     The  dd  utility  copies  the standard input to the standard output.  Input
     data is read and written in 512-byte blocks.  If input reads are short, in-
     put from multiple reads are aggregated to form the output block.  When fin-
     ished, dd displays the number of complete	and  partial  input  and  output
     blocks and truncated input records to the standard error output.

     The following operands are available:

     bs=n     Set  both  input and output block size to n bytes, superseding the
	      ibs and obs operands.  If no conversion values other than noerror,
	      notrunc or sync are specified, then each input block is copied  to
	      the  output  as  a  single  block without any aggregation of short
	      blocks.

     cbs=n    Set the conversion record size to n bytes.  The conversion  record
	      size is required by the record oriented conversion values.

     count=n  Copy only n input blocks.

     files=n  Copy  n  input files before terminating.	This operand is only ap-
	      plicable when the input device is a tape.

     ibs=n    Set the input block size to n bytes instead of the default 512.

     if=file  Read input from file instead of the standard input.

     iseek=n  Seek on the input file n blocks.	This is synonymous with skip=n.

     obs=n    Set the output block size to n bytes instead of the default 512.

     of=file  Write output to file instead of the standard output.  Any  regular
	      output  file  is	truncated unless the notrunc conversion value is
	      specified.  If an initial portion of the	output	file  is  seeked
	      past (see the oseek operand), the output file is truncated at that
	      point.

     oseek=n  Seek on the output file n blocks.  This is synonymous with seek=n.

     seek=n   Seek n blocks from the beginning of the output before copying.  On
	      non-tape	devices,  an lseek(2) operation is used.  Otherwise, ex-
	      isting blocks are read and the data discarded.  If the  user  does
	      not  have read permission for the tape, it is positioned using the
	      tape ioctl(2) function calls.  If the seek operation is  past  the
	      end  of  file, space from the current end of file to the specified
	      offset is filled with blocks of NUL bytes.

     skip=n   Skip n blocks from the beginning of the input before copying.   On
	      input which supports seeks, an lseek(2) operation is used.  Other-
	      wise,  input  data  is read and discarded.  For pipes, the correct
	      number of bytes is read.	For all other devices, the correct  num-
	      ber  of blocks is read without distinguishing between a partial or
	      complete block being read.

     conv= value[, value ...]
	      Where value is one of the symbols from the following list.

	      ascii, oldascii
		       The same as the unblock value except that characters  are
		       translated  from  EBCDIC  to ASCII before the records are
		       converted.  (These values imply unblock	if  the  operand
		       cbs  is	also  specified.)  There are two conversion maps
		       for ASCII.  The value ascii specifies the recommended one
		       which is compatible with System V.   The  value	oldascii
		       specifies   the	 one   used   in   historic   AT&T   and
		       pre-4.3BSD-Reno systems.

	      block    Treats the input as a sequence of newline or  end-of-file
		       terminated  variable  length records independent of input
		       and output block boundaries.  Any trailing newline  char-
		       acter  is discarded.  Each input record is converted to a
		       fixed length output record where the length is  specified
		       by  the cbs operand.  Input records shorter than the con-
		       version	record	size  are  padded  with  spaces.   Input
		       records	longer than the conversion record size are trun-
		       cated.  The number of truncated input  records,	if  any,
		       are  reported to the standard error output at the comple-
		       tion of the copy.

	      ebcdic, ibm, oldebcdic, oldibm
		       The same as the block value except  that  characters  are
		       translated  from  ASCII	to  EBCDIC after the records are
		       converted.  (These values imply block if the operand  cbs
		       is  also  specified.)  There are four conversion maps for
		       EBCDIC.	The value ebcdic specifies the	recommended  one
		       which  is  compatible with AT&T System V UNIX.  The value
		       ibm is a slightly different mapping, which is  compatible
		       with  the  AT&T	System	V  UNIX  ibm  value.  The values
		       oldebcdic and oldibm are maps used in historic  AT&T  and
		       pre-4.3BSD-Reno systems.

	      lcase    Transform uppercase characters into lowercase characters.

