NAME
       k8temp  --  display  on-die  temperature	 readings  from	AMD K8 and K10
       processors

SYNOPSIS
       k8temp [-nd] [selector ...] | [-v | -h]

DESCRIPTION
       The k8temp utility displays temperature readings	from AMD  K8  and  K10
       processors using	their on-die thermal diode(s).

       k8temp  requires	read-write access to /dev/pci, and thus	must be	run as
       root.

       The following options are available:

       -v      Display version and copyright information.

       -h      Display help text.

       -n      Show only temperature values.

       -d      Display debug information, including raw	register contents  and
	       interpreted subvalues, and an Advanced Power Management feature
	       dump.

       Selectors  specify  which  CPU, core and	sensor to read,	and are	of the
       form cpu[:core[:sensor]].  Note,	output order is	fixed, and  not	 (yet)
       defined by the order of selectors.

EXAMPLES
       k8temp 1:0:0
		Display	reading	for CPU1, core 0, sensor 0.

       k8temp 1:0
		Display	reading	for CPU1, core 0, all available	sensors.

       k8temp -d 0 2
		Display	 reading  for  CPU 0 and CPU2, all available cores and
		sensors.  Display debug	output.

BUGS
       k8temp may cause	unsupported systems to reboot, crash or	explode.

       Core numbers on single core systems may be incorrect (e.g. core	1  but
       no core 0).

       Running	multiple copies	of k8temp at once could	result in readings be-
       ing taken from incorrect	cores.

       Readings	from K10's are experimental.  Limited testing suggests they're
       10-20 degrees too low.

HISTORY
       0.1.0, 2007-10-21
	       First release.

       0.1.1, 2007-10-22
	       Fixes a serious error resulting in writes to a bogus PCI	regis-
	       ter.

       0.2.0, 2007-10-25
	       Add support for diode offset correction and debugging  options.
	       Add CPUID check.

       0.3.0, 2007-12-04
	       Add tentative support for OpenBSD and NetBSD.  Remove (meaning-
	       less)  diode  offset  correction.   Introduce value-only	output
	       mode and	sensor selector	arguments.

       0.4.0, 2008-06-22
	       Add preliminary K10 (Barcelona/Phenom) support.

SEE ALSO
       BIOS and	Kernel Developer's Guide for AMD NPT  Family  0fh  Processors.
       Section 4.6.23, Thermtrip Status	Register.

       AMD  CPUID  Specification, CPUID	Fn8000_0007, Advanced Power Management
       Information.

       BIOS and	Kernel Developer's Guide For AMD Family	10h Processors.	  Sec-
       tion 3.6.F3xA4, Reported	Temperature Control Register.

AUTHOR
       Thomas Hurst <tom@hur.st>

FreeBSD	ports 15.0	       October 21, 2007			     K8TEMP(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=k8temp&sektion=8&manpath=FreeBSD+Ports+15.0>

home | help