NAME
     ipmi-oem - IPMI OEM utility

SYNOPSIS
     ipmi-oem [OPTION...] <OEMID> <OEMCOMMAND> [OEMOPTION...]

DESCRIPTION
     Ipmi-oem  is  used to execute OEM specific IPMI commands. It is intended to
     provide a better user interface for OEM specific IPMI commands rather  than
     using ipmi-raw(8).

     Please see SUPPORTED OEM IDS and COMMANDS below for a list of supported OEM
     specific  IPMI commands. A list of supported OEM specific commands may also
     be generated using the --list option.

     There are no guarantees that the below OEM commands will work on  any  par-
     ticular  motherboard.  OEM  extensions  may  or may not exist on particular
     hardware revisions and/or firmware revisions of  motherboards.  The  exten-
     sions may or may not function for other lines of motherboards from the same
     manufacturer.

     Listed  below  are  general  IPMI	options,  tool specific options, trouble
     shooting information, workaround information, examples, and  known  issues.
     For a general introduction to FreeIPMI please see freeipmi(7).

GENERAL OPTIONS
     The  following  options are general options for configuring IPMI communica-
     tion and executing general tool commands.

     -D IPMIDRIVER, --driver-type=IPMIDRIVER
	    Specify the driver type to use instead of doing an	auto  selection.
	    The currently available outofband drivers are LAN and LAN_2_0, which
	    perform  IPMI 1.5 and IPMI 2.0 respectively. The currently available
	    inband drivers are KCS, SSIF, OPENIPMI, SUNBMC, and INTELDCMI.

     --disable-auto-probe
	    Do not probe in-band IPMI devices for default settings.

     --driver-address=DRIVER-ADDRESS
	    Specify the in-band driver address to be used instead of the  probed
	    value.  DRIVER-ADDRESS  should be prefixed with "0x" for a hex value
	    and '0' for an octal value.

     --driver-device=DEVICE
	    Specify the in-band driver device path to be  used	instead  of  the
	    probed path.

     --register-spacing=REGISTER-SPACING
	    Specify  the  in-band  driver register spacing instead of the probed
	    value. Argument is in bytes (i.e. 32bit register spacing = 4)

     --target-channel-number=CHANNEL-NUMBER
	    Specify the in-band driver target channel number to  send  IPMI  re-
	    quests to.

     --target-slave-address=SLAVE-ADDRESS
	    Specify the in-band driver target slave number to send IPMI requests
	    to.

     -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMI-
     HOST2[:PORT],...
	    Specify  the  remote host(s) to communicate with. Multiple hostnames
	    may be separated by comma or may be specified in a range format; see
	    HOSTRANGED SUPPORT below. An optional port	can  be  specified  with
	    each  host, which may be useful in port forwarding or similar situa-
	    tions.  If specifying an IPv6 address and port, use the format  [AD-
	    DRESS]:PORT.

     -u USERNAME, --username=USERNAME
	    Specify  the  username  to	use  when authenticating with the remote
	    host.  If not specified, a null (i.e.  anonymous)  username  is  as-
	    sumed.  The  required user privilege will depend on the oem commands
	    executed.

     -p PASSWORD, --password=PASSWORD
	    Specify the password to use when  authenticationg  with  the  remote
	    host.   If	not specified, a null password is assumed. Maximum pass-
	    word length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

     -P, --password-prompt
	    Prompt for password to avoid possibility of listing  it  in  process
	    lists.

     -k K_G, --k-g=K_G
	    Specify  the  K_g BMC key to use when authenticating with the remote
	    host for IPMI 2.0. If not specified, a null key is assumed. To input
	    the key in hexadecimal form, prefix the string with '0x'. E.g.,  the
	    key  'abc'	can  be  entered with the either the string 'abc' or the
	    string '0x616263'

     -K, --k-g-prompt
	    Prompt for k-g to avoid possibility of listing it in process lists.

     --session-timeout=MILLISECONDS
	    Specify the session timeout in milliseconds. Defaults to 20000  mil-
	    liseconds (20 seconds) if not specified.

     --retransmission-timeout=MILLISECONDS
	    Specify  the packet retransmission timeout in milliseconds. Defaults
	    to 1000 milliseconds (1 second) if not specified. The retransmission
	    timeout cannot be larger than the session timeout.

     -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
	    Specify the IPMI 1.5  authentication  type	to  use.  The  currently
	    available authentication types are NONE, STRAIGHT_PASSWORD_KEY, MD2,
	    and MD5. Defaults to MD5 if not specified.

