home | help
HEYU(1) 		     General Commands Manual			 HEYU(1)

NAME
     Heyu - a control program for the  X-10 CM11A serial interface

USAGE
     heyu [options] command [parameter(s)]

     Run  'heyu  help' for a description of the Heyu options and commands avail-
     able in the current version.

DESCRIPTION
     Heyu is a program for controlling an X-10 CM11A 2-Way  Computer  Interface.
     This  is  the  control device manufactured by X-10 (USA) Inc.  and found in
     their ActiveHome(TM) CK11A kit.  Equivalent (rebranded) devices  have  been
     sold as the IBM HD11A Home Director and the RCA HC60CRX Home Control Inter-
     face.  220 Volt versions of the CM11A are sold in Europe as variously named
     CM11x models (depending on AC plug style) and in the UK as the CM12U.

     The  CM11A can remotely control lights and appliances in your house by sig-
     naling over the AC house wiring.  It can store lists  of  X10  signals  and
     send  them at scheduled times.  It can respond to some X10 signals by send-
     ing out other X10 signals.  With Heyu, it can respond to X10 signals by ex-
     ecuting an arbitrary command or script selected by the user.

     Limited support is provided for the IBM HD16A, an earlier	version  of  the
     Home  Director without clock or battery backup and known as the CM10A - see
     special CM10A configuration instructions in the TTY  directive  section  of
     man page x10config(5).

     Heyu  supports an auxiliary input device on a second serial port for X10 RF
     signals.  Supported devices are the WGL W800RF32A, the X-10 MR26A, and  the
     RFXCOM  X10 RF Receivers. A network version of the RFXCOM receiver, RFXLAN,
     is also supported.

     The W800RF32A  is	manufactured  by  WGL  &  Associates  (http://www.wglde-
     signs.com).  It is available in both a 310 MHz version for operation in the
     USA and Canada and a 433.92 MHz version (W800RF32AE) for European and other
     countries.   It can receive signals from standard, entertainment, and secu-
     rity X10 transmitters.

     The X-10 MR26A is usually bundled with a univeral remote in  a  package  by
     X-10  but	is also available individually.  It can receive standard and en-
     tertainment X10 signals but not security X10 signals.

     The RFXCOM X10 receiver is supported in W800RF32 emulation mode and has the
     same capabilities.  It is a USB device but has a built-in FTDI  USB-to-Ser-
     ial  converter  and communication with it is the same as with a serial port
     (assuming your OS supports the FTDI chipset, as does Linux).

     Heyu also supports the X-10 CM17A	"Firecracker",	a  small  serial  dongle
     which  can  transmit  X10	commands via RF signals to a transceiver plugged
     into the power line.  The CM17A and CM11A coexist on the same serial port -
     no additional serial port is required.
     As far as can be determined there is no version of the CM17A  which  trans-
     mits at an RF frequency other than the 310 MHz used for X10 transceivers in
     North  America.  A compile option is provided to compile Heyu without CM17A
     support for users outside North America or those who simply have no  inter-
     est  in this device. (See the file "INSTALL" included in the Heyu distribu-
     tion directory.)

     Heyu depends on a configuration file to tell it on  what  serial  port  the
     CM11A is connected and to provide it with various other user options.  Heyu
     will not run without the configuration file.  See x10config(5) for more in-
     formation.   The  standard  pathnames Heyu assumes for this file are either
     $HOME/.heyu/x10config or /etc/heyu/x10.conf, in that order,  but  the  user
     can specify a non-standard pathname at the command line or with an environ-
     ment  variable.  (Operating systems other than Linux may store the configu-
     ration file in a different directory by default.)	The directory where Heyu
     finds the configuration file is Heyu's  "base"  directory.   Heyu	requires
     that this directory be writable.

     The CM11A connects to a computer via an RS232 serial port (or a USB-to-Ser-
     ial  adapter for newer systems without an RS232 serial port).  It can store
     about 128 events;	each event can turn on, turn off, or dim one or more X10
     modules.  The CM11A box has a battery backed clock which the  computer  can
     read.  The data is stored in an EEPROM.

     You  could  just  put  a  bunch  of Heyu commands in your crontab, but this
     doesn't work if your system is down for backups,  or  has	crashed,  or  if
     someone's tripped over the RS232 cable and unplugged it, and it clutters up
     the  crontab.   For  most	users,	it's much easier to upload a schedule of
     events into the CM11A's EEPROM.

     Special note: If you have chosen to locate the Heyu configuration file  un-
     der  your	home directory and then run Heyu commands in crontab, Heyu won't
     be able to automatically find the configuration file since it will be  run-
     ning  as user 'root'.  In this situation, specify the full path to the con-
     figuration file with either the '-c' Heyu command line switch or  with  the
     environment variable X10CONFIG.
     Also, specify the full Heyu executable pathspec, e.g., /usr/local/bin/heyu,
     if  your  crontab	path  does not include the directory where the Heyu exe-
     cutable is located.

     The timers and macros to be uploaded the the CM11A's EEPROM are stored in a
     file.  The default is $HOME/.heyu/x10.sched  or  /etc/heyu/x10.sched.   See
     x10sched(5) for the layout of the file.

     X10  modules  are	identified by a one-letter housecode ranging from A to P
     (for 16 different codes) and a number from 1 to 16, for a total of 256 pos-
     sible unit codes. The character '*' is interpreted to mean all  units  1-16
     (but must be escaped if entered on the command line).

     Heyu  spawns  a  relay daemon that gathers the CM11A output for any process
     that wants it.  This allows running the monitor while sending  on/off  com-
     mands.   Just  as important is that it also catches power fail messages and
     responds to them immediately.

     As of version 2, a state engine daemon may optionally be started which will
     maintain a record of the state of each module on the system, and which  has
     the capability of executing scripts.

     Heyu  supports  multiple CM11A units connected to different serial ports on
     the same computer.  The configuration files for each CM11A must  be  stored
     in  different  directories  - it's usually most convenient to store them in
     subdirectories /0 through /9 of the normal locations.  Each CM11A	operates
     independently of the others (except for communication via the house wiring)
     and has its own set of associated files.

OPTIONS
     -v   Enable verbose mode

     -c  <pathname>  Specify full configuration file pathname

     -s  <pathname>  Specify full schedule file pathname

     -0 ... -9	Look for config file in subdirectory /0 ... /9 of standard loca-
     tion, e.g., $HOME/.heyu/3/x10config

COMMANDS
     Heyu's  commands  are divided into Administrative, State, Direct, and CM17A
     "Firecracker" commands.

     Administrative commands generally control some feature of the CM11A or dis-
     play information from the CM11A, or display information about Heyu or about
     the user's configuration.

     State commands return in various formats information  about  the  state  of
     modules  on  the  user's system which has already been stored in the tables
     maintained by Heyu Engine.  They don't  attempt  to  update  these  tables.
     They  are	primarily  intended  to be called by scripts.  Note however that
     scripts launched by the Heyu state engine (excluding heyuhelper) are passed
     an environment which already contains most all the state information.   Any
     of  the  state commands require that the Heyu state engine daemon (heyu_en-
     gine) be running.

     Direct commands are used to transmit specific module  control  instructions
     out over the AC power line through the CM11A interface.

     CM17A  "Firecracker"  commands  transmit X10 RF signals if there is a CM17A
     device connected to the serial port.

ADMINISTRATIVE COMMANDS
     date   Gets current date and time from the CM11A  clock/calendar  and  dis-
	    plays it in a form suitable for feeding to date(1) as input.

     erase  Erases the CM11A's EEPROM.	All events, macros, etc  are permanently
	    gone.

     info   Displays  the current setting of CM11A's clock, base housecode, bat-
	    tery timer, and monitored housecode registers.  It also displays the
	    status of the uploaded timer schedule, if any.

     help   Displays a list of the commands that  are  available.   If	executed
	    with  the  name of a command as a parameter, it will display the the
	    syntax for that command only.  If executed with the  parameter  'ad-
	    min', 'state', 'direct', 'cm17a', 'shutter', 'rfxsensor', or 'rfxme-
	    ter' it will display only the commands of that type.

     syn    Displays built-in synonyms for many of the common direct commands.

     <scene_label>
	    Executes  a  scene or user-defined synonym (usersyn) from the user's
	    configuration file.

     show   Display various information from the user's  configuration	file  or
	    about the state of the system. Run 'heyu show' with no other parame-
	    ters to see the options available in the current release.

	    al[iases]	   Aliases defined in config file
	    ar[med]	   Armed status of Heyu
	    sc[enes]	   Scenes defined in config file
	    se[nsors]	   Sensor health report.
	    u[sersyns]	   Usersyns defined in config file
	    m[odules] H    Module attributes, housecode H
	    l[aunchers]  [H]  Launcher attributes, all, or housecode H (or -p -s
	    -r -t)
	    h[ousemap] [H] Overall system state, or details housecode H (*)
	    da[wndusk]	   Dawn and Dusk used for 'night' and 'dark' flags (*)
	    dim[levels]    Dim levels of modules as percent brightness (*)
	    r[awlevels]    Native levels of modules (0-210, 1-31, 0-63) (*)
	    f[lags]	   Software flags (*)
	    ti[mers]	   Countdown times for active timers (*)
	    ts[tamp] Hu    Data and time of last signal to address Hu (*)
	    g[roups] H	   Extended code group assignments and levels (*)
	    x[10sensors]   Tabular display of X10 Security sensors (*)
	    dig[imax]	   Tabular display of DigiMax sensors (*)
	    rfxs[ensors]   Tabular display of RFXSensor sensors (*)
	    rfxm[eters]    Tabular display of RFXMeter sensors (*)
	    or[egon]	   Tabular display of Oregon sensors (*)
	    ot[hers]	   Cumulative received address map (*) - clear with
			     'heyu initothers' or 'heyu initstate'
	    (*) Require the heyu state engine to be running

     upload By itself (heyu upload), the upload command reads timers,  triggers,
	    and macros from the user's schedule file, processes it and creates a
	    binary memory image, and uploads this image into the CM11A's EEPROM.

