Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
COLLECTD-THRESHOLD(5)		    collectd		   COLLECTD-THRESHOLD(5)

NAME
     collectd-threshold - Documentation of collectd's Threshold plugin

SYNOPSIS
      LoadPlugin "threshold"
      <Plugin "threshold">
	<Type "foo">
	  WarningMin	0.00
	  WarningMax 1000.00
	  FailureMin	0.00
	  FailureMax 1200.00
	  Invert false
	  Instance "bar"
	</Type>
      </Plugin>

DESCRIPTION
     Starting with version 4.3.0 collectd has support for monitoring. By that we
     mean  that  the values are not only stored or sent somewhere, but that they
     are judged and, if a problem is recognized, acted upon. The only action the
     Threshold plugin takes itself is to generate and dispatch	a  notification.
     Other plugins can register to receive notifications and perform appropriate
     further actions.

     Since  systems and what you expect them to do differ a lot, you can config-
     ure thresholds for your values freely. This gives you a lot of  flexibility
     but also a lot of responsibility.

     Every  time  a  value  is	out of range, a notification is dispatched. This
     means that the idle percentage of your CPU needs to be less then  the  con-
     figured  threshold only once for a notification to be generated. There's no
     such thing as a moving average or similar - at least not now.

     Also, all values that match a threshold are considered to	be  relevant  or
     "interesting".  As a consequence collectd will issue a notification if they
     are not received for Timeout iterations. The Timeout  configuration  option
     is explained in section "GLOBAL OPTIONS" in collectd.conf(5). If, for exam-
     ple,  Timeout is set to "2" (the default) and some hosts sends its CPU sta-
     tistics to the server every 60 seconds, a notification will  be  dispatched
     after about 120 seconds. It may take a little longer because the timeout is
     checked only once each Interval on the server.

     When  a value comes within range again or is received after it was missing,
     an "OKAY-notification" is dispatched.

CONFIGURATION
     Here is a configuration example to get you started. Read below for more in-
     formation.

      LoadPlugin "threshold"
      <Plugin "threshold">
	<Type "foo">
	  WarningMin	0.00
	  WarningMax 1000.00
	  FailureMin	0.00
	  FailureMax 1200.00
	  Invert false
	  Instance "bar"
	</Type>

	<Plugin "interface">
	  Instance "eth0"
	  <Type "if_octets">
	    FailureMax 10000000
	    DataSource "rx"
	  </Type>
	</Plugin>

	<Host "hostname">
	  <Type "cpu">
	    Instance "idle"
	    FailureMin 10
	  </Type>

	  <Plugin "memory">
	    <Type "memory">
	      Instance "cached"
	      WarningMin 100000000
	    </Type>
	  </Plugin>

	  <Type "load">
	     DataSource "midterm"
	     FailureMax 4
	     Hits 3
	     Hysteresis 3
	  </Type>
	</Host>
      </Plugin>

     There are basically two types  of	configuration  statements:  The  "Host",
     "Plugin",	and  "Type" blocks select the value for which a threshold should
     be configured. The "Plugin" and "Type" blocks may be specified further  us-
     ing the "Instance" option. You can combine the block by nesting the blocks,
     though  they must be nested in the above order, i.e. "Host" may contain ei-
     ther "Plugin" and "Type" blocks, "Plugin" may only  contain  "Type"  blocks
     and  "Type"  may  not contain other blocks. If multiple blocks apply to the
     same value the most specific block is used.

     The other statements specify the threshold to configure. They must  be  in-
     cluded  in  a  "Type"  block. Currently the following statements are recog-
     nized:

     FailureMax Value
     WarningMax Value
	 Sets the upper bound of acceptable values. If unset defaults  to  posi-
	 tive  infinity. If a value is greater than FailureMax a FAILURE notifi-
	 cation will be created. If the value is  greater  than  WarningMax  but
	 less  than (or equal to) FailureMax a WARNING notification will be cre-
	 ated.

     FailureMin Value
     WarningMin Value
	 Sets the lower bound of acceptable values. If unset defaults  to  nega-
	 tive  infinity.  If a value is less than FailureMin a FAILURE notifica-
	 tion will be created. If the value is less than WarningMin but  greater
	 than (or equal to) FailureMin a WARNING notification will be created.

     DataSource DSName
	 Some  data  sets have more than one "data source". Interesting examples
	 are the "if_octets" data set, which has received ("rx") and sent ("tx")
	 bytes and the "disk_ops" data set, which holds "read" and "write" oper-
	 ations. The system load data set, "load", even has three data	sources:
	 "shortterm", "midterm", and "longterm".

	 Normally,  all data sources are checked against a configured threshold.
	 If this is undesirable, or if you want to specify different limits  for
	 each data source, you can use the DataSource option to have a threshold
	 apply only to one data source.

     Invert true|false
	 If  set to true the range of acceptable values is inverted, i.e. values
	 between FailureMin and FailureMax (WarningMin and WarningMax)	are  not
	 okay. Defaults to false.

     Persist true|false
	 Sets  how often notifications are generated. If set to true one notifi-
	 cation will be generated for each value that is out of  the  acceptable
	 range. If set to false (the default) then a notification is only gener-
	 ated if a value is out of range but the previous value was okay.

	 This  applies	to  missing  values,  too: If set to true a notification
	 about a missing value is generated once every Interval seconds. If  set
	 to  false  only  one such notification is generated until the value ap-
	 pears again.

     PersistOK true|false
	 Sets how OKAY notifications act. If set to true one  notification  will
	 be  generated for each value that is in the acceptable range. If set to
	 false (the default) then a notification is only generated if a value is
	 in range but the previous value was not.

     Percentage true|false
	 If set to true, the minimum and maximum values given are interpreted as
	 percentage value, relative to the other data sources. This  is  helpful
	 for  example  for  the "df" type, where you may want to issue a warning
	 when less than 5 % of the total space is available. Defaults to false.

     Hits Value
	 Sets the number of occurrences which the threshold must be  raised  be-
	 fore to dispatch any notification or, in other words, the number of In-
	 tervals  that the threshold must be match before dispatch any notifica-
	 tion.

     Hysteresis Value
	 Sets the hysteresis value for threshold. The hysteresis is a method  to
	 prevent  flapping between states, until a new received value for a pre-
	 viously matched threshold down below the threshold condition  (Warning-
	 Max,  FailureMin  or  everything  else) minus the hysteresis value, the
	 failure (respectively warning) state will be keep.

     Interesting true|false
	 If set to true (the default), a notification  with  severity  "FAILURE"
	 will  be  created  when  a matching value list is no longer updated and
	 purged from the internal cache. When this happens depends on the inter-
	 val of the value list and the global Timeout setting. See the	Interval
	 and  Timeout settings in collectd.conf(5) for details. If set to false,
	 this event will be ignored.

SEE ALSO
     collectd(1), collectd.conf(5)

AUTHOR
     Florian Forster <octo at collectd.org>

5.11.0.94.g41b1e33		   2020-07-20		   COLLECTD-THRESHOLD(5)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=collectd-threshold&sektion=5&manpath=FreeBSD+Ports+15.1.quarterly>

home | help