NAME
     flowcap - Capture network flow data and write it to temporary files

SYNOPSIS
       flowcap --destination-directory=DIR_PATH
	     --sensor-configuration=FILENAME [--probes=NAME[,NAME...]]
	     --max-file-size=SIZE [--fc-version=NUM]
	     [--timeout=TIMEOUT] [--clock-time[=OFFSET]]
	     [--freespace-minimum=SIZE] [--space-maximum-percent=NUM]
	     [--compression-method=COMP_METHOD]
	     { --log-destination=DESTINATION
	       | --log-pathname=FILE_PATH
	       | --log-directory=DIR_PATH [--log-basename=LOG_BASENAME]
		 [--log-post-rotate=COMMAND] }
	     [--log-level=LEVEL] [--log-sysfacility=NUMBER]
	     [--pidfile=FILE_PATH] [--no-chdir] [--no-daemon]

     Help options:

       flowcap --sensor-configuration=FILE_PATH
	     { --verify-sensor-config | --verify-sensor-config=VERBOSE }

       flowcap --help

       flowcap --version

DESCRIPTION
     flowcap is a daemon that collects records from routers, flow meters, and
     devices that produce network flow data.  The records are written in the
     SiLK Flow record format to temporary files on disk.  flowcap may collect
     NetFlow records (versions 5 or 9), IPFIX records (Internet Protocol Flow
     Information eXport) such as those generated by yaf(1), or sFlow records.

     The SiLK Flow files produced by flowcap are meant to be used only for tem-
     porary storage.  For longer-term storage, the records should processed by
     the rwflowpack(8) daemon which assigns values to each record depending on
     where it was collected and writes the record to an hourly file that is
     stored in a directory tree.

     As flowcap receives flow records, it stores them in files in the location
     specified by the --destination-directory switch.  These files are closed on
     quantum boundaries, with one file per flow source per quantum.  A quantum
     is either the amount of time represented by the --timeout switch or the
     file size represented by the --max-file-size switch, whichever is reached
     first.

     To transfer the files to rwflowpack, flowcap works in tandem with the
     rwsender(8) program.  rwsender polls the storage directory and sends the
     files it finds there to an rwreceiver(8) process for processing by rwflow-
     pack.

     flowcap produces files that are named PROBE_YYYYMMDDhhmmss.XXXXXX, where
     PROBE is the name of the probe, YYYY is the current year, MM is the current
     month, DD is the current day, hh is the current hour, mm is the current
     minute, ss is the current second, and XXXXXX is a random six-character
     string.

OPTIONS
     Option names may be abbreviated if the abbreviation is unique or is an ex-
     act match for an option.  A parameter to an option may be specified as
     --arg=param or --arg param, though the first form is required for options
     that take optional parameters.

     For the following options, a SIZE may be given as an ordinary integer, or
     as a real number followed by a suffix "K", "M", "G", or "T", which repre-
     sents the numerical value multiplied by 1,024 (kilo), 1,048,576 (mega),
     1,073,741,824 (giga), and 1,099,511,627,776 (tera), respectively.	For ex-
     ample, 1.5K represents 1,536 bytes, or one and one-half kilobytes.

   General Configuration Switches
     --destination-directory=DIR_PATH
	 Store aggregated packed flow files in this directory for processing by
	 rwsender.  DIR_PATH must be a complete directory path.  This switch is
	 required.

     --sensor-configuration=FILENAME
	 Give the path to the configuration file that flowcap consults to deter-
	 mine how to collect flow records.  The complete syntax of the configu-
	 ration file is described in the sensor.conf(5) manual page; see also
	 the SiLK Installation Handbook.  This switch is required.

     --probes=NAME[,NAME...]
	 Choose which of the probes described in the sensor configuration file
	 will be used by flowcap.  The default is to use all of the probes de-
	 fined in the configuration file.  This switch instructs flowcap to only
	 use the specifically named probes.

     --max-file-size=SIZE
	 Set the approximate maximum size of flowcap files to SIZE bytes.  If a
	 flowcap file exceeds SIZE bytes, it is closed and a new file will be
	 created and used.  In addition, before opening an output file, flowcap
	 ensures there are SIZE bytes of free space available, and exits if
	 there is not.	This switch is required.