	    Upon  successful  completion, the following files are written to the
	    hard drive in Heyu's base directory.

	    x10record	-  Heyu's memory of the mode and time of the most recent
	    uploaded schedule.	(This _must_ remain intact for Heyu to know  how
	    to reset the CM11A clock when required.)

	    x10macroxref  - A listing of the EEPROM addresses of uploaded macros
	    for use by Heyu's state engine and monitor.

	    x10image	-  The 1024 byte binary image of the EEPROM.  It's  also
	    used by Heyu's state engine and monitor

	    report.txt	 -   The  full	details of Heyu's processing of data up-
	    loaded to the EEPROM.

	    If there are errors in the schedule file, the load will abort  with-
	    out changing anything.

	    The  upload  command with the check option (heyu upload check)  will
	    check the config file and report any errors.  The only file  written
	    to	the hard drive is the same 'report.txt' mentioned above. (A con-
	    figuration file directive can be used to  force  writing  the  other
	    files with a ".check" extension.)

	    The upload command with the croncheck option (heyu upload croncheck)
	    is	only  applicable when Heyu is configured to operate in HEYU mode
	    (see x10config(5) for a description of the MODE directive).  It  re-
	    peats  the data processing Heyu would do if 'heyu upload check' were
	    executed daily for the next 366 days  and  writes  a  file	'cronre-
	    port.txt'  to  the hard drive with a daily summary.  (Its purpose is
	    to prevent unpleasant surprises if 'heyu upload' is to  be	executed
	    automatically as a cron job.)

	    The  upload  command  with the status option (heyu upload status) or
	    the cronstatus option (heyu upload cronstatus) reports the number of
	    days before the currently uploaded schedule will expire.  These  op-
	    tions  are	useful	primarily  when Heyu is configured to operate in
	    HEYU mode, where the period of validity of the schedule is	variable
	    at	the user's option.  The difference between the two, i.e., status
	    and cronstatus, is that 'status' displays a  human-readable  message
	    whereas  'cronstatus'  displays only the number of days (or an error
	    code) for convenient parsing in a cron script.  The codes are:

	      >= 0  Number of days until expiration (0 = Today is last day)
		-1  SCHEDULE_EXPIRED  (Schedule must be reloaded)
		-2  NO_EXPIRATION     (Schedule contains no timers)
		-3  NO_RECORD_FILE    (No schedule has been uploaded)
		-4  BAD_RECORD_FILE   (File x10record is corrupted.)

     catchupReads the EEPROM image binary file x10image saved when a schedule is
	    uploaded and immediately executes in chronological	order  the  com-
	    mands in the macros for each timed event scheduled for today's date,
	    beginning  at 00:00 hours and continuing up until the current system
	    time.

     triggerAn uploaded macro can only be executed by an uploaded  timer  or  if
	    triggered by a powerline command.  The 'heyu trigger Hu on|off' com-
	    mand  emulates  a powerline trigger by looking up the trigger condi-
	    tion and macro commands in the x10image and x10macroxref files saved
	    by Heyu when a schedule is uploaded.  It then executes them  as  di-
	    rect commands.  Macro delays are ignored.

     macro  Using  the	x10macroxref and x10image files saved when a schedule is
	    uploaded, 'heyu macro <label>' looks up the commands comprising  the
	    macro  with  the argument label and immediately executes them as di-
	    rect commands.  Macro delays are ignored.

     monitorWhen executed in a separate terminal window, all X10 events sent and
	    received by the CM11A interface will be displayed  in  this  window.
	    The  output  goes to stdout and may be redirected to a file (however
	    the log file generated by the Heyu state engine process contains the
	    same information, and more).  The events are time-stamped and  iden-
	    tified as to their source with the following codes:
	    sndc  - Sent from the Heyu command line.
	    snda  - Transceived from RF by the heyu_aux daemon.
	    snds  - Sent by Heyu from within a script. (*)
	    sndp  - Sent by Heyu from within a power-fail script. (*)
	    sndm  - Sent by an uploaded macro when initiated by a Timer.
	    sndt  - Sent by an uploaded macro when initiated by a Trigger.
	    rcvi  - Received over the AC power line.
	    rcvt  - A Trigger signal which initiated an uploaded macro.
	    rcva  - RF signals received from the heyu_aux daemon.

	    (*) When that script is launched by the Heyu state engine daemon.

     start  Starts  the Heyu relay daemon and other configured daemons, i.e., it
	    will also start the Heyu Engine daemon if the  directive  'START_EN-
	    GINE AUTO' appears in the configuration file and will start the Heyu
	    Auxilliary daemon if the 'TTY_AUX ...' directive appears in the con-
	    figuration file.

     restartDirects all running Heyu background processes - heyu_relay, heyu_en-
	    gine,  heyu_aux  -	plus Heyu monitors, to re-read the configuration
	    file and incorporate any changes since these processes were started.

     stop   Kills the heyu_relay daemon that gathers input from  the  tty  port.
	    This  will	also  cause  heyu_engine,  heyu_aux, and any monitors to
	    stop.  It can only kill the processes that you have  permissions  to
	    stop.

     engine Starts  the  Heyu  state  engine  daemon,  heyu_engine, a background
	    process which maintains a record of the state of each  module  based
	    on	X10 signals sent or received, and which can launch scripts based
	    on these signals.  If so enabled in the configuration file, its out-
	    put, similar to that of the monitor, is written to a log file.
	    This command will not be needed if the directive "START_ENGINE AUTO"
	    is	included  in  the  configuration  file	and  Heyu's   background
	    processes are initiated by running 'heyu start'.

	    Whenever changes are made to the configuration file, the engine must
	    be	restarted  for	the  changes  to  be  incorporated.   (Run 'heyu
	    restart' to restart it.)

	    Warning: The record of module states maintained by the state  engine
	    can  be  in  disagreement with reality for any number of reasons and
	    should never be relied on for critical applications.

     aux    Starts the auxiliary daemon heyu_aux, a background process which al-
	    lows X10 commands to  be  input  to  Heyu  via  RF	signals  from  a
	    W800RF32A,	MR26A, or RFXCOM serial receiver, or from an RFXLAN net-
	    work receiver.  The serial port to which the receiver is  connected,
	    or	the  network  address in case of RFXLAN, and the receiver device
	    type must be specified in the configuration file  with  the  TTY_AUX
	    directive.

	    This  command  will not be needed if Heyu's background processes are
	    initiated with the 'heyu start' command.

     script_ctrl
	    Globally disables ('heyu script_ctrl  disable')  or  enables  ('heyu
	    script_ctrl  enable')  launching  of  scripts by Heyu.  This command
	    overrides the configuration directive SCRIPT_CTRL  (or  its  default
	    value of ENABLE).

     initstate
	    If no housecode is specified, initializes the entire X10 state table
	    to zero.  With a housecode (heyu initstate H), initializes the state
	    table to zero for just that housecode.

     initothers
	    Initialize the cumulative received address state table to zero.

     reset  The  default  action  for reset is to clear the registers in the the
	    CM11A and to set it to the default housecode defined in the configu-
	    ration file.  The CM11A will  then	track  state  changes  for  that
	    housecode in its internal registers.  If a housecode is specified as
	    an	argument,  the	CM11A will be set to track state changes on that
	    housecode instead.	Note that the state recorded in the CM11A inter-
	    nal registers is completely independent of the all-housecode  states
	    tracked by the Heyu state engine.

     setclock
	    Reads  the	system	clock  and loads it into the CM11A.  This is ad-
	    justed for local daylight savings time and for the mode  of  an  up-
	    loaded  schedule,  if any.	As of Heyu version 2, the CM11A clock is
	    maintained on local Standard Time throughout the year.

     readclock
	    Displays the date and time for the CM11A and system clocks.  The raw
	    data from the CM11A clock is adjusted  for	local  daylight  savings
	    time and for the mode of an uploaded schedule, if any.

     newbattery
	    Resets the CM11A battery timer to zero.

     purge  Cancel  any  pending delayed macros, i.e., delayed macros which have
	    been called by a timer or trigger but have not yet been executed.

     clear  Clear the CM11A unit status registers for the monitored housecode.

     utilitySeveral infrequently-used options are available:

	    'heyu utility syscheck' displays clock/calendar/timezone information
	    obtained from the system by Heyu.  Use this to make sure  that  your
	    system's time configuration is what you think it ought to be.

	    'heyu  utility dawndusk' displays the times of Dawn and Dusk for to-
	    day.

	    'heyu utility suntable  [-r|-c|-n|-a|-o  [-]nn]  [-s]  [-w]  [yyyy]'
	    writes a file to the hard drive containing a daily table of Dawn and
	    Dusk as computed by Heyu for your Longitude, Latitude, and Timezone,
	    for the current year or for year yyyy. By default, Dawn and Dusk are
	    as defined by the DAWNDUSK_DEF directive in your configuration file,
	    times displayed are Civil (i.e., wall-clock) times, and the table is
	    80 columns wide.
	    Switches  -r,  -c, -n, -a or -o [-]nn direct Heyu to use the defini-
	    tion of Dawn and Dusk as either Sunrise/Sunset, or	Civil,	Nautical
	    or	Astronomical Twilight, or a specified position of the Sun centre
	    in angle minutes below the horizon (actually above	the  horizon  if
	    -nn),  respectively, overriding the definition of Dawn and Dusk from
	    your configuration file.
	    Switch -s displays times as Standard Time throughout  the  year  in-
	    stead of Civil Time.
	    Switch  -w	writes	the table in wide (135 column) format instead of
	    the default 80 columns.  (Printing this table on  US  Letter  or  A4
	    size  paper  requires  landscape  orientation  and	an 8-point fixed
	    font.)

	    'heyu utility calibrate' provides the timing loop calibration needed
	    for CM17A Firecracker "fast" commands  and	some  experimental  com-
	    mands.

