify that email is delivered correctly.  Note
	    that if this Directive is used, smartd will  also  send  the  normal
	    email  warnings  that were enabled with the '-m' Directive, in addi-
	    tion to the single test email!

	    exec PATH - run the executable PATH instead of the default mail com-
	    mand, when smartd needs to send email.  PATH must point to	an  exe-
	    cutable binary file or script.

	    By setting PATH to point to a customized script, you can make smartd
	    perform  useful  tricks when a disk problem is detected (beeping the
	    console, shutting down the machine,  broadcasting  warnings  to  all
	    logged-in  users,  etc.)   But please be careful.  smartd will block
	    until the executable PATH returns, so if your executable hangs, then
	    smartd will also hang.  Some sample scripts are included in /usr/lo-
	    cal/share/doc/smartmontools/examplescripts/.

	    The exit status of the executable is recorded by smartd  in  SYSLOG.
	    The  executable is not expected to write to STDOUT or STDERR.  If it
	    does, then this is interpreted as indicating that something is going
	    wrong with your executable, and a fragment of this output is  logged
	    to	SYSLOG	to help you to understand the problem.	Normally, if you
	    wish to leave some record behind, the executable should send mail or
	    write to a file or device.

	    Before running the executable, smartd sets a number  of  environment
	    variables.	 These	environment variables may be used to control the
	    executable's behavior.  The environment variables exported by smartd
	    are:

	    SMARTD_MAILER
		is set to the argument of -M exec, if present or else to  'mail'
		(examples: /usr/local/bin/mail, mail).

	    SMARTD_DEVICE
		is set to the device path (example: /dev/sda).

	    SMARTD_DEVICETYPE
		is  set to the device type specified by '-d' directive or 'auto'
		if none.

	    SMARTD_DEVICESTRING
		is set to the device description.  It starts with  SMARTD_DEVICE
		and  may  be  followed	by an optional controller identification
		(example: /dev/sda [SAT]).  The string may contain a  space  and
		is NOT quoted.

	    SMARTD_DEVICEINFO
		is  set to device identify information.  It includes most of the
		info printed by smartctl -i but uses a brief single line format.
		This device info is also logged  when  smartd  starts  up.   The
		string contains space characters and is NOT quoted.

	    SMARTD_FAILTYPE
		gives the reason for the warning or message email.  The possible
		values that it takes and their meanings are:
		EmailTest: this is an email test message.
		Health: the SMART health status indicates imminent failure.
		Usage: a usage Attribute has failed.
		SelfTest: the number of self-test failures has increased.
		ErrorCount:  the  number  of errors in the ATA error log has in-
		creased.
		CurrentPendingSector: one of more disk sectors could not be read
		and are marked to be reallocated (replaced with spare sectors).
		OfflineUncorrectableSector: during off-line  testing,  or  self-
		testing, one or more disk sectors could not be read.
		Temperature:  Temperature  reached critical limit (see -W direc-
		tive).
		FailedHealthCheck: the SMART health status command failed.
		FailedReadSmartData: the command to read  SMART  Attribute  data
		failed.
		FailedReadSmartErrorLog: the command to read the SMART error log
		failed.
		FailedReadSmartSelfTestLog:  the command to read the SMART self-
		test log failed.
		FailedOpenDevice: the open() command to the device failed.

	    SMARTD_ADDRESS
		is determined by the address argument ADD of the '-m' Directive.
		If ADD is <nomailer>, then SMARTD_ADDRESS is  not  set.   Other-
		wise,  it  is set to the comma-separated-list of email addresses
		given by the argument ADD, with the commas  replaced  by  spaces
		(example:admin@example.com  root).   If  more than one email ad-
		dress is given, then this string will contain  space  characters
		and  is  NOT quoted, so to use it in a shell script you may want
		to enclose it in double quotes.

	    SMARTD_ADDRESS_ORIG
		is set to the original value of  SMARTD_ADDRESS  with  '@plugin'
		strings still present.	If there are no such strings in the '-m'
		Directive, this variable is NOT set.

	    SMARTD_MESSAGE
		is  set to the one sentence summary warning email message string
		from smartd.  This message string contains space characters  and
		is  NOT quoted.  So to use $SMARTD_MESSAGE in a shell script you
		should probably enclose it in double quotes.

	    SMARTD_FULLMESSAGE
		is set to the contents	of  the  entire  email	warning  message
		string	from smartd.  This message string contains space and re-
		turn characters and is NOT quoted.  So to  use	$SMARTD_FULLMES-
		SAGE  in a shell script you should probably enclose it in double
		quotes.