     -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
	    Specify  the  IPMI	2.0  cipher suite ID to use. The Cipher Suite ID
	    identifies a set of authentication, integrity,  and  confidentiality
	    algorithms to use for IPMI 2.0 communication. The authentication al-
	    gorithm  identifies  the algorithm to use for session setup, the in-
	    tegrity algorithm identifies the algorithm to use for session packet
	    signatures, and the confidentiality algorithm identifies  the  algo-
	    rithm  to  use for payload encryption. Defaults to cipher suite ID 3
	    if not specified. The following cipher suite ids are currently  sup-
	    ported:

	    0  -  Authentication  Algorithm  = None; Integrity Algorithm = None;
	    Confidentiality Algorithm = None

	    1 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm  =
	    None; Confidentiality Algorithm = None

	    2  -  Authentication  Algorithm  =	HMAC-SHA1; Integrity Algorithm =
	    HMAC-SHA1-96; Confidentiality Algorithm = None

	    3 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm  =
	    HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

	    6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None;
	    Confidentiality Algorithm = None

	    7 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = None

	    8 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    11	-  Authentication  Algorithm  =  HMAC-MD5; Integrity Algorithm =
	    MD5-128; Confidentiality Algorithm = None

	    12 - Authentication Algorithm  =  HMAC-MD5;  Integrity  Algorithm  =
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    15	-  Authentication Algorithm = HMAC-SHA256; Integrity Algorithm =
	    None; Confidentiality Algorithm = None

	    16 - Authentication Algorithm = HMAC-SHA256; Integrity  Algorithm  =
	    HMAC_SHA256_128; Confidentiality Algorithm = None

	    17	-  Authentication Algorithm = HMAC-SHA256; Integrity Algorithm =
	    HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

     -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	    Specify the privilege level to  be	used.  The  currently  available
	    privilege levels are USER, OPERATOR, and ADMIN. Defaults to ADMIN if
	    not specified.

     --config-file=FILE
	    Specify an alternate configuration file.

     -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	    Specify   workarounds   to	 vendor   compliance   issues.	Multiple
	    workarounds can be specified separated by commas. A special  command
	    line flag of "none", will indicate no workarounds (may be useful for
	    overriding configured defaults). See WORKAROUNDS below for a list of
	    available workarounds.

     --debug
	    Turn on debugging.

     -?, --help
	    Output a help list and exit.

     --usage
	    Output a usage message and exit.

     -V, --version
	    Output the program version and exit.

SDR CACHE OPTIONS
     This  tool  requires  access  to the sensor data repository (SDR) cache for
     general operation. By default, SDR data will be downloaded  and  cached  on
     the local machine. The following options apply to the SDR cache.

     --flush-cache
	    Flush  a  cached  version of the sensor data repository (SDR) cache.
	    The SDR is typically cached for faster subsequent  access.	However,
	    it	may  need to be flushed and re-generated if the SDR has been up-
	    dated on a system.

     --quiet-cache
	    Do not output information about cache creation/deletion. May be use-
	    ful in scripting.

     --sdr-cache-recreate
	    If the SDR cache is out of date or invalid,  automatically	recreate
	    the  sensor  data  repository (SDR) cache. This option may be useful
	    for scripting purposes.

     --sdr-cache-file=FILE
	    Specify a specific sensor data repository (SDR)  cache  file  to  be
	    stored  or read from. If this option is used when multiple hosts are
	    specified, the same SDR cache file will be used for all hosts.

     --sdr-cache-directory=DIRECTORY
	    Specify an alternate directory  for  sensor  data  repository  (SDR)
	    caches  to be stored or read from. Defaults to the home directory if
	    not specified.

TIME OPTIONS
     By IPMI definition, all IPMI times and timestamps are stored in  localtime.
     However,  in  many  situations, the timestamps will not be stored in local-
     time. Whether or not a system truly  stored  the  timestamps  in  localtime
     varies on many factors, such as the vendor, BIOS, and operating system.

     The  following  options will allow the user to adjust the interpretation of
     the stored timestamps and how they should be output.

     --utc-to-localtime
	    Assume all times are reported in UTC time and convert  the	time  to
	    localtime before being output.

     --localtime-to-utc
	    Convert all localtime timestamps to UTC before being output.

     --utc-offset=SECONDS
	    Specify  a specific UTC offset in seconds to be added to timestamps.
	    Value can range from -86400 to 86400 seconds. Defaults to 0.