	    'heyu  utility masks' displays the numerical value of the mask envi-
	    ronment variables for Heyu and Xtend environments.	 (For  use  with
	    'heyu heyu_state', 'heyu heyu_rawstate', and 'heyu xtend_state'.)

     logmsg Writes  its  quoted-text  argument	(max  length 80 characters) as a
	    time-stamped entry in the Heyu logfile and on  the	monitor  screen.
	    (There's  no checking to see whether either the engine or monitor is
	    actually running.)	This is primarily intended for making occasional
	    notes while testing and may or may not play well if executed in  the
	    midst of X10 power line activity.  It will also increase the size of
	    the  spool	file by a few bytes more than the length of the text, so
	    should be used sparingly.
	    Example:
	      heyu logmsg "Awaiting signals from my new wall switch  and  trans-
	    ceiver."

     cm10a_init
	    Manually re-initialize a CM10A interface provided Heyu has been con-
	    figured for a CM10A instead of a CM11A.  Note that when thus config-
	    ured,  the Heyu relay should handle this automatically after a power
	    interruption.

     wait   Wait until execution of an uploaded macro has completed  before  re-
	    turning.   This is primarily intended for use when a script or shell
	    command is launched by an X10 command executed  within  an	uploaded
	    macro, i.e., with launch source SNDM or SNDT, when it's important to
	    be	certain  that the execution of the macro has been completed.  If
	    the timeout parameter is omitted, the default timeout is 30 seconds.
	    This command operates by repeatedly pinging the CM11A once a  second
	    until it echoes back the ping character.

     restore_groups
	    Primarily  intended  for  use following an interruption of AC power,
	    this command sends the X10 signals to all modules  defined	as  sup-
	    porting  extended  code  groups to restore the group assignments and
	    xconfig mode to the settings preserved in the X10 state file.   (Run
	    'heyu show groups H' to display the group settings.)

     logtailCalls  the	system 'tail' command to display the last N lines of the
	    Heyu log file.  If parameter N is omitted, the default for the  sys-
	    tem  tail  command, typically 10 lines, is displayed.  The directory
	    where the log file is maintained must have been specified  with  the
	    LOG_DIR directive in the Heyu configuration file.

     launch Launches  a  script  defined  by  a  SCRIPT directive provided a re-
	    stricted subset of the launch conditions  are  satisfied.	For  all
	    scripts,  the  sources,  keywords, and flags other than global flags
	    are disregarded in the launch conditions.

	    For a Normal script, function tokens on, off, dim, and  changed  are
	    interpreted  as  representing  the	on/off/dim/changed  state of the
	    specified module addresses rather than signals.  All other	function
	    tokens  are  disregarded.	The launch condition is satisfied if any
	    one of the state comparisons is TRUE and all the  global  flags  are
	    TRUE.
	    For  an  Address  script  the launch conditions are satisfied when a
	    module is in the addressed state and the global flags are true.

	    The syntax is:
	       heyu launch [-e] [-L<n>] <script_label>
	    For a Normal or Address script, the -e switch instructs Heyu to  ig-
	    nore  the  functions and addresses and test only the global flags in
	    the launch conditions, as if it were an -exec script.

	    Each set of launch conditions for a script is tested in the same or-
	    der as for a script launched by an X10 signal.  For  a  script  with
	    multiple launchers, the testing can be confined to a single launcher
	    by	providing  the	launcher  number  <n>  with  the  -L<n>  switch.
	    Launcher numbers start at 0 for each script  and  are  displayed  in
	    square  "[]"  brackets  following  the  script  label  in 'heyu show
	    launchers' command when there is more than one. (If  there	is  only
	    one  set  of launch conditions, the launcher number will always be 0
	    and is not displayed.)

	    Examples:

	    For the directive:
	      SCRIPT -l CheckLights A1-16 on notnight nosrc; B1-16  on	notnight
	    nosrc :: ...
	      heyu launch CheckLights
	      heyu launch -L1 CheckLights

     versionPrints the version number and then exits.

STATE COMMANDS
     These  commands  are primarily intended for external scripts or programs to
     obtain state information from Heyu which has previously been stored in  the
     state  tables maintained by the Heyu engine.  Scripts and programs launched
     by the Heyu engine already have access to complete  state	information  via
     the  environment  variables passed to them.  For a more human-readable dis-
     play, use the 'heyu show housemap [H]' command.

     These commands will display the various states of a module.  The  parameter
     is  a  single-unit housecode|unit string 'Hu' or just a housecode 'H'.  (An
     alias is also accepted.)  For the flagstate command, the parameter is  just
     the number of the flag (1-N).

     The  format  for some of the state commands has been changed to the follow-
     ing.  See below for the older formats, which are still available.

	enginestate	State engine daemon is running (1) or not running (0)
	armedstate	Bitmap: 1 = Armed, 2 = Home, 4 = ArmPending, 8 = tamper
	sensorfault	Bitmap: 1 = Low battery, 2 = Inactive, 8 = tamper
	flagstate  n	State of flag n as either 1 (set) or 0 (clear)
	nightstate	State of night flag as 1 (night) or 0 (notnight)
	darkstate	State of dark flag as 1 (dark) or 0 (notdark)
			(Dark is defined by config directive ISDARK_OFFSET)
	sunstate	Bitmap: 1 = Night, 2 = Dark

     In the following, specifying a housecode|unit (Hu) will display the boolean
     value 1 or 0 representing that Hu is in or not in that state, respectively.
     Specifying only the Housecode will display a unit bitmap (as an integer) of
     the units which are in that state, with bit 0 corresponding to unit 1,  bit
     1 to unit 2, bit 2 to unit 3, etc.
	onstate   H[u]	  On state
	offstate   H[u]   Off state (not On)
	dimstate  H[u]	  Dim state
	addrstate H[u]	  Addressed state
	chgstate  H[u]	  Changed state
	fullonstate  H[u]  Fully On state (On and not Dim)
	alertstate H[u]   Alert state
	clearstate H[u]   Clear state
	auxalertstate H[u]   AuxAlert state
	auxclearstate H[u]   AuxClear state
	lobatstate H[u]   Low Battery state for sensors
	validstate H[u]  Function processed state (*)
	activestate H[u]  Active state for sensors
	inactivestate H[u]  Inactive state for sensors
	spendstate H[u]   Status-pending flags (**)
	statusstate H[u]  Deprecated - same as spendstate H[u]

     (*) validstate H[u] indicates that a signal supported by the module type at
     H[u]  has	been  sent  or	received in the Heyu State Engine since Heyu was
     started.

     (**) When Heyu sends or receives a status or xstatus signal, the Heyu State
     Engine sets a status-pending flag for the addressed unit in its  state  ta-
     ble.   When  it receives a StatusOn, StatusOff, or xStatusAck return signal
     from a 2-way module, it resets this flag for the addressed unit.
     If the status-pending flag remains set  after  an	expected  response  time
     (which  may be a few seconds), it's an indication that something is wrong -
     possibly a missed signal, a tripped circuit breaker or GFI, or a 2-way mod-
     ule unplugged or simply gone bad.
     Note that most common modules are only 1-way and don't respond to a  status
     request.  The state of the status-pending flag is therefore meaningless for
     those modules.  Note also that the status-pending flag will  NOT  be  reset
     for  2-way modules (like many SwitchLinc and LampLinc modules) which return
     a brightness level rather than a StatusOn/StatusOff signal.

     The 'sensorfault' command provides a quick  check	of  sensors  defined  by
     their module types in an ALIAS directive as being security sensors.
     A	displayed  value  of 0 indicates all security sensors are operating nor-
     mally, otherwise the consolidated bitmap with 1 indicates a low battery  in
     one  or  more  sensors, and the bitmap with 2 indicates one or more sensors
     haven't reported in the elapsed time defined by the  INACTIVE_TIMEOUT  con-
     figuration  directive.  Run 'heyu show sensors' for a detailed report iden-
     tifying the individual sensors with problems.

     The old format is available for compatibility by setting the  configuration
     directive	OLD_STATE_FORMAT  to YES.  The commands require a housecode|unit
     parameter Hu and display the output in the heyuhelper style.  Example  out-
     puts are shown in parentheses for Hu = B8.

	onstate   Hu	State of Hu as either On or Off  (b8On, b8Off)
	dimstate  Hu	State of Hu as Dim, On, or Off	(b8Dim, b8On, b8Off)
	addrstate Hu	Addressed state of Hu  (b8Addr, b8Unaddr)
	chgstate  Hu	Changed state of Hu  (b8Chg, b8Unchg)

     The  following  command displays the state of all units on housecode H as a
     16 character ASCII string.   Characters  1-16  represent  respectively  the
     states of Units 1-16, each as a (lower-case) hexadecimal digit 0-0xf formed
     by  adding  together  the state values On = 8, Dimmed = 4, Changed = 2, Ad-
     dressed = 1.
	statestr  H    (8c30000000000000)

     The above example indicates H1 is On, H2 is On and Dimmed, H3  was  changed
     to Off by the most recent command on housecode H and remains addressed, and
     H4-16 are all Off and unaddressed.

     The following return the current brightness or native level of module Hu as
     recorded  by the Heyu state engine.  (For Hu addresses of X10 security sen-
     sors, the security data byte is returned.)

	dimlevel  Hu	Brighness level of Hu as 0-100%  (50)
	rawlevel  Hu	Native level (0-210, 1-32, or 0-63) of Hu (32)

     The following return respectively the stored brightness  level  0-100%  and
     stored  native level for modules which retain the memory of a previous set-
     ting, e.g., lamp modules which support the Resume or On-Level  feature,  or
     shutter controllers which store a limit value.  The level returned for mod-
     ules  without a memory feature will be just the maximum level for that mod-
     ule type. (For Hu addresses of two-channel X10 security sensors  configured
     in dual mode, the security data byte for the Aux channel is returned.)

	memlevel  Hu	Stored brightness level of Hu as 0-100%
	rawmemlevel Hu	Stored native level of Hu

	counter N	Value of counter N

     The  following  return  the  state bitmap of a module as a decimal integer.
     See x10scripts(5) for the meaning of each bit, which differs for  Heyu  and
     Xtend  bitmaps.   These  are  the	values	of the variables provided in the
     script environment as 'X10_Hu'.

	heyu_state  Hu	Heyu script environment state bitmap with dimlevel as  a
     percentage of full brightness.
	heyu_rawstate  Hu Heyu script environment state bitmap with native level
     (0-210, 1-32, 0-63, 0-15, 0-255).
	heyu_vflagstate Hu  Heyu script environment vFlag state bitmap
	xtend_state Hu	Xtend script environment state bitmap

	rcstemp H  Retrieves the stored value of temperature from an RCS compat-
     ible thermometer which has previously been stored in the Heyu Engine  state
     tables by either an automatic report or resulting from a query of the ther-
     mometer.