	    SMARTD_TFIRST
		is a text string giving the time and date  at  which  the  first
		problem  of  this  type was reported.  This text string contains
		space characters and no newlines, and is NOT quoted.  For  exam-
		ple:
		Sun Feb  9 14:58:19 2003 CST

	    SMARTD_TFIRSTEPOCH
		is  an integer, which is the unix epoch (number of seconds since
		Jan 1, 1970) for SMARTD_TFIRST.

	    SMARTD_PREVCNT
		is an integer specifying the number of previous  messages  sent.
		It is set to '0' for the first message.

	    SMARTD_NEXTDAYS
		is  an integer specifying the number of days until the next mes-
		sage will be sent.  It is set to empty on '-M once', set to  '0'
		on '-M always' and set to '1' on '-M daily'.

	    If	the  '-m ADD' Directive is given with a normal address argument,
	    then the executable pointed to by PATH will be run in a  shell  with
	    STDIN  receiving  the  body  of the email message, and with the same
	    command-line arguments:
	      -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS
	    that would normally be provided to 'mail'.	Examples include:
	    -m user@home -M exec /usr/bin/mail
	    -m admin@work -M exec /usr/local/bin/mailto
	    -m root -M exec /Example_1/shell/script/below

	    If the '-m ADD' Directive is given with the special address argument
	    <nomailer> then the executable pointed to by PATH is run in a  shell
	    with no STDIN and no command-line arguments, for example:
	      -m <nomailer> -M exec /Example_2/shell/script/below

	    If the executable produces any STDERR/STDOUT output, then smartd as-
	    sumes  that  something  is going wrong, and a snippet of that output
	    will be copied to SYSLOG.  The remainder of the output is then  dis-
	    carded.

	    Some  EXAMPLES of scripts that can be used with the '-M exec' Direc-
	    tive are given below.  Some sample	scripts  are  also  included  in
	    /usr/local/share/doc/smartmontools/examplescripts/.

	    The  executable  is  run  by  the script /usr/local/etc/smartd_warn-
	    ing.sh.  This script formats  subject  and	full  message  based  on
	    SMARTD_MESSAGE  and  other environment variables set by smartd.  The
	    environment variables SMARTD_SUBJECT and SMARTD_FULLMESSAGE are  set
	    by the script before running the executable.

     -f     [ATA] Check for 'failure' of any Usage Attributes.	If these Attrib-
	    utes  are  less than or equal to the threshold, it does NOT indicate
	    imminent disk failure.  It "indicates an  advisory	condition  where
	    the usage or age of the device has exceeded its intended design life
	    period." [Please see the smartctl -A command-line option.]

	    [NVMe:  NEW  EXPERIMENTAL  SMARTD  7.5  FEATURE]  Log a message with
	    LOG_CRIT level and send a warning email if	the  SMART/Health  value
	    "Percentage  Used"	has changed and exceeds 95 percent or "Media and
	    Data Integrity Errors" has increased.

     -p     [ATA] Report anytime that a Prefail Attribute has changed its  value
	    since  the last check.  [Please see the smartctl -A command-line op-
	    tion.]

	    [NVMe: NEW EXPERIMENTAL SMARTD 7.5 FEATURE] Report anytime that  the
	    SMART/Health value "Available Spare" has changed its value since the
	    last  check.   This will be logged with LOG_CRIT level and a warning
	    email will be sent if the value is below  "Available  Spare  Thresh-
	    old".

     -u     [ATA]  Report  anytime  that a Usage Attribute has changed its value
	    since the last check.  [Please see the smartctl -A command-line  op-
	    tion.]

	    [NVMe:  NEW EXPERIMENTAL SMARTD 7.5 FEATURE] Report anytime that the
	    SMART/Health value "Percentage Used" or "Media  and  Data  Integrity
	    Errors" has changed its value since the last check.

     -t     Equivalent to turning on the two previous flags '-p' and '-u'.

     -i ID  [ATA only] Ignore device Attribute number ID when checking for fail-
	    ure  of Usage Attributes.  ID must be a decimal integer in the range
	    from 1 to 255.  This Directive modifies the behavior of the '-f' Di-
	    rective and has no effect without it.

	    This is useful, for example, if you have a very old disk  and  don't
	    want  to keep getting messages about the hours-on-lifetime Attribute
	    (usually Attribute 9) failing.  This Directive may	appear	multiple
	    times  for	a  single device, if you want to ignore multiple Attrib-
	    utes.

     -I ID  [ATA only] Ignore device Attribute ID when tracking changes  in  the
	    Attribute  values.	ID must be a decimal integer in the range from 1
	    to 255.  This Directive modifies the behavior of the '-p', '-u', and
	    '-t' tracking Directives and has no effect without one of them.