HOSTRANGED OPTIONS
     The following options manipulate hostranged output. See HOSTRANGED  SUPPORT
     below for additional information on hostranges.

     -B, --buffer-output
	    Buffer  hostranged output. For each node, buffer standard output un-
	    til the node has completed its IPMI operation. When specifying  this
	    option,  data  may appear to output slower to the user since the the
	    entire IPMI operation must complete before any data can  be  output.
	    See HOSTRANGED SUPPORT below for additional information.

     -C, --consolidate-output
	    Consolidate  hostranged  output.  The  complete standard output from
	    every node specified will be consolidated so that nodes with identi-
	    cal output are not output twice. A header will list those nodes with
	    the consolidated output. When this option is  specified,  no  output
	    can be seen until the IPMI operations to all nodes has completed. If
	    the user breaks out of the program early, all currently consolidated
	    output  will  be dumped. See HOSTRANGED SUPPORT below for additional
	    information.

     -F NUM, --fanout=NUM
	    Specify multiple host fanout. A "sliding window" (or  fanout)  algo-
	    rithm  is  used for parallel IPMI communication so that slower nodes
	    or timed out nodes will not impede parallel communication. The maxi-
	    mum number of threads available at the same time is limited  by  the
	    fanout. The default is 64.

     -E, --eliminate
	    Eliminate  hosts  determined  as undetected by ipmidetect.	This at-
	    tempts to remove the common issue of hostranged execution timing out
	    due to several nodes being removed from service in a large	cluster.
	    The  ipmidetectd  daemon  must  be running on the node executing the
	    command.

     --always-prefix
	    Always prefix output, even if only one host is specified or communi-
	    cating in-band. This option is primarily useful for  scripting  pur-
	    poses. Option will be ignored if specified with the -C option.

IPMI-OEM OPTIONS
     The following options are specific to ipmi-oem.

     -L, --list
	    List supported OEM IDs and Commands.

     -v, --verbose
	    Output  verbose  information.  Additional output will depend on spe-
	    cific OEM ID and OEM COMMANDS specified.

SUPPORTED OEM IDS and COMMANDS
     The currently supported OEM IDs and COMMANDs are listed below. The  special
     OEM  ID  of list may be passed into the list all supported OEM IDs and Com-
     mands. The special OEM command list may be passed to any  OEM  ID	to  list
     commands supported by that OEM ID.

     Dell

	    get-system-info KEY
		   This OEM command can retrieve the motherboard system informa-
		   tion.   Valid  keys	are  guid, asset-tag, service-tag, chas-
		   sis-service-tag, chassis-related-service-tag, board-revision,
		   platform-model-name,    blade-slot-info,	system-revision,
		   idrac-info,	  idrac-ipv4-url,   idrac-gui-webserver-control,
		   cmc-info, cmc-ipv4-url, cmc-ipv6-info, cmc-ipv6-url,  mac-ad-
		   dresses.  Command  confirmed  to work on Dell Poweredge 2900,
		   2950, R610, R710, R720, M600, M610, M610X,  M910,  and  R905.
		   However,  individual  system  information  options may not be
		   readable or available on every system.

	    get-nic-selection
		   This OEM command will determine the current NIC selection for
		   IPMI as dedicated, shared, shared w/  failover  to  NIC2,  or
		   shared  w/  failover to all. Dedicated indicates IPMI is only
		   available on an expansion  card,  shared  indicates	IPMI  is
		   available  on NIC1, shared w/ failover to NIC2 indicates IPMI
		   is available on NIC1 w/ failover to NIC2 on	NIC1's	failure,
		   and	shared w/ failover to all indicates IPMI is available on
		   NIC1 w/ failover to all other NICs in the event of NIC  fail-
		   ure.  Command confirmed to work on Dell Poweredge 2900, 2950,
		   R610, R710, and R905.

	    set-nic-section dedi-
	    cated|shared|shared_failover_nic2|shared_failover_all
		   This OEM command will set the current NIC selection to  dedi-
		   cated,  shared, shared_failover_nic2, or shared_failover_all.
		   (See get-nic-selection above for description on  inputs.)  On
		   older  Poweredge  systems, shared_failover_nic2 may have been
		   documented as just failover. Command  confirmed  to	work  on
		   Dell Poweredge 2900, 2950, R610, R710, and R905.

	    get-nic-selection-failover
		   This OEM command will determine the current NIC selection for
		   IPMI  and the failover NIC. Command confirmed to work on Dell
		   Poweredge R720 (Dell 12G Poweredge systems).