     The  following  command  directs the state engine to write an updated state
     file to the hard drive.

	fetchstate

     This command should be required only if the  configuration  directive  AUT-
     OFETCH  has  been	changed  to  NO,  _and_  it's  important to know the ad-
     dressed/unaddressed state of a module.  Here's why:
     The state engine automatically updates the state file whenever an X10 func-
     tion is sent or received, but not when an X10 address is sent  or	received
     until the X10 function which normally follows.  The state file is used only
     when  a state command, e.g., 'onstate' or 'dimstate' command is issued from
     the command line.	(The environment  variables  supplied  by  Heyu  when  a
     script  is  launched  by the state engine are created directly from the en-
     gine's memory record and not the state file.)

     Of the state commands, only 'addrstate', 'heyu_state', 'xtend_state' report
     the addressed state of a module or modules.  If the configuration directive
     AUTOFETCH retains its default value of YES, these commands  will  automati-
     cally  call for an update of the state file.  If AUTOFETCH is changed to NO
     _and_ an X10 address is sent or received without a following X10  function,
     then  it  will  be necessary to execute 'heyu fetchstate' before the any of
     the above mentioned state commands in  order  for	the  reported  addressed
     state to be correct.

     Example:  If  AUTOFETCH is set to NO and the following sequence of X10 sig-
     nals is received:
	address unit 1 : housecode A
	function    On : housecode A
	address unit 2 : housecode A

     Then the command 'heyu addrstate An' will incorrectly show A1 as  addressed
     and A2 as unaddressed unless 'heyu fetchstate' is run first.

     (The  above  may  be  a little confusing but the vast majority of users can
     safely ignore both the 'fetchstate' command and the AUTOFETCH configuration
     directive.)

     The following state commands retrieve data  received  from  RFXSensors  and
     stored in Heyu's state tables.  See man page x10rfxsensors(5) for details.

	rfxtemp Hu  Stored Temperature
	rfxrh Hu    Stored Relative Humidity
	rfxbp Hu    Stored Barometric Pressure
	rfxvs Hu    Stored Supply Voltage
	rfxvad Hu   Stored A/D Voltage
	rfxvadi Hu  Stored internal A/D Voltage
	rfxpot Hu   Stored Potentiometer setting
	rfxtemp2 Hu Stored Second Temperature
	rfxlobat Hu Stored Low Battery status (1 = Low, 0 = Normal)

     The  following  state  commands  retrieve	data received from RFXMeters and
     stored in Heyu's state tables.  See man page x10rfxmeters(5) for details.

	rfxpower Hu  Stored Watt-Hour meter reading.
	rfxpanel [N] Stored total Watt-Hour reading for power panel N
	rfxwater Hu  Stored Water meter reading
	rfxgas	 Hu  Stored Gas meter reading
	rfxpulse Hu  Stored Pulse meter reading
	rfxcount Hu  Stored raw counter reading

     The following state commands retrieve data received from  the  DigiMax  210
     Thermostat.  See man page x10digimax(5) for details.

	dmxtemp     Hu	Stored current temperature (C)
	dmxsetpoint Hu	Stored setpoint temperature (C)
	dmxstatus   Hu	Stored On/Off status (1 = On)
	dmxmode     Hu	Stored Heat/Cool mode (1 = Heat)

     The  following  state  commands retrieve data received from Oregon Tempera-
     ture/Relative Humidity/Barometric Pressure sensors or  from  Wind	or  Rain
     sensors.  See man page x10oregon(5) for details.

	oretemp      Hu  Stored temperature reading.
	orerh	     Hu  Stored Relative Humidity.
	orebp	     Hu  Stored Barometric Pressure.
	orewindavsp  Hu  Stored Wind Average Speed.
	orewindsp    Hu  Stored Wind Instantaneous Speed.
	orewinddir   Hu  Stored Wind Direction angle.
	orerainrate  Hu  Stored Rainfall Rate.
	oreraintot   Hu  Stored Rainfall Total Accumulation.
	elscurr      Hu  Stored Electrisave Current reading.

     The  following  command allows an external program to store Temp/RH/BP data
     in the state table for a emulation (dummy) Oregon module for processing  by
     Heyu, just as if the data were received from an actual Oregon sensor.

	heyu ore_emu  Hu  <func>  <value>

     See section "OREGON SENSOR EMULATION" in man page x10oregon(5) for details.

     The  following  command allows an external program to emulate a signal from
     an X10 Security sensor or remote, as if the signal were  received	from  an
     actual device.

	heyu sec_emu  Hu  <func>  <flags>

     where  <funct>  must  be  one which is transmitted by the physical security
     sensor or remote mapped to Hu. Like other Heyu function names  it	must  be
     entered in all lower case.
     <func>  may be:  alert, clear, sectamper, panic, arm, disarm, test, slight-
     son, slightsoff, sdusk, sdawn, akeyon, akeyoff, bkeyon, or bkeyoff.

     The <flags> must be specified as they would appear in  the  monitor/logfile
     when an actual RF transmission is received, although they are not case sen-
     sitive  and  can  appear  in  any order after the <func>.	There are no de-
     faults, e.g., for a door/window sensor with a Min/Max switch, either  swmin
     or swmax must be specified.
     <flags>  may be: swmin, swmax, swhome, swaway, main, aux, and lobat as sup-
     ported by the particular sensor.  Do not specify the tamper flag as  it  is
     handled differently from the other flags.

DIRECT COMMANDS
     Heyu version 2 greatly expands the number of commands which can be executed
     directly from the command line.  All commands which the CM11A is capable of
     sending  are  now available, although many of them will be of little use to
     the average user.

     Enter 'heyu help' for a complete up-to-date listing  of  the  commands  and
     their syntax.  A number of commands have synonyms which some users may find
     easier to remember.  Enter 'heyu syn' to see the synonyms for each command.
     Although  a few commands are different, the command syntax in general is as
     follows:

	heyu  <command>  Housecode|Units  [<data>]

     The usual Housecode|Units address is comprised of a case-insensitive house-
     code letter A through P, followed with no intervening spaces by a	list  of
     the particular unit codes to be addressed, ranging from 1 through 16.  Unit
     code  0  is acceptable (but not necessary) for commands which don't require
     any unit codes.

     An 'alias' defined in the configuration file can be  used	in  place  of  a
     Housecode|Units string.

     For any command, using an underscore ('_') in place of the housecode letter
     will direct Heyu to substitute the default housecode defined in the config-
     uration file.

     The  units  list  may consist of a single unit, multiple units delimited by
     commas, a range of units separated with a '-' sign, or a combination of the
     foregoing.

     The following are examples of valid Housecode|Unit addresses:
	A7
	B3,5
	g2,4,6-9,11,14-16

     For commands which apply to all units in a given housecode, the units  list
     is omitted, e.g.,

	heyu lightson  B

     Direct Command listing (H = Housecode, HU = Housecode|Units):

     on  HU		      Turn units ON
     off  HU		      Turn units OFF
     dim  HU <level>	      Dim by <level> (1-22)
     dimb  HU <level>	      Dim to <level> (1-22) after full bright
     obdim HU <level>	      Dim to <level> after on and full bright.
     bright  HU <level>       Brighten by <level> (1-22)
     brightb  HU <level>      Brighten by <level> (1-22) after full bright
     lightson  H	      Turn All Lights ON
     lightsoff	H	      Turn All Lights OFF (**)
     allon  H		      Turn All Units ON
     alloff  H		      Turn All Units OFF
     turn  HU <command>       Change state on|off|up|down [vv]
     preset  HU <level>       Preset units to <level> (1-32) (*)
     mpreset  HU <linked>     Limited Preset for uploaded macros
     preset_level  <level>    Preset to <level> (1-32) (function only)
     status  HU 	      Request ON/OFF status (two-way modules)
     status_on	HU	      Status Acknowledge ON
     status_off  HU	      Status Acknowledge OFF
     hail  [H]		      Hail other devices
     hailw  [H] 	      Hail other devices, await ack (*)
     hail_ack  [H]	      Hail Acknowledge
     data_xfer	H	      Data Transfer (function code 0xC)
     xon  HU		      Extended Turn Units Full ON (LM14A)
     xoff  HU		      Extended Turn Units Full OFF (LM14A)
     xpreset  HU <level>      Extended Preset <level> (0-63) (LM14A)
     xallon  H		      Extended All Units ON (LM14A)
     xalloff  H 	      Extended All Units OFF (LM14A)
     xstatus  HU	      Extended Status Request (LM14A)
     xconfig  H <mode 0-3>    Extended Config Auto Status Report (LM14A)
			      (0 = Off, 1 = Extended, 2 = Standard, 3 = Either)
     xpowerup HU	      Extended Module PowerUp signal (LM14A)
     xgrpadd HU G	      Include HU in group G (0-3) at current level
     xgrpaddlvl HU g <level>  Include HU in group g (0-3) at level (0-63)
     xgrprem HU g[,g,...]     Remove HU from group(s) in list.
     xgrpremall H g[,g,...]   Remove all housecode H from group(s) in list
     xgrpexec H G	      Execute functions for housecode H, group G
     xgrpstatus HU G	      Return level (or Nack) for unit(s) in group G.
			      (for 2-way modules only)
     xfunc  <T/F> HU <Data>   Extended command - general
     xfuncw  <T/F> HU <Data>  Extended command - general, await ack (*)
     address  HU [HU [...]]   Send HC|Units addresses only (*)
     function  <command ...>  Send command function only
     kill_all_hc	      Send All_Units_Off to All Housecodes
     pause  N.NNN	      Pause for N.NNN seconds (*)
     sleep  N.NNN	      Sleep for N.NNN seconds (*)
     delay NNN		      Delay for NNN minutes (*)
     rdelay [MIN] MAX	      Delay random time between MIN and MAX minutes (*)
     temp_req  <query_cmd>    Request temperature (RCS compatible) (*)
     rcs_req  <query_cmd>     Request RCS compatible status (*)
     vdata  HU <Data>	      Write data to primary byte at address HU (*)
     vdatam  HU <Data>	      Write data to memory byte at address HU (*)
     arm  [parameters]	      Arm system [home|away] [min|max] (@) (*)
     disarm		      Disarm system (@) (*)
     setflag  n[,n...]	      Set one or more flags (@) (*)
     clrflag  n[,n...]	      Clear one or more flags (@) (*)
     clrspend H[U]	      Clear status-pending flags for H[U] (*)
     clrstatus H[U]	      Deprecated - same as clrspend
     settimer N <hh:mm:ss>    Set countdown timer N to hh:mm:ss (@) (*)
     clrtimers		      Reset all countdowns timers to zero (@) (*)
     clrtamper		      Reset the global tamper flag (@) (*)
     setcount N <count>       Set counter N to count (0-64K) (@) (*)
     inccount N 	      Increment counter N by 1 (@) (*)
     deccount N 	      Decrement counter N by 1 (@) (*)

     (*)  Not available for use in uploaded macros.
     (**) Many dimmer modules do NOT support this command.
     (@)  Ignored if the Heyu state engine daemon is not running.

