home | help
CAMCONTROL(8)		     System Manager's Manual		   CAMCONTROL(8)

NAME
     camcontrol -- CAM control program

SYNOPSIS
     camcontrol <command> [device id] [generic args] [command args]
     camcontrol devlist [-v]
     camcontrol periphlist [device id] [-n dev_name] [-u unit_number]
     camcontrol tur [device id] [generic args]
     camcontrol inquiry [device id] [generic args] [-D] [-S] [-R]
     camcontrol reportluns [device id] [generic args] [-c] [-l] [-r reporttype]
     camcontrol readcap [device id] [generic args] [-b] [-h] [-H] [-N] [-q] [-s]
     camcontrol start [device id] [generic args]
     camcontrol stop [device id] [generic args]
     camcontrol load [device id] [generic args]
     camcontrol eject [device id] [generic args]
     camcontrol rescan <all | bus[:target:lun]>
     camcontrol reset <all | bus[:target:lun]>
     camcontrol defects [device id] [generic args] <-f format> [-P] [-G]
     camcontrol modepage [device id] [generic args] <-m page | -l> [-P pgctl]
		[-b | -e] [-d]
     camcontrol cmd [device id] [generic args] <-c cmd [args]> [-i len fmt]
		[-o len fmt [args]]
     camcontrol debug [-I] [-P] [-T] [-S] [-X] [-c] <all|off|bus[:target[:lun]]>
     camcontrol tags [device id] [generic args] [-N tags] [-q] [-v]
     camcontrol negotiate [device id] [generic args] [-c] [-D enable|disable]
		[-O offset] [-q] [-R syncrate] [-T enable|disable] [-U]
		[-W bus_width] [-v]
     camcontrol format [device id] [generic args] [-q] [-r] [-w] [-y]
     camcontrol help

DESCRIPTION
     The camcontrol utility is designed to provide a way for users to access and
     control the FreeBSD CAM subsystem.

     The  camcontrol  utility  can cause a loss of data and/or system crashes if
     used improperly.  Even expert users are encouraged to exercise caution when
     using this command.  Novice users should stay away from this utility.

     The camcontrol utility has a number of primary  functions,  many  of  which
     support an optional device identifier.  A device identifier can take one of
     three forms:

     deviceUNIT      Specify  a  device  name  and unit number combination, like
		     "da5" or "cd3".  Note  that  character  device  node  names
		     (e.g. /dev/da0) are not allowed here.

     bus:target      Specify  a bus number and target id.  The bus number can be
		     determined from the output of  "camcontrol  devlist".   The
		     lun defaults to 0.

     bus:target:lun  Specify the bus, target and lun for a device.  (e.g. 1:2:0)

     The  device identifier, if it is specified, must come immediately after the
     function name, and before any generic or function-specific arguments.  Note
     that the -n and -u arguments described below will override any device  name
     or  unit  number  specified  beforehand.	The -n and -u arguments will not
     override a specified bus:target or bus:target:lun, however.

     Most of the camcontrol primary functions support these generic arguments:

     -C count	     SCSI command retry count.	In order for this to work, error
		     recovery (-E) must be turned on.

     -E 	     Instruct the kernel to perform generic SCSI error	recovery
		     for  the  given  command.	 This is needed in order for the
		     retry count (-C) to be honored.  Other than  retrying  com-
		     mands,  the  generic error recovery in the code will gener-
		     ally attempt to spin up drives that are not  spinning.   It
		     may  take some other actions, depending upon the sense code
		     returned from the command.

     -n dev_name     Specify the device type to operate on, e.g. "da", "cd".

     -t timeout      SCSI command timeout in seconds.  This  overrides	the  de-
		     fault timeout for any given command.

     -u unit_number  Specify the device unit number, e.g. "1", "5".

     -v 	     Be  verbose,  print  out  sense information for failed SCSI
		     commands.