	    set-nic-section-failover dedicated|lom1|lom2|lom3|lom4
	    none|lom1|lom2|lom3|lom4|all
		   This OEM command will set the current NIC selection for  IPMI
		   and	the failover NIC. The first option sets the IPMI NIC and
		   the second option the failover NIC. Command confirmed to work
		   on Dell Poweredge R720 (Dell 12G Poweredge systems).

	    get-active-lom-status [v1|v2]
		   This OEM command will get the current NIC being used for  out
		   of band management and possibly additional information. Users
		   may	specify  if  version  1  or  version 2 of this extension
		   should be executed. If no version is specified, version 1  is
		   executed. Version 1 of this command confirmed to work on Dell
		   Poweredge R610 and R710 (Dell 11G Poweredge systems). Version
		   2  of  this	command confirmed to work on Dell Poweredge R720
		   (Dell 12G Poweredge systems).

	    get-ssh-config
		   This OEM command will get the current  SSH  configuration  on
		   the	IPMI  card.  Command confirmed to work on Dell Poweredge
		   R610 and R710 (Dell 11G Poweredge systems).

	    set-ssh-config KEY=VALUE ...
		   This OEM command will set the current  SSH  configuration  on
		   the	IPMI  card.  The  possible  keys  and values are ssh=en-
		   able|disable, idletimeout=seconds, and portnumber=num. Multi-
		   ple key=value pairs may be specified. If no	key=value  pairs
		   are specified, available pairs are output. Some fields may be
		   read-only on specific Poweredge systems. Command confirmed to
		   work on Dell Poweredge R610 and R710 (Dell 11G Poweredge sys-
		   tems).

	    get-telnet-config
		   This OEM command will get the current telnet configuration on
		   the	IPMI  card.  Command confirmed to work on Dell Poweredge
		   R610 and R710 (Dell 11G Poweredge systems).

	    set-telnet-config KEY=VALUE ...
		   This OEM command will set the current Telnet configuration on
		   the IPMI card. The possible keys and  values  are  telnet=en-
		   able|disable,   sessiontimeout=seconds,  portnumber=num,  and
		   7fls=enable|disable. Multiple key=value pairs may  be  speci-
		   fied.   If  no key=value pairs are specified, available pairs
		   are output. Some fields may be  read-only  on  specific  Pow-
		   eredge  systems.  Command confirmed to work on Dell Poweredge
		   R610 and R710 (Dell 11G Poweredge systems).

	    get-web-server-config
		   This OEM command will get the current web  server  configura-
		   tion on the IPMI card. Command confirmed to work on Dell Pow-
		   eredge R610 and R710 (Dell 11G Poweredge systems).

	    set-web-server-config KEY=VALUE ...
		   This  OEM  command will set the current Web Server configura-
		   tion on the IPMI card. The possible keys and values are  web-
		   server=enable|disable,  sessiontimeout=seconds,  httpportnum-
		   ber=num, and httpsportnumber=num.  Multiple	key=value  pairs
		   may be specified. If no key=value pairs are specified, avail-
		   able  pairs	are output. Some fields may be read-only on spe-
		   cific Poweredge systems. Command confirmed to  work	on  Dell
		   Poweredge R610 and R710 (Dell 11G Poweredge systems).

	    get-active-directory-config
		   This  OEM  command will get the current active directory con-
		   figuration on the IPMI card. Command  confirmed  to	work  on
		   Dell Poweredge R610 and R710 (Dell 11G Poweredge systems).

	    set-active-directory-config
		   This  OEM  command will set the current Web Server configura-
		   tion on the IPMI card. The possible keys and values	are  ac-
		   tivedirectory=enable|disable,    timeout=seconds,	type=ex-
		   tended|standard, sso=enable|disable,  and  certificatevalida-
		   tion=enable|disable.  If  no  key=value  pairs are specified,
		   available pairs are output. Some fields may be  read-only  on
		   specific Poweredge systems. Command confirmed to work on Dell
		   Poweredge R610 and R710 (Dell 11G Poweredge systems).

	    reset-to-defaults
		   This OEM command will reset the BMC configuration back to de-
		   fault  values.  The command will spin until the reset is con-
		   firmed to be complete. Command confirmed to work on Dell Pow-
		   eredge R610 and R710 (Dell 11G Poweredge systems).

	    get-power-consumption-data
		   This OEM command can retrieve power consumption data. Command
		   confirmed to work on Dell Poweredge R610, R710,  R905,  M610,
		   M610x, and M910.

