Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
DS2450(3)		      One-Wire File System		       DS2450(3)

NAME
     DS2450 - Quad A/D Converter

SYNOPSIS
   Voltage * 4 and Memory.
     20  [.]XXXXXXXXXXXX[XX][/[ PIO.[A-D|ALL] | volt.[A-D|ALL] | volt2.[A-D|ALL]
     | latestvolt.[A-D|ALL] | latestvolt2.[A-D|ALL] ]]

     20  [.]XXXXXXXXXXXX[XX][/[  8bit/volt.[A-D|ALL]  |  8bit/volt2.[A-D|ALL]  |
     8bit/latestvolt.[A-D|ALL] | 8bit/latestvolt2.[A-D|ALL] ]]

     20 [.]XXXXXXXXXXXX[XX][/[ memory | pages/page.[0-3|ALL] | power ]

     20  [.]XXXXXXXXXXXX[XX][/[  alarm/high.[A-D|ALL]  |  alarm/low.[A-D|ALL]  |
     set_alarm/high.[A-D|ALL]  |  set_alarm/low.[A-D|ALL]  |  set_alarm/unset  |
     set_alarm/volthigh.[A-D|ALL]      |     set_alarm/volt2high.[A-D|ALL]     |
     set_alarm/voltlow.[A-D|ALL] | set_alarm/volt2low.[A-D|ALL] ]

     20 [.]XXXXXXXXXXXX[XX][/[ address | crc8 | id | locator | r_address |  r_id
     | r_locator | type ]]

   CO2 sensor
     20 [.]XXXXXXXXXXXX[XX][/[ CO2/ppm | CO2/power | CO2/status ]

FAMILY CODE
     20

SPECIAL PROPERTIES
   alarm/high.A ... alarm/high.D alarm.high.ALL
   alarm/high.A ... alarm/high.D alarm.high.ALL
     read-write, binary
     The  alarm  state of the voltage channel. The alarm state is set one of two
     ways:

     voltage conversion
	    Whenever the DS2450 measures a voltage on a channel, that voltage is
	    compared to  the  high  and  low  limits  set_alarm/volthigh  and/or
	    set_alarm/voltlow  and if the alarm is enabled set_alarm/high and/or
	    set_alarm/low the corresponding flag is  set  in  alarm/high  and/or
	    alarm/low

     manual set
	    The flag can be set by a direct write to alarm/high or alarm/low

   memory
     read-write, binary
     32 bytes of data. Much has special implications. See the datasheet.

   pages/page.0 ... pages/page.3 pages/page.ALL
     read-write, binary
     Memory  is  split into 4 pages of 8 bytes each. Mostly for reading and set-
     ting device properties. See the datasheet for details.
     ALL is an aggregate of the pages. Each page is accessed sequentially.

   PIO.A ... PIO.D PIO.ALL
     read-write, yes-no
     Pins used for digital control. 1 turns the switch on (conducting). 0  turns
     the switch off (non-conducting).
     Control is specifically enabled. Reading volt will turn off this control.
     ALL is an aggregate of the voltages. Readings are made separately.

   power
     read-write, yes-no
     Configure whether the DS2450 is externally powered (as opposed to parasiti-
     cally powered from the data line).
     If  configured  as powered, the A/D coverter will be set to continuous sam-
     pling, and the bus will be released during  a  single  conversion	allowing
     other devices to communicate.
     Setting this to 1 when no power is applied to the chip's Vcc will result in
     wrong  voltage  readouts.	 Setting  this to 0 when power is applied to the
     chip's Vcc allows a simultaneous conversion trigger on all DS2450 on a bus.
     The (always safe) default is 0.

   set_alarm/high.A ... set_alarm/high.D set_alarm/high.ALL
   set_alarm/low.A ... set_alarm/low.D set_alarm/low.ALL
     read-write, yes-no
     Enabled status of the voltage threshold. 1 is on. 0 is off.