     Additionally, if Heyu has been configured to recognize Extended Code Type 0
     (Shutter and Shade) commands:

     shopen  HU <level>      Open shutter to level (0-25) and cancel limit
     shopenlim	HU <level>   Open shutter to level (0-25), enforce limit
     shsetlim  HU <level>    Set limit (0-25) and open shutter to limit
     shopenall	H	     Open all shutters fully and cancel limit
     shcloseall  H	     Close all shutters fully

     (The  only  module known to support these shutter commands is the 230 Volt,
     50 Hz, Marmitek SW10 Shutter Motor Controller sold in Europe, and	Marmitek
     keeps this support a secret.)

     Internal  engine precommands.  These work the same as the corresponding di-
     rect commands without the '@' prefix but are used ONLY in the command  line
     of  a  SCRIPT  directive.	 See the SCRIPT COMMAND LINE section of man page
     x10scripts(5) for details.

     @arm  [parameters]        Arm system [home|away] [min|max] (*)
     @disarm		       Disarm system
     @setflag  n[,n...]        Set one or more flags (*)
     @clrflag  n[,n...]        Clear one or more flags (*)
     @clrspend H[U]	       Clear status-pending flags for H[U] (*)
     @settimer N <hh:mm:ss>    Set countdown timer N to hh:mm:ss (*)
     @clrtimers 	       Reset all countdown timers to zero (*)
     @vdata HU <byte>	       Write data (0-255) to HU primary address (*)
     @vdatam HU <byte>	       Write data (0-255) to HU memory address (*)
     @setcount N <count>       Set counter N to count (0-64K) (*)
     @inccount N	       Increment counter N by 1 (*)
     @deccount N	       Decrement counter N by 1 (*)
     @decskpz N 	       Decrement counter N by 1 and skip if zero (*)
     @decskpnz N	       Decrement counter N by 1 and skip if not zero (*)
     @null		       Just a place holder - does nothing (*)

     More details on a few of these commands:

     The 'heyu obdim HU <level>' command is a  compound  command  equivalent  to
     running the scene 'on HU; bright -H 22; dim -H <level>'.  It is intended to
     replace  the  'dimb  HU <level>' command when compatibility of the new X-10
     WS467 Wall Switch (redesigned in 2007) with the original WS467  (and  other
     dimmers)  is  required.  (The redesigned WS467 cannot be turned on from the
     Off state by a dim or bright alone.)

     The _turn, _preset, and _status "legacy" commands in  earlier  versions  of
     Heyu have been removed.

     The  'setflag', 'clrflag', and 'clrstatus' commands are not strictly speak-
     ing direct commands because they send nothing to the CM11A and only control
     software flags in the state engine.  They are included with the direct com-
     mand group so they can be used in scenes and usersyns.

     The 'setflag' and 'clrflag' parameter may be a single flag number between 1
     and N, e.g., 'heyu setflag 4', or a comma	delimited  list  of  numbers  or
     ranges  of numbers, e.g., 'heyu setflag 2,3,5-7'.	If the state engine dae-
     mon is not running, these commands will be silently ignored.

     The 'arm' command controls the setting of Heyu global security flags  which
     can  be  tested  as  part of the launch conditions for Heyu scripts.  These
     flags are "disarmed", "armed", "notarmed", "armpending", "home" and "away".
     (The "notarmed" flag is set when either the "disarmed" or "armpending" flag
     is set.)

     The MIN or MAX parameter determines the delay before the system enters  the
     Armed state.  With MIN, the "armed" flag is set immediately.  With MAX, the
     "armpending"  flag  is  set  until  the  end of the delay time given by the
     ARM_MAX_DELAY configuration directive, at which time the flag  will  change
     from  "armpending"  to  "armed".  If neither MIN nor MAX is entered the de-
     fault is MIN.

     When the 'arm' command is issued at the command line,  Heyu  will	issue  a
     warning if any of the configured security door/window or motion sensors are
     in  the  Alert state, since many of these sensors will retransmit the Alert
     signal at their heartbeat intervals.

     The HOME or AWAY parameter sets the "home" or "away" flag respectively.  If
     neither HOME nor AWAY is entered, the default is AWAY.

     When the 'arm' command is received  from  an  RF  Security  remote  (signal
     source  RCVA),  the  automatic  setting of the global security flags as de-
     scribed above may be disabled with the config  directive  "ARM_REMOTE  MAN-
     UAL".   This  allows  using the command to launch a script to customize the
     arming process, e.g., if doors or windows are open, warn the user and don't
     arm the system.

     The 'disarm' command takes no parameters. It sets the "disarmed"  flag  and
     clears all the other global security flags.

     If  the 'hail' or 'hail_ack' commands are entered without a housecode, Heyu
     will supply the default housecode from the Heyu configuration file,  as  if
     an underscore were entered for the housecode letter.

     The  Heyu 'turn' command requires using the underscore to initiate replace-
     ment with the default housecode.  It supports the functions on, off, light-
     son, lightsoff, allon, alloff, dim, dimb, bright, brightb, or  any  of  the
     synonyms for these functions.
     The  'turn'  command  also  supports  the	CM17A  commands fon, foff, fdim,
     fbright, flightson, flightsoff, falloff, and the applicable  "fast"  imple-
     mentations of these commands.

     The Extended Code command 'xconfig' configures the automatic status report-
     ing mode of an X-10 2-way module like the LM14A or AM14A.
     The  module  can be directed to automatically report its status whenever it
     receives a command which changes its state.  The four modes are: 0 = Off; 1
     = Report status when an Extended command is received;  2  =  Report  status
     when  a Standard command is received; 3 = Report status when either a Stan-
     dard or Extended command is received.  (Note that the  mode  is  stored  in
     volatile  memory  in  the module and will be reset to the default mode 0 in
     the event of a power interruption.)

     The Extended Code module power-up signal 'xpowerup' is sent by  X-10  2-way
     modules  like  the LM14A and AM14A when they are powered up following an AC
     power interruption of at least a few seconds duration.  This signal is  in-
     cluded  as  a direct and macro command primarily for testing purposes - its
     primary use is in launch conditions for a script or shell command to recon-
     figure the status reporting mode of the module.

     The general Extended Code commands 'xfunc' and  'xfuncw'  require	entering
     the extended Type/Function for the desired function between the command and
     the Housecode|Units list.	Both the T/F and Data bytes are entered as hexa-
     decimal digits.  Example:

	heyu xfunc 31  M12  20

     (which is equivalent to 'heyu xpreset  M12  32')

     The  Extended  Code  Group command 'xgrpadd' allows a module which supports
     extended code (Type 3) functions, like the LM14A, to be assigned to  up  to
     four  groups  (0-3),  each  with an individual preset level (0-63).  Then a
     single 'xgrpexec' command executed for a group will set each member of that
     group on that housecode to the predefined preset level.  The 'xgrprem'  and
     'xgrpremall'  command removes either individual units or the entire housec-
     ode from one or more groups.  The 'xgrpstatus' command polls a (2-way) mod-
     ule for the extended preset level	for  a	group  stored  in  the	module's
     (volatile) memory.
     Examples:

	heyu xgrpadd A1,9 2
     adds modules A1 and A9 to group 2 at their current levels.

	heyu xgrpaddlvl A1,2,4	3  40
     adds modules A1, A2 and A4 to group 3 at extended preset level 40

	heyu xgrpexec A  2
     results in modules A1 and A9 simultaneously going to the levels defined for
     group 2.

	heyu xgrprem  A9  2
     removes A9 from group 2.

	heyu xgrprem  A1  2,3
     removes A1 from groups 2 and 3

	heyu xgrpremall  A  2,3
     removes all modules on housecode A from groups 2 and 3

	heyu xgrpstatus  A1  3
     for  2-way  modules  will be either acknowledged ("xGrpAck") by A1 with the
     preset level stored for group 3, or negative-acknowledged	("xGrpNack")  if
     A1 is not a member of group 3.

     Details  of Extended Codes defined by X-10 are found in their document xtd-
     codes.pdf which may be downloaded from their website.  (This  document  re-
     placed their older XTC798.DOC.)

     The  (old-style)  'preset' command has a peculiar coding - the housecode is
     not part of the function byte as it is for all other native  X10  commands.
     Since   Heyu's 'preset_level', i.e.  preset function-only, command does not
     take a housecode, it is programmed simply as:

	heyu preset_level  <level>

     The 'mpreset' command implements the very limited CM11A  support  for  (old
     style) 'preset' commands in uploaded macros.  The allowed preset levels are
     linked with the housecode according to the following table.
	HC     Levels supported
	---    ----------------
	 A	7, 23
	 B	8, 24
	 C	5, 21
	 D	6, 22
	 E	9, 25
	 F     10, 26
	 G     11, 27
	 H     12, 28
	 I     15, 31
	 J     16, 32
	 K     13, 29
	 L     14, 30
	 M	1, 17
	 N	2, 18
	 O	3, 19
	 P	4, 20

     If the 'mpreset' command is executed from the Heyu command line, the levels
     are  restricted  to those shown, for consistancy with its support in an up-
     loaded macro.

