home | help
SCONFIG(8)		     System Manager's Manual		      SCONFIG(8)

NAME
     sconfig -- channel configuration utility for Cronyx adapters

SYNOPSIS
     sconfig [-aimsxeftuc] [device name] [data rate options]
	     [protocol options ...] [interface options ...]

DESCRIPTION
     The  sconfig  utility  is	used  for configuring the channel options of the
     Cronyx adapters. In asynchronous mode all the parameters should be  set  by
     standard  stty(1) utility, with sconfig you could set only few of them (see
     below).

     Some of the options could be set only on free channels, that is the  corre-
     sponding  network	interface  in down state in the synchronous mode, and in
     the asynchronous mode the asynchronous terminal device /dev/tty* closed.

     Other channel options could be changed "on the fly".  Generally, the  chan-
     nel  options  are	set  up during the operating system startup, for example
     from the /etc/rc file.

     Note, that not all options have a sense for every particular case,  and  an
     attempt to set some of them can hang up the channel or the whole adapter.

   Information options
     You  can specify only one of these options. If information option is speci-
     fied, sconfig will show corresponding information and will ignore all other
     options, except device name. See also description of the device name.

     <none>	 This will show settings of the channel.

     -a 	 Print all settings of the channel.

     -i 	 Print interface settings, equal to the  output  of  ifconfig(1)
		 command.

     -m 	 Print	modem  signal status. The description of all signals can
		 be found in any document related to the modems. Only LE  signal
		 should  be  described. If this signal is On, than some what use
		 channel. If it is Off, than channel is free.

     -s 	 Print brief channel statistics. This is general statistics. See
		 also -x , -e , -f , -t and -u options. For the  description  of
		 output, see below.

		 This statistics is very useful if something goes wrong. For ex-
		 ample,  if  you  have no any interrupts, than you use interrupt
		 that is not registered in BIOS for use with ISA bus.

     -x 	 Print full channel statistics. This options allows to see  some
		 more counters, but with less precision than with -s option.

     -e 	 Print	brief E1/G703 statistics. If you select this option, you
		 will get statistics accumulated for period of time equal to  15
		 minutes. For the description of output, see below.

     -f 	 Print	full  E1/G703  statistics. This option shows all E1/G703
		 statistics that shows previous option( -e  ),	but  also  total
		 statistics for whole period of time and statistics for 24 hours
		 (if available). For the description of output, see below.

     -t 	 Print	brief E3/T3/STS-1 statistics. If you select this option,
		 you will get statistics accumulated for period of time equal to
		 15 minutes. For the description of output, see below.

     -u 	 Print	full  E3/T3/STS-1  statistics.	This  option  shows  all
		 E3/T3/STS-1  statistics  that	shows previous option( -t ), but
		 also total statistics for whole period of time  and  statistics
		 for 24 hours (if available). For the description of output, see
		 below.

     -c 	 Cleans all kind of statistics.

   Device selection
     Device is equal to the name of the interface that is used for a name of the
     interface that is sees ifconfig. The channel number depends on the order of
     loading  drivers  by  the system.	Some times people confuse channel number
     and adapter number because of the same spelling. Adapter number appears  in
     kernel context, channel number in configuration context.

     <none>	 You  can  omit device name only if you want to get information.
		 This will cause printing information about all available  chan-
		 nels of Cronyx adapters. In the case you want to make some set-
		 tings you MUST specify device name.

     cx##	 This  is  the	channel  name  for  the  Sigma	family of Cronyx
		 adapters. (ISA bus)

     ct##	 This is the channel name for the Tau family of Cronyx adapters.
		 (ISA bus)

     cp##	 This is the channel name  for	the  Tau-PCI  family  of  Cronyx
		 adapters. (PCI bus)

     ce##	 This  is  the	channel  name for the Tau32-PCI family of Cronyx
		 adapters. (PCI bus)

   Data rate options
     value	 If case of nonzero value it will cause  setting  data	rate  to
		 given	value  and setting the internal clock source of the syn-
		 chronization (in synchronous mode).  Zero value is equal to the
		 extclock. The transmitted data (TXD) are synchronized using the
		 internal on-board timing generator,  the  internally  generated
		 timing  signal  is  driven on the TXCOUT pin, and the signal on
		 the TXCIN pin is ignored. This mode is used for  direct  termi-
		 nal-to-terminal  communication, e.g. for connecting two comput-
		 ers together in a synchronous mode via relatively short  cable.
		 This  method  should  also be used for testing channels with an
		 external loopback connector.

     extclock	 Set the external timing clock source of  synchronous  channels.
		 External  clock  mode	is the most common method for connecting
		 external modem hardware. In this mode the external timing  sig-
		 nal  is  received on TXCIN pin of the connector, and it is used
		 as a synchronization clock for transmitting data (TXD).