     Primary command functions:

     devlist	 List all physical devices (logical units) attached to	the  CAM
		 subsystem.  This also includes a list of peripheral drivers at-
		 tached  to each device.  With the -v argument, SCSI bus number,
		 adapter name and unit numbers are printed as well.

     periphlist  List all peripheral drivers attached to a given physical device
		 (logical unit).

     tur	 Send the SCSI test unit ready (0x00) command to the  given  de-
		 vice.	The camcontrol utility will report whether the device is
		 ready or not.

     inquiry	 Send  a  SCSI	inquiry command (0x12) to a device.  By default,
		 camcontrol will print out the standard inquiry data, device se-
		 rial number, and transfer rate information.  The user can spec-
		 ify that only certain types of inquiry data be printed:

		 -D    Get the standard inquiry data.

		 -S    Print out the serial number.  If this flag  is  the  only
		       one specified, camcontrol will not print out "Serial Num-
		       ber"  before the value returned by the drive.  This is to
		       aid in script writing.

		 -R    Print out transfer rate information.

     reportluns  Send the SCSI REPORT LUNS (0xA0) command to the  given  device.
		 By default, camcontrol will print out the list of logical units
		 (LUNs)  supported  by the target device.  There are a couple of
		 options to modify the output:

		 -c		 Just print out a count of LUNs, not the  actual
				 LUN numbers.

		 -l		 Just  print  out  the LUNs, and don't print out
				 the count.

		 -r reporttype	 Specify the type of report to request from  the
				 target:

				 default    Return  the default report.  This is
					    the camcontrol default.   Most  tar-
					    gets  will	support  this  report if
					    they support the  REPORT  LUNS  com-
					    mand.

				 wellknown  Return only well known LUNs.

				 all	    Return all available LUNs.

		 camcontrol  will  try	to print out LUN numbers in a reasonable
		 format.  It can understand the peripheral, flat,  LUN	and  ex-
		 tended LUN formats.

     readcap	 Send  the  SCSI  READ	CAPACITY command to the given device and
		 display the results.  If the device is  larger  than  2TB,  the
		 SCSI  READ  CAPACITY (16) service action will be sent to obtain
		 the full size of the device.  By default, camcontrol will print
		 out the last logical block of the device, and the blocksize  of
		 the device in bytes.  To modify the output format, use the fol-
		 lowing options:

		 -b	Just  print out the blocksize, not the last block or de-
			vice size.  This cannot be used with -N or -s.

		 -h	Print out the device size in human readable (base 2,  1K
			==  1024)  format.   This  implies -N and cannot be used
			with -q or -b.

		 -H	Print out the device size in human readable (base 10, 1K
			== 1000) format.

		 -N	Print out the number of blocks in the device instead  of
			the last logical block.

		 -q	Quiet,	print out the numbers only (separated by a comma
			if -b or -s are not specified).

		 -s	Print out the last logical block or the size of the  de-
			vice only, and omit the blocksize.

     start	 Send  the  SCSI Start/Stop Unit (0x1B) command to the given de-
		 vice with the start bit set.

     stop	 Send the SCSI Start/Stop Unit (0x1B) command to the  given  de-
		 vice with the start bit cleared.

     load	 Send  the  SCSI Start/Stop Unit (0x1B) command to the given de-
		 vice with the start bit set and the load/eject bit set.

     eject	 Send the SCSI Start/Stop Unit (0x1B) command to the  given  de-
		 vice with the start bit cleared and the load/eject bit set.

     rescan	 Tell  the kernel to scan all busses in the system (with the all
		 argument), the  given	bus  (XPT_SCAN_BUS),  or  bus:target:lun
		 (XPT_SCAN_LUN)  for new devices or devices that have gone away.
		 The user may specify a scan of all busses, a single bus,  or  a
		 lun.  Scanning all luns on a target is not supported.

     reset	 Tell the kernel to reset all busses in the system (with the all
		 argument)  or	the  given bus (XPT_RESET_BUS) by issuing a SCSI
		 bus reset for that bus, or to reset  the  given  bus:target:lun
		 (XPT_RESET_DEV),  typically  by issuing a BUS DEVICE RESET mes-
		 sage after connecting to that device.	Note that this can  have
		 a destructive impact on the system.

     defects	 Send the SCSI READ DEFECT DATA (10) command (0x37) to the given
		 device,  and  print out any combination of: the total number of
		 defects, the primary defect list (PLIST), and the grown  defect
		 list (GLIST).