     The 'brightb' command (brighten after brightening to 100%)  is  essentially
     useless.	It is implemented as a direct command only because it is a valid
     (although equally useless) command in an uploaded macro.  A design goal for
     Heyu is to have the ability to program any command supported by the  CM11A,
     and to have a direct command corresponding to each macro command.	(The ex-
     istance  of  the  brightb	macro  command is probably just a side effect of
     firmware code shared with the dimb command.)

     The 'address' command sends one or more module addresses to the power  line
     with  no  function code.  It is useful for devices like the various Switch-
     Linc(TM) modules which require a sequence of addresses only, with no inter-
     vening functions, for programming them.  (There does not appear to  be  any
     way  to  have  the  CM11A send only addresses from an uploaded macro in its
     EEPROM.)  Send individual Housecode|Unit addresses to guarantee  the  order
     in which they are sent.  Example:

       heyu address F1 B3 B4

     The  'function'  command sends only the function code for its argument com-
     mand, without any module unit addresses.  The  housecode  is  part  of  the
     function code, so must be specified.
     Example:

       heyu function on A

     The  'kill_all_hc' command sends an 'alloff' command to each housecode A-P.
     Its purpose is to put the user's home system in a	known  state,  with  all
     modules turned off and unaddressed.

     The 'pause' command is useful in scenes or usersyns when it's desireable to
     insert  a	short  delay  between  transmissions  of commands defined in the
     scene/usersyn.  Its parameter is decimal seconds and fractions,  with  mil-
     lisecond  precision  (although  not  necessarily millisecond accuracy).  It
     should not be used to insert long delays as the serial port write lock pre-
     vents other Heyu commands from being executed during the pause interval.

     The 'sleep' command is similar to the 'pause' command except that the  ser-
     ial  port	write  lock is removed during the sleep interval, allowing other
     Heyu commands to be executed during the interval.	This Heyu command may be
     useful for operating systems under which the shell  sleep	command  accepts
     only an integer parameter.

     The  'delay'  and 'rdelay' commands are similar to 'sleep' in that the port
     write lock is removed during the interval, but the time is expressed in in-
     teger minutes 0-240.  The 'delay' command delays for  a  fixed  time.   The
     'rdelay' commands accepts either one or two parameters, [MIN] and MAX.  The
     delay  will  be a random time no shorter than MIN (default 0) and no longer
     than MAX.

     The 'temp_req' command requires as an argument the command used by the par-
     ticular model of remote thermostat/thermometer to initiate an  RCS-compati-
     ble  temperature  report.	 It will then convert the encoded reply from the
     thermometer to a temperature and display it on the command  line.	For  the
     TempLinc(TM) Model 1625 remote thermometer, the command to initiate the re-
     port  is  the  'status'  command.	 For the RCS TX15-B (or newer RCS TXB16)
     Thermostat, the command to initiate the temperature report is the	'preset'
     command to level 1 at unit 5.  Examples:

     For the TempLinc 1625:
	heyu temp_req status A1

     For the RCS TX15-B:
	heyu temp_req preset A5 1

     An  RCS-compatible  remote  thermometer encodes the temperature in the unit
     code and preset Level of an old-style Preset command according to the  fol-
     lowing formula:
	temperature = -60 + (level - 1) + 32 * (unit - 11)
     (valid for units 11 through 16)

     Whether the temperature scale is Celsius or Fahrenheit is determined by how
     the  thermometer  is initially programmed.  The same formula is used in ei-
     ther case.

     Since the unit code of the thermometer module itself is lost, the only  way
     to  distinguish between the reports from multiple thermometers is to assign
     each to a different housecode.

     A (fictitious) unit 0 alias, e.g., 'ALIAS Basement B0', can be  defined  to
     give a name to the location where the temperature is reported.  If the Heyu
     State Engine is running, the decoded temperature will be stored at this ad-
     dress,  where  it can later be recovered with either the 'heyu dimlevel B0'
     or 'heyu rawlevel B0' commands.  Or from within a script launched by  Heyu,
     from  the	value of environment variable X10_B0 or the environment variable
     for the alias for this address, e.g., x10_Basement.

     The 'rcs_req' command functions similarly to the 'temp_req'  command.   (It
     is  in  fact  the same command with a different name and either can be used
     interchangeably.)
     Heyu now has built-in support for interpreting the various  status  reports
     received  from a RCS TX15-B or TXB16 thermostat.  The thermostat can be di-
     rected to transmit these reports with the following commands (for a thermo-
     stat configured for housecode A):
	heyu rcs_req preset A5 1  (temperature)
	heyu rcs_req preset A5 2  (setpoint temperature)
	heyu rcs_req preset A5 3  (system mode)
	heyu rcs_req preset A5 4  (fan mode)
	heyu rcs_req preset A5 5  (setback mode)
	heyu rcs_req preset A5 6  (setback delta temperature)
	heyu rcs_req preset A5 7  (outdoor temperature)
	heyu rcs_req preset A5 8  (heat setpoint temperature)
	heyu rcs_req preset A5 9  (cooling setpoint temperature)

     Note: the temperature value stored at the unit 0 address location	will  be
     the one most recently decoded, whether (room) temperature, setpoint temper-
     ature, setback delta, outdoor, heat setpoint or cooling setpoint.

     See the TX15-B or TXB16 protocol manual for complete details.

     The  'settimer'  command will accept the countdown time parameter as either
     seconds, minutes:seconds, or hours:minutes:seconds.   Minutes  and  seconds
     aren't limited to the range 0-59.
     The  specified countdown time is decremented at each one-second tick of the
     computer's clock, so the accuracy of the countdown time is only +0/-1  sec-
     ond, depending on when between ticks the timer is set.
     When the timer counts down to zero, Heyu will launch a '-timeout' script if
     one  has  been  specified for that timer in the configuration file.  If the
     timer is reset to zero before timeout, then no script is launched.  In  the
     current  implementation,  the  countdown times are not reset to zero when a
     'heyu restart' is executed.

     The 'setrtimer' command sets a countdown time similar to 'settimer'  above,
     but a random countdown time.  It will accept either one or two time parame-
     ters,  "[MIN] MAX".  The coundown time will be a random interval no shorter
     than MIN (default 1 second) amd no longer than MAX.  Both	time  parameters
     may be expressed as hh:mm:ss, mm:ss, or just seconds.

     Advanced Addressing Options:

     Codes are transmitted by the CM11A over the power line in several chunks of
     code - one or more address bytes followed by a function code.

     Each  address  byte  includes  the  housecode and a single unit code.  Each
     function code redundantly includes the housecode plus the	particular  com-
     mand  function.   (For  extended codes, the function chunk of code also in-
     cludes a unit code and the dim level, if any.)  So for commands which apply
     to all units in the housecode (like the foregoing	"lightson"  command)  or
     for extended codes, the address bytes are normally omitted by Heyu.

     For  some purposes it may be necessary to send only the function code for a
     command which normally requires a units address, or include a unit  address
     for  commands  which  don't  require one.	For these purposes the following
     syntax has been implemented:

     Prefixing the Housecode|Unit address with a '-' sign will suppress  sending
     the  address  bytes  (equivalent to using the 'heyu function ...' command).
     While prefixing the Housecode|Unit with a plus '+' sign will force  sending
     the address bytes.  Examples:

	heyu lightson  +B7,12
	heyu off  -G7  (or just -G will do)

     If  a  housecode  is  prefixed  with a '+' sign but not followed by a units
     list, Heyu will use unit 13.  (This is for compatibility  with  X-10's  Ac-
     tiveHome(TM)  software, which always sends an address regardless of whether
     it's needed  or not.)

CM17A COMMANDS
     Heyu version 2 supports commands to actuate a CM17A device connected to the
     serial port to transmit X10 RF signals.  (The CM17A is a transmit-only  de-
     vice;  it	does not receive RF.)  There is no way of detecting the presence
     or absence of a CM17A on the serial port other than by the power line  sig-
     nal  from a transceiver (like an X-10 TM751 or RR501) which receives the RF
     transmission from the CM17A and converts it to a power line signal.   These
     commands  will have no effect if the CM17A is absent other than a short de-
     lay.  All of them may be used in Heyu scenes and usersyns.

     The CM17A commands are merely listed here.  See man page x10cm17a(5) for  a
     complete description.

     freset		      Reset the CM17A device.
     fon	HU	      Transmit RF On
     foff	HU	      Transmit RF Off
     fbright	H[U] <count>  Transmit RF Brights [after On]
     fdim	H[U] <count>  Transmit RF Dims [after On]
     fdimbo	HU <count>    Transmit RF Dims after Off
     flightson	H	      Transmit RF All Lights On
     flightsoff H	      Transmit RF All Lights Off
     falloff	H	      Transmit RF All Units Off
     farb	xx xx <count> Transmit RF Abitrary two hex bytes
     farw	xxxx xxxx ... Transmit RF Arbitrary 16-bit words.
     flux	<count> <post-delay> xxxx xxxx ... (*)

     The  following  "fast" CM17A commands require special timing configuration.
     See man x10cm17a(5).

     ffbright	 H[U] <count>  Transmit RF Brights [after On]
     ffdim	 H[U] <count>  Transmit RF Dims [after On]
     ffdimbo	 HU <count>    Transmit RF Dims after Off
     ffarb	 xx xx <count> Transmit RF Abitrary two hex bytes
     ffarw	 xxxx xxxx ... Transmit RF Arbitrary 16-bit words.
     fflux	 <count> <post-delay> xxxx xxxx ... (*)

     (*) Note: flux and fflux are similar to farw  and	ffarw  except  that  the
     burst  count  and	post-delay  are specified on the command line.	They are
     customized for the LUX17/23 front ends to Heyu but are available  for  gen-
     eral use if convenient.