	      noerror  Do  not stop processing on an input error.  When an input
		       error occurs, a diagnostic message followed by  the  cur-
		       rent input and output block counts will be written to the
		       standard  error output in the same format as the standard
		       completion message.  If the sync conversion is also spec-
		       ified, any missing input data will be replaced  with  NUL
		       bytes  (or  with  spaces  if  a block oriented conversion
		       value was specified) and  processed  as	a  normal  input
		       buffer.	If the sync conversion is not specified, the in-
		       put  block  is  omitted	from the output.  On input files
		       which are not tapes or pipes, the file offset will be po-
		       sitioned past the block in which the error occurred using
		       lseek(2).

	      notrunc  Do not truncate the output file.  This will preserve  any
		       blocks  in  the output file not explicitly written by dd.
		       The notrunc value is not supported for tapes.

	      osync    Pad the final output block to the full output block size.
		       If the input file is not a multiple of the  output  block
		       size  after  conversion, this conversion forces the final
		       output block to be the same size as preceding blocks  for
		       use  on devices that require regularly sized blocks to be
		       written.  This option is incompatible  with  use  of  the
		       bs=n block size specification.

	      sparse   If  one or more output blocks would consist solely of NUL
		       bytes, try to seek the output file by the required  space
		       instead	of filling them with NULs, resulting in a sparse
		       file.

	      swab     Swap every pair of input bytes.	If an input  buffer  has
		       an  odd	number	of  bytes, the last byte will be ignored
		       during swapping.

	      sync     Pad every input block to the input buffer  size.   Spaces
		       are  used  for  pad  bytes if a block oriented conversion
		       value is specified, otherwise NUL bytes are used.

	      ucase    Transform lowercase characters into uppercase characters.

	      unblock  Treats the input as a sequence of  fixed  length  records
		       independent  of	input  and output block boundaries.  The
		       length of the input  records  is  specified  by	the  cbs
		       operand.  Any trailing space characters are discarded and
		       a newline character is appended.

     Where sizes are specified, a decimal, octal, or hexadecimal number of bytes
     is  expected.   If  the  number ends with a ``b'', ``k'', ``m'', ``g'',  or
     ``w'', the number is multiplied by 512, 1024 (1K), 1048576 (1M), 1073741824
     (1G) or the number of bytes in an integer, respectively.  Two or more  num-
     bers may be separated by an ``x'' to indicate a product.

     When  finished,  dd  displays  the number of complete and partial input and
     output blocks, truncated input records and odd-length byte-swapping  blocks
     to the standard error output.  A partial input block is one where less than
     the  input  block	size was read.	A partial output block is one where less
     than the output block size was written.  Partial output blocks to tape  de-
     vices  are  considered fatal errors.  Otherwise, the rest of the block will
     be written.  Partial output blocks to  character  devices	will  produce  a
     warning  message.	 A  truncated input block is one where a variable length
     record oriented conversion value was specified and the input line	was  too
     long to fit in the conversion record or was not newline terminated.

     Normally,	data  resulting  from input or conversion or both are aggregated
     into output blocks of the specified  size.   After  the  end  of  input  is
     reached,  any  remaining output is written as a block.  This means that the
     final output block may be shorter than the output block size.

     If dd receives a SIGINFO (see the ``status'' argument for stty(1))  signal,
     the  current  input and output block counts will be written to the standard
     error output in the same format as the standard completion message.  If  dd
     receives a SIGINT signal, the current input and output block counts will be
     written  to  the  standard  error output in the same format as the standard
     completion message and dd will exit.

DIAGNOSTICS
     The dd utility exits 0 on success, and >0 if an error occurs.

SEE ALSO
     cp(1), mt(1), tr(1)

STANDARDS
     The dd utility is expected  to  be  a  superset  of  the  IEEE  Std  1003.2
     ("POSIX.2")  standard.   The  files  operand  and	the  ascii, ebcdic, ibm,
     oldascii, oldebcdic and oldibm values are extensions to the POSIX standard.

FreeBSD 4.5			January 13, 1994			   DD(1)

home | help