		 -f format    The  three format options are: block, to print out
			      the list as logical blocks, bfi, to print out  the
			      list  in	bytes  from  index  format, and phys, to
			      print out the list in physical sector format.  The
			      format argument is required.  Most drives  support
			      the  physical  sector format.  Some drives support
			      the logical block format.  Many drives, if they do
			      not support the requested format, return the  data
			      in  an alternate format, along with sense informa-
			      tion indicating that the requested data format  is
			      not supported.  The camcontrol utility attempts to
			      detect  this,  and  print  out whatever format the
			      drive returns.  If the drive uses  a  non-standard
			      sense  code to report that it does not support the
			      requested format, camcontrol will probably see the
			      error as a failure to complete the request.

		 -G	      Print out the grown defect list.	This is  a  list
			      of  bad  blocks  that have been remapped since the
			      disk left the factory.

		 -P	      Print out the primary defect list.

		 If neither -P nor -G is specified, camcontrol	will  print  out
		 the  number of defects given in the READ DEFECT DATA header re-
		 turned from the drive.

     modepage	 Allows the user to display and  optionally  edit  a  SCSI  mode
		 page.	   The	  mode	  page	  formats    are    located   in
		 /usr/share/misc/scsi_modes.  This can be overridden by specify-
		 ing a different file in the  SCSI_MODES  environment  variable.
		 The modepage command takes several arguments:

		 -d	       Disable block descriptors for mode sense.

		 -b	       Displays mode page data in binary format.

		 -e	       This  flag  allows the user to edit values in the
			       mode page.  The user may either	edit  mode  page
			       values  with  the  text	editor pointed to by his
			       EDITOR environment variable, or supply mode  page
			       values  via standard input, using the same format
			       that camcontrol uses to display mode page values.
			       The editor will be invoked if camcontrol  detects
			       that standard input is terminal.

		 -l	       Lists all available mode pages.

		 -m mode_page  This  specifies	the  number of the mode page the
			       user would like to view and/or edit.  This  argu-
			       ment is mandatory unless -l is specified.

		 -P pgctl      This  allows the user to specify the page control
			       field.  Possible values are:
			       0    Current values
			       1    Changeable values
			       2    Default values
			       3    Saved values

     cmd	 Allows the user to send an arbitrary SCSI CDB	to  any  device.
		 The  cmd  function requires the -c argument to specify the CDB.
		 Other arguments are optional, depending on  the  command  type.
		 The  command  and  data  specification  syntax is documented in
		 cam_cdbparse(3).  NOTE: If the CDB specified causes data to  be
		 transfered  to  or  from  the SCSI device in question, you MUST
		 specify either -i or -o.

		 -c cmd [args]	    This specifies the SCSI CDB.  CDBs may be 6,
				    10, 12 or 16 bytes.

		 -i len fmt	    This specifies the amount of data  to  read,
				    and how it should be displayed.  If the for-
				    mat  is  `-', len bytes of data will be read
				    from the device and written to standard out-
				    put.

		 -o len fmt [args]  This specifies the	amount	of  data  to  be
				    written to a device, and the data that is to
				    be written.  If the format is `-', len bytes
				    of data will be read from standard input and
				    written to the device.

     debug	 Turn on CAM debugging printfs in the kernel.  This requires op-
		 tions	CAMDEBUG  in your kernel config file.  WARNING: enabling
		 debugging printfs currently causes an EXTREME number of  kernel
		 printfs.   You  may  have  difficulty turning off the debugging
		 printfs once they start, since the kernel will be busy printing
		 messages and unable to service  other	requests  quickly.   The
		 debug function takes a number of arguments:

		 -I		     Enable CAM_DEBUG_INFO printfs.

		 -P		     Enable CAM_DEBUG_PERIPH printfs.

		 -T		     Enable CAM_DEBUG_TRACE printfs.

		 -S		     Enable CAM_DEBUG_SUBTRACE printfs.

		 -X		     Enable CAM_DEBUG_XPT printfs.