COMPOUND COMMANDS
     Individual  Heyu  _direct_  commands  may be strung together into a command
     list and executed with a single invocation of Heyu.  To use  this	feature,
     delimit the individual commands with semicolons and enclose the entire com-
     mand list within double quotes so it's passed to Heyu in a single chunk.

EXAMPLES
     heyu turn a5 on
	  Turns X10 module A5 on.

     heyu on a5
	  Same as above

     heyu fon a1
	  Transmits X10 RF On signal via a CM17A device.

     heyu turn b7 dim 8
	  Dims X10 lamp module B7 by 8/22 of its total range.

     heyu "on a1; off b1; dim c7 3"
	  A compound command.

     heyu info
	  Displays CM11A clock time, base housecode and unit status. It also has
	  a  bitmap that shows what it thinks is the state of the X10 modules on
	  the same housecode.

     heyu status B1
	  Returns the status of the 2-way X10 module B1 if the unit replies.

     heyu stop
	  Stops the relay daemon that controls the tty port.  The  monitor  pro-
	  gram	and/or	state  engine daemon will also stop if they are running.
	  Heyu has to be stopped before running a new  version	to  avoid  'text
	  busy' messages.

     heyu setclock
	  Sets the CM11A clock to the current time of day per the MODE specified
	  in  the  user's config file and the record of an uploaded schedule, if
	  any.

     heyu reset
	  Sets the CM11A to the default housecode  specified  in  the  x10config
	  file.

     heyu reset c
	  Sets the CM11A to track events on housecode C

     heyu newbattery
	  Resets  the  CM11A  battery  timer to zero. (There's no way to set the
	  CM11A battery timer to any specific time other than 0.)

     heyu date
	  Displays date in date(1) input format.  The year is  taken  from  your
	  system clock.  Please don't use this to set your computer's clock.

CM10A SUPPORT
     Heyu  provides CM10A support only for Direct commands and applicable Admin-
     istrative commands - e.g., the CM10A does not have a clock, so commands  to
     set  or read the clock don't work.  (The CM10A includes a very limited mem-
     ory for uploaded macros but Heyu does not support this feature.)

     Heyu must be configured to recognize the CM10A - see the  instructions  for
     the  TTY directive in man page x10config(5).  Once Heyu is thus configured,
     the CM10A will be properly initialized at startup or in the event of an  AC
     power interruption.

WEB INTERFACE SUPPORT
     Heyu  endeavors to support web interface development by providing in a cus-
     tomizable format simple information ("web hooks") about it's  configuration
     which  might  otherwise require extensive parsing of the Heyu configuration
     file.

     heyu webhook
	  By itself, displays a summary of the available options.   Further  de-
	  tails and usage examples are provided in the file "README.webhook" in-
	  cluded with the Heyu source distribution.

HEYU CLEANUP
     On  occasion,  generally  due  to initial misconfiguration or system crash,
     there may exist stale files and/or processes which interfere with the oper-
     ation of Heyu.  To clean up these files and/or processes, do the following:

	    Run 'heyu stop'

	    Check for any Heyu processes and kill them.   Under  Linux,  running
	    the command 'ps aux | grep heyu' will display any such processes.

	    Run 'heyu list' to display the LOCKDIR and SPOOLDIR directories com-
	    piled into Heyu.

	    Go	into  the displayed LOCKDIR directory and, if they exist, delete
	    files LCK..ttySxx (where ttySxx are serial ports to which either the
	    CM11A or an RF receiver is connected) and  delete  any  other  files
	    LCK..heyu.*

	    Go	into  the displayed SPOOLDIR directory and delete all files with
	    "heyu" in the filename.

     Heyu should now start and run properly.

EXPERIMENTAL STUFF
     The following commands don't appear in the 'heyu help' menu or regular list
     of commands higher up in this man page.  They may be of  interest	to  some
     for  testing  and hacking the CM11A.  There is no guarantee they won't lock
     up the CM11A or cause it to go into a loop or go up in smoke.  There's also
     no guarantee these commands won't be eliminated in later versions of  Heyu.
     (Let  us know if you find a good use for any of them.)  Those identified by
     "(Admin)" work only at the command line; the others ought to work in scenes
     and usersyns (but not necessarily in macros).  See also the similarly named
     section in man page x10config(5).

     heyu status_emu Hu
	  Execute by a script to emulate the response to a received  Status  Re-
	  quest  by a module which has no status reporting capability, e.g., any
	  1-way module.  If the state of module Hu as recorded by the  Heyu  en-
	  gine is is ON, the command sends a StatusOn signal, otherwise a Statu-
	  sOff	signal.  (There are third-party X10 transmitters, e.g., some ACT
	  transmitters, which send a Status Request  and  always  expect  a  re-
	  sponse.)

     heyu rts_pulser  <msec_on>  <msec_off>  <repetitions>  (Admin)
	  This	command  turns	the  RTS  status  line	On  (high, positive) for
	  <msec_on> milliseconds, turns it Off (low,  negative)  for  <msec_off>
	  milliseconds,  then  repeats	the On/Off cycle for a total of <repeti-
	  tions> cycles.  It is useful for driving an  N-channel  MOSFET  as  an
	  electronic switch.

	  Unless you have a serial connector "Y" adapter, the CM11A will have to
	  be disconnected.

     heyu xpresetramp HU <level> <ramp>
	  The  document  "xtdcode.pdf" on X10's website indicates that the upper
	  two bits of the data byte for the extended preset dim command  control
	  the  rate  at  which	the  lamp  ramps up to its programmed brightness
	  level.  A previous release of this  document	as  "XTC798.DOC"  showed
	  these bits as "don't care".

	  This command allows setting the ramp value in the range 0-3.	Tests of
	  modules  I  own  show  that  the ramp value has no effect for the X-10
	  LM14A and redesigned WS467 modules, whereas the redesigned LM465  mod-
	  ule  immediately  goes  to  full brightness, the same as programming a
	  preset level of 63, for any preset level and any ramp value other than
	  zero.  Modules supporting extended codes from other labels or manufac-
	  turers may or may not support the ramp.

     heyu xgrpoff H G
	  This Extended Group command is supposed  to  turn  Off  all  units  in
	  housecode H which are members of group G.  It is included as an exper-
	  imental command because most modules either don't support it or get it
	  wrong.

	  The redesigned LM465 (module type LM465-1) supports it; the redesigned
	  WS467  (module  type WS467-1) doesn't.  The LM14A and AM14A 2-way mod-
	  ules treat it the same as the 'xgrpexec' command, which is all  wrong.
	  (The	Heyu  module types for all the above attempt to model the actual
	  physical device behavior, whether correct or incorrect.)

     heyu xgrpdim H G

     heyu xgrpbright H G
	  These Extended Group commands are supposed to dim or brighten the mod-
	  ules in a group by one extended level out of 62 (starting at	the  re-
	  sumed  level	if Off).  They are included as experimental commands be-
	  cause most modules don't support them. The  redesigned  LM465  (module
	  type	LM465-1)  does	support them (approximately); the other extended
	  code devices don't.  In actuality, the number of  these  commands  re-
	  quired  to span the full range 1-62 is phase-dependent, observed to be
	  about 78 if triggered on the rising zero crossing (heyu  -tr	...)  or
	  about  53  if  triggered  on the falling zero crossing (heyu -tf ...).
	  These average in the long run to about 65 with random zero crossings

     Group "reference"
	  X-10's Extended Code protocol allows the total number of groups to ex-
	  pand beyond four (although any particular housecode|unit is limited to
	  membership in four) through what they refer to as a "group reference".
	  Heyu implements the group reference as a  number  from  1  through  16
	  which  may be dot-appended to the "absolute" group number for many of,
	  but not all, the extended code group commands.  All groups for a  par-
	  ticular housecode|unit must have the same group reference.

	  Heyu extended group commands listed in this man page or in 'heyu help'
	  showing  the	group  parameter as a capital 'G' may be executed with a
	  group reference.
	  The following examples illustrate assigning the module A1  to  an  ab-
	  solute  group (2) or to a group with a reference (2.10), in both cases
	  at their current brightness level.
	     heyu xgrpadd A1 2
	     heyu xgrpadd A1 2.10

	  Then in the latter example, issuing the command 'heyu xgrpexec A 2.10'
	  will set all members of group 2.10 to the levels stored for that group
	  in the modules' memory.

	  The behavior of X-10 extended code  devices  when  assigning	relative
	  groups varies from device type to device type, and it's anyone's guess
	  whether  X-10  will make unannounced changes.  The behavior listed for
	  the following module types is supported by Heyu:

	  LM14A, AM14A: Assigning a reference to one group automatically changes
	  all group memberships for that housecode|unit to use the  same  refer-
	  ence.

	  WS467-1:  As	above, but the housecode|unit is simultaneously a member
	  of the absolute group.

	  LM465-1: Assigning a group reference removes the  housecode|unit  from
	  membership in all other groups which don't already use the same refer-
	  ence.

	  The command 'heyu show group H' will display the group memberships for
	  all units in Housecode H, absolute and, if assigned, referenced.

	  Note:  There is no provision in the Extended Code protocol for assign-
	  ing a group reference and level with one command  -  the  module  must
	  first  be  brought  to  the  desired	level with the xpreset or dim or
	  bright command and then added to a group at its current level.   As  a
	  consequence,	the 'heyu restore_groups' command can result in a lot of
	  blinking lights when groups with a reference are restored.

     heyu port_line_test (Admin)
	  Test whether the serial port supports the Ring Indicator  (RI)  and/or
	  other  serial input status lines.  This test is run on the port itself
	  - no CM11A - and requires hooking a jumper between the  serial  port's
	  DTR  line  (DB-9 pin 4) and one (or more) of the input status lines to
	  be tested: RI (pin 9), CD (pin 1), DSR (pin 6), CTS (pin 8).

