NAME
     ipmi-config - IPMI configuration file details

DESCRIPTION
     Before  many  IPMI  tools can be used over a network, a machine's Baseboard
     Management Controller (BMC) must be configured. The  configuration  can  be
     quite  daunting  for  those  who  do not know much about IPMI. This manpage
     hopes to provide enough information on BMC configuration so  that	you  can
     configure the BMC for your system. When appropriate, typical BMC configura-
     tions will be suggested.

     The  following is an example configuration file partially generated by run-
     ning the --checkout option with the ipmi-config(8) command. This configura-
     tion comes from the core category of configuration  values  (the  default).
     This  example  configuration  should be sufficient for most users after the
     appropriate local IP and MAC addresses are input. Following  this	example,
     separate  sections  of  this manpage will discuss the different sections of
     the configuration file in more detail with explanations of how the BMC  can
     be configured for different environments.

     Note  that  many options may or may not be available on your particular ma-
     chine. For example, Serial-Over-Lan (SOL) is available only on IPMI 2.0 ma-
     chines. Therefore, if you are looking to configure  an  IPMI  1.5	machine,
     many  of the SOL or IPMI 2.0 related options will be be unavailable to you.
     The number of configurable users may also vary for your particular machine.

     The below configuration file and most of this manpage assume  the	user  is
     interested  in  configuring a BMC for use with IPMI over LAN.  Various con-
     figuration options from ipmi-config(8) have been left out	or  skipped  be-
     cause  it	is considered unnecessary.  Future versions of this manpage will
     try to include more information.

