Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
dcm2pdf(1)			  OFFIS	DCMTK			    dcm2pdf(1)

NAME
       dcm2pdf - Extract PDF file from DICOM encapsulated PDF

SYNOPSIS
       dcm2pdf [options] dcmfile-in pdffile-out

DESCRIPTION
       The  dcm2pdf utility reads a DICOM file of the Encapsulated PDF Storage
       SOP Class (dcmfile-in), extracts	the embedded PDF document  and	writes
       it  to  an  output  file	 (pdffile-out).	 Optionally  a	command	can be
       executed	after the creation of the PDF file.

PARAMETERS
       dcmfile-in   DICOM input	filename ("-" for stdin)

       pdffile-out  PDF	output filename

OPTIONS
   general options
	 -h   --help
		print this help	text and exit

	      --version
		print version information and exit

	      --arguments
		print expanded command line arguments

	 -q   --quiet
		quiet mode, print no warnings and errors

	 -v   --verbose
		verbose	mode, print processing details

	 -d   --debug
		debug mode, print debug	information

	 -ll  --log-level  [l]evel: string constant
		(fatal,	error, warn, info, debug, trace)
		use level l for	the logger

	 -lc  --log-config  [f]ilename:	string
		use config file	f for the logger

   input options
       input file format:

	 +f   --read-file
		read file format or data set (default)

	 +fo  --read-file-only
		read file format only

	 -f   --read-dataset
		read data set without file meta	information

       input transfer syntax:

	 -t=  --read-xfer-auto
		use TS recognition (default)

	 -td  --read-xfer-detect
		ignore TS specified in the file	meta header

	 -te  --read-xfer-little
		read with explicit VR little endian TS

	 -tb  --read-xfer-big
		read with explicit VR big endian TS

	 -ti  --read-xfer-implicit
		read with implicit VR little endian TS

       parsing of odd-length attributes:

	 +ao  --accept-odd-length
		accept odd length attributes (default)

	 +ae  --assume-even-length
		assume real length is one byte larger

       handling	of undefined length UN elements:

	 +ui  --enable-cp246
		read undefined len UN as implicit VR (default)

	 -ui  --disable-cp246
		read undefined len UN as explicit VR

       handling	of defined length UN elements:

	 -uc  --retain-un
		retain elements	as UN (default)

	 +uc  --convert-un
		convert	to real	VR if known

       automatic data correction:

	 +dc  --enable-correction
		enable automatic data correction (default)

	 -dc  --disable-correction
		disable	automatic data correction

       bitstream format	of deflated input:

	 +bd  --bitstream-deflated
		expect deflated	bitstream (default)

	 +bz  --bitstream-zlib
		expect deflated	zlib bitstream

   processing options
       execution options:

	 -x   --exec  [c]ommand: string
		execute	command	c after	PDF extraction

NOTES
       Option --exec allows for	the execution of a certain command line	 after
       the  creation  of  the PDF document. The	command	line to	be executed is
       passed to this option as	a parameter. The specified  command  line  may
       contain	the  placeholder  '#f',	 which	will  be  replaced  by the PDF
       filename	at run time. The specified command line	 is  executed  in  the
       foreground, i.e.	pdf2dcm	will be	blocked	until the command terminates.

LOGGING
       The  level  of  logging	output	of  the	various	command	line tools and
       underlying libraries can	be specified by	the  user.  By	default,  only
       errors  and  warnings  are  written to the standard error stream. Using
       option --verbose	also informational messages  like  processing  details
       are  reported.  Option  --debug	can be used to get more	details	on the
       internal	activity, e.g. for debugging purposes.	Other  logging	levels
       can  be	selected  using	option --log-level. In --quiet mode only fatal
       errors are reported. In such very severe	error events, the  application
       will  usually  terminate.  For  more  details  on the different logging
       levels, see documentation of module 'oflog'.

       In case the logging output should be written to file  (optionally  with
       logfile	rotation),  to syslog (Unix) or	the event log (Windows)	option
       --log-config can	be used.  This	configuration  file  also  allows  for
       directing  only	certain	messages to a particular output	stream and for
       filtering certain messages based	on the	module	or  application	 where
       they  are  generated.  An  example  configuration  file	is provided in
       <etcdir>/logger.cfg.

EXIT CODES
       The dcm2pdf utility uses	the following  exit  codes  when  terminating.
       This  enables  the  user	 to  check  for	the reason why the application
       terminated.

   general
       EXITCODE_NO_ERROR			 0
       EXITCODE_COMMANDLINE_SYNTAX_ERROR	 1

   input file errors
       EXITCODE_CANNOT_READ_INPUT_FILE		20
       EXITCODE_NO_INPUT_FILES			21
       EXITCODE_INVALID_INPUT_FILE		22

   output file errors
       EXITCODE_CANNOT_WRITE_OUTPUT_FILE	40

   processing errors
       EXITCODE_CANNOT_CONVERT_TO_UNICODE	80
       EXITCODE_CANNOT_WRITE_VALID_JSON		81

COMMAND	LINE
       All command line	tools  use  the	 following  notation  for  parameters:
       square  brackets	 enclose  optional  values  (0-1), three trailing dots
       indicate	that multiple values are allowed (1-n),	a combination of  both
       means 0 to n values.

       Command line options are	distinguished from parameters by a leading '+'
       or  '-' sign, respectively. Usually, order and position of command line
       options are arbitrary (i.e. they	 can  appear  anywhere).  However,  if
       options	are  mutually exclusive	the rightmost appearance is used. This
       behavior	conforms to the	 standard  evaluation  rules  of  common  Unix
       shells.

       In  addition,  one  or more command files can be	specified using	an '@'
       sign as a prefix	to the filename	(e.g. @command.txt).  Such  a  command
       argument	 is  replaced  by  the	content	of the corresponding text file
       (multiple whitespaces are treated as a  single  separator  unless  they
       appear  between	two  quotation marks) prior to any further evaluation.
       Please note that	a command file cannot contain  another	command	 file.
       This  simple  but  effective  approach  allows  one to summarize	common
       combinations of options/parameters and  avoids  longish	and  confusing
       command lines (an example is provided in	file <datadir>/dumppat.txt).

ENVIRONMENT
       The  dcm2pdf  utility  will  attempt  to	 load  DICOM data dictionaries
       specified in the	DCMDICTPATH environment	variable. By default, i.e.  if
       the   DCMDICTPATH   environment	 variable   is	 not   set,  the  file
       <datadir>/dicom.dic will	be loaded unless the dictionary	is built  into
       the application (default	for Windows).

       The   default   behavior	  should  be  preferred	 and  the  DCMDICTPATH
       environment variable only used when alternative data  dictionaries  are
       required.  The  DCMDICTPATH environment variable	has the	same format as
       the Unix	shell PATH variable in that a colon (':')  separates  entries.
       On  Windows systems, a semicolon	(';') is used as a separator. The data
       dictionary code will  attempt  to  load	each  file  specified  in  the
       DCMDICTPATH  environment	variable. It is	an error if no data dictionary
       can be loaded.

SEE ALSO
       pdf2dcm(1)

COPYRIGHT
       Copyright (C) 2007-2024 by OFFIS	e.V., Escherweg	 2,  26121  Oldenburg,
       Germany.

Version	3.6.9			Wed Dec	11 2024			    dcm2pdf(1)