	    reset-power-consumption-data cumulative|peak
		   This  OEM command can reset the cumulative or peak power con-
		   sumption data (viewed via  get-power-consumption-data).  Com-
		   mand  confirmed  to	work on Dell Poweredge R610, R710, R905,
		   M610, M610x, and M910.

	    power-supply-info
		   This OEM command can read and output power supply ratings and
		   other information. This OEM command requires  access  to  the
		   SDR.  Command confirmed to work on Dell Poweredge R610, R710,
		   and M610.

	    get-instantaneous-power-consumption-data power_supply_instance
		   This OEM command can  read  instantaneous  power  consumption
		   data.  If  a  power supply instance number is specified, only
		   data for that instance will be gathered.  Otherwise,  collec-
		   tive power consumption will be gathered. Command confirmed to
		   work on Dell Poweredge R610, R710, M610, M610x, and M910.

	    get-power-head-room
		   This  OEM command can read power head room. Command confirmed
		   to work on Dell Poweredge R610 and R710 (Dell  11G  Poweredge
		   systems).

	    get-power-consumption-statistics average|max|min
		   This OEM command can read average, max, or min power consump-
		   tion  history.  Command  confirmed  to work on Dell Poweredge
		   R610, R710, M610, M610x, and M910.

	    get-power-capacity
		   This OEM command can read the current power capacity. Command
		   confirmed to work on Dell Poweredge R610, R710, M610,  M610x,
		   and M910.

	    set-power-capacity power-capacity
		   This OEM command can write the current power capacity (speci-
		   fied  in  Watts). Command confirmed to work on Dell Poweredge
		   R610 and R710 (Dell 11G Poweredge systems).

	    get-power-capacity-status
		   This OEM command can determine if the current power	capacity
		   is  enabled	or  disabled.  Command confirmed to work on Dell
		   Poweredge R610, R710, M610, M610x, and M910.

	    set-power-capacity-status enable|disable
		   This OEM command can configure the current power capacity  to
		   be  enabled	or  disabled.  Command confirmed to work on Dell
		   Poweredge R610 and R710 (Dell 11G Poweredge systems).

	    get-chassis-identify-status
		   This OEM command will retrieve the current  chassis	identify
		   (i.e.  LED)	status.  Command  confirmed to work on Dell Pow-
		   eredge 2900, 2950, R610, R710, R905, M600, M610,  M610x,  and
		   M910.

	    power-monitoring-over-interval interval system-
	    power|cpu1|cpu2|cpu3|cpu4|memory1|memory2|memory3|memory4|dri-
	    ves|fans|pciecards|gpucables
		   This  OEM command will retrieve power consumption information
		   from a specified subsystem for a specified interval time.  If
		   the	interval  is  between 30 and 900s, the average, minimum,
		   and maximum power value can also be retrieved. If the  inter-
		   val	is between 5 and 30 seconds, only the average power con-
		   sumption can be returned. See power-monitoring-interval-range
		   below to determine legal intervals for each	subsystem.  Com-
		   mand  confirmed to work on Dell Poweredge R720 (Dell 12G Pow-
		   eredge systems).

	    power-monitoring-interval-range systempower|cpu1|cpu2|cpu3|cpu4|mem-
	    ory1|memory2|memory3|memory4|drives|fans|pciecards|gpucables
		   This OEM command will retrieve the monitoring intervals for a
		   specified subsystem. Command confirmed to work on  Dell  Pow-
		   eredge R720 (Dell 12G Poweredge systems).

	    get-last-post-code
		   This  OEM  command will retrieve the last POST code and error
		   string for it. Command confirmed to work  on  Dell  Poweredge
		   R720.

	    slot-power-toggle slot-number
		   This  OEM command will perform a power toggle on a PCIe slot.
		   The PCIe slot number can range from 1  to  16.  Command  con-
		   firmed to work on Dell Poweredge C410x.

	    slot-power-control platform-model on|off|status slot-number
		   This  OEM  command  will  perform a power control action on a
		   PCIe slot.  This OEM extension is  tied  very  closely  to  a
		   platform, so a supported platform must be specified. The cur-
		   rently supported platform-model options are C410x. The on ac-
		   tion  powers on a slot, off powers off a slot, and status re-
		   turns if the current power is on or off. If the current power
		   status is on, an on action does nothing.  Similarly,  if  the
		   current  power status is off, an off action does nothing. The
		   on, off, and status slot power actions are not native and are
		   emulated through a  combination  of	a  power  toggle  (using
		   slot-power-toggle  above)  and  the reading of PCIe slot watt
		   sensors. The PCIe slot number can range from 1 to 16. Command
		   confirmed to work on Dell Poweredge C410x.

