Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
autogen(1)			  User Commands 		      autogen(1)

NAME
     autogen - The Automated Program Generator

SYNOPSIS
     autogen [-flags] [-flag [value]] [--option-name[[=| ]value]] [ <def-file> ]

     AutoGen creates text files from templates using external definitions.

DESCRIPTION
     AutoGen  is  designed  for generating program files that contain repetitive
     text with varied substitutions.  The goal is to simplify the maintenance of
     programs that contain large amounts of repetitious  text.	 This  is  espe-
     cially  valuable if there are several blocks of such text that must be kept
     synchronized.

     One common example is the problem of maintaining the code required for pro-
     cessing program options.  Processing options requires  a  minimum	of  four
     different	constructs  be	kept in proper order in different places in your
     program.  You need at least: The flag character in the flag string, code to
     process the flag when it is encountered, a global state  variable	or  two,
     and  a  line  in the usage text.  You will need more things besides this if
     you choose to implement long option names, configuration  file  processing,
     environment variables and so on.

     All  of  this  can be done mechanically; with the proper templates and this
     program.

OPTIONS
   The following options select definitions, templates and scheme  functions  to
     use
     -L dir, --templ-dirs=dir Search for templates in DIR.  This option may ap-
     pear an unlimited number of times.

     Add a directory to the list of directories autogen searches when opening a
     template, either as the primary template or an included one.  The last en-
     try has the highest priority in the search list.  That is to say, they are
     searched in reverse order.

     -T  tpl-file,  --override-tpl=tpl-file Use TPL-FILE for the template.  This
     option may not be preset with environment variables  or  in  initialization
     (rc) files.

     Definition  files	specify  the  standard	template that is to be expanded.
     This option will override that name and expand a different template.

     --definitions=file,  --no-definitions  Read  definitions  from  FILE.   The
     no-definitions form will disable the option.  This option is enabled by de-
     fault.  This option may not be preset with environment variables or in ini-
     tialization (rc) files.

     Use this argument to specify the input definitions file with a command line
     option.   If  you	do not specify this option, then there must be a command
     line argument that specifies the file, even if only to specify stdin with a
     hyphen (-).  Specify, --no-definitions when you wish to process a	template
     without any active AutoGen definitions.

     --shell=shell name or path name of shell to use.

     By  default,  when AutoGen is built, the configuration is probed for a rea-
     sonable Bourne-like shell to use for shell script processing.  If a partic-
     ular template needs an alternate shell, it must be specified with this  op-
     tion  on  the  command line, with an environment variable (SHELL) or in the
     configuration/initialization file.

     -m, --no-fmemopen Do not use in-mem streams.

     If the local C library  supports  "fopencookie(3GNU)",  or  "funopen(3BSD)"
     then AutoGen prefers to use in-memory stream buffer opens instead of anony-
     mous  files.   This  may lead to problems if there is a shortage of virtual
     memory.  If, for a particular application, you  run  out  of  memory,  then
     specify  this  option.   This is unlikely in a modern 64-bit virtual memory
     environment.

     On platforms without these functions, the option is accepted  but	ignored.
     fmemopen(POSIX) is not adequate because its string buffer is not reallocat-
     able.   open_memstream(POSIX)  is	also  not adequate because the stream is
     only opened for output.  AutoGen needs a reallocatable buffer available for
     both reading and writing.

     --equate=char-list characters considered equivalent.  The default char-list
     for this option is:
	  _-^

     This option will alter the list of characters considered  equivalent.   The
     default  are  the	three characters, "_-^".  (The last is conventional on a
     Tandem/HP-NonStop, and I used to do a lot of work on Tandems.)

	The following options modify how output is handled

     -b name, --base-name=name Specify NAME as the base name for output.  This
     option may not be preset with environment variables or in initialization
     (rc) files.

     A template may specify the exact name of the output file.	Normally, it
     does not.	Instead, the name is composed of the base name of the defini-
     tions file with suffixes appended.  This option will override the base name
     derived from the definitions file name.  This is required if there is no
     definitions file and advisable if definitions are being read from stdin.
     If the definitions are being read from standard in, the base name defaults
     to stdin.	Any leading directory components in the name will be silently
     removed.  If you wish the output file to appear in a particular directory,
     it is recommended that you "cd" into that directory first, or use directory
     names in the format specification for the output suffix lists, see: pseudo
     macro.

     --source-time, --no-source-time  set  mod	times  to  latest  source.   The
     no-source-time form will disable the option.