   Protocol options
     Note. These option could be set only if channel is free and  they	requires
     specifying of the device name.

     async	 Set  asynchronous  protocol  (or  mode).  In  this  mode Cronyx
		 adapters behave as a usual serial devices and you may work with
		 them using usual serial utilities.  All  asynchronous	settings
		 are  performed via serial configuration utilities. With sconfig
		 you may set only a few of them. See also  stty(1).   (Only  for
		 Sigma family)

     cisco	 Set the Cisco HDLC synchronous protocol.

     fr 	 Set the Frame Relay synchronous protocol (ANSI T1.617 Annex D).

     ppp	 Set  the  PPP synchronous protocol. Parameters to the PPP could
		 be set by the command spppcontrol(1).

     keepalive=on, keepalive=off
		 Turns on/off sending keepalive messages. This	option	is  used
		 only  for  synchronous PPP. If this option is on, than PPP will
		 periodically send echo-request messages. If it  would	not  re-
		 ceive	any  echo-reply  messages  for some (definite) period of
		 time it will break connection. It is  used  for  tracking  line
		 state.

     idle	 You are using NETGRAPH. Protocol depends on connected module.

   Interface options
     Not  all  of  these  options could be set on running channel and not all of
     them are suits to all kind of adapters/channels. In all dual state  options
     off  is  default  value. All this options is not applicable in asynchronous
     mode, except debug option.

     port=rs232, port=v35, port=rs449
		 Set port type for old Sigma models.

     cfg=A, cfg=B, cfg=C
		 Set configuration for the adapter. This  option  could  be  set
		 only  for  Tau/E1 and Tau/G703 and only if all channels are not
		 running.  cfg=A - Two independent E1/G703 channels. This is de-
		 fault setting.  cfg=B (Only for ISA models) - For Tau/G703 this
		 mean one G703 channel and  one  digital  channel.   For  Tau/E1
		 first	physical  channel divides on to subchannels. One of them
		 goes to the first logical channel and another one goes  to  the
		 second  physical  channel.  Second (logical) channel is digital
		 channel.  cfg=C - This configuration is used only for	E1  mod-
		 els. In this case first physical channel consists of three data
		 flows.  Two  of them go to two (logical) channels. The last one
		 goes to the second physical channel. On new models  (Tau32-PCI,
		 Tau-PCI/2E1  and  Tau-PCI/4E1)  this configuration means single
		 source of synchronization and passing all unused (in both chan-
		 nels) timeslots from one channel to other. For the detailed de-
		 scription of the configuration see your  documentation  to  the
		 adapter. This option could not be set on running channel.

     loop=on, loop=off
		 Turn on/off internal loopback. This mode is useful for testing.
		 Switch on this option and try to send something. If you have no
		 any  interrupt,  than, probably, you forgot to switch using IRQ
		 for PCI to ISA bus. Check your BIOS settings.

     rloop=on, rloop=off (Only for Tau32-PCI and Tau-PCI/E3)
		 Turn on/off remote loopback. This mode is also useful for test-
		 ing.

     dpll=on, dpll=off
		 Turn on/off digital phase locked loop	mode  (DPLL).  When  en-
		 abled, the receiver timing clock signal is derived from the re-
		 ceived data. Must be used with NRZI encoding, to avoid the syn-
		 chronization loss.

     nrzi=on, nrzi=off
		 Turn  on/off  nrzi encoding. In off state nrz encoding is used.
		 NRZ - the zero bit is transmitted by the zero signal level, the
		 one bit - by the positive signal level. NRZI - the  bit  number
		 zero  is transmitted by the change of the signal level, the one
		 bit - by the constant	signal	level.	Commonly  is  used  with
		 dpll=on option.

     invclk=on, invclk=off
		 Invert  the  both  transmit  and receive clock signals (Tau and
		 Tau-PCI only).

