home | help
PCICONF(8)		     System Manager's Manual		      PCICONF(8)

NAME
     pciconf -- diagnostic utility for the PCI bus

SYNOPSIS
     pciconf -l [-bcev]
     pciconf -a selector
     pciconf -r [-b | -h] selector addr[:addr2]
     pciconf -w [-b | -h] selector addr value

DESCRIPTION
     The pciconf utility provides a command line interface to functionality pro-
     vided by the pci(4) ioctl(2) interface.  As such, some of the functions are
     only  available  to  users with write access to /dev/pci, normally only the
     super-user.

     With the -l option, it lists all devices found by the  boot  probe  in  the
     following format:

     foo0@pci0:0:4:0: class=0x010000 card=0x00000000 chip=0x000f1000 rev=0x01 hdr=0x00
     bar0@pci0:0:5:0: class=0x000100 card=0x00000000 chip=0x88c15333 rev=0x00 hdr=0x00
     none0@pci0:0:6:0: class=0x020000 card=0x00000000 chip=0x802910ec rev=0x00 hdr=0x00

     The  first  column  gives	the  device name, unit number, and selector.  If
     there is no device configured in the kernel for the PCI device in question,
     the device name will be "none".   Unit  numbers  for  unconfigured  devices
     start  at zero and are incremented for each unconfigured device that is en-
     countered.  The selector is in a form which may directly be  used	for  the
     other  forms of the command.  The second column is the class code, with the
     class byte printed as two hex digits, followed by the sub-class and the in-
     terface bytes.  The third column gives the contents of the subvendorid reg-
     ister, introduced in revision 2.1 of the PCI standard.  Note that	it  will
     be  0 for older cards.  The field consists of the card ID in the upper half
     and the card vendor ID in the lower half of the value.

     The fourth column contains the chip device ID, which  identifies  the  chip
     this card is based on.  It consists of two fields, identifying the chip and
     its  vendor,  as  above.  The fifth column prints the chip's revision.  The
     sixth column describes the header type.  Currently  assigned  header  types
     include  0  for  most  devices,  1 for PCI to PCI bridges, and 2 for PCI to
     CardBus bridges.  If the most significant bit of the header  type	register
     is set for function 0 of a PCI device, it is a multi-function device, which
     contains several (similar or independent) functions on one chip.

     If  the -b option is supplied, pciconf will list any base address registers
     (BARs) that are assigned resources for each device.  Each BAR will be  enu-
     merated via a line in the following format:

	 bar   [10] = type Memory, range 32, base 0xda060000, size 131072, enabled

     The first value after the "bar" prefix in the square brackets is the offset
     of  the  BAR  in  config space in hexadecimal.  The type of a BAR is one of
     "Memory", "Prefetchable Memory", or "I/O Port".  The  range  indicates  the
     maximum  address the BAR decodes.	The base and size indicate the start and
     length of the BAR's address window, respectively.	Finally, the  last  flag
     indicates if the BAR is enabled or disabled.

     If  the -c option is supplied, pciconf will list any capabilities supported
     by each device.  Each capability is enumerated via a line in the  following
     format:

	 cap 10[40] = PCI-Express 1 root port

     The first value after the "cap" prefix is the capability ID in hexadecimal.
     The  second value in the square brackets is the offset of the capability in
     config space in hexadecimal.  The format of the text after the equals  sign
     is capability-specific.

     Each extended capability is enumerated via a line in a similar format:

     ecap 0002[100] = VC 1 max VC0

     The  first  value	after the "ecap" prefix is the extended capability ID in
     hexadecimal.  The second value in the square brackets is the offset of  the
     extended capability in config space in hexadecimal.  The format of the text
     after the equals sign is capability-specific.

     If  the  -e  option  is supplied, pciconf will list any errors reported for
     this device in standard PCI error registers.  Errors are checked for in the
     PCI status register, the PCI-express device status register,  and	the  Ad-
     vanced Error Reporting status registers.

     If  the  -v option is supplied, pciconf will attempt to load the vendor/de-
     vice information database, and print vendor,  device,  class  and	subclass
     identification strings for each device.

     All  invocations  of  pciconf  except for -l require a selector of the form
     pcidomain:bus:device:function,  pcibus:device:function,  or  pcibus:device.
     In  case of an abridged form, omitted selector components are assumed to be
     0.  An optional leading device name followed by @	and  an  optional  final
     colon  will  be  ignored; this is so that the first column in the output of
     pciconf -l can be used without modification.  All numbers are base 10.

     With the -a flag, pciconf determines whether any driver has  been	assigned
     to  the  device  identified  by selector.	An exit status of zero indicates
     that the device has a driver; non-zero indicates that it does not.

     The -r option reads a configuration space register at byte offset	addr  of
     device selector and prints out its value in hexadecimal.  The optional sec-
     ond  address  addr2  specifies  a	range to read.	The -w option writes the
     value into a configuration space register at byte	offset	addr  of  device
     selector.	For both operations, the flags -b and -h select the width of the
     operation; -b indicates a byte operation, and -h indicates a halfword (two-
     byte) operation.  The default is to read or write a longword (four bytes).

ENVIRONMENT
     The   PCI	 vendor/device	 information  database	is  normally  read  from
     /usr/share/misc/pci_vendors.  This path can be overridden	by  setting  the
     environment variable PCICONF_VENDOR_DATABASE.

SEE ALSO
     ioctl(2), devinfo(8), kldload(8)

HISTORY
     The pciconf utility appeared first in FreeBSD 2.2.  The -a option was added
     for PCI KLD support in FreeBSD 3.0.

AUTHORS
     The pciconf utility was written by Stefan Esser and Garrett Wollman.

BUGS
     The -b and -h options are implemented in pciconf, but not in the underlying
     ioctl(2).

     It  might be useful to give non-root users access to the -a and -r options.
     But only root will be able to execute a kldload to provide the device  with
     a	driver	KLD,  and  reading  of configuration space registers may cause a
     failure in badly designed PCI chips.

FreeBSD 9.1			  June 1, 2012			      PCICONF(8)