	  Section User1
	   ## Give username
	   ## Username NULL
	   ## Give password or leave it blank to clear password
	   Password mypassword
	   ## Possible values: Yes/No or blank to not set
	   Enable_User Yes
	   ## Possible values: Yes/No
	   Lan_Enable_Ipmi_Msgs Yes
	   ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	   Lan_Privilege_Limit Administrator
	     ## Possible values: 0-17, 0 is unlimited; May be reset to 0 if not specified
	     ## Lan_Session_Limit
	   ## Possible values: Yes/No
	   SOL_Payload_Access Yes
	  EndSection
	  Section User2
	   ## Give username
	   Username user2
	   ## Give password or leave it blank to clear password
	   Password userpass
	   ## Possible values: Yes/No or blank to not set
	   Enable_User No
	   ## Possible values: Yes/No
	   Lan_Enable_Ipmi_Msgs No
	   ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	   Lan_Privilege_Limit No_Access
	     ## Possible values: 0-17, 0 is unlimited; May be reset to 0 if not specified
	     ## Lan_Session_Limit
	     ## Possible values: Yes/No
	     SOL_Payload_Access No
	  EndSection
	  Section Lan_Channel
	   ## Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
	   Volatile_Access_Mode Always_Available
	   ## Possible values: Yes/No
	   Volatile_Enable_User_Level_Auth Yes
	   ## Possible values: Yes/No
	   Volatile_Enable_Per_Message_Auth Yes
	   ## Possible values: Yes/No
	   Volatile_Enable_Pef_Alerting No
	   ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	   Volatile_Channel_Privilege_Limit Administrator
	   ## Possible values: Disabled/Pre_Boot_Only/Always_Available/Shared
	   Non_Volatile_Access_Mode Always_Available
	   ## Possible values: Yes/No
	   Non_Volatile_Enable_User_Level_Auth Yes
	   ## Possible values: Yes/No
	   Non_Volatile_Enable_Per_Message_Auth Yes
	   ## Possible values: Yes/No
	   Non_Volatile_Enable_Pef_Alerting No
	   ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary/No_Access
	   Non_Volatile_Channel_Privilege_Limit Administrator
	  EndSection
	  Section Lan_Conf
	   ## Possible values: Unspecified/Static/Use_DHCP/Use_BIOS/Use_Others
	   Ip_Address_Source Static
	   ## Give valid IP Address
	   Ip_Address 192.168.1.100
	   ## Give valid MAC Address
	   Mac_Address 00:0E:0E:FF:AA:12
	   ## Give valid Subnet mask
	   Subnet_Mask 255.255.255.0
	   ## Give valid IP Address
	   Default_Gateway_Ip_Address 192.168.1.1
	   ## Give valid MAC Address
	   Default_Gateway_Mac_Address 00:0E:0E:FF:AA:18
	   ## Give valid IP Address
	   Backup_Gateway_Ip_Address 192.168.1.2
	   ## Give valid MAC Address
	   Backup_Gateway_Mac_Address 00:0E:0E:FF:AA:15
	  EndSection
	  Section Lan_Conf_Auth
	   ## Possible values: Yes/No
	   Callback_Enable_Auth_Type_None No
	   ## Possible values: Yes/No
	   Callback_Enable_Auth_Type_Md2 No
	   ## Possible values: Yes/No
	   Callback_Enable_Auth_Type_Md5 No
	   ## Possible values: Yes/No
	   Callback_Enable_Auth_Type_Straight_Password No
	   ## Possible values: Yes/No
	   Callback_Enable_Auth_Type_Oem_Proprietary No
	   ## Possible values: Yes/No
	   User_Enable_Auth_Type_None No
	   ## Possible values: Yes/No
	   User_Enable_Auth_Type_Md2 Yes
	   ## Possible values: Yes/No
	   User_Enable_Auth_Type_Md5 Yes
	   ## Possible values: Yes/No
	   User_Enable_Auth_Type_Straight_Password No
	   ## Possible values: Yes/No
	   User_Enable_Auth_Type_Oem_Proprietary No
	   ## Possible values: Yes/No
	   Operator_Enable_Auth_Type_None No
	   ## Possible values: Yes/No
	   Operator_Enable_Auth_Type_Md2 Yes
	   ## Possible values: Yes/No
	   Operator_Enable_Auth_Type_Md5 Yes
	   ## Possible values: Yes/No
	   Operator_Enable_Auth_Type_Straight_Password No
	   ## Possible values: Yes/No
	   Operator_Enable_Auth_Type_Oem_Proprietary No
	   ## Possible values: Yes/No
	   Admin_Enable_Auth_Type_None No
	   ## Possible values: Yes/No
	   Admin_Enable_Auth_Type_Md2 Yes
	   ## Possible values: Yes/No
	   Admin_Enable_Auth_Type_Md5 Yes
	   ## Possible values: Yes/No
	   Admin_Enable_Auth_Type_Straight_Password No
	   ## Possible values: Yes/No
	   Admin_Enable_Auth_Type_Oem_Proprietary No
	   ## Possible values: Yes/No
	   Oem_Enable_Auth_Type_None No
	   ## Possible values: Yes/No
	   Oem_Enable_Auth_Type_Md2 No
	   ## Possible values: Yes/No
	   Oem_Enable_Auth_Type_Md5 No
	   ## Possible values: Yes/No
	   Oem_Enable_Auth_Type_Straight_Password No
	   ## Possible values: Yes/No
	   Oem_Enable_Auth_Type_Oem_Proprietary No
	  EndSection
	  Section Lan_Conf_Security_Keys
	     ## Give string or blank to clear. Max 20 chars
	     K_G
	  EndSection
	  Section Lan_Conf_Misc
	   ## Possible values: Yes/No
	   Enable_Gratuitous_Arps Yes
	   ## Possible values: Yes/No
	   Enable_Arp_Response No
	   ## Give valid number. Intervals are 500 ms.
	   Gratuitous_Arp_Interval 4
	  EndSection
	  Section Rmcpplus_Conf_Privilege
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_0 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_1 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_2 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_3 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_4 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_5 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_6 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_7 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_8 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_9 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_10 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_11 Unused
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_12 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_13 Administrator
	   ## Possible values: Unused/User/Operator/Administrator/OEM_Proprietary
	   Maximum_Privilege_Cipher_Suite_Id_14 Administrator
	  EndSection
	  Section SOL_Conf
	   ## Possible values: Yes/No
	   Enable_SOL Yes
	   ## Possible values: Callback/User/Operator/Administrator/OEM_Proprietary
	   SOL_Privilege_Level Administrator
	   ## Possible values: Yes/No
	   Force_SOL_Payload_Authentication Yes
	   ## Possible values: Yes/No
	   Force_SOL_Payload_Encryption Yes
	   ## Give a valid integer. Each unit is 5ms
	   Character_Accumulate_Interval 50
	   ## Give a valid number
	   Character_Send_Threshold 100
	   ## Give a valid integer
	   SOL_Retry_Count 5
	   ## Give a valid integer. Interval unit is 10ms
	   SOL_Retry_Interval 50
	   ## Possible values: Serial/9600/19200/38400/57600/115200
	   Non_Volatile_Bit_Rate 115200
	   ## Possible values: Serial/9600/19200/38400/57600/115200
	   Volatile_Bit_Rate 115200
	  EndSection

Section User1, User2, ...
     The User sections of the BMC configuration file are for username configura-
     tion for IPMI over LAN communication. The number of users available  to  be
     configured on your system will vary by manufacturer.  With the exception of
     the Username for User1, all sections are identical.