     --timeout=TIMEOUT
	 Set the maximum duration that a flowcap output file remains open to
	 TIMEOUT seconds.  When the --clock-time switch is given, the first du-
	 ration may be less than TIMEOUT seconds.  If the --timeout switch is
	 not specified, flowcap uses a default of 60 seconds.

     --clock-time[=OFFSET]
	 Force flowcap to close its files at predictable times.  When this
	 switch is provided, flowcap closes its output files at OFFSET seconds
	 after midnight (UTC of the current day) and at every TIMEOUT seconds
	 thereafter.  The default value of OFFSET is 0.  For example, --time-
	 out=900 --clock-time=300 causes flowcap to close its output files at
	 the 05, 20, 35, and 50 minute points in each hour.  Even with this
	 switch, files are still be closed if they exceed the size specified by
	 --max-file-size.

     --fc-version=NUM
	 Choose the record version for the files of IPv4 flow records that flow-
	 cap produces.	Valid values are 2, 3, 4, and 5, and the default is 5.
	 This switch is ignored for probes that support IPv6 addresses.

     --freespace-minimum=SIZE
	 Set the minimum free space to maintain on the file system where the
	 --destination-directory is located.  By default, flowcap assumes that
	 it has full rein over the file system on which it writes its files.
	 The default is to leave 1GB of free space.  If flowcap fills this
	 space, it exits.  Flows arriving during this time will be lost.  See
	 also --space-maximum-percent.

     --space-maximum-percent=NUM
	 Use no more than this percentage of the file system containing the
	 --destination-directory.  The default is to use no more than 98% of the
	 file system.  If flowcap fills this space, it exits.  See also --free-
	 space-minimum.

     --compression-method=COMP_METHOD
	 Specify the compression library to use when writing output files.  When
	 no compression method is specified, flowcap files are compressed using
	 the "best" method, regardless of the default chosen when SiLK was com-
	 piled.  The valid values for COMP_METHOD are determined by which exter-
	 nal libraries were found when SiLK was compiled.  To see the available
	 compression methods and the default method, use the --help or --version
	 switch. SiLK can support the following COMP_METHOD values when the re-
	 quired libraries are available.

	 noneDo not compress the output using an external library.

	 zlibUse the zlib(3) library for compressing the output.  Using zlib
	     produces the smallest output files at the cost of speed.

	 lzo1x
	     Use the lzo1x algorithm from the LZO real time compression library
	     for compression.  This compression provides good compression with
	     less memory and CPU overhead.

	 snappy
	     Use the snappy library for compression.  This compression provides
	     good compression with less memory and CPU overhead.  Since SiLK
	     3.13.0.

	 bestUse lzo1x if available, otherwise use snappy if available, other-
	     wise use zlib if available.

     --verify-sensor-config
     --verify-sensor-config=VERBOSE
	 Verify that the syntax of the sensor configuration file is correct and
	 then exit flowcap.  If the file is incorrect or if it does not define
	 any probes, an error message is printed and flowcap exits abnormally.
	 If the file is correct and no argument is provided to the --verify-sen-
	 sor-config switch, flowcap simply exits with status 0.  If an argument
	 (other than the empty string and 0) is provided to the switch, the
	 names of the probes found in the sensor configuration file are printed
	 to the standard output, and then flowcap exits.

     --help
	 Print the available options and exit.

     --version
	 Print the version number and information about how SiLK was configured,
	 then exit the application.

   Logging and Daemon Configuration Switches
     The switches in this section determine the type of log messages that flow-
     cap generates and where those messages are written.

     One of the following switches are required:

     --log-destination=DESTINATION
	 Specify the destination where logging messages are written.  When DES-
	 TINATION begins with a slash "/", it is treated as a file system path
	 and all log messages are written to that file; there is no log rota-
	 tion.	When DESTINATION does not begin with "/", it must be one of the
	 following strings:

	 "none"
	     Messages are not written anywhere.

	 "stdout"
	     Messages are written to the standard output.

	 "stderr"
	     Messages are written to the standard error.

	 "syslog"
	     Messages are written using the syslog(3) facility.

	 "both"
	     Messages are written to the syslog facility and to the standard er-
	     ror (this option is not available on all platforms).

