Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
DS2413(3)		      One-Wire File System		       DS2413(3)

NAME
     DS2413 - Dual Channel Addressable Switch

SYNOPSIS
     Dual Switch

     3A  [.]XXXXXXXXXXXX[XX][/[ PIO.[A|B|ALL|BYTE] | sensed.[A|B|ALL|BYTE] | ad-
     dress | crc8 | id | locator | r_address | r_id | r_locator | type ]]

FAMILY CODE
     3A

SPECIAL PROPERTIES
   PIO.A PIO.B PIO.ALL PIO.BYTE
     read-write, yes-no
     State of the open-drain output ( PIO ) pin. 0 = non-conducting (off),  1  =
     conducting (on).
     Writing  zero  will  turn off the switch, non-zero will turn on the switch.
     Reading the PIO state will return the switch setting. To determine the  ac-
     tual logic level at the switch, refer to the sensed property.
     ALL references both channels simultaneously, comma separated.
     BYTE references both channels simultaneously as a single byte, with channel
     A in bit 0.

   sensed.A sensed.B sensed.ALL sensed.BYTE
     read-only, yes-no
     Logic  level  at  the  PIO  pin. 0 = ground. 1 = high (~2.4V - 5V ). Really
     makes sense only if the PIO state is set to  zero	(off),	else  will  read
     zero.
     ALL references both channels simultaneously, comma separated.
     BYTE references both channels simultaneously as a single byte, with channel
     A in bit 0.

STANDARD PROPERTIES
   address
   r_address
     read-only, ascii
     The  entire 64-bit unique ID. Given as upper case hexadecimal digits (0-9A-
     F).
     address starts with the family code
     r address is the address in reverse order, which is often used in other ap-
     plications and labeling.

   crc8
     read-only, ascii
     The 8-bit error correction portion. Uses cyclic redundancy check.	Computed
     from  the	preceding  56  bits of the unique ID number. Given as upper case
     hexadecimal digits (0-9A-F).

   family
     read-only, ascii
     The 8-bit family code. Unique to each type of device. Given as  upper  case
     hexadecimal digits (0-9A-F).

   id
   r_id
     read-only, ascii
     The  48-bit  middle  portion  of the unique ID number. Does not include the
     family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
     r id is the id in reverse order, which is often used in other  applications
     and labeling.

   locator
   r_locator
     read-only, ascii
     Uses  an extension of the 1-wire design from iButtonLink company that asso-
     ciated 1-wire physical connections with a unique 1-wire code. If  the  con-
     nection is behind a Link Locator the locator will show a unique 8-byte num-
     ber (16 character hexadecimal) starting with family code FE.
     If  no Link Locator is between the device and the master, the locator field
     will be all FF.
     r locator is the locator in reverse order.

   present (DEPRECATED)
     read-only, yes-no
     Is the device currently present on the 1-wire bus?

   type
     read-only, ascii
     Part name assigned by  Dallas  Semi.  E.g.   DS2401  Alternative  packaging
     (iButton vs chip) will not be distiguished.

ALARMS
     Use the set_alarm property to set the alarm triggering criteria.

DESCRIPTION
   1-Wire
     1-wire is a wiring protocol and series of devices designed and manufactured
     by  Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connec-
     tor scheme where the data line can also provide power.

     Each device is uniquely and unalterably numbered during manufacture.  There
     are a wide variety of devices, including memory, sensors (humidity, temper-
     ature,  voltage, contact, current), switches, timers and data loggers. More
     complex devices (like thermocouple sensors) can be built with  these  basic
     devices. There are also 1-wire devices that have encryption included.

     The  1-wire scheme uses a single bus master and multiple slaves on the same
     wire. The bus master initiates all communication. The slaves can  be  indi-
     vidually discovered and addressed using their unique ID.

     Bus masters come in a variety of configurations including serial, parallel,
     i2c, network or USB adapters.

   OWFS design
     OWFS  is  a  suite of programs that designed to make the 1-wire bus and its
     devices easily accessible. The underlying principle is to create a  virtual
     filesystem,  with	the  unique  ID  being the directory, and the individual
     properties of the device are represented as simple files that can	be  read
     and written.

     Details  of  the individual slave or master design are hidden behind a con-
     sistent interface. The goal is to provide an easy set of tools for a  soft-
     ware  designer to create monitoring or control applications. There are some
     performance enhancements in the  implementation,  including  data	caching,
     parallel  access  to  bus masters, and aggregation of device communication.
     Still the fundamental goal has been ease of use, flexibility  and	correct-
     ness rather than speed.

   DS2413
     The  DS2413  (3)  allows control of other devices, like LEDs and relays. It
     differs from the DS2405 with a  cleaner  interface  and  two  channels  The
     DS2413  also has two channels like the DS2406 and DS2407 but has no memory,
     and no alarm.  There is also varying types of switch  and	sensing  in  the
     DS2408, DS2409, LCD, DS276x, DS2450.
     Unique  among  the  switches,  the DS2413 can switch higher voltages, up to
     28V.

ADDRESSING
     All 1-wire devices are factory assigned a unique 64-bit address.  This  ad-
     dress is of the form:

     Family Code
	    8 bits

     Address
	    48 bits

     CRC    8 bits

     Addressing under OWFS is in hexadecimal, of form:

	    01.123456789ABC

     where  01 is an example 8-bit family code, and 12345678ABC is an example 48
     bit address.

     The dot is optional, and the CRC code can included. If included, it must be
     correct.

DATASHEET
     http://datasheets.maxim-ic.com/en/ds/DS2413.pdf

SEE ALSO
   Programs
     owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread  (1)  owwrite
     (1) owpresent (1) owtap (1)

   Configuration and testing
     owfs (5) owtap (1) owmon (1)

   Language bindings
     owtcl (3) owperl (3) owcapi (3)

   Clocks
     DS1427  (3)  DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417
     (3)

   ID
     DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
     DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3)  DS1993  (3)  DS1995
     (3)  DS1996  (3)  DS2430A	(3)  DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3)
     DS28E04 (3) DS28EC20 (3)

   Switches
     DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3)  Infer-
     noEmbedded (3)

   Temperature
     DS1822  (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921
     (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
     EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

   Humidity
     DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
     DS2450 (3)

   Resistance
     DS2890 (3)

   Multifunction (current, voltage, temperature)
     DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3)  DS2756  (3)  DS2760
     (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
     DS2423 (3)

   LCD Screen
     LCD (3) DS2408 (3)

   Crypto
     DS1977 (3)

   Pressure
     DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
     EEEF (3) DS2438 (3)

AVAILABILITY
     http://www.owfs.org

AUTHOR
     Paul Alfille (paul.alfille@gmail.com)