     The  username(s)  you wish to configure the BMC with are defined with User-
     name. The first username under Section User1 is typically the NULL username
     and cannot be modified. The password for the username can be specified with
     Password. It can be left empty to define a NULL  password.  Each  user  you
     wish  to  enable  must be enabled through the Enable_User configuration op-
     tion. It is recommended that all usernames have non-NULL  passwords  or  be
     disabled for security reasons.

     Lan_Enable_Ipmi_Msgs  is used to enable or disable IPMI over LAN access for
     the user. This should be set to "Yes" to allow IPMI over LAN tools to work.

     Lan_Privilege_Limit specifies the maximum privilege level limit the user is
     allowed. Different IPMI commands have different privilege restrictions. For
     example, determining the power status of a machine only requires the "User"
     privilege level. However, power cycling requires the "Operator"  privilege.
     Typically,  you will want to assign atleast one user with a privilege limit
     of "Administrator" so that all system functions are  available  to  atleast
     one user via IPMI over LAN.

     Lan_Session_Limit	specifies  the	number of simultaneous IPMI sessions al-
     lowed for the user. Most users will wish to set this to "0" to allow unlim-
     ited simultaneous IPMI sessions. This field is considered optional by  IPMI
     standards,  and  may  result in errors when attempting to configure it to a
     non-zero value. If errors to occur, setting the value back to 0 should  re-
     solve problems.

     SOL_Payload_Access  specifies  if	a  particular user is allowed to connect
     with Serial-Over-LAN (SOL). This should be set to "Yes" to allow this user-
     name to use SOL.

     The example configuration above disables "User2" but  enables  the  default
     "NULL" (i.e. anonymous) user. Many IPMI tools (both open-source and vendor)
     do  not  allow the user to input a username and assume the NULL username by
     default. If the tools you are interested in using allow usernames to be in-
     put, then it is recommended that one of the non-NULL usernames  be  enabled
     and the NULL username disabled for security reasons. It is recommended that
     you  disable the NULL username in section User1, so that users are required
     to specify a username for IPMI over LAN communication.

     Some motherboards may require a Username to be configured	prior  to  other
     fields being read/written. If this is the case, those fields will be set to
     <username-not-set-yet>.

Section Lan_Channel
     The Lan_Channel section configures a variety of IPMI over LAN configuration
     parameters.  Both	Volatile  and  Non_Volatile  configurations  can be set.
     Volatile configurations are immediately configured onto the  BMC  and  will
     have  immediate  effect on the system. Non_Volatile configurations are only
     available after the next system reset. Generally,	both  the  Volatile  and
     Non_Volatile should be configured identically.

     The  Access_Mode  parameter configures the availability of IPMI over LAN on
     the system. Typically this should be set to  "Always_Available"  to  enable
     IPMI over LAN.

     The  Privilege_Limit  sets the maximum privilege any user of the system can
     have when performing IPMI over LAN. This should be set to the maximum priv-
     ilege level configured to a username. Typically, this should be set to "Ad-
     ministrator".

     Typically User_Level_Auth and Per_Message_Auth should be set to  "Yes"  for
     additional  security.  Disabling  User_Level_Auth	allows "User" privileged
     IPMI commands to be executed  without  authentication.  Disabling	Per_Mes-
     sage_Auth allows fewer individual IPMI messages to require authentication.

Section Lan_Conf
     Those  familiar  with setting up networks should find most of the fields in
     this section self explanatory. The example BMC configuration  above  illus-
     trates  the  setup  of  a static IP address. The field IP_Address_Source is
     configured with "Static". The IP address, subnet mask, and gateway  IP  ad-
     dresses  of  the  machine	are respectively configured with the IP_Address,
     Subnet_Mask,  Default_Gateway_Ip_Address,	 and   Backup_Gateway_Ip_Address
     fields.  The  respective  MAC addresses for the IP addresses are configured
     under Mac_Address, Default_Gateway_Mac_Address, and  Backup_Gateway_Mac_Ad-
     dress.

     It  is  not  required  to setup the BMC IP_Address to be the same P_Address
     used by your operating system for that network interface. However,  if  you
     choose  to use a different address, an alternate ARP configuration may need
     to be setup.

     To instead setup your BMC network information via DHCP,  the  field  IP_Ad-
     dress_Source should be configured with "Use_DHCP".

     It  is recommended that static IP addresses be configured for address reso-
     lution reasons. See Lan_Conf_Misc below for a more detailed explanation.