	    get-port-map
		   This OEM command will retrieve the current iPASS  mapping  to
		   PCIe  controllers/slots.  Command  confirmed  to work on Dell
		   Poweredge C410x.

	    set-port-map jumper|bmc ipass-mapping 1:2|1:4|1:8
		   This OEM command will set  an  iPass  mapping  to  PCIe  con-
		   trollers/slots.   jumper or bmc must be specified to indicate
		   if iPass mappings will be controlled via jumpers on the  sys-
		   tem	or  via  a  BMC/IPMI. In order for reconfiguration to be
		   done via ipmi-oem, the user must select bmc.  The  ipass-map-
		   ping  determines which iPass ports will be mapped.  1:2, 1:4,
		   and 1:8 determine the mapping that should be set. See details
		   below for specific platforms. Command confirmed  to	work  on
		   Dell Poweredge C410x.

		   For the Dell Poweredge C410x, the ipass-mapping ranges from 1
		   to  4. 1 refers to iPass 1 and 5, 2 to 2 and 6, 3 to 3 and 7,
		   and 4 to 4 and 8. For the platform C410x, PCIe slots 1, 2, 3,
		   4, 13, 14, 15, and 16 are attached to iPass 1, 2, 3,  and  4.
		   PCIe  slots	5,  6,	7,  8, 9, 10, 11, and 12 are attached to
		   iPass 5, 6, 7, and 8. For example, if 1:2 is set on	mapping-
		   number 1, PCIe slots 1 and 15 will be assigned to iPass 1 and
		   slots 2 and 16 will be assigned to iPass 5. if 1:4 is chosen,
		   PCIe  slots	1, 2, 15, and 16 will be assigned to iPass 1 and
		   iPass 5 will not be used.

     Fujitsu

	    get-power-on-source
		   This OEM command will return the reason for the  most  recent
		   Power On.  Command confirmed to work on Fujitsu RX100 S5. .TP
		   .B get-power-off-source This OEM command will return the rea-
		   son	for the most recent Power Off. Command confirmed to work
		   on Fujitsu RX100 S5.

	    command will return the connection and/or status of remote storage.
	    connection_number currently supports a range of  0-1.  Command  con-
	    firmed  to	work  on Fujitsu RX100 S5. .TP .B get-system-status This
	    OEM command will return the current system status. Command confirmed
	    to work on Fujitsu RX100 S5.  .TP  .B  get-eeprom-version-info  eep-
	    rom_number This OEM command will return the current version info for
	    various  hardware  elements, including firmware, SDR, and boot revi-
	    sion. eeprom_number currently supports a range of 0-1.  Command con-
	    firmed to work on Fujitsu RX100 S5.

	    get-identify-led
	    This OEM command will get the current identify LED	status.  Command
	    confirmed to work on Fujitsu RX100 S5.

	    set-identify-led on|off
	    This  OEM  command will set the current identify LED status. Command
	    confirmed to work on Fujitsu RX100 S5.

	    get-error-led
	    This OEM command will get the current error LED status. Command con-
	    firmed to work on Fujitsu RX100 S5.

	    get-sel-entry-long-text sel_record_id
	    This OEM command will retrieve the Fujitsu specific string interpre-
	    tation of a SEL record. This command may be useful for  interpreting
	    Fujitsu  OEM  hex  codes  found in the SEL. A specific SEL record ID
	    must be  specified.  Please  see  ipmi-sel(8),  for  retrieving  SEL
	    records. Command confirmed to work on Fujitsu RX100 S5.

     GIGABYTE

	    This OEM command will determine the current NIC mode as dedicated,
	    shared,  or  failover. Dedicated indicates IPMI is only available on
	    the dedicated management port. Shared indicates IPMI is also  avail-
	    able  on  one of the primary ethernet ports. Failover indicates IPMI
	    is dedicated but can failover to another if the primary port  fails.
	    Command confirmed to work on GIGABYTE MD90-FS0-ZB.

	    set-nic-mode dedicated|shared|failover
	    This OEM command will set the current NIC mode to dedicated, shared,
	    or	failover.  (See  get-nic-mode above for description on dedicated
	    vs. shared vs failover modes.) Command confirmed to work on GIGABYTE
	    MD90-FS0-ZB.

	    get-bmc-services
	    This OEM command will display the enable/disable state of  BMC  ser-
	    vices   besides   IPMI.   Command  confirmed  to  work  on	GIGABYTE
	    MD90-FS0-ZB.

	    set-bmc-services enable|disable ssh|http|rpcbind|svrloc|https|avo-
	    cenkvm|wbem-http|wbem-https
	    This OEM command will enable or disable BMC services  besides  IPMI.
	    Command confirmed to work on GIGABYTE MD90-FS0-ZB.