   set_alarm/volthigh.A ... set_alarm/volthigh.D set_alarm/volthigh.ALL
   set_alarm/volt2high.A ... set_alarm/volt2high.D set_alarm/volt2high.ALL
   set_alarm/voltlow.A ... set_alarm/voltlow.D set_alarm/voltlow.ALL
   set_alarm/volt2low.A ... set_alarm/volt2low.D set_alarm/volt2low.ALL
     read-write, floating point
     The upper or lower limit for the  voltage	measured  before  triggering  an
     alarm.
     Note  that  the alarm must be enabled alarm/high or alarm.low and an actual
     reading must be requested volt for the alarm state to actually be set.  The
     alarm state can be sensed at alarm/high and alarm/low

   set_alarm/unset
     read-write, yes-no
     Status of the power-on-reset (POR) flag.
     The  POR  is  set	when  the DS2450 is first powered up, and will match the
     alarm state until explicitly cleared. (By writing 0 to it).
     The purpose of the POR is to alert the user that the chip is not yet  fully
     configured, especially alarm thresholds and enabling.

   volt.A ... volt.D volt.ALL
   volt2.A ... volt2.D volt2.ALL
   8bit/volt.A ... 8bit/volt.D 8bit/volt.ALL
   8bit/volt2.A ... 8bit/volt2.D 8bit/volt2.ALL
     read-only, floating point
     Reading  one  of these nodes triggers a conversion on the specified voltage
     input(s) with the selected resolution (16 or 8 bit) and returns the sampled
     voltage(s) with the selected scaling (0 - 5.10V or 0 - 2.55V).  The conver-
     sion time is about 1.4ms per input for  16-bit  and  0.8ms  per  input  for
     8-bit.  The output feature ( PIO ) is disabled by reading the corresponding
     node.
     ALL is an aggregate of the voltages. Sampling is controlled by the chip and
     done in the order A, B, C, D, one after another.

   latestvolt.A ... latestvolt.D latestvolt.ALL
   latestvolt2.A ... latestvolt2.D latestvolt2.ALL
   8bit/latestvolt.A ... 8bit/latestvolt.D 8bit/latestvolt.ALL
   8bit/latestvolt2.A ... 8bit/latestvolt2.D 8bit/latestvolt2.ALL
     read-only, floating point
     Returns  previously measured voltage on the specified input(s) with the se-
     lected scaling (0 - 5.10V or 0 - 2.55V).  Resolution and scaling are set by
     sampling a voltage, not here; the correct latestvolt nodes have to be  read
     to make the result meaningful.
     ALL is an aggregate of the voltages and returns all voltage values from the
     chip.
     Reading  these  nodes will never trigger a voltage conversion. Intended for
     use in conjunction with /simultaneous/voltage.

CO2 (Carbon Dioxide) SENSOR PROPERTIES
     The CO2 sensor is a device constructed from a SenseAir K30 and a DS2450

   CO2/power
     read-only, floating point
     Supply voltage to the CO2 sensor (should be around 5V)

   CO2/ppm
     read-only, unsigned
     CO2 level in ppm (parts per million). Range 0-5000.

   CO2/status
     read-only, yes-no
     Is the internal voltage correct (around 3.2V)?

STANDARD PROPERTIES
   address
   r_address
     read-only, ascii
     The entire 64-bit unique ID. Given as upper case hexadecimal digits  (0-9A-
     F).
     address starts with the family code
     r address is the address in reverse order, which is often used in other ap-
     plications and labeling.

   crc8
     read-only, ascii
     The  8-bit error correction portion. Uses cyclic redundancy check. Computed
     from the preceding 56 bits of the unique ID number.  Given  as  upper  case
     hexadecimal digits (0-9A-F).

   family
     read-only, ascii
     The  8-bit  family code. Unique to each type of device. Given as upper case
     hexadecimal digits (0-9A-F).

   id
   r_id
     read-only, ascii
     The 48-bit middle portion of the unique ID number.  Does  not  include  the
     family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
     r	id is the id in reverse order, which is often used in other applications
     and labeling.

   locator
   r_locator
     read-only, ascii
     Uses an extension of the 1-wire design from iButtonLink company that  asso-
     ciated  1-wire  physical connections with a unique 1-wire code. If the con-
     nection is behind a Link Locator the locator will show a unique 8-byte num-
     ber (16 character hexadecimal) starting with family code FE.
     If no Link Locator is between the device and the master, the locator  field
     will be all FF.
     r locator is the locator in reverse order.

   present (DEPRECATED)
     read-only, yes-no
     Is the device currently present on the 1-wire bus?

   type
     read-only, ascii
     Part  name  assigned  by  Dallas  Semi.  E.g.  DS2401 Alternative packaging
     (iButton vs chip) will not be distiguished.

