home | help
PCICONF(8)		     System Manager's Manual		      PCICONF(8)

NAME
     pciconf -- diagnostic utility for the PCI bus

SYNOPSIS
     pciconf -l [-v]
     pciconf -a selector
     pciconf -r selector [-b | -h] reg[:reg2]
     pciconf -w selector [-b | -h] reg value

DESCRIPTION
     The  pciconf command provides a command line interface to the functionality
     provided by /dev/pci's ioctl(2) interface.  With the -l  option,  it  lists
     all devices found by the boot probe in the following format:

     foo0@pci0:4:0: class=0x010000 card=0x00000000 chip=0x000f1000 rev=0x01 hdr=0x00
     bar0@pci0:5:0: class=0x000100 card=0x00000000 chip=0x88c15333 rev=0x00 hdr=0x00
     none0@pci0:6:0: class=0x020000 card=0x00000000 chip=0x802910ec rev=0x00 hdr=0x00

     If  the  -v option is supplied, pciconf will attempt to load the vendor/de-
     vice information database, and print vendor,  device,  class  and	subclass
     identification strings for each device.

     The  first  column  gives	the  device name, unit number, and selector.  If
     there is no device configured in the kernel for the PCI device in question,
     the device name will be "none".   Unit  numbers  for  unconfigured  devices
     start  at zero and are incremented for each unconfigured device that is en-
     countered.  The selector is in a form which may directly be  used	for  the
     other  forms of the command.  The second column is the class code, with the
     class byte printed as two hex digits, followed by the sub-class and the in-
     terface bytes.  The third column gives the contents of the subvendorid reg-
     ister, introduced in revision 2.1 of the PCI standard.  It is  0  for  most
     current  (2.0)  PCI  cards, but is supposed to be loaded with a unique card
     identification code in newly developed PCI cards.	The  field  consists  of
     the  card	ID in the upper half and the card vendor ID in the lower half of
     the value.

     The fourth column contains the chip device ID, which  identifies  the  chip
     this card is based on.  It consists of two fields, identifying the chip and
     its  vendor,  as  above.  The fifth column prints the chip's revision.  The
     sixth column describes the header type.  Currently  assigned  header  types
     are  0  for  all  devices	except PCI to PCI bridges, and 1 for such bridge
     chips.  If the most significant bit of the header type register is set  for
     function  0  of a PCI device, it is a multi-function device, which contains
     several (similar or independent) functions on one chip.

     The -l option is the only one available to non-root users.  All other invo-
     cations of pciconf require a selector of the form pcibus:device (optionally
     followed by :function).  A final colon may be appended and will be ignored;
     this is so that the first column in the output of pciconf -l  can	be  used
     without modification.  All numbers are base 10.

     With  the	-a flag, pciconf determines whether any driver has been assigned
     to the device identified by selector.  An exit  status  of  zero  indicates
     that the device has a driver; non-zero indicates that it does not.

     The  -r  option  reads a configuration space register at byte offset reg of
     device selector and prints out its value in hexadecimal.  The optional sec-
     ond reg2 specifies a range to read.  The -w option writes the value into  a
     configuration  space  register  at byte offset reg of device selector.  For
     both operations, the flags -b and -h select the width of the operation;  -b
     indicates	a  byte operation, and -h indicates a halfword (two-byte) opera-
     tion.  The default is to read or write a longword (four bytes).

ENVIRONMENT
     The  PCI  vendor/device  information  database  is   normally   read   from
     /usr/share/misc/pci_vendors.   This  path	can be overridden by setting the
     environment variable PCICONF_VENDOR_DATABASE.

SEE ALSO
     ioctl(2), kldload(8)

HISTORY
     The pciconf command appeared first in FreeBSD 2.2.  The -a option was added
     for PCI KLD support in FreeBSD 3.0.

AUTHORS
     The pciconf facility was written by Stefan Esser and Garrett Wollman.

BUGS
     The -b and -h options are implemented in pciconf, but not in the underlying
     ioctl(2).

     It might be useful to give non-root users access to the -a and -r	options.
     But  only root will be able to execute a kldload to provide the device with
     a driver KLD, and reading of configuration  space	registers  may	cause  a
     failure in badly designed PCI chips.

FreeBSD 4.5			February 7, 1997		      PCICONF(8)

home | help