		 -c		     Enable  CAM_DEBUG_CDB  printfs.   This will
				     cause the kernel to print out the SCSI CDBs
				     sent to the specified device(s).

		 all		     Enable debugging for all devices.

		 off		     Turn off debugging for all devices

		 bus[:target[:lun]]  Turn on debugging for the given bus, target
				     or lun.  If the lun or target and	lun  are
				     not specified, they are wildcarded.  (i.e.,
				     just  specifying  a  bus turns on debugging
				     printfs for all devices on that bus.)

     tags	 Show or set the number of  "tagged  openings"	or  simultaneous
		 transactions  we  attempt  to queue to a particular device.  By
		 default, the tags command, with no  command-specific  arguments
		 (i.e.,  only  generic	arguments) prints out the "soft" maximum
		 number of transactions that can be  queued  to  the  device  in
		 question.   For  more detailed information, use the -v argument
		 described below.

		 -N tags  Set the number of tags for  the  given  device.   This
			  must	be between the minimum and maximum number set in
			  the kernel quirk table.  The default for most  devices
			  that	support  tagged queueing is a minimum of 2 and a
			  maximum of 255.  The minimum and maximum values for  a
			  given device may be determined by using the -v switch.
			  The  meaning of the -v switch for this camcontrol sub-
			  command is described below.

		 -q	  Be quiet, and do not report the number of tags.   This
			  is generally used when setting the number of tags.

		 -v	  The  verbose	flag  has  special functionality for the
			  tags argument.  It causes camcontrol to print out  the
			  tagged  queueing  related  fields of the XPT_GDEV_TYPE
			  CCB:

			  dev_openings	 This is  the  amount  of  capacity  for
					 transactions queued to a given device.

			  dev_active	 This is the number of transactions cur-
					 rently queued to a device.

			  devq_openings  This  is  the	kernel	queue  space for
					 transactions.	This count usually  mir-
					 rors  dev_openings  except during error
					 recovery  operations  when  the  device
					 queue	is frozen (device is not allowed
					 to receive  commands),  the  number  of
					 dev_openings is reduced, or transaction
					 replay is occurring.

			  devq_queued	 This  is  the	number	of  transactions
					 waiting in the kernel queue for  capac-
					 ity on the device.  This number is usu-
					 ally  zero  unless error recovery is in
					 progress.

			  held		 The held count is the	number	of  CCBs
					 held  by  peripheral  drivers that have
					 either just been completed or are about
					 to be released to the	transport  layer
					 for service by a device.  Held CCBs re-
					 serve capacity on a given device.

			  mintags	 This is the current "hard" minimum num-
					 ber  of transactions that can be queued
					 to a device at once.  The  dev_openings
					 value	above  cannot go below this num-
					 ber.  The default value for mintags  is
					 2,  although  it  may	be set higher or
					 lower for various devices.

			  maxtags	 This is the "hard"  maximum  number  of
					 transactions  that  can  be queued to a
					 device at one time.   The  dev_openings
					 value cannot go above this number.  The
					 default  value  for maxtags is 255, al-
					 though it may be set  higher  or  lower
					 for various devices.

     negotiate	 Show  or negotiate various communication parameters.  Some con-
		 trollers may not support setting or changing some of these val-
		 ues.  For instance, the Adaptec 174x controllers do not support
		 changing a device's sync rate or offset.  The camcontrol  util-
		 ity will not attempt to set the parameter if the controller in-
		 dicates  that	it  does  not support setting the parameter.  To
		 find out what the controller supports, use the  -v  flag.   The
		 meaning  of  the -v flag for the negotiate command is described
		 below.  Also, some controller drivers do  not	support  setting
		 negotiation  parameters, even if the underlying controller sup-
		 ports negotiation changes.  Some controllers, such as	the  Ad-
		 vansys  wide  controllers,  support enabling and disabling syn-
		 chronous negotiation for a device, but do not	support  setting
		 the synchronous negotiation rate.

		 -a		    Attempt  to  make  the  negotiation settings
				    take effect immediately by	sending  a  Test
				    Unit Ready command to the device.

		 -c		    Show  or  set  current negotiation settings.
				    This is the default.