     invrclk=on, invrclk=off
		 Invert the receive clock signals (Tau-PCI only).

     invtclk=on, invtclk=off
		 Invert the transmit clock signals (Tau-PCI only).

     higain=on, higain=off
		 Turn on/off increasing the E1 receiver non  linear  sensitivity
		 to  -30  dB  (E1  only). In of state the sensitivity is -12 dB.
		 This allows increasing line distance.

     cablen=on, cablen=off (Only for Tau-PCI/T3 and Tau-PCI/STS-1)
		 Turn on/off adjusting transmit signal for long cable T3/STS-1.

     monitor=on, monitor=off
		 Turn on/off increasing the E1 receiver lines sensitivity to -30
		 dB (Tau32-PCI, Tau-PCI/2E1 and Tau-PCI/4E1 only). This could be
		 used for interception purposes.

     phony=on, phony=off
		 Turn on/off the so-called phony mode (Tau32-PCI and Tau-PCI  E1
		 family  only).  This mode allows receiving raw CEPT frames from
		 E1 line. Raw frames could be accessed,  for  example,	via  raw
		 protocol.  Packets  would come at rate of 500 frames per second
		 with length 16xN (for Tau-PCI/E1 model), where N is the  number
		 of timeslots. For Tau-PCI/2E1 and Tau-PCI/4E1 N should be equal
		 to 32 independently from number of used timeslots.

     unfram=on, unfram=off
		 Turn  on/off  unframed  mode  (Tau32-PCI,  Tau-PCI/2E1 and Tau-
		 PCI/4E1 only).  unfram=on switches channel  to  unframed  G.703
		 mode.	unfram=off switches channel to framed E1 (G.704 mode).

     scrambler=on, scrambler=off
		 Turn  on/off  the  scrambling	of  G.703  data (Tau32-PCI, Tau-
		 PCI/G.703 and Tau-PCI/2E1, Tau-PCI/4E1 in unframed mode only).

     use16=on, use16=off
		 Turn on/off the usage of 16-th timeslot for  data  transmission
		 (Tau32-PCI  and Tau-PCI E1 family only).  Normally 16-th times-
		 lot is used for signaling information (multiframing CAS).

     crc4=on, crc4=off
		 Turn on/off CRC4 superframe mode (E1 only).

     syn=int, syn=rcv, syn=rcv0, syn=rcv1, syn=rcv2, sync=rcv3
		 int - use an internal	clock  generator  for  G703  transmitter
		 (clock  master).  rcv - use the G703 receiver data clock as the
		 transmit clock (clock slave).	rcv0, rcv1, rcv2, rcv3 - use the
		 G703 receiver clock of the other channel (E1 models only).

     dir=<number>
		 Binds logical channel to the physical channel (Tau32-PCI,  Tau-
		 PCI/2E1  and Tau-PCI/4E1 only). Using this parameter you could,
		 for example, split E1 physical channel into several channels.

     ts=interval
		 Set up the list of timeslots to use by the channel  (E1  only).
		 The  timeslots  are numbered from 1 to 31, and are separated by
		 comma	or  minus  sign,  giving  an  interval.   For	example:
		 "ts=1-3,5,17".

     pass=interval
		 Set  up  the list of timeslots, translated to the E1 subchannel
		 in cfg=B and cfg=C configurations (Tau/E1 only).

     debug=0, debug=1, debug=2
		 Turn on/off debug messages.  0 - turn off debug messages.  1  -
		 turn on debug messages, equal to the debug option to the ifcon-
		 fig(8)  utility.   2 - high intensive debug message, developers
		 only.

EXAMPLES
     Set up the channel 1 for use with the HDSL modem or any  other  synchronous
     leased-line modem, and PPP/HDLC protocol (for Sigma):

	   sconfig cx1 ppp extclock
	   ifconfig cx1 158.250.244.2 158.250.244.1 up

     Set  up  the  channel  0  of Tau/E1 for use with the Cisco protocol over E1
     link, with the single virtual connection.	The DLCI number is detected  au-
     tomatically.  Use timeslots 1-10:

	   sconfig ct0 cisco ts=1-10
	   ifconfig ct0 158.250.244.2 158.250.244.1 up

     Set up the channel 0 for the synchronous null-modem link to the nearby com-
     puter,  internal  clock  source,  256000 bits/sec, protocol Cisco/HDLC (for
     Tau):

	   sconfig ct0 cisco 256000
	   ifconfig ct0 200.1.1.1 200.1.1.2 up

     Set up the channel 1 for the leased line link  using  data-only  null-modem
     cable (or modems like Zelax+ M115). Synchronous DPLL mode, 128000 bits/sec,
     protocol PPP/HDLC, NRZI encoding (for Sigma):

	   sconfig cx1 ppp 128000 nrzi=on dpll=on
	   ifconfig cx1 158.250.244.2 158.250.244.1 up