     --log-directory=DIR_PATH
	 Use DIR_PATH as the directory to which the log files are written;
	 DIR_PATH must be a complete directory path.  The log files have the
	 form

	  DIR_PATH/LOG_BASENAME-YYYYMMDD.log

	 where YYYYMMDD is the current date and LOG_BASENAME is the application
	 name or the value passed to the --log-basename switch when provided.
	 The log files are rotated: At midnight local time, a new log is opened,
	 the previous file is closed, and the command specified by
	 --log-post-rotate is invoked on the previous day's log file.  (Old log
	 files are not removed by flowcap; the administrator should use another
	 tool to remove them.)	When this switch is provided, a process-ID file
	 (PID) is also written in this directory unless the --pidfile switch is
	 provided.

     --log-pathname=FILE_PATH
	 Use FILE_PATH as the complete path to the log file.  The log file is
	 not rotated.

     The following switches are optional:

     --log-level=LEVEL
	 Set the severity of messages that are logged.	The levels from most se-
	 vere to least are: "emerg", "alert", "crit", "err", "warning", "no-
	 tice", "info", "debug".  The default is "info".

     --log-sysfacility=NUMBER
	 Set the facility that syslog(3) uses for logging messages.  This switch
	 takes a number as an argument.  The default is a value that corresponds
	 to "LOG_USER" on the system where flowcap is running.	This switch pro-
	 duces an error unless --log-destination=syslog is specified.

     --log-basename=LOG_BASENAME
	 Use LOG_BASENAME in place of the application name in the name of log
	 files in the log directory.  See the description of the --log-directory
	 switch.  This switch does not affect the name of the process-ID file.

     --log-post-rotate=COMMAND
	 Run COMMAND on the previous day's log file after log rotation.  When
	 this switch is not specified, the previous day's log file is compressed
	 with gzip(1).	When the switch is specified and COMMAND is the empty
	 string, no action is taken on the log file.  Each occurrence of the
	 string %s in COMMAND is replaced with the full path to the log file,
	 and each occurrence of "%%" is replaced with "%".  If any other charac-
	 ter follows "%", flowcap exits with an error.	Specifying this switch
	 without also using --log-directory is an error.

     --pidfile=FILE_PATH
	 Set the complete path to the file in which flowcap writes its process
	 ID (PID) when it is running as a daemon.  No PID file is written when
	 --no-daemon is given.	When this switch is not present, no PID file is
	 written unless the --log-directory switch is specified, in which case
	 the PID is written to LOGPATH/flowcap.pid.

     --no-chdir
	 Do not change directory to the root directory.  When flowcap becomes a
	 daemon process, it changes its current directory to the root directory
	 so as to avoid potentially running on a mounted file system.  Specify-
	 ing --no-chdir prevents this behavior, which may be useful during de-
	 bugging.  The application does not change its directory when --no-dae-
	 mon is given.

     --no-daemon
	 Force flowcap to run in the foreground---it does not become a daemon
	 process.  This may be useful during debugging.

ENVIRONMENT
     SILK_IPFIX_PRINT_TEMPLATES
	 When set to 1, flowcap writes messages to the log file describing each
	 IPFIX and NetFlow v9 template it receives.  This is equivalent to
	 adding "show-templates" to the "log-flags" setting for each probe in
	 the sensor.conf file.	See the sensor.conf(5) manual page for the for-
	 mat of these messages.  Since SiLK 3.8.2.

     SILK_LIBFIXBUF_SUPPRESS_WARNINGS
	 When set to 1, flowcap disables all warning messages generated by lib-
	 fixbuf.  These warning messages include out-of-sequence packets, data
	 records not having a corresponding template, record count discrepan-
	 cies, and issues decoding list elements.  Since SiLK 3.10.0.

FILES
     sensor.conf
	 The location of this file must be specified by the --sensor-configura-
	 tion switch.  This file specifies probe blocks that tell flowcap how to
	 capture data.	The syntax of this file is described in the sen-
	 sor.conf(5) manual page.

SEE ALSO
     sensor.conf(5), rwflowpack(8), rwsender(8), rwreceiver(8), silk(7), yaf(1),
     syslog(3), zlib(3), gzip(1), SiLK Installation Handbook

SiLK 3.22.2			   2026-08-27			      flowcap(8)