     IBM

	    get-led
		   This  OEM  command  will get the current LED status. This OEM
		   command requires access to the SDR. Command confirmed to work
		   on IBM x3755.

     Intel

	    get-smtp-config [channel-number]
		   This OEM command will get the current SMTP  configuration  on
		   the	IPMI card. By default, configuration for every LAN chan-
		   nel will be output.	If a channel-number is	specified,  only
		   that  specific channel number's configuration will be output.
		   Command confirmed to work on Intel S5500WB (Penguin Computing
		   Relion 700) and Intel S2600JF (Appro 512X).

	    set-smtp-config [channel-number] KEY=VALUE...
		   This OEM command will set the current SMTP  configuration  on
		   the IPMI card. By default, configuration will be done for all
		   LAN	channels.   If	a channel-number is specified, only that
		   specific channel number's configuration will  be  configured.
		   The	 possible   keys  and  values  are  smtp=enable|disable,
		   smtpserveraddress=ipaddress,  smtpusername=string,  userpass-
		   word=string, emailaddress=string, subject=string, messagecon-
		   tent=string,    senderemailaddress=string,	 and   smtphost-
		   name=string.  Multiple key=value pairs may be  specified.  If
		   no key=value pairs are specified, available pairs are output.
		   Command confirmed to work on Intel S5500WB (Penguin Computing
		   Relion 700) and Intel S2600JF (Appro 512X).

	    get-power-restore-delay
		   This  OEM command will retrieve the power on delay. The power
		   on delay is a delay that occurs whenever the BMC turns on the
		   system according to the Power Restore Policy setting. It does
		   not take effect otherwise (i.e. power button or Chassis  Con-
		   trol).  Command  confirmed  to  work  on Intel S2600JF (Appro
		   512X).

	    set-power-restore-delay seconds
		   This  OEM  command  will  set  the  power  on   delay.   (See
		   get-power-restore-delay  above  for	description on power re-
		   store delay). Command confirmed to work on Intel S2600JF (Ap-
		   pro 512X).

	    get-bmc-services
		   This OEM command will get the current status of BMC	services
		   such  as  ssh, http, rmcp, and kvm. Command confirmed to work
		   on Intel S2600WT2.

	    set-bmc-services enable|disable ssh|http|rmcp|kvm
		   This OEM command will enable or disable BMC services  besides
		   IPMI.   Note that http refers to both http and https. Command
		   confirmed to work on Intel S2600WT2.

	    restore-configuration
		   This OEM command will restore BMC configuration  values  back
		   to default values. The command will spin until the restore is
		   confirmed to be complete. Command configured to work on Intel
		   S5500WB (Penguin Computing Relion 700) and Intel S2600JF (Ap-
		   pro	512X). After running this command, the BMC must be reset
		   to return it to functioning status. This may be  accomplished
		   by executing a cold-reset with .B bmc-device(8).

     IntelNM (Intel Node Manager)

     The following OEM commands operate on Intel chipsets with Node Manager sup-
     port. They all require access to the SDR. They may work on multiple vendors
     motherboards.

	    get-node-manager-statistics mode=globalpower|globaltemp|globalthrot-
	    tling|globalvolumetricairflow|globaltempairflow|globalchassis-
	    power|policypower|policytrigger|policythrottling|hostunhandle-
	    drequests|hostresponsetime|cputhrottling|memorythrottling|hostcomm-
	    failure [domainid=platform|cpu|memory|highpowerio] [policyid=num]
		   This OEM command will output Intel Node Manager statistics. A
		   mode  indicating  statistics to output must be specified. The
		   user may optionally specify a domainid or policyid,	although
		   certain  mode  options  may	require it. domainid defaults to
		   platform. Command confirmed to work on Intel S5500WB (Penguin
		   Computing  Relion  700),  Inventec  5441/5442  (Dell   Xanadu
		   II/III),  Quanta  S99Q (Dell FS12-TY), Quanta QSSC-S4R (Appro
		   GB812X-CN), Supermicro X9DRi-F, Intel S2600JF (Appro 512X).