		 -D enable|disable  Enable or disable disconnection.

		 -O offset	    Set the command delay offset.

		 -q		    Be quiet, do not print  anything.	This  is
				    generally  useful when you want to set a pa-
				    rameter, but do not want any status informa-
				    tion.

		 -R syncrate	    Change the synchronization rate  for  a  de-
				    vice.   The  sync  rate  is a floating point
				    value specified in MHz.  So,  for  instance,
				    `20.000' is a legal value, as is `20'.

		 -T enable|disable  Enable  or disable tagged queueing for a de-
				    vice.

		 -U		    Show or set user negotiation settings.   The
				    default  is  to show or set current negotia-
				    tion settings.

		 -v		    The verbose switch has special  meaning  for
				    the   negotiate   subcommand.    It   causes
				    camcontrol to print out the  contents  of  a
				    Path  Inquiry (XPT_PATH_INQ) CCB sent to the
				    controller driver.

		 -W bus_width	    Specify the bus width to  negotiate  with  a
				    device.  The bus width is specified in bits.
				    The only useful values to specify are 8, 16,
				    and  32  bits.   The controller must support
				    the bus width in question in order	for  the
				    setting to take effect.

		 In  general, sync rate and offset settings will not take effect
		 for a device until a command has been sent to the device.   The
		 -a  switch  above  will automatically send a Test Unit Ready to
		 the device so negotiation parameters will take effect.

     format	 Issue the SCSI FORMAT UNIT command to the named device.

		 WARNING! WARNING! WARNING!

		 Low level formatting a disk will destroy ALL data on the  disk.
		 Use extreme caution when issuing this command.  Many users low-
		 level format disks that do not really need to be low-level for-
		 matted.   There are relatively few scenarios that call for low-
		 level formatting a disk.  One reason for low-level formatting a
		 disk is to initialize the disk after changing its physical sec-
		 tor size.  Another reason for low-level formatting a disk is to
		 revive the disk if you are getting  "medium  format  corrupted"
		 errors from the disk in response to read and write requests.

		 Some  disks  take  longer  than others to format.  Users should
		 specify a timeout long enough to allow the format to  complete.
		 The  default  format  timeout	is 3 hours, which should be long
		 enough for most disks.  Some hard disks will complete a  format
		 operation  in	a  very  short period of time (on the order of 5
		 minutes or less).  This is often because the drive does not re-
		 ally support the FORMAT UNIT command --  it  just  accepts  the
		 command, waits a few minutes and then returns it.

		 The `format' subcommand takes several arguments that modify its
		 default  behavior.   The  -q and -y arguments can be useful for
		 scripts.

		 -q	 Be quiet, do not print any status messages.   This  op-
			 tion  will not disable the questions, however.  To dis-
			 able questions, use the -y argument, below.

		 -r	 Run in "report only" mode.  This will report status  on
			 a format that is already running on the drive.

		 -w	 Issue	a  non-immediate  format  command.   By default,
			 camcontrol issues the FORMAT UNIT command with the  im-
			 mediate  bit set.  This tells the device to immediately
			 return the format command, before the format has  actu-
			 ally  completed.   Then,  camcontrol gathers SCSI sense
			 information from the device every second  to  determine
			 how  far  along in the format process it is.  If the -w
			 argument is specified, camcontrol will issue a  non-im-
			 mediate format command, and will be unable to print any
			 information to let the user know what percentage of the
			 disk has been formatted.

		 -y	 Do  not ask any questions.  By default, camcontrol will
			 ask the user if he/she really wants to format the  disk
			 in  question,	and  also  if the default format command
			 timeout is acceptable.  The  user  will  not  be  asked
			 about the timeout if a timeout is specified on the com-
			 mand line.

     help	 Print out verbose usage information.

ENVIRONMENT
     The  SCSI_MODES  variable allows the user to specify an alternate mode page
     format file.

     The EDITOR variable determines which text	editor	camcontrol  starts  when
     editing mode pages.

FILES
     /usr/share/misc/scsi_modes  is the SCSI mode format database.
     /dev/xpt0			 is the transport layer device.
     /dev/pass* 		 are the CAM application passthrough devices.