Section Lan_Conf_Auth
     This section determines what types of  password  authentication  mechanisms
     are allowed for users at different privilege levels under the IPMI 1.5 pro-
     tocol. The currently supported authentication methods for IPMI 1.5 are None
     (no  username/password  required), Straight_Password (passwords are sent in
     the clear), MD2 (passwords are MD2 hashed),  and  MD5  (passwords	are  MD5
     hashed).	Different usernames at different privilege levels may be allowed
     to authenticate differently through  this	configuration.	For  example,  a
     username  with  "User"  privileges  may  be  allowed to authenticate with a
     straight password, but a username with "Administrator"  privileges  may  be
     allowed only authenticate with MD5.

     The above example configuration supports MD2 and MD5 authentication for all
     users  at the "User", "Operator", and "Administrator" privilege levels. All
     authentication mechanisms have been disabled for the  "Callback"  privilege
     level.

     Generally	speaking, you do not want to allow any user to authenticate with
     None or Straight_Password for security reasons.  MD2 and  MD5  are  digital
     signature algorithms that can minimally encrypt passwords. If you have cho-
     sen  to  support the NULL username (enabled User1) and NULL passwords (NULL
     password for User1), you will have to enable the None authentication fields
     above to allow users to connect via None.

Section Lan_Conf_Security_Keys
     This section supports configuration of the IPMI 2.0 (including Serial-over-
     LAN) K_g key. If your machine does not support IPMI 2.0,  this  field  will
     not be configurable.

     The key is used for two-key authentication in IPMI 2.0. In most tools, when
     doing IPMI 2.0, the K_g can be optionally specified. It is not required for
     IPMI 2.0 operation.

     In  the above example, we have elected to leave this field blank so the K_g
     key is not used.

Section Lan_Conf_Misc
     This section lists  miscellaneous	IPMI  over  LAN  configuration	options.
     These  are  optional IPMI configuration options that are not implemented on
     all BMCs.

     Normally, a client cannot resolve the ethernet MAC address without the  re-
     mote operating system running. However, IPMI over LAN would not work when a
     machine  is  powered  off or if the IP address used by the operating system
     for that network interface differs from the BMC IP Address. One way to work
     around this is through gratuitous ARPs.  Gratuitous ARPs  are  ARP  packets
     generated	by  the  BMC  and sent out to advertise the BMC's IP and MAC ad-
     dress.  Other machines on the network can store this information  in  their
     local  ARP  cache	for  later IP/hostname resolution. This would allow IPMI
     over LAN to work when the remote machine is powered off. The  Enable_Gratu-
     itous_Arps  option allows you to enable or disable this feature. The Gratu-
     itous_Arp_Interval option allows you to configure the  frequency  at  which
     gratuitous ARPs are sent onto the network.

     Instead  of  gratuitous ARPs some BMCs are able to respond to ARP requests,
     even when powered off. If offerred, this feature can be enabled through the
     Enable_Arp_Response option.

     Generally speaking, turning on gratuitous ARPs is acceptable.  However,  it
     will  increase  traffic  on your network.	If you are using IPMI on a large
     cluster, the gratuitous ARPs may easily flood your network. They should  be
     tuned  to	occur  less  frequently or disabled. If disabled, the remote ma-
     chine's MAC address should be permanently stored in  the  local  ARP  cache
     through arp(8).

     See  bmc-watchdog(8)  for	a method which allows gratuitous ARPs to be dis-
     abled when the operating system is running, but enabled when the system  is
     down.

Section Rmcpplus_Conf_Privilege
     This section supports configuration of the IPMI 2.0 (including Serial-over-
     LAN)  cipher  suite  IDs.	If  your  machine does not support IPMI 2.0, the
     fields will not be configurable.

     Each cipher suite ID describes a combination  of  an  authentication  algo-
     rithm, integrity algorithm, and encryption algorithm for IPMI 2.0.  The au-
     thentication  algorithm  is  used for user authentication with the BMC. The
     integrity algorithm is used for generating signatures on IPMI packets.  The
     confidentiality algorithm is used for encrypting data. The configuration in
     this  section  enables  certain cipher suite IDs to be enabled or disabled,
     and the maximum privilege level a username can authenticate with.