	  Heyu toggles the DTR line and the input line(s) should  replicate  the
	  "SET"  or "clr" state of the DTR line, e.g., for pin 4 jumpered to pin
	  9 there should be displayed:

	  $ heyu port_line_test
	  Jumpered pin	4   to	  9    1    6	 8
	  Status Line: DTR  =>	 RI   CD   DSR	CTS
		       ---	 ---  ---  ---	---
		       clr  =>	 clr  clr  clr	clr
		       SET  =>	 SET  clr  clr	clr
		       clr  =>	 clr  clr  clr	clr
		       SET  =>	 SET  clr  clr	clr

	  Failure of the serial port to support a given input line is  indicated
	  by  the state of the line under test being displayed as constantly clr
	  or constantly SET.  This is the case under Linux  with  a  USB->Serial
	  adapter  containing  an older Prolific chip.	(Whether this is a hard-
	  ware bug or a Linux bug is unknown.)

     heyu ri_disable and heyu ri_enable  (Admin)
	  These commands disable and enable the CM11A feature of  asserting  the
	  Ring	Indicator (RI) serial line just prior to reporting an X10 signal
	  received over the powerline.

	  Some PC motherboards have the capability to power up the  system  when
	  the  RI  signal  is asserted, yet lack the ability in the BIOS to turn
	  off this feature.  To prevent the CM11A from inadvertantly powering up
	  a PC like this, run the heyu ri_disable command as  the  last  command
	  (other than heyu stop) before shutting down the PC.  Then run the heyu
	  ri_enable command after starting up the PC and Heyu again.

	  Note	that  in  the  event  of  an interruption of AC power, the CM11A
	  powerup condition is with the RI assertion  capability  enabled.   And
	  Heyu	uses  the command for enabling the RI line in various places for
	  unrelated reasons.

     heyu ping	(Admin)
	  A quick check to see if the CM11A is responding.  It sends the command
	  to enable the CM11A's serial RI line and waits for the expected echo.

     heyu pausetick
	  Pauses until the system clock rolls over to the  next  second.   Some-
	  times useful in timing commands.

     heyu sendbytes xx xx xx ...
	  Similar to the 'address' command except that the addresses are entered
	  as  hexadecimal  bytes housecode|unitcode (encoded value 0x00 - 0xFF).
	  See the X10 protocol.txt document for the encoding.

     heyu sendtext H "quoted text string"
	  Sends a string of quoted ASCII text  as  addresses  on  the  specified
	  housecode.  Each character in the string is represented by two address
	  bytes  with  their  unit  codes  being the high and low nybbles of the
	  character.  The text is transmitted at the phenominal speed  of  about
	  0.9  characters/second  and  the  PC's resources are tied up while the
	  transmission is taking place.  It works only from the command  line  -
	  not  in  a  macro  and (currently) not in a scene or usersyn.  Perhaps
	  someone will discover a use for  this  otherwise-useless  experimental
	  command. :-)
	  Example:

	     heyu sendtext A "Hello world."

     heyu upload imagefile <filename>  (Admin)
	  Uploads any 1024 byte binary image file to the CM11A's EEPROM, whether
	  created by Heyu or not, including binary image files created by X-10's
	  ActiveHome  software	under  MS  Windows.   Note:  there  won't be any
	  x10record or x10macroxref files created, nor are those existing  files
	  deleted.

     heyu command2cm11a xx xx xx ...
	  Sends  any arbitrary string of hex bytes to the CM11A and attempts the
	  normal software handshake for commands.

     heyu bytes2cm11a xx xx xx ...
	  Sends any arbitrary string of hex bytes to the  CM11A  without  making
	  any attempt at the normal handshaking for commands.

     heyu reserved  (Admin)
	  There's  a  bit in the status update block identified as "reserved" in
	  the X10 protocol.txt and which is normally reset to 0.   This  command
	  sets	it  to	1  to  see  if	it has any effect on anything. (So far I
	  haven't noticed that it does anything at all, but who knows.)

     heyu powerfailtest boot|notboot (Admin)
	  Emulate interruption of AC power to the CM11A.  This allows testing of
	  -powerfail scripts without having to actually  interrupt  power.   The
	  parameter  'boot' or 'notboot' specifies whether to emulate as if Heyu
	  was just started or already running, respectively, when power  to  the
	  CM11A  is  restored.	This command requires that the Heyu state engine
	  daemon be running.  Note that this command does not update  the  CM11A
	  clock  (or  re-initialize  a CM10A) as would be done by the heyu_relay
	  daemon following an actual power interruption.

     options -tr, -tf
	  Many X10 modules are found to respond differently to commands, specif-
	  ically dims and brights, depending on whether the  power  line  signal
	  begins  on  the rising or falling zero crossing.  Which one the signal
	  starts at is random with the CM11A and most other transmitters.   With
	  additional  hardware,  these experimental options will allow transmis-
	  sion of (direct) commands to synchronize with only the rising (-tr) or
	  only the falling (-tf) zero crossing.  Fast timing is  required  so  a
	  timing  loop will have to be calibrated by running 'heyu utility cali-
	  brate'.
	  Example:
	    heyu -tr dim A1 10

	  The additional hardware required is to connect the secondary of a 4 to
	  8 VAC (RMS) transformer between the Signal Ground (DB9 pin 5) and Car-
	  rier Detect (DB9 pin 1) pins of the serial port to which the CM11A  is
	  connected.   (Neither the CM11A nor the CM17A normally use the Carrier
	  Detect pin.)	The polarity of the AC voltage on the CD pin must be in-
	  phase with the AC power line for the -tr and -tf options to match  the
	  rising and falling zero-crossings respectively, otherwise they'll work
	  backwards.

	  An adapter between the CM11A cable and serial port will be required to
	  make	this  connection  -  I use a male/female pair of DB9 solder-type
	  connectors with corresponding pins joined with  3/4"	lengths  of  bus
	  bar,	and  connect to the SG and CD pin bus bars with Radio Shack hook
	  clips.

	  Note: prudence dictates using an inexpensive serial port  add-on  card
	  for  experiments  like  this	to reduce the risk to motherboard compo-
	  nents.  The output voltage  of  a  transformer  may  be  substantially
	  higher than its rating (at rated current) when supplying only the very
	  low  current to the serial port pin.	Although the RS232 specification
	  allows for a voltage as high as 25 Volts, PC serial ports are normally
	  operated between +/- 12 Volts and it would be unwise	to  exceed  that
	  level,  and certainly no higher than 15 Volts peak.  (12 Volts peak ->
	  8.49 Volts RMS.)

     heyu tdim HU <level>, heyu tbright HU <level>
	  These commands operate as if the dim or bright  commands  were  issued
	  with the -tr option.	They are now deprecated.

ENVIRONMENT
     X10CONFIG	-  Points  to  a fully qualified file name of your configuration
     file, if located elsewhere than in one of the standard places. See  x10con-
     fig(5) for more information on its makeup.
     HEYUSUB  -  Optionally specifies an additional subdirectory level under the
     standard places where the configuration file will be found, i.e.,
	$HOME/.heyu/$HEYUSUB/
	/etc/heyu/$HEYUSUB/
     X10SCHED - Points to a fully qualified file  name	of  your  schedule  file
     (timers  and  macros),  if  located  elsewhere  than in one of the standard
     places.  See x10sched(5) for more information on its layout.
     ASIF_DATE - Instruct Heyu to process the data in your schedule file  as  of
     the  specified date ( format yyyymmdd ) instead of the current system date.
     (Its primary use is with 'heyu upload check' - to examine the details  when
     something	suspicious  is brought to light with the 'heyu upload croncheck'
     command.)

FILES
      $HOME/.heyu/x10config - Heyu configuration file when in user's home direc-
     tory.
      SYSBASEDIR/x10.conf - Heyu configuration file when in  system-wide  direc-
     tory.
      Included in the same directory as the configuration file are:
	x10state - module on/off/dim state file (binary).
	x10.sched - default filename for schedule of uploaded timers and macros.
	x10record - record of the uploaded schedule parameters.
	x10macroxref - addresses of uploaded macros.
	x10image - binary image of the uploaded schedule.
      LOCKDIR/LCK..<tty> - lock file for serial port.
      LOCKDIR/LCK..heyu.relay.<tty> - lock file for relay process.
      LOCKDIR/LCK..heyu.engine.<tty> - lock file for state engine process.
      LOCKDIR/LCK..heyu.write.<tty>  - lock file for processes that write to the
     CM11A
      SPOOLDIR/heyu.out.<tty> - fifo file for relay process.

     Where in the above <tty> is a suffix representing the serial port to  which
     the CM11A is connected, e.g.,
      /dev/ttyS0 -> ttyS0
      /dev/usb/ttyUSB0 -> ttyUSB0  (implies a USB-Serial adapter)

     ('heyu  list'  will  display the LOCKDIR, SPOOLDIR, and SYSBASEDIR compiled
     into Heyu for your operating system.)

BUGS
     Occasionally the interface will not accept the first command after a reboot
     of the CM11A or the computer.

     Heyu does not always handle well an X10 command  received	over  the  power
     line when it's in the middle of sending out a command.

AUTHORS
     Re-written to use the CM11A interface by Daniel B. Suthers (dbs@tanj.com).
     Originally  written  (Known  as  X10) by Larry Campbell (maynard!campbell).
     System V port, ID file, improved display formats, and other cleanup by John
     Chmielewski (rogue!jlc).  Module aliasing additions by Paul  Fox  (pgf@fox-
     harp.boston.ma.us)
     Enhanced  capability for uploaded schedules, state functions, and execution
     of scripts by Charles Sullivan (cwsulliv01@heyu.org)

TRADEMARKS
     Heyu is a trademark of Daniel B. Suthers.	X10, CM11A, and  ActiveHome  are
     trademarks  of  X-10  (USA)  Inc.	 TempLinc,  SwitchLinc, and LampLinc are
     trademarks of Smarthome, Inc.  W800RF32A is a  trademark  of  WGL	&  Asso-
     ciates.

SEE ALSO
     http://www.heyu.org
     date(1),  x10config(5), x10sched(5), x10scripts(5), x10cm17a(5), x10aux(5),
     x10rfxsensors(5)

				      local				 HEYU(1)