EXAMPLES
	   camcontrol eject -n cd -u 1 -v

     Eject  the  CD  from  cd1,  and print SCSI sense information if the command
     fails.

	   camcontrol tur da0

     Send the SCSI test unit ready command to da0.  The camcontrol utility  will
     report whether the disk is ready, but will not display sense information if
     the command fails since the -v switch was not specified.

	   camcontrol tur da1 -E -C 4 -t 50 -v

     Send  a  test  unit  ready  command  to da1.  Enable kernel error recovery.
     Specify a retry count of 4, and a timeout	of  50	seconds.   Enable  sense
     printing  (with the -v flag) if the command fails.  Since error recovery is
     turned on, the disk will be spun up if it is not currently  spinning.   The
     camcontrol utility will report whether the disk is ready.

	   camcontrol cmd -n cd -u 1 -v -c "3C 00 00 00 00 00 00 00 0e 00" \
		   -i 0xe "s1 i3 i1 i1 i1 i1 i1 i1 i1 i1 i1 i1"

     Issue a READ BUFFER command (0x3C) to cd1.  Display the buffer size of cd1,
     and  display  the first 10 bytes from the cache on cd1.  Display SCSI sense
     information if the command fails.

	   camcontrol cmd -n cd -u 1 -v -c "3B 00 00 00 00 00 00 00 0e 00" \
		   -o 14 "00 00 00 00 1 2 3 4 5 6 v v v v" 7 8 9 8

     Issue a WRITE BUFFER (0x3B) command to cd1.  Write out 10	bytes  of  data,
     not including the (reserved) 4 byte header.  Print out sense information if
     the  command  fails.   Be	very careful with this command, improper use may
     cause data corruption.

	   camcontrol modepage da3 -m 1 -e -P 3

     Edit mode page 1 (the Read-Write Error Recover page) for da3, and save  the
     settings  on  the drive.  Mode page 1 contains a disk drive's auto read and
     write reallocation settings, among other things.

	   camcontrol rescan all

     Rescan all SCSI busses in the system for devices that have been added,  re-
     moved or changed.

	   camcontrol rescan 0

     Rescan SCSI bus 0 for devices that have been added, removed or changed.

	   camcontrol rescan 0:1:0

     Rescan SCSI bus 0, target 1, lun 0 to see if it has been added, removed, or
     changed.

	   camcontrol tags da5 -N 24

     Set the number of concurrent transactions for da5 to 24.

	   camcontrol negotiate -n da -u 4 -T disable

     Disable tagged queueing for da4.

	   camcontrol negotiate -n da -u 3 -R 20.000 -O 15 -a

     Negotiate	a  sync rate of 20MHz and an offset of 15 with da3.  Then send a
     Test Unit Ready command to make the settings take effect.

SEE ALSO
     cam(3), cam_cdbparse(3), cam(4), pass(4), xpt(4)

HISTORY
     The camcontrol utility first appeared in FreeBSD 3.0.

     The mode page editing code and arbitrary SCSI command code are  based  upon
     code  in  the  old  scsi(8)  utility and scsi(3) library, written by Julian
     Elischer and Peter Dufault.  The scsi(8) program first appeared  in  386BSD
     0.1.2.4, and first appeared in FreeBSD in FreeBSD 2.0.5.

AUTHORS
     Kenneth Merry <ken@FreeBSD.org>

BUGS
     The  code that parses the generic command line arguments does not know that
     some of the subcommands take multiple arguments.  So if, for instance,  you
     tried something like this:

	   camcontrol cmd -n da -u 1 -c "00 00 00 00 00 v" 0x00 -v

     The  sense  information  from  the  test  unit  ready command would not get
     printed out, since the first getopt(3) call in camcontrol bails out when it
     sees the second argument to -c (0x00), above.  Fixing this  behavior  would
     take  some gross code, or changes to the getopt(3) interface.  The best way
     to circumvent this problem is  to	always	make  sure  to	specify  generic
     camcontrol arguments before any command-specific arguments.

FreeBSD 7.0			 August 21, 2006		   CAMCONTROL(8)

home | help