DIAGNOSTICS
     This  section  contains  description of abbreviations used by sconfig while
     displaying various statistics. For description of	options  connected  with
     statistics see above.

   Statistics
     When  running,  the driver gathers the statistics about the channels, which
     could be accessed via sconfig utility or by ioctl(2) call SERIAL_GETSTAT.

     Rintr	 The total number of receive interrupts.

     Tintr	 The total number of transmit interrupts.

     Mintr	 The total number of modem interrupts.

     Ibytes	 The total bytes received.

     Ipkts	 The total packets received (for HDLC mode).

     Ierrs	 The number of receive errors.

     Obytes	 The total bytes transmitted.

     Opkts	 The total packets transmitted (for HDLC mode).

     Oerrs The number of transmit errors.

   E1/G.703 Statistics
     For E1 and G.703 channels the SNMP-compatible statistics data are	gathered
     (see  RFC	1406).	It  could be accessed via sconfig utility or by ioctl(2)
     call SERIAL_GETESTAT.

     Unav (uas)  Unavailable seconds - receiving all ones, or loss  of	carrier,
		 or loss of signal.

     Degr (dm)	 Degraded  minutes  -  having  error  rate  more than 10e-6, not
		 counting unavailable and severely errored seconds.

     Bpv (bpv)	 HDB3 bipolar violation errors.

     Fsyn (fse)  Frame synchronization errors (E1 only).

     CRC (crce)  CRC4 errors (E1).

     RCRC (rcrce)
		 Remote CRC4 errors: E-bit counter (E1).

     Err (es)	 Errored seconds - any framing errors, or out of frame sync,  or
		 any slip events.

     Lerr (les)  Line errored seconds - any BPV.

     Sev (ses)	 Severely  errored seconds - 832 or more framing errors, or 2048
		 or more bipolar violations.

     Bur (bes)	 Bursty errored seconds - more than 1 framing error, but not se-
		 verely errored.

     Oof (oofs)  Severely errored framing seconds - out of frame sync.

     Slp (css)	 Controlled slip second -- any slip buffer  overflow  or  under-
		 flow.

   E1/G.703 Status
     sconfig  utility  also prints the E1/G.703 channel status. The status could
     have the following values (nonexclusive):

     Ok 	 The channel is in valid state, synchronized.

     LOS	 Loss of sync.

     AIS	 Receiving unframed all ones (E1 only).

     LOF	 Loss of framing (E1 only).

     LOMF	 Loss of multiframing (E1 only).

     FARLOF	 Receiving remote alarm (E1 only).

     AIS16	 Receiving all ones in timeslot 16 (E1 only).

     FARLOMF	 Receiving distant multiframe alarm (E1 only).

     TSTREQ	 Receiving test request code (G.703 only).

     TSTERR	 Test error (G.703 only).

SEE ALSO
     stty(1) ioctl(2) sppp(4) spppconrol(8) ifconfig(8) route(8)

HISTORY
     This utility is a replacement of utilities cxconfig and ctconfig  that  was
     used  in  past  with  FreeBSD  drivers. Those two utilities and the present
     utility are not compatible. And therefore all scripts should be  rewritten.
     More  over, Linux and FreeBSD version of present utility not fully compati-
     ble.

BUGS
     All software produced by Cronyx Engineering is thoroughly	tested.  But  as
     created by the man it can contain some `BUGS'.  If you have caught one, try
     to localize it and send a letter with description of this bug and all oper-
     ation that you have done. We will try to reproduce an error and fix it.

CONTACT
     E-mail: info@cronyx.ru

     http://www.cronyx.ru

FreeBSD 			November 21, 2003		      SCONFIG(8)