	    This is useful, for example, if one of the device Attributes is  the
	    disk  temperature  (usually Attribute 194 or 231).	It's annoying to
	    get reports each time the temperature changes.  This  Directive  may
	    appear  multiple  times  for  a single device, if you want to ignore
	    multiple Attributes.

     -r ID[!]
	    [ATA only] When tracking, report the Raw value of Attribute ID along
	    with its (normally reported) Normalized value.  ID must be a decimal
	    integer in the range from 1 to 255.  This Directive modifies the be-
	    havior of the '-p', '-u', and '-t' tracking Directives  and  has  no
	    effect  without  one  of them.  This Directive may be given multiple
	    times.

	    A common use of this Directive is to track	the  device  Temperature
	    (often ID=194 or 231).

	    If	the  optional  flag  '!' is appended, a change of the Normalized
	    value is considered critical.  The report will be logged as LOG_CRIT
	    and a warning email will be sent if '-m' is specified.

     -R ID[!]
	    [ATA only] When tracking, report whenever the Raw value of Attribute
	    ID changes.  (Normally smartd only	tracks/reports	changes  of  the
	    Normalized	Attribute  values.)  ID must be a decimal integer in the
	    range from 1 to 255.  This Directive modifies the  behavior  of  the
	    '-p',  '-u',  and '-t' tracking Directives and has no effect without
	    one of them.  This Directive may be given multiple times.

	    If this Directive is given, it automatically implies the '-r' Direc-
	    tive for the same Attribute, so that the Raw value of the  Attribute
	    is reported.

	    A  common  use  of this Directive is to track the device Temperature
	    (often ID=194 or 231).  It is also useful for understanding how dif-
	    ferent types of system behavior affects the values	of  certain  At-
	    tributes.

	    If	the  optional flag '!' is appended, a change of the Raw value is
	    considered critical.  The report will be logged as	LOG_CRIT  and  a
	    warning  email will be sent if '-m' is specified.  An example is '-R
	    5!' to warn when new sectors are reallocated.

     -C ID[+]
	    [ATA only] Report if the current number of pending sectors	is  non-
	    zero.   Here ID is the id number of the Attribute whose raw value is
	    the Current Pending Sector count.  The allowed range of ID is  0  to
	    255  inclusive.   To turn off this reporting, use ID = 0.  If the -C
	    ID option is not given, then it defaults to -C 197 (since  Attribute
	    197  is  generally used to monitor pending sectors).  If the name of
	    this Attribute is changed by a '-v 197,FORMAT,NAME'  directive,  the
	    default is changed to -C 0.

	    If	'+' is specified, a report is only printed if the number of sec-
	    tors has increased between two check cycles.  Some disks do not  re-
	    set  this  attribute when a bad sector is reallocated.  See also '-v
	    197,increasing' below.

	    The warning email counter is reset if the number of pending  sectors
	    dropped  to 0.  This typically happens when all pending sectors have
	    been reallocated or could be read again.

	    A pending sector is a disk sector  (containing  512  bytes	of  your
	    data)  which  the device would like to mark as "bad" and reallocate.
	    Typically this is because your computer tried to read  that  sector,
	    and  the  read  failed because the data on it has been corrupted and
	    has inconsistent Error Checking and Correction (ECC) codes.  This is
	    important to know, because it means that there  is	some  unreadable
	    data  on  the disk.  The problem of figuring out what file this data
	    belongs to is operating system and file system  specific.	You  can
	    typically  force the sector to reallocate by writing to it (transla-
	    tion: make the device substitute a spare good  sector  for	the  bad
	    one) but at the price of losing the 512 bytes of data stored there.

     -U ID[+]
	    [ATA  only] Report if the number of offline uncorrectable sectors is
	    non-zero.  Here ID is the id number of the Attribute whose raw value
	    is the Offline Uncorrectable Sector count.	The allowed range of  ID
	    is	0 to 255 inclusive.  To turn off this reporting, use ID = 0.  If
	    the -U ID option is not given, then it defaults to -U 198 (since At-
	    tribute 198 is generally used to monitor offline uncorrectable  sec-
	    tors).   If  the name of this Attribute is changed by a '-v 198,FOR-
	    MAT,NAME' (except '-v  198,FORMAT,Offline_Scan_UNC_SectCt'),  direc-
	    tive, the default is changed to -U 0.

	    If	'+' is specified, a report is only printed if the number of sec-
	    tors has increased since the last check cycle.  Some  disks  do  not
	    reset this attribute when a bad sector is reallocated.  See also '-v
	    198,increasing' below.

