UPSD(8)				  NUT Manual			       UPSD(8)

NAME
       upsd - Network UPS Tools	data server

SYNOPSIS
       upsd -h

       upsd [OPTIONS]

DESCRIPTION
       upsd is responsible for serving the data	from the drivers to the
       clients.	It connects to each driver and maintains a local cache of the
       current state. Queries from the clients are served from this cache, so
       delays are minimal.

       It also conveys administrative messages from the	clients	back to	the
       drivers,	such as	starting tests,	or setting values.

       Communication between upsd and clients is handled on a TCP port.
       Configuration details for this port are described in upsd.conf(8).

       This program is essential, and must be running at all times to actually
       make any	use out	of the drivers and clients (except for final UPS
       power-off commands just before your server goes down, which NUT driver
       programs	can do alone when called as drivername -k in a shutdown	hook
       or late ordered SysV init script).

       Controls	in the configuration files allow you to	limit access to	the
       server, but you should also use a firewall for extra protection.	Client
       processes such as upsmon(8) trust upsd for status information about the
       UPS hardware, so	keep it	secure.

OPTIONS
       -c command
	   Send	command	to the background process as a signal. Valid commands
	   are:

	   reload
	       reread configuration files

	   stop
	       stop process and	exit

       -P pid
	   Send	the command signal above using specified PID number, rather
	   than	consulting the PID file. This can help define service units
	   which start upsd as a foreground process so it does not create a
	   PID file. See also -FF option as an alternative.

       -D
	   Raise the debugging level. upsd will	run in the foreground by
	   default, and	will print information on stdout about the monitoring
	   process. Use	this option multiple times for more details.

       -F
	   upsd	will run in the	foreground, regardless of debugging settings.
	   Specify twice (-FF or -F -F)	to save	the PID	file even in this
	   mode.

       -B
	   upsd	will run in the	background, regardless of debugging settings.

       -h
	   Display the help text.

       -r directory
	   upsd	will chroot(2) to directory shortly after startup and before
	   parsing any configuration files with	this option set. You can use
	   this	to create a "jail" for greater security.

	   You must coordinate this with your drivers, as upsd must be able to
	   find	the state path within directory. See upsdrvctl(8) and
	   nutupsdrv(8).

       -u user
	   Switch to user user after startup if	started	as root. This
	   overrides whatever you may have compiled in with configure
	   --with-user.

       -V
	   Display the version of the program.

RELOADING
       upsd can	reload its configuration files without shutting	down the
       process if you send it a	SIGHUP or start	it again with -c reload. This
       only works if the background process is able to read those files
       (permissions, chroot jail), and if the daemon did save a	PID file when
       it started (for the reload command to find the older instance).

	   Note

	   Service instances wrapped by	systemd	or SMF might not save them by
	   default -- use respective reload/refresh framework actions instead
	   then), e.g. systemctl reload	nut-server

	   NUT releases	after 2.8.0 define aliases for these units, so if your
	   Linux distribution uses NUT-provided	unit definitions, systemctl
	   reload upsd may also	work.

       If you think that upsd can't reload, check your syslog for error
       messages. If it's complaining about not being able to read the files,
       then you	need to	adjust your system to make it possible.	Either change
       the permissions on the files, or	run upsd as another user that will be
       able to read them, or restart it	fully (may be needed e.g. if running
       in a chroot jail).

       DO NOT make your	upsd.conf(5) or	upsd.users(5) files world-readable, as
       they hold important authentication information. In the wrong hands, it
       could be	used by	some evil person to spoof your primary-mode upsmon and
       command your systems to shut down, for example.

DIAGNOSTICS
       upsd expects the	drivers	to either update their status regularly	or at
       least answer periodic queries, called pings. If a driver	doesn't
       answer, upsd will declare it "stale" and	no more	information will be
       provided	to the clients.

       If upsd complains about staleness when you start	it, then either	your
       driver or configuration files are probably broken. Be sure that the
       driver is actually running, and that the	UPS definition in ups.conf(5)
       is correct. Also	make sure that you start your driver(s)	before
       starting	upsd.

       Data can	also be	marked stale if	the driver can no longer communicate
       with the	UPS. In	this case, the driver should also provide diagnostic
       information in the syslog. If this happens, check the serial or USB
       cabling,	or inspect the network path in the case	of a SNMP UPS.