     If  you stamp your output files with the DNE macro output, then your output
     files will always be different, even if the content has not really changed.
     If you use this option, then the modification time of the output files will
     change only if the input files change.   This  will  help	reduce	unneeded
     builds.

     --writable,   --not-writable  Allow  output  files  to  be  writable.   The
     not-writable form will disable the option.

     This option will leave output files writable.  Normally, output  files  are
     read-only.

	The following options are often useful while debugging new templates
	    They  specify  limits  that  prevent the template from taking overly
	    long or producing more output than expected.

     --loop-limit=lim Limit on increment loops.  This option takes an integer
     number as its argument.  The value of lim is constrained to being:
	 exactly -1, or
	 in the range  1 through 0x1000000
     The default lim for this option is:
	  256

     This option prevents runaway loops.  For example, if you accidentally spec-
     ify, "FOR x (for-from 1) (for-to -1) (for-by 1)", it will take a long time
     to finish.  If you do have more than 256 entries in tables, you will need
     to specify a new limit with this option.

     -t seconds, --timeout=seconds Limit server  shell	operations  to	SECONDS.
     This  option takes an integer number as its argument.  The value of seconds
     is constrained to being:
	 in the range  0 through 3600

     AutoGen works with a shell server process.  Most normal commands will com-
     plete in less than 10 seconds.  If, however, your commands need more time
     than this, use this option.

     The valid range is 0 to 3600 seconds (1 hour).  Zero will disable the
     server time limit.

     --trace=level tracing level of detail.  This option takes a keyword as  its
     argument.	 The  argument	sets  an enumeration value that can be tested by
     comparing them against the option value macro.  The available keywords are:
	 nothing       debug-message server-shell
	 templates     block-macros  expressions
	 everything
	 or their numeric equivalent.

     The default level for this option is:
	  nothing

     This option will cause AutoGen to display a trace of its template process-
     ing.  There are six levels, each level including messages from the previous
     levels:

     nothing Does no tracing at all (default)

     debug-message Print messages from the "DEBUG" AutoGen macro (see: DEBUG).

     server-shell Traces all input and output to the server shell.  This in-
     cludes a shell "independent" initialization script about 30 lines long.
     Its output is discarded and not inserted into any template.

     templates Traces the invocation of DEFINEd macros and INCLUDEs

     block-macros Traces all block macros.  The above, plus IF, FOR, CASE and
     WHILE.

     expressions Displays the results of expression evaluations.

     everything Displays the invocation of every AutoGen macro, even TEXT macros
     (i.e. the text outside of macro quotes).  Additionally, if you rebuild the
     ``expr.ini'' file with debugging enabled, then all calls to AutoGen defined
     scheme functions will also get logged:
	 cd ${top_builddir}/agen5
	 DEBUG_ENABLED=true bash bootstrap.dir expr.ini
	 make CFLAGS='-g -DDEBUG_ENABLED=1'

     Be aware that you cannot rebuild this source in this way without first hav-
     ing installed the autogen executable in your search path.	Because of this,
     "expr.ini" is in the distributed source list, and not in the dependencies.

     --trace-out=file tracing output file or filter.

     The output specified may be a file name, a file that is appended to, or, if
     the option argument begins with the pipe operator (|), a command that  will
     receive  the  tracing  output  as	standard in.  For example, --traceout='|
     less' will run the trace output through the less program.	Appending  to  a
     file  is specified by preceding the file name with two greater-than charac-
     ters (>>).

     --show-defs Show the definition tree.  This option may not be  preset  with
     environment variables or in initialization (rc) files.

     This will print out the complete definition tree before processing the tem-
     plate.

     --used-defines  Show  the	definitions used.  This option may not be preset
     with environment variables or in initialization (rc) files.

     This will print out the names of definition values searched for during  the
     processing  of  the  template, whether actually found or not.  There may be
     other referenced definitions in a template in portions of the template  not
     evaluated.  Some of the names listed may be computed names and others Auto-
     Gen  macro arguments.  This is not a means for producing a definitive, all-
     encompassing list of all and only the values used from a  definition  file.
     This is intended as an aid to template documentation only.

     -C, --core Leave a core dump on a failure exit.

     Many  systems  default  to  a zero sized core limit.  If the system has the
     sys/resource.h header and if this option is supplied, then in  the  failure
     exit  path, autogen will attempt to set the soft core limit to whatever the
     hard core limit is.  If that does not  work,  then  an  administrator  must
     raise  the  hard  core  size  limit.  in the definitions files and template
     files" They specify which outputs and parts of outputs to produce.

