Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
IPGEN(1)		     General Commands Manual			IPGEN(1)

NAME
     ipgen -- L2 and L3 traffic generator and interactive benchmarking utility

SYNOPSIS
     ipgen [-V vlanid] [-P] -R rx-ifname,gateway-addr,[my-addr[/prefix]]
	   [-V vlanid] [-P] -T tx-ifname,gateway-addr,[my-addr[/prefix]] [-H hz]
	   [-n npkt] [--ipg] [--burst] [-S script] [-L logfile] [-s packet-size]
	   [-p packet-per-second] [-t duration] [-f] [-v] [-X] [-XX] [-XXX]
	   [--tcp] [--udp] [--fragment] [--l1-bps] [--l2-bps] [--allnet]
	   [--saddr begin[-end]] [--daddr begin[-end]] [--sport begin[-end]]
	   [--dport begin[-end]] [--flowlist file] [--flowsort] [--flowdump]
	   [-F nflow] [--rfc2544] [--rfc2544-interval seconds]
	   [--rfc2544-no-early-finish] [--rfc2544-output-json file]
	   [--rfc2544-pktsize size,[size, ...]]
	   [--rfc2544-pps-resolution percent] [--rfc2544-slowstart]
	   [--rfc2544-tolerable-error-rate percent]
	   [--rfc2544-trial-duration seconds]
	   [--rfc2544-warming-duration seconds] [--nocurses] [-D file] [-d]
	   [--fail-if-dropped]

DESCRIPTION
     The  ipgen utility is an L2 and L3 traffic generator with the following de-
     sign goals:

     -	 Wire-speed support based on Netmap API on FreeBSD or XDP on Linux,
     -	 Benchmarking capability with multiple packet flows,
     -	 Interative user interface to show various statistics, and
     -	 RFC 2544 benchmarking methodology.

EXIT STATUS
     The ipgen utility exits 0 on success, and >0 if an error occurs.

EXAMPLES
     The following example does a loopback test assuming igb1 with  MAC  address
     00:11:22:33:44:55	and  igb2  with  66:77:88:99:aa:bb  are on a box running
     ipgen and the two ports  are  directrly  connected  by  an  Ethernet  cable
     (back-to-back connection defined in Section 3.1, RFC 1242).  Note that each
     gateway address must be specified to the MAC address of another endpoint:

	   ipgen -T igb1,66:77:88:99:aa:bb -R igb2,00:11:22:33:44:55

     If  the  two Ethernet cables are connected to igb1 and igb2 and the another
     endpoint is a bridge box, such as an Ethernet hub or switch to form a  sin-
     gle L2 segment, the same command performs an L2 forwarding performance test
     of the bridge box.

     The  following  example does an L3 forwarding performance test.  A box run-
     ning  ipgen  has  igb1  with  an  address	192.18.0.1/24  and   igb2   with
     192.18.1.1/24,  and  two Ethernet cables are connected to another box (DUT:
     Device Under Test) that can forward TCP/IP packets, such as a router.  This
     assumes that the DUT has 192.18.0.2/24 and 192.18.1.2/24 on the  interfaces
     connected to each segment:

	   ipgen -T igb1,192.18.0.2,192.18.0.1/24 -R igb2,192.18.1.2,192.18.1.1/24

     The  flag	--rfc2544 enables RFC 2544 benchmarking report.  When specified,
     ipgen shows throughput (Section 3.17 in  RFC  1242)  and  frame  loss  rate
     (Section  3.6  in	RFC  1242) of a DUT throughout the entire range of input
     data rates and frame sizes after the test finishes.  The following  example
     shows  RFC  2544  benchmarking report for the same testing setup for the L2
     forwarding example:

	   ipgen -T igb1,66:77:88:99:aa:bb -R igb2,00:11:22:33:44:55 --rfc2544

SEE ALSO
     netmap(4)

     S. Bradner, Benchmarking Terminology for Network  Interconnection	Devices,
     RFC 1242, July 1991.

     S.  Bradner  and J. McQuaid, Benchmarking Methodology for Network Intercon-
     nect Devices, RFC 2544, March 1999.

AUTHORS
     The ipgen utility was designed and implemented by Ryo Shimizu and is  main-
     tained by Internet Initiative Japan Inc. .

     This manual page was written by Hiroki Sato <hrs@FreeBSD.org>.

FreeBSD ports 15.quarterly	  May 13, 2024				IPGEN(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=ipgen&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help