ACCESS CONTROL
       If the server is	build with tcp-wrappers	support	enabled, it will check
       if the NUT username is allowed to connect from the client address
       through the /etc/hosts.allow and	/etc/hosts.deny	files. Note that this
       will only be done for commands that require to be logged	into the
       server. Further details are described in	hosts_access(5).

FILES
       The general upsd	configuration file is upsd.conf(5).

       The administrative functions like SET and INSTCMD for users, and
       various upsmon roles, are defined and controlled	in upsd.users(5).

       UPS definitions are found in ups.conf(5)	(shared	with actual drivers).

ENVIRONMENT VARIABLES
       NUT_DEBUG_LEVEL sets default debug verbosity if no -D arguments were
       provided	on command line, but does not request that the daemon runs in
       foreground mode.

       NUT_CONFPATH is the path	name of	the directory that contains upsd.conf
       and other configuration files. If this variable is not set, upsd	uses a
       built-in	default, which is often	/usr/local/etc.

       NUT_STATEPATH is	the path name of the directory in which	upsd keeps
       state information. If this variable is not set, upsd uses a built-in
       default,	which is often /var/state/ups. The STATEPATH directive in
       upsd.conf(5) overrides this variable.

       NUT_ALTPIDPATH is the path name of the directory	in which upsd and
       drivers store .pid files. If this variable is not set, upsd and drivers
       use either NUT_STATEPATH	if set,	or ALTPIDPATH if set, or otherwise the
       built-in	default	STATEPATH.

       NUT_QUIET_INIT_UPSNOTIFY=true can be used to prevent daemons which can
       notify service management frameworks (such as systemd) about passing
       their lifecycle milestones from emitting	such notifications (including
       those about lack	of system support for such modern features, once per
       run).

       NUT_QUIET_INIT_BANNER=true can be used to suppress NUT tool name	and
       version banner. NOT recommended for services due	to adverse
       troubleshooting impact, but may be helpful in shell profiles or scripts
       which process NUT tool outputs.

SEE ALSO
   Clients:
          upsc(8)

          upscmd(8)

          upsrw(8)

          upslog(8)

          upsmon(8)

   CGI programs:
          upsset.cgi(8)

          upsstats.cgi(8)

          upsimage.cgi(8)

   Driver control:
          nut-driver-enumerator(8)

          upsdrvctl(8)

          upsdrvsvcctl(8)

   Drivers:
          nutupsdrv(8)

          adelsystem_cbi(8)

          al175(8)

          apc_modbus(8)

          apcsmart-old(8)

          apcsmart(8)

          apcupsd-ups(8)

          asem(8)

          bcmxcp(8)

          bcmxcp_usb(8)

          belkin(8)

          belkinunv(8)

          bestfcom(8)

          bestfortress(8)

          bestuferrups(8)

          bestups(8)

          bicker_ser(8)

          blazer-common(8)

          blazer_ser(8)

          blazer_usb(8)

          clone-outlet(8)

          clone(8)

          dummy-ups(8)

          etapro(8)

          everups(8)

          gamatronic(8)

          generic_gpio(8)

          generic_modbus(8)

          genericups(8)

          huawei-ups2000(8)

          hwmon_ina219(8)

          isbmex(8)

          ivtscd(8)

          liebert-esp2(8)

          liebert-gxe(8)

          liebert(8)

          macosx-ups(8)

          masterguard(8)

          metasys(8)

          mge-shut(8)

          mge-utalk(8)

          microdowell(8)

          microsol-apc(8)

          netxml-ups(8)

          nhs_ser(8)

          nut-ipmipsu(8)

          nut_usb_addvars(8)

          nutdrv_atcl_usb(8)

          nutdrv_qx(8)

          nutdrv_siemens_sitop(8)

          oneac(8)

          optiups(8)

          phoenixcontact_modbus(8)

          pijuice(8)

          powercom(8)

          powerman-pdu(8)

          powerpanel(8)

          rhino(8)

          richcomm_usb(8)

          riello_ser(8)

          riello_usb(8)

          safenet(8)

          sms_ser(8)

          snmp-ups(8)

          socomec_jbus(8)

          solis(8)

          tripplite(8)

          tripplite_usb(8)

          tripplitesu(8)

          upscode2(8)

          usbhid-ups(8)

          victronups(8)

   Internet resources:
       The NUT (Network	UPS Tools) home	page: https://www.networkupstools.org/

Network	UPS Tools 2.8.2.	  04/17/2025			       UPSD(8)