Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
sane-coolscan3(5)	 SANE Scanner Access Now Easy	     sane-coolscan3(5)

NAME
       sane-coolscan3 -	SANE backend for Nikon Coolscan	film scanners

DESCRIPTION
       The  sane-coolscan3 library implements a	SANE (Scanner Access Now Easy)
       backend that provides access to Nikon  Coolscan	film  scanners.	  Some
       functions  of  this backend should be considered	beta-quality software.
       Most functions have been	stable for a long time,	but of course new  de-
       velopment  can  not  and	will not function properly from	the very first
       day.

       At present, the following scanners are known to work with this backend:

	      Model:			   Connection Type
	      ---------------------------  -------------------
	      LS-30 (Coolscan III)	   SCSI
	      LS-40 ED (Coolscan IV)	   USB
	      LS-50 ED (Coolscan V)	   USB
	      LS-2000			   SCSI
	      LS-4000 ED		   IEEE	1394
	      LS-8000 ED		   IEEE	1394

       Please send mail	to sane-devel@alioth-lists.debian.net to  report  suc-
       cesses or failures.

OPTIONS
       The options the backend supports	can either be selected through command
       line  options  to programs like scanimage(1) or through GUI elements in
       xscanimage(1) or	xsane(1).

       Valid command line options and their syntax can be listed by using:

	      scanimage	--help -d coolscan3:<interface>:<device>

       where <interface> and <device> specify the device in  question,	as  in
       the configuration file (see next	section). The -d parameter and its ar-
       gument  can be omitted to obtain	information on the first scanner iden-
       tified. Use the command:

	      scanimage	-L

       to list all devices recognized by your SANE installation.

       The options should be fully described by	the  description  or  tooltips
       given  by frontend. Here	is a description of some of the	most important
       options,	in the syntax with which they  must  be	 supplied  to  scanim-
       age(1):

       --frame <n>
	      This  option specifies which frame to operate on,	if a motorized
	      film strip feeder	or APS adapter are used. The frame number  <n>
	      ranges from 1 to the number of frames available, which is	sensed
	      each  time  the  backend	is  initialized	(usually each time you
	      start the	frontend).

       --subframe <x>
	      This option shifts the scan window by the	specified amount  (de-
	      fault unit is mm).

       --infrared=yes/no
	      If  set  to  "yes",  the scanner will read the infrared channel,
	      thus allowing defect removal in software.	The infrared image  is
	      read  during a second scan, with no options altered. The backend
	      must not be restarted between the	scans.	 If  you  use  scanim-
	      age(1),  perform a batch scan with --batch-count=2 to obtain the
	      IR information.

       --depth <n>
	      Here <n> can either be 8 or the maximum number of	bits supported
	      by the scanner (10, 12, or 14). It specifies whether or not  the
	      scanner  reduces the scanned data	to 8 bits before sending it to
	      the backend. If 8	bits are used, some information	and thus image
	      quality is lost, but the amount of data is smaller  compared  to
	      higher  depths.  Also,  many  imaging programs and image formats
	      cannot handle depths greater than	8 bits.

       --autofocus
	      Perform autofocus	operation. Unless otherwise specified  by  the
	      other options ( --focus-on-centre	and friends), focusing is per-
	      formed on	the centre of the selected scan	area.

       --ae-wb

       --ae   Perform  a  pre-scan to calculate	exposure values	automatically.
	      --ae-wb will maintain the	white balance, while --ae will	adjust
	      each channel separately.

       --exposure
	      Multiply	all  exposure times with this value. This allows expo-
	      sure correction without modifying	white balance.

       --load Load the next slide when using the  slide	 loader	 (SF-200  bulk
	      loader only).

       --eject
	      Eject  the  film	strip  or  mounted  slide when using the slide
	      loader.

       --reset
	      Reset scanner. The scanner will perform the same action as  when
	      power  is	 turned	 on:  it will eject the	slide (with the	SF-200
	      bulk loader) and calibrate itself. Use this whenever the scanner
	      refuses to load a	slide properly,	as a result of	which  --eject
	      does not work.

CONFIGURATION FILE
       The  configuration  file	/usr/local/etc/sane.d/coolscan3.conf specifies
       the device(s) that the backend will use.	Owing to  the  nature  of  the
       supported  connection  types SCSI, USB, and IEEE	1394, the default con-
       figuration file supplied	with the SANE distribution should work without
       being edited.

       Each line in the	configuration file is either of	the  following,	 where
       all entries are case-sensitive:

       blank or	starting with a	'#' character
	      These  lines  are	 ignored, thus '#' can be used to include com-
	      ments.

       containing only the word	"auto"
	      This instructs the backend to probe for a	 scanner  by  scanning
	      the  buses  for  devices with known identifiers. This is the de-
	      fault action when	no configuration file is present.

       a line of the form <interface>:<device>
	      Here <interface> can be one of "scsi" or "usb", and <device>  is
	      the  device file of the scanner. Note that IEEE 1394 devices are
	      handled by the SBP-2 module in the kernel	and appear to SANE  as
	      SCSI devices.

FILES
       /usr/local/lib/sane/libsane-coolscan3.a
	      The static library implementing this backend.

       /usr/local/lib/sane/libsane-coolscan3.so
	      The shared library implementing this backend (present on systems
	      that support dynamic loading).

       /usr/local/etc/sane.d/coolscan3.conf
	      Configuration  file for this backend, read each time the backend
	      is initialized.

ENVIRONMENT
       SANE_DEBUG_COOLSCAN3
	      If the library was compiled with debug support enabled, this en-
	      vironment	variable controls the debug level  for	this  backend.
	      E.g.,  a	value  of 128 requests all debug output	to be printed.
	      Smaller levels reduce verbosity.

SEE ALSO
       sane-scsi(5), sane-usb(5), scanimage(1),	xscanimage(1), xsane(1)

BUGS
       Currently, the SANE protocol does not allow automatically updating  op-
       tions whenever the hardware changes. Thus the number of choices for the
       --frame	option	will be	fixed when the backend is initialized (usually
       when the	user runs the frontend). In particular,	if there  is  no  film
       strip  in  the automatic	film strip feeder when the backend is initial-
       ized, the --frame option	will not appear	at all.	 Also, restarting  the
       frontend	after swapping film adapters is	strongly recommended.

       Linux  kernels  prior to	2.4.19 had a patch that	truncated INQUIRY data
       from IEEE 1394 scanners to 36 bytes, discarding vital information about
       the scanner. The	IEEE 1394 models therefore only	work  with  2.4.19  or
       later.

       No real bugs currently known, please report any to the SANE developers'
       list.

AUTHORS
       coolscan3  written by A.	Zummo <a.zummo@towertech.it>, based heavily on
       coolscan2 written by Andras Major <andras@users.sourceforge.net>.

				  11 Jul 2008		     sane-coolscan3(5)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=sane-coolscan3&sektion=5&manpath=FreeBSD+Ports+14.3.quarterly>

home | help