modbus_rtu_set_rts()					  modbus_rtu_set_rts()

Name
       modbus_rtu_set_rts - set	the RTS	mode in	RTU

Synopsis
       int modbus_rtu_set_rts(modbus_t *ctx, int mode)

Description
       The modbus_rtu_set_rts()	function shall set the Request To Send mode to
       communicate on a	RS-485 serial bus. By default, the mode	is set to MOD-
       BUS_RTU_RTS_NONE	 and  no  signal  is issued before writing data	on the
       wire.

       To  enable  the	RTS  mode,  the	 values	 MODBUS_RTU_RTS_UP   or	  MOD-
       BUS_RTU_RTS_DOWN	 must be used, these modes enable the RTS mode and set
       the polarity at the same	time. When MODBUS_RTU_RTS_UP is	used, an ioctl
       call is made with RTS flag enabled then data is written on the bus  af-
       ter  a delay of 1 ms, then another ioctl	call is	made with the RTS flag
       disabled	and again a delay of 1	ms  occurs.   The  MODBUS_RTU_RTS_DOWN
       mode applies the	same procedure but with	an inverted RTS	flag.

       This function can only be used with a context using a RTU backend.

Return value
       The function shall return 0 if successful. Otherwise it shall return -1
       and set errno to	one of the values defined below.

Errors
        EINVAL, the libmodbus backend isn't RTU or the	mode given in argument
	 is invalid.

Example
       Enable the RTS mode with	positive polarity:

       modbus_t	*ctx;
       uint16_t	tab_reg[10];

       ctx = modbus_new_rtu("/dev/ttyS0", 115200, 'N', 8, 1);
       modbus_set_slave(ctx, 1);
       modbus_rtu_set_serial_mode(ctx, MODBUS_RTU_RS485);
       modbus_rtu_set_rts(ctx, MODBUS_RTU_RTS_UP);

       if (modbus_connect(ctx) == -1) {
	   fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
	   modbus_free(ctx);
	   return -1;
       }

       rc = modbus_read_registers(ctx, 0, 7, tab_reg);
       if (rc == -1) {
	   fprintf(stderr, "%s\n", modbus_strerror(errno));
	   return -1;
       }

       modbus_close(ctx);
       modbus_free(ctx);