     The following table shows the cipher suite ID to algorithms mapping:

     0 - Authentication Algorithm = None; Integrity Algorithm = None;  Confiden-
     tiality Algorithm = None

     1	- Authentication Algorithm = HMAC-SHA1; Integrity Algorithm = None; Con-
     fidentiality Algorithm = None

     2 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm	=  HMAC-
     SHA1-96; Confidentiality Algorithm = None

     3	-  Authentication  Algorithm  =  HMAC-SHA1;  Integrity Algorithm = HMAC-
     SHA1-96; Confidentiality Algorithm = AES-CBC-128

     4 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm	=  HMAC-
     SHA1-96; Confidentiality Algorithm = xRC4-128

     5	-  Authentication  Algorithm  =  HMAC-SHA1;  Integrity Algorithm = HMAC-
     SHA1-96; Confidentiality Algorithm = xRC4-40

     6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None; Confi-
     dentiality Algorithm = None

     7 - Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm	=  HMAC-
     MD5-128; Confidentiality Algorithm = None

     8	-  Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm = HMAC-
     MD5-128; Confidentiality Algorithm = AES-CBC-128

     9 - Authentication  Algorithm  =  HMAC-MD5;  Integrity  Algorithm	=  HMAC-
     MD5-128; Confidentiality Algorithm = xRC4-128

     10  -  Authentication  Algorithm  =  HMAC-MD5;  Integrity Algorithm = HMAC-
     MD5-128; Confidentiality Algorithm = xRC4-40

     11 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =	MD5-128;
     Confidentiality Algorithm = None

     12  -  Authentication  Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128;
     Confidentiality Algorithm = AES-CBC-128

     13 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =	MD5-128;
     Confidentiality Algorithm = xRC4-128

     14  -  Authentication  Algorithm = HMAC-MD5; Integrity Algorithm = MD5-128;
     Confidentiality Algorithm = xRC4-40

     Generally speaking, HMAC-SHA1 based algorithms are stronger than  HMAC-MD5,
     which are better than MD5-128 algorithms. AES-CBC-128 confidentiality algo-
     rithms are stronger than xRC4-128 algorithms, which are better than xRC4-40
     algorithms.  Cipher  suite  ID 3 is therefore typically considered the most
     secure. Some users may wish to set cipher suite ID 3 to a	privilege  level
     and disable all remaining cipher suite IDs.

     The  above example configuration has decided to allow any user with "Admin-
     istrator" privileges use any Cipher Suite algorithm suite which requires an
     authentication, integrity, and confidentiality algorithm.	 Typically,  the
     maximum  privilege level configured to a username should be set for atleast
     one cipher suite ID. Typically, this is the "Administrator" privilege.

     A number of cipher suite IDs are optionally implemented, so  the  available
     cipher suite IDs available your system may vary.

Section SOL_Conf
     This  section  is	for  setting  up  Serial-Over-Lan (SOL) and will only be
     available for configuration on those machines. SOL can be enabled with  the
     Enable_SOL  field. The minimum privilege level required for connecting with
     SOL is specified by SOL_Privilege_Level.  This should be set to the maximum
     privilege level configured to a username that has SOL  enabled.  Typically,
     this is the "Administrator" privilege. Authentication and Encryption can be
     forced   or  not  using  the  fields  Force_SOL_Payload_Authentication  and
     Force_SOL_Payload_Encryption respectively. It is recommended that these  be
     set  on. However, forced authentication and/or encryption support depend on
     the cipher suite IDs supported.

     The     Character_Accumulate_Interval,	 Character_Send_Threshold      ,
     SOL_Retry_Count  and , SOL_Retry_Interval options are used to set SOL char-
     acter output speeds. Character_Accumulate_Interval determines how often se-
     rial data should be regularly sent and  Character_Send_Threshold  indicates
     the  character  count  that  if  passed, will force serial data to be sent.
     SOL_Retry_Count indicates how many times packets must be  retransmitted  if
     acknowledgements are not received. SOL_Retry_Interval indicates the timeout
     interval.	Generally,  the  manufacturer recommended numbers will be suffi-
     cient. However, you may wish to experiment with these values for faster SOL
     throughput.

     The Non_Volatile_Bit_Rate and Volatile_Bit_Rate determine the baudrate  the
     BMC  should use. This should match the baudrate set in the BIOS and operat-
     ing system, such as agetty(8).  Generally speaking, both the  Volatile  and
     Non_Volatile options should be set identically.

     In  addition to enabling SOL in this section, individual users most also be
     capable of connecting with SOL. See the section Section User1,  User2,  ...
     above for details.

REPORTING BUGS
     Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

SEE ALSO
     freeipmi(7), bmc-watchdog(8), ipmi-config(8), agetty(8)

     http://www.gnu.org/software/freeipmi/

ipmi-config 1.6.18		   2026-06-02		     ipmi-config.conf(5)