     -s suffix, --skip-suffix=suffix Skip the file with this SUFFIX.   This  op-
     tion  may appear an unlimited number of times.  This option may not be pre-
     set with environment variables or in initialization (rc) files.   This  op-
     tion  must not appear in combination with any of the following options: se-
     lect-suffix.

     Occasionally, it may not be desirable to produce all of  the  output  files
     specified	in the template.  (For example, only the .h header file, but not
     the .c program text.)  To do this specify --skip-suffix=c	on  the  command
     line.

     -o  suffix, --select-suffix=suffix specify this output suffix.  This option
     may appear an unlimited number of times.  This option  may  not  be  preset
     with environment variables or in initialization (rc) files.

     If  you wish to override the suffix specifications in the template, you can
     use one or more copies of this option.  See the suffix specification in the
     @ref{pseudo macro} section of the info doc.

     -D value, --define=value name to add to definition list.  This  option  may
     appear an unlimited number of times.

     The AutoGen define names are used for the following purposes:

     Sections  of the AutoGen definitions may be enabled or disabled by using C-
     style #ifdef and #ifndef directives.

     When defining a value for a name, you may specify the index for a	particu-
     lar  value.   That index may be a literal value, a define option or a value
     #define-d in the definitions themselves.

     The name of a file may be prefixed with $NAME/.  The $NAME part of the name
     string will be replaced with the define-d value for NAME.

     When AutoGen is finished loading the definitions, the  defined  values  are
     exported to the environment with, putenv(3).  These values can then be used
     in  shell	scripts  with  ${NAME@} references and in templates with (getenv
     "NAME").

     While processing a template, you may specify an index to  retrieve  a  spe-
     cific value.  That index may also be a define-d value.

     It  is  entirely equivalent to place this name in the exported environment.
     Internally, that is what AutoGen actually does with this option.

     -U name-pat, --undefine=name-pat definition list removal pattern.	This op-
     tion may appear an unlimited number of times.  This option may not be  pre-
     set with environment variables or in initialization (rc) files.

     Similar to 'C', AutoGen uses #ifdef/#ifndef preprocessing directives.  This
     option will cause the matching names to be removed from the list of defined
     values.

	This option is used to automate dependency tracking

     -M type, --make-dep [type] emit make dependency file.  This option may ap-
     pear an unlimited number of times.  This option may not be preset with en-
     vironment variables or in initialization (rc) files.

     This option behaves fairly closely to the way the -M series of options work
     with the gcc compiler, except that instead of just emitting the predecessor
     dependencies, this also emits the successor dependencies (output target
     files).  By default, the output dependency information will be placed in
     <base-name>.d, but may also be specified with -MF<file>.  The time stamp on
     this file will be manipulated so that it will be one second older than the
     oldest primary output file.

     The target in this dependency file will normally be the dependency file
     name, but may also be overridden with -MT<targ-name>.  AutoGen will not al-
     ter the contents of that file, but it may create it and it will adjust the
     modification time to match the start time.

     NB: these second letters are part of the option argument, so -MF <file>
     must have the space character quoted or omitted, and -M "F <file>" is ac-
     ceptable because the F is part of the option argument.

     -M may be followed by any of the letters M, F, P, T, Q, D, or G.  However,
     only F, Q, T and P are meaningful.  All but F have somewhat different mean-
     ings.  -MT<name> is interpreted as meaning <name> is a sentinel file that
     will depend on all inputs (templates and definition files) and all the out-
     put files will depend on this sentinel file.  It is suitable for use as a
     real make target.	Q is treated identically to T, except dollar characters
     ('$') are doubled.  P causes a special clean (clobber) phoney rule to be
     inserted into the make file fragment.  An empty rule is always created for
     building the list of targets.

     This is the recommended usage:
	   -MFwhatever-you-like.dep -MTyour-sentinel-file -MP
     and then in your Makefile, make the autogen rule:
	   -include whatever-you-like.dep
	   clean_targets += clean-your-sentinel-file
	 .sp
	   your-sentinel-file:
	       autogen -MT$@@ -MF$*.d .....
	 .sp
	   local-clean :
	       rm -f $(clean_targets)

     The modification time on the dependency file is adjusted to be one second
     before the earliest time stamp of any other output file.  Consequently, it
     is suitable for use as the sentinel file testifying to the fact the program
     was successfully run.  (-include is the GNU make way of specifying "include
     it if it exists".	Your make must support that feature or your bootstrap
     process must create the file.)