	    The  warning  email counter is reset if the number of offline uncor-
	    rectable sectors dropped to 0.  This typically happens when all  of-
	    fline  uncorrectable  sectors have been reallocated or could be read
	    again.

	    An offline uncorrectable sector is a disk sector which was not read-
	    able during an off-line scan or a self-test.  This is  important  to
	    know,  because  if you have data stored in this disk sector, and you
	    need to read it, the read will fail.  Please see the  previous  '-C'
	    option for more details.

     -W DIFF[,INFO[,CRIT]]
	    Report  if	the current temperature had changed by at least DIFF de-
	    grees since last report, or if new min or  max  temperature  is  de-
	    tected.   Report or Warn if the temperature is greater or equal than
	    one of INFO or CRIT degrees Celsius.  If the limit CRIT is	reached,
	    a  message	with  loglevel	LOG_CRIT  will be logged to syslog and a
	    warning email will be send if '-m' is specified.  If only the  limit
	    INFO is reached, a message with loglevel LOG_INFO will be logged.

	    The  warning email counter is reset if the temperature dropped below
	    INFO or CRIT-5 if INFO is not specified.

	    If this directive is used  in  conjunction	with  state  persistence
	    ('-s'  option),  the  min  and  max temperature values are preserved
	    across boot cycles.  The minimum temperature value	is  not  updated
	    during the first 30 minutes after startup.

	    To	disable  any of the 3 reports, set the corresponding limit to 0.
	    Trailing zero arguments may be omitted.  By default, all temperature
	    reports are disabled ('-W 0').

	    To track temperature changes of at least 2 degrees, use:
	    -W 2
	    To log informal messages on temperatures of  at  least  40	degrees,
	    use:
	    -W 0,40
	    For  warning  messages/mails on temperatures of at least 45 degrees,
	    use:
	    -W 0,0,45
	    To combine all of the above reports, use:
	    -W 2,40,45

	    [ATA] smartd interprets Attribute 194 or 190 as Temperature  Celsius
	    by	default.  This can be changed to Attribute 9 or 220 by the drive
	    database or by the '-v 9,temp' or '-v 220,temp' directive.

	    [NVMe] smartd checks the Composite Temperature value reported by the
	    SMART/HealthInformation log.
	    [NEW EXPERIMENTAL SMARTD 7.5 FIX] The individual Temperature  Sensor
	    values  are  no longer checked because some devices use these to re-
	    port other values like maximum temperature.

     -F TYPE
	    [ATA only] Modifies the behavior of smartd to  compensate  for  some
	    known  and	understood  device  firmware bug.  This directive may be
	    used multiple times.  The valid arguments are:

	    none - Assume that the device firmware obeys the ATA specifications.
	    This is the default, unless the device has presets for '-F'  in  the
	    drive  database.  Using this directive will override any preset val-
	    ues.

	    nologdir - Suppresses read attempts of SMART or  GP  Log  Directory.
	    Support  for  all  standard logs is assumed without an actual check.
	    Some Intel SSDs may freeze if log address 0 is read.

	    samsung - In some Samsung disks  (example:	model  SV4012H	Firmware
	    Version:  RM100-08) some of the two- and four-byte quantities in the
	    SMART data structures are byte-swapped (relative to the ATA specifi-
	    cation).  Enabling this option tells smartd to evaluate these  quan-
	    tities in byte-reversed order.  Some signs that your disk needs this
	    option  are  (1)  no self-test log printed, even though you have run
	    self-tests; (2) very large numbers of ATA errors reported in the ATA
	    error log; (3) strange and impossible values for the ATA  error  log
	    timestamps.

	    samsung2  -  In some Samsung disks the number of ATA errors reported
	    is byte swapped.  Enabling this option tells smartd to evaluate this
	    quantity in byte-reversed order.

	    samsung3 - Some  Samsung  disks  (at  least  SP2514N  with	Firmware
	    VF100-37)  report  a  self-test  still in progress with 0% remaining
	    when the test was already completed.  If this  directive  is  speci-
	    fied,  smartd will not skip the next scheduled self-test (see Direc-
	    tive '-s' above) in this case.

	    xerrorlba - This only affects smartctl.

	    [Please see the smartctl -F command-line option.]

     -v ID,FORMAT[:BYTEORDER][,NAME]
	    [ATA only] Sets a vendor-specific raw value  print	FORMAT,  an  op-
	    tional BYTEORDER and an optional NAME for Attribute ID.  This direc-
	    tive  may  be  used multiple times.  Please see smartctl -v command-
	    line option for further details.

