home | help
GGATEL(8)		     System Manager's Manual		       GGATEL(8)

NAME
     ggatel -- GEOM Gate local control utility

SYNOPSIS
     ggatel create [-v] [-o ro | wo | rw] [-q queue_size] [-s sectorsize]
	    [-t timeout] [-u unit] path
     ggatel attach [-v] [-o ro | wo | rw] -u unit path
     ggatel destroy [-f] -u unit
     ggatel list [-v] [-u unit]

DESCRIPTION
     The  ggatel utility is a local GEOM Gate class consumer.  It can be used as
     a replacement for md(4) devices or as a "GEOMificator" for  non  GEOM-aware
     devices,  but  it was mainly created as an example on how to use and how to
     communicate with the GEOM Gate kernel module.

     Available commands:

     create   Create a ggate provider related to the given regular file  or  de-
	      vice.

     attach   Attach a worker process to an existing ggate provider.

     destroy  Destroy the given ggate provider.

     list     List ggate providers.

     Available options:

     -f 	      Forcibly	destroy  ggate provider (cancels all pending re-
		      quests).

     -o ro | wo | rw  Specify permission to use when opening the file or device:
		      read-only (ro), write-only (wo), or read-write (rw).   De-
		      fault is rw.

     -q queue_size    Number  of  pending I/O requests that can be queued before
		      they will start to be canceled.  Default is 1024.

     -s sectorsize    Sector size for ggate provider.  If not specified,  it  is
		      taken from device, or set to 512 bytes for files.

     -t timeout       Number  of  seconds  to wait before an I/O request will be
		      canceled.  0 means no timeout.  Default is 30.

     -u unit	      Unit number to use.

     -v 	      Do not fork, run in foreground and  print  debug	informa-
		      tions on standard output.

     path	      Path to a regular file or device.

EXAMPLES
     "GEOMify" the "fd0" device and use gbde(8) to encrypt data on a floppy.

	   ggatel create -u 5 /dev/fd0
	   gbde init /dev/ggate5
	   gbde attach ggate5
	   newfs /dev/ggate5.bde
	   mount /dev/ggate5.bde /secret
	   cp /private/foo /secret/
	   umount /secret
	   gbde detach ggate5
	   ggatel destroy -u 5

DIAGNOSTICS
     Exit  status  is  0  on success, or 1 if the command fails.  To get details
     about the failure, ggatel should be called with the -v option.

SEE ALSO
     geom(4), gbde(8), ggatec(8), ggated(8), mount(8), newfs(8)

AUTHORS
     The ggatel utility as well as this manual page was written by  Pawel  Jakub
     Dawidek <pjd@FreeBSD.org>.

FreeBSD 5.3			 April 26, 2004 		       GGATEL(8)

home | help