     All of this may also be specified using the DEPENDENCIES_OUTPUT or AUTO-
     GEN_MAKE_DEP environment variables.  If defined, dependency information
     will be output.  If defined with white space free text that is something
     other than true, false, yes, no, 0 or 1, then the string is taken to be an
     output file name.	If it contains a string of white space characters, the
     first token is as above and the second token is taken to be the target
     (sentinel) file as -MT in the paragraphs above.  DEPENDENCIES_OUTPUT will
     be ignored if there are multiple sequences of white space characters or if
     its contents are, specifically, false, no or 0.

	help, version, option and error handling

     --no-abort Do not abort on errors.

     By default, AutoGen will abort on an error leaving behind a core image.
     That is sometimes inconvenient. If present on the command line or in the
     environment, AutoGen will call exit(1) instead of abort().

     -?, --help Display usage information and exit.

     -!, --more-help Pass the extended usage information through a pager.

     -> [cfgfile], --save-opts [=cfgfile] Save the option state to cfgfile.  The
     default  is  the  last configuration file listed in the OPTION PRESETS sec-
     tion, below.  The command will exit after updating the config file.

     -< cfgfile, --load-opts=cfgfile, --no-load-opts Load options from	cfgfile.
     The  no-load-opts	form  will  disable the loading of earlier config/rc/ini
     files.  --no-load-opts is handled early, out of order.

     -v [{v|c|n --version [{v|c|n}]}] Output version of program and  exit.   The
     default  mode  is `v', a simple version.  The `c' mode will print copyright
     information and `n' will print the full copyright notice.

     OPTION PRESETS
	    Any option that is not marked as not presettable may be  preset
	    by	loading  values from configuration ("RC" or ".INI") file(s)
	    and values from environment variables named:
	      AUTOGEN_<option-name> or AUTOGEN
	    The environmental presets take precedence (are processed  later
	    than)  the	configuration files.  The homerc files are "$HOME",
	    and ".".  If any of these are directories, then the file .auto-
	    genrc is searched for within those directories.

ENVIRONMENT
     See OPTION PRESETS for configuration environment variables.

FILES
     See OPTION PRESETS for configuration files.

EXAMPLES
     Here is how the man page is produced:
	 autogen -Tagman-cmd.tpl -MFman-dep -MTstamp-man opts.def

     This command produced this man page from the AutoGen option definition
     file.  It overrides the template specified in opts.def  (normally	op-
     tions.tpl)  and uses agman-cmd.tpl.  It also sets the make file depen-
     dency output to man-dep and the sentinel file  (time  stamp  file)  to
     man-stamp.   The  base  of  the  file name is derived from the defined
     prog-name.

     The texi invocation document is produced via:
	 autogen -Tagtexi-cmd.tpl -MFtexi-dep -MTtexi-stamp opts.def

EXIT STATUS
     One of the following exit values will be returned:

     0	(EXIT_SUCCESS) Successful program execution.

     1	(EXIT_OPTION_ERROR) The command options were misconfigured.

     2	(EXIT_BAD_TEMPLATE) An error was encountered  processing  the  tem-
     plate.

     3	(EXIT_BAD_DEFINITIONS) The definitions could not be deciphered.

     4	(EXIT_LOAD_ERROR) An error was encountered during the load phase.

     5	(EXIT_FS_ERROR) a file system error stopped the program.

     6	(EXIT_NO_MEM) Insufficient memory to operate.

     128   (EXIT_SIGNAL)  autogen exited due to catching a signal.  If your
     template includes string formatting, a number argument to a "%s"  for-
     matting element will trigger a segmentation fault.  Autogen will catch
     the  seg  fault signal and exit with AUTOGEN_EXIT_SIGNAL(5).  Alterna-
     tively, AutoGen may have been interrupted with a kill(2) signal.  Sub-
     tract 128 from the actual exit code to detect the signal number.

     66  (EX_NOINPUT) A specified configuration file could not be loaded.

     70  (EX_SOFTWARE) libopts had an internal operational  error.   Please
     report it to autogen-users@lists.sourceforge.net.	Thank you.

     AUTHORS
	    Bruce Korb

COPYRIGHT
     Copyright	(C)  1992-2018	Bruce  Korb all rights reserved.  This
     program is released under the terms of the GNU General Public Li-
     cense, version 3 or later.

BUGS
     Please send bug reports to: autogen-users@lists.sourceforge.net

NOTES
     This manual page was AutoGen-erated from the autogen option defi-
     nitions.

GNU AutoGen (5.18.16)		   26 Aug 2018			      autogen(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=autogen&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help