	    The following arguments affect smartd warning output:

	    197,increasing - Raw Attribute number 197  (Current  Pending  Sector
	    Count)  is not reset if uncorrectable sectors are reallocated.  This
	    sets '-C 197+' if no other '-C' directive is specified.

	    198,increasing - Raw Attribute  number  198  (Offline  Uncorrectable
	    Sector Count) is not reset if uncorrectable sectors are reallocated.
	    This sets '-U 198+' if no other '-U' directive is specified.

     -P TYPE
	    [ATA  only]  Specifies  whether smartd should use any preset options
	    that are available for this drive.	The valid arguments to this  Di-
	    rective are:

	    use  -  use  any presets that are available for this drive.  This is
	    the default.

	    ignore - do not use any presets for this drive.

	    show - show the presets listed for this drive in the database.

	    showall - show the presets that are available  for	all  drives  and
	    then exit.

	    [Please see the smartctl -P command-line option.]

     -a     Equivalent to turning on all of the following Directives:
	    '-H -f -t -l error -l selftest -l selfteststs'
	    If none of the above is given, then '-a' is assumed.

	    [ATA  only]  Note:	for historical reasons, '-C 197 -U 198' are also
	    set by default.

     -c OPTION=VALUE
	    Allows one to override smartd command line options for specific  de-
	    vices.  Only the following OPTION is currently supported:

     -c i=N, -c interval=N
	    Sets  the  interval  between  disk checks to N seconds, where N is a
	    decimal integer.  The minimum allowed value is ten.  The default  is
	    the  value	from the '-i N, --interval=N' command line option or its
	    default of 1800 seconds.

     #	    Comment: ignore the remainder of the line.

     \	    Continuation character: if this is the last non-white or non-comment
	    character on a line, then the following line is  a	continuation  of
	    the current one.

     If  you are not sure which Directives to use, I suggest experimenting for a
     few minutes with smartctl to see what SMART functionality your disk(s) sup-
     port(s).  If you do not like voluminous syslog messages, a good  choice  of
     smartd configuration file Directives might be:
     -H -l selftest -l error -f.
     If you want more frequent information, use: -a.

     EXAMPLES OF SHELL SCRIPTS FOR '-M exec'
	    These  are	two  examples of shell scripts that can be used with the
	    '-M exec PATH' Directive described previously.  The paths  to  these
	    scripts and similar executables is the PATH argument to the '-M exec
	    PATH' Directive.

	    Example  1:  This  script is for use with '-m ADDRESS -M exec PATH'.
	    It appends the output of smartctl -a to the  output  of  the  smartd
	    email warning message and sends it to ADDRESS.

	    #! /bin/sh

	    # Save the email message (STDIN) to a file:
	    cat > /root/msg

	    # Append the output of smartctl -a to the message:
	    /usr/local/sbin/smartctl -a -d $SMART_DEVICETYPE \
	      $SMARTD_DEVICE >> /root/msg

	    # Now email the message to the user at address ADD:
	    /usr/bin/mail -s "$SMARTD_SUBJECT" $SMARTD_ADDRESS \
	      < /root/msg

	    Example 2: This script is for use with '-m <nomailer> -M exec PATH'.
	    It	warns all users about a disk problem, waits 30 seconds, and then
	    powers down the machine.

	    #! /bin/sh

	    # Warn all users of a problem
	    wall <<EOF
	    Problem detected with disk: $SMARTD_DEVICESTRING
	    Warning message from smartd is: $SMARTD_MESSAGE
	    Shutting down machine in 30 seconds...
	    EOF

	    # Wait half a minute
	    sleep 30

	    # Power down the machine
	    /sbin/shutdown -hf now

	    Some example scripts are distributed with the smartmontools package,
	    in /usr/local/share/doc/smartmontools/examplescripts/.

	    Please note that these scripts typically run as root, so  any  files
	    that they read/write should not be writable by ordinary users or re-
	    side  in  directories  like /tmp that are writable by ordinary users
	    and may expose your system to symlink attacks.

	    As previously described, if the scripts write to STDOUT  or  STDERR,
	    this  is  interpreted as indicating that there was an internal error
	    within the script, and a snippet of STDOUT/STDERR is logged to  SYS-
	    LOG.  The remainder is flushed.

FILES
     /usr/local/etc/smartd.conf
	    full path of this file.

SEE ALSO
     smartd(8), smartctl(8), mail(1), regex(7).

PACKAGE VERSION
     smartmontools-7.5 2025-04-30 r5714
     $Id: smartd.conf.5.in 5697 2025-04-22 15:02:53Z chrfranke $

smartmontools-7.5		   2025-04-30			  SMARTD.CONF(5)