Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
mDI001(3)		     One-Wire File System		     mDI001(3)

NAME
       mDI001 -	Digital	Input Module

SYNOPSIS
   Monitor 4 digital lines
       A5      [.]XXXXXXXXXXXX[XX][/[	   switch_closed.[0-3|ALL|BYTE]	     |
       loop_open.[0-3|ALL|BYTE]	| loop_shorted.[0-3|ALL|BYTE] |	address	| crc8
       | id | locator |	r_address | r_id | r_locator | type ]]

FAMILY CODE
       A5

SPECIAL	PROPERTIES
   switch_closed.[0-3|ALL|BYTE]
       read-only, yes-no
       Is the relay closed? (1=yes, 0=no).

       Note that OWFS uses 0 through 3 as the index and	the datasheet  uses  1
       through 4.

   loop_shorted.[0-3|ALL|BYTE]
       read-only, yes-no
       Is the loop shorted? (1=yes, 0=no). Failsafe mode.

       Note  that  OWFS	uses 0 through 3 as the	index and the datasheet	uses 1
       through 4.

   loop_open.[0-3|ALL|BYTE]
       read-only, yes-no
       Is the loop open? (1=yes, 0=no).	Failsafe mode.

       Note that OWFS uses 0 through 3 as the index and	the datasheet  uses  1
       through 4.

STANDARD PROPERTIES
   address
   r_address
       read-only, ascii
       The  entire  64-bit  unique  ID.	Given as upper case hexadecimal	digits
       (0-9A-F).
       address starts with the family code
       r address is the	address	in reverse order, which	is often used in other
       applications and	labeling.

   crc8
       read-only, ascii
       The 8-bit error correction portion. Uses	cyclic redundancy check.  Com-
       puted  from the preceding 56 bits of the	unique ID number. Given	as up-
       per case	hexadecimal digits (0-9A-F).

   family
       read-only, ascii
       The 8-bit family	code. Unique to	each type of device.  Given  as	 upper
       case hexadecimal	digits (0-9A-F).

   id
   r_id
       read-only, ascii
       The 48-bit middle portion of the	unique ID number. Does not include the
       family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
       r  id is	the id in reverse order, which is often	used in	other applica-
       tions and labeling.

   locator
   r_locator
       read-only, ascii
       Uses an extension of the	1-wire design from  iButtonLink	 company  that
       associated  1-wire  physical  connections with a	unique 1-wire code. If
       the connection is behind	a Link Locator the locator will	show a	unique
       8-byte number (16 character hexadecimal)	starting with family code FE.
       If  no  Link  Locator is	between	the device and the master, the locator
       field will be all FF.
       r locator is the	locator	in reverse order.

   present (DEPRECATED)
       read-only, yes-no
       Is the device currently present on the 1-wire bus?

   type
       read-only, ascii
       Part name assigned by Dallas Semi. E.g.	DS2401	Alternative  packaging
       (iButton	vs chip) will not be distiguished.

ALARMS
       None.

DESCRIPTION
   1-Wire
       1-wire is a wiring protocol and series of devices designed and manufac-
       tured  by  Dallas  Semiconductor, Inc. The bus is a low-power low-speed
       low-connector scheme where the data line	can also provide power.

       Each device is uniquely and unalterably	numbered  during  manufacture.
       There  are a wide variety of devices, including memory, sensors (humid-
       ity, temperature, voltage, contact, current), switches, timers and data
       loggers.	More complex devices (like thermocouple	sensors) can be	 built
       with  these  basic devices. There are also 1-wire devices that have en-
       cryption	included.

       The 1-wire scheme uses a	single bus master and multiple slaves  on  the
       same  wire.  The	bus master initiates all communication.	The slaves can
       be individually discovered and addressed	using their unique ID.

       Bus masters come	in a variety of	configurations including serial,  par-
       allel, i2c, network or USB adapters.

   OWFS	design
       OWFS  is	 a  suite of programs that designed to make the	1-wire bus and
       its devices easily accessible. The underlying principle is to create  a
       virtual filesystem, with	the unique ID being the	directory, and the in-
       dividual	 properties of the device are represented as simple files that
       can be read and written.

       Details of the individual slave or master design	are  hidden  behind  a
       consistent interface. The goal is to provide an easy set	of tools for a
       software	 designer  to create monitoring	or control applications. There
       are some	performance enhancements in the	implementation,	including data
       caching,	parallel access	to bus masters,	and aggregation	of device com-
       munication. Still the fundamental goal has been ease of use,  flexibil-
       ity and correctness rather than speed.

   mDI001
       The mDI001 (3) is used to monitor digital lines for simple switching.

ADDRESSING
       All  1-wire  devices are	factory	assigned a unique 64-bit address. This
       address is of the form:

       Family Code
	      8	bits

       Address
	      48 bits

       CRC    8	bits

       Addressing under	OWFS is	in hexadecimal,	of form:

	      01.123456789ABC

       where 01	is an example 8-bit family code, and 12345678ABC is an example
       48 bit address.

       The dot is optional, and	the CRC	code can  included.  If	 included,  it
       must be correct.

WEBSITE
       http://www.cmciel.com/products-solutions/individual-products/4-channel-
       fail-safe-digital-module-mdi001/

   Programs
       owfs  (1)  owhttpd  (1)	owftpd	(1)  owserver (1) owdir	(1) owread (1)
       owwrite (1) owpresent (1) owtap (1)

   Configuration and testing
       owfs (5)	owtap (1) owmon	(1)

   Language bindings
       owtcl (3) owperl	(3) owcapi (3)

   Clocks
       DS1427 (3) DS1904 (3) DS1994 (3)	DS2404	(3)  DS2404S  (3)  DS2415  (3)
       DS2417 (3)

   ID
       DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
       DS1982  (3)  DS1985  (3)	 DS1986	 (3)  DS1991 (3) DS1992	(3) DS1993 (3)
       DS1995 (3) DS1996 (3) DS2430A (3) DS2431	 (3)  DS2433  (3)  DS2502  (3)
       DS2506 (3) DS28E04 (3) DS28EC20 (3)

   Switches
       DS2405 (3) DS2406 (3) DS2408 (3)	DS2409 (3) DS2413 (3) DS28EA00 (3) In-
       fernoEmbedded (3)

   Temperature
       DS1822  (3)  DS1825  (3)	 DS1820	(3) DS18B20 (3)	DS18S20	(3) DS1920 (3)
       DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065  (3)
       EDS0066	(3)  EDS0067  (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826
       (3)

   Humidity
       DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
       DS2450 (3)

   Resistance
       DS2890 (3)

   Multifunction (current, voltage, temperature)
       DS2436 (3) DS2437 (3) DS2438 (3)	 DS2751	 (3)  DS2755  (3)  DS2756  (3)
       DS2760 (3) DS2770 (3) DS2780 (3)	DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
       DS2423 (3)

   LCD Screen
       LCD (3) DS2408 (3)

   Crypto
       DS1977 (3)

   Pressure
       DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
       EEEF (3)	DS2438 (3)

AVAILABILITY
       http://www.owfs.org

AUTHOR
       Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			     2003			     mDI001(3)