Smokeping_probes_Radius(3)	    SmokePing	      Smokeping_probes_Radius(3)

NAME
     Smokeping::probes::Radius - a RADIUS authentication probe for SmokePing

OVERVIEW
     Measures RADIUS authentication latency for SmokePing

SYNOPSIS
      *** Probes ***

      +Radius

      forks = 5
      offset = 50%
      passwordfile = /some/place/secret
      secretfile = /another/place/secret
      step = 300

      # The following variables can be overridden in each target section
      /^influx_.+/ = influx_location = In the basement
      allowreject = true
      mininterval = 1
      nas_ip_address = 10.1.2.3
      password = test-password
      pings = 5
      port = 1645
      secret = test-secret
      timeout = 5
      username = test-user # mandatory

      # [...]

      *** Targets ***

      probe = Radius # if this should be the default probe

      # [...]

      + mytarget
      # probe = Radius # if the default probe is something else
      host = my.host
      /^influx_.+/ = influx_location = In the basement
      allowreject = true
      mininterval = 1
      nas_ip_address = 10.1.2.3
      password = test-password
      pings = 5
      port = 1645
      secret = test-secret
      timeout = 5
      username = test-user # mandatory

DESCRIPTION
     This probe measures RADIUS (RFC 2865) authentication latency for SmokePing.

     The username to be tested is specified in either the probe-specific or the
     target-specific variable `username', with the target-specific one overrid-
     ing the probe-specific one.

     The password can be specified either (in order of precedence, with the lat-
     ter overriding the former) in the probe-specific variable `password', in an
     external file or in the target-specific variable `password'.  The location
     of this file is given in the probe-specific variable `passwordfile'. See
     Smokeping::probes::passwordchecker(3pm) for the format of this file (sum-
     mary: colon-separated triplets of the form `<host>:<username>:<password>')

     The RADIUS protocol requires a shared secret between the server and the
     client.  This secret can be specified either (in order of precedence, with
     the latter overriding the former) in the probe-specific variable `secret',
     in an external file or in the target-specific variable `secret'.  This ex-
     ternal file is located by the probe-specific variable `secretfile', and it
     should contain whitespace-separated pairs of the form `<host> <secret>'.
     Comments and blank lines are OK.

     If the optional probe-specific variable `nas_ip_address' is specified, its
     value is inserted into the authentication requests as the `NAS-IP-Address'
     RADIUS attribute.

     The probe tries to be nice to the server and does not send authentication
     requests more frequently than once every X seconds, where X is the value of
     the target-specific "min_interval" variable (1 by default).

VARIABLES
     Supported probe-specific variables:

     forks
	 Run this many concurrent processes at maximum

	 Example value: 5

	 Default value: 5

     offset
	 If you run many probes concurrently you may want to prevent them from
	 hitting your network all at the same time. Using the probe-specific
	 offset parameter you can change the point in time when each probe will
	 be run. Offset is specified in % of total interval, or alternatively as
	 'random', and the offset from the 'General' section is used if nothing
	 is specified here. Note that this does NOT influence the rrds itself,
	 it is just a matter of when data acquisition is initiated.  (This vari-
	 able is only applicable if the variable 'concurrentprobes' is set in
	 the 'General' section.)

	 Example value: 50%

     passwordfile
	 Location of the file containing usernames and passwords.

	 Example value: /some/place/secret

     secretfile
	 A file containing the RADIUS shared secrets for the targets. It should
	 contain whitespace-separated pairs of the form `<host> <secret>'. Com-
	 ments and blank lines are OK.

	 Example value: /another/place/secret

     stepDuration of the base interval that this probe should use, if different
	 from the one specified in the 'Database' section. Note that the step in
	 the RRD files is fixed when they are originally generated, and if you
	 change the step parameter afterwards, you'll have to delete the old RRD
	 files or somehow convert them. (This variable is only applicable if the
	 variable 'concurrentprobes' is set in the 'General' section.)

	 Example value: 300

     Supported target-specific variables:

     /^influx_.+/
	 This is a tag that will be sent to influxdb and has no impact on the
	 probe measurement. The tag name will be sent without the "influx_" pre-
	 fix, which will be replaced with "tag_" instead. Tags can be used for
	 filtering.

	 Example value: influx_location = In the basement

     allowreject
	 Treat "reject" responses as OK

	 Example value: true

     mininterval
	 The minimum interval between each authentication request sent, in (pos-
	 sibly fractional) seconds.

	 Default value: 1

     nas_ip_address
	 The NAS-IP-Address RADIUS attribute for the authentication requests.
	 Not needed everywhere.

	 Example value: 10.1.2.3

     password
	 The password for the user, if not present in the password file.

	 Example value: test-password

     pings
	 How many pings should be sent to each target, if different from the
	 global value specified in the Database section. Note that the number of
	 pings in the RRD files is fixed when they are originally generated, and
	 if you change this parameter afterwards, you'll have to delete the old
	 RRD files or somehow convert them.

	 Example value: 5

     portThe RADIUS port to be used

	 Example value: 1645

     secret
	 The RADIUS shared secret for the target, if not present in the secrets
	 file.

	 Example value: test-secret

     timeout
	 Timeout in seconds for the RADIUS queries.

	 Default value: 5

     username
	 The username to be tested.

	 Example value: test-user

	 This setting is mandatory.