ALARMS
     None.

DESCRIPTION
   1-Wire
     1-wire is a wiring protocol and series of devices designed and manufactured
     by Dallas Semiconductor, Inc. The bus is a low-power low-speed  low-connec-
     tor scheme where the data line can also provide power.

     Each  device is uniquely and unalterably numbered during manufacture. There
     are a wide variety of devices, including memory, sensors (humidity, temper-
     ature, voltage, contact, current), switches, timers and data loggers.  More
     complex  devices  (like thermocouple sensors) can be built with these basic
     devices. There are also 1-wire devices that have encryption included.

     The 1-wire scheme uses a single bus master and multiple slaves on the  same
     wire.  The  bus master initiates all communication. The slaves can be indi-
     vidually discovered and addressed using their unique ID.

     Bus masters come in a variety of configurations including serial, parallel,
     i2c, network or USB adapters.

   OWFS design
     OWFS is a suite of programs that designed to make the 1-wire  bus	and  its
     devices  easily accessible. The underlying principle is to create a virtual
     filesystem, with the unique ID being  the	directory,  and  the  individual
     properties  of  the device are represented as simple files that can be read
     and written.

     Details of the individual slave or master design are hidden behind  a  con-
     sistent  interface. The goal is to provide an easy set of tools for a soft-
     ware designer to create monitoring or control applications. There are  some
     performance  enhancements	in  the  implementation, including data caching,
     parallel access to bus masters, and aggregation  of  device  communication.
     Still  the  fundamental goal has been ease of use, flexibility and correct-
     ness rather than speed.

   DS2450
     The DS2450 (3) is a (supposedly) high resolution A/D converter with 4 chan-
     nels. Actual resolutin is reporterd to be 8 bits.	The  channels  can  also
     function  as  switches.  Voltage sensing (with temperature and current, but
     sometimes restricted voltrage ranges) can also be obtained with the  DS2436
     , DS2438 and DS276x

ADDRESSING
     All  1-wire  devices are factory assigned a unique 64-bit address. This ad-
     dress is of the form:

     Family Code
	    8 bits

     Address
	    48 bits

     CRC    8 bits

     Addressing under OWFS is in hexadecimal, of form:

	    01.123456789ABC

     where 01 is an example 8-bit family code, and 12345678ABC is an example  48
     bit address.

     The dot is optional, and the CRC code can included. If included, it must be
     correct.

DATASHEET
     DS2450
	    http://pdfserv.maxim-ic.com/en/ds/DS2450.pdf

     CO2 sensor
	    http://www.senseair.se/Datablad/k30%20.pdf

     CO2 device
	    https://www.m.nu/co2meter-version-2-p-259.html?language=en

SEE ALSO
   Programs
     owfs  (1)	owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite
     (1) owpresent (1) owtap (1)

   Configuration and testing
     owfs (5) owtap (1) owmon (1)

   Language bindings
     owtcl (3) owperl (3) owcapi (3)

   Clocks
     DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415  (3)  DS2417
     (3)

   ID
     DS2401 (3) DS2411 (3) DS1990A (3)

   Memory
     DS1982  (3)  DS1985  (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995
     (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433  (3)	DS2502	(3)  DS2506  (3)
     DS28E04 (3) DS28EC20 (3)

   Switches
     DS2405  (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) Infer-
     noEmbedded (3)

   Temperature
     DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3)  DS1921
     (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3)
     EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)

   Humidity
     DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)

   Voltage
     DS2450 (3)

   Resistance
     DS2890 (3)

   Multifunction (current, voltage, temperature)
     DS2436  (3)  DS2437  (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760
     (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)

   Counter
     DS2423 (3)

   LCD Screen
     LCD (3) DS2408 (3)

   Crypto
     DS1977 (3)

   Pressure
     DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)

   Moisture
     EEEF (3) DS2438 (3)

AVAILABILITY
     http://www.owfs.org

AUTHOR
     Paul Alfille (paul.alfille@gmail.com)

OWFS Manpage			      2003			       DS2450(3)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=DS2450&sektion=3&manpath=FreeBSD+Ports+15.1.quarterly>

home | help