	    reset-node-manager-statistics [mode=global|policy|hostunhandle-
	    drequests|hostresponsetime|cputhrottling|memorythrottling|hostcomm-
	    failure]
		   [domainid=platform|cpu|memory|highpowerio]	  [policyid=num]
		   This  OEM  command  will reset Intel Node Manager statistics.
		   The mode will indicate the statistics to be reset.  The  user
		   may	optionally  specify a domainid or policyid. domainid de-
		   faults to platform. If a mode is not specified, it  will  de-
		   fault to global or policy, depending on whether or not a pol-
		   icyid  is  specified.  Command  confirmed  to  work	on Intel
		   S5500WB (Penguin Computing Relion  700),  Inventec  5441/5442
		   (Dell  Xanadu  II/III),  Quanta  S99Q  (Dell FS12-TY), Quanta
		   QSSC-S4R (Appro GB812X-CN), Supermicro X9DRi-F, Intel S2600JF
		   (Appro 512X).

	    get-node-manager-capabilities [domainid=platform|cpu|memory|highpow-
	    erio] [policytrigger=none|inlettemperaturelimitpolicytrigger|miss-
	    ingpowerreadingtimeout|timeafterplatformresettrigger|boottimepolicy]
	    [policytype=powercontrol] [policypowerdomain=primary|secondary]
		   This OEM command will output the current capabilities of  the
		   Intel  Node	manager.  The  user may optionally specify a do-
		   mainid,  policytrigger,  policytype,  or   policypowerdomain.
		   Note  that policypowerdomain is only applicabale to domain id
		   platform. If any particular option is not specified, all per-
		   mutations of the remaining options will be used in an attempt
		   to output all capabilities of the system. If the verbose  op-
		   tion  is  set,  additional  error  messages will be output as
		   valid policies are being searched for. Command  confirmed  to
		   work on Intel S2600JF (Appro 512X).

	    node-manager-policy-control <enable|disable> [domainid=plat-
	    form|cpu|memory|highpowerio] [policyid=num]
		   This  OEM  command will enable or disable the current global,
		   domain, or policies used by the Intel Node Manager. If no do-
		   mainid is specified, then the Node Manager will be enabled or
		   globally disabled.  If a domainid is specified, only that do-
		   main will be enabled or disabled. If both a domainid and pol-
		   icyid are specified, only that specific policy within the do-
		   main will be specified. This OEM command will be required  to
		   enable  or disable policies before many of the commands below
		   can be used for configuration or use.  Command  confirmed  to
		   work on Intel S2600JF (Appro 512X).

	    get-node-manager-policy [domainid=platform|cpu|memory|highpowerio]
	    [policyid=num]
		   This OEM command will get the current node manager policy. If
		   no domainid is specified, all policies for all domain IDs and
		   policy  Ids	will be attempted to be output. If a domainid is
		   specified but a policyid is not, all policies within a domain
		   will be attempted to be output. If the verbose option is set,
		   additional error messages will be output  as  valid	policies
		   are	being  searched  for. Command confirmed to work on Intel
		   S2600JF (Appro 512X).

	    set-node-manager-policy domainid=platform|cpu|memory|highpowerio
	    policyid=num policytrigger=none|inlettemperaturelimitpolicytrig-
	    ger|missingpowerreadingtimeout|timeafterplatformresettrigger|boot-
	    timepolicy policytargetlimit=num [platformbootingmode=perfor-
	    mance|power] correctiontimelimit=ms statisticsreportingperiod=sec-
	    onds policystorage=persistent|volatile [policytriggerlimit=num]
	    [policystate=enable|disable] [policyexceptionaction=alert|shutdown]
	    [aggressivepowercorrection=automatic|notaggressive|aggressive] [pol-
	    icypowerdomain=primary|secondary]
		   This OEM command will add or modify an  indicated  policy  ID
		   from  the  domain  ID. Most of the fields above are required,
		   although they can be listed in any order. By default any cre-
		   ated/modified policy will be enabled,  however  this  can  be
		   overridden  by  policystate.   policyexceptionaction  may  be
		   specified multiple times to configure multiple actions or can
		   be skipped to configure no actions.	When  the  policytrigger
		   is  configured  as none, the trigger that will lead to excep-
		   tion actions is the value specified by the policytargetlimit.
		   When the policytrigger is inlettemperaturelimitpolicytrigger,
		   missingpowerreadingtimeout, or timeafterplatformresettrigger,
		   the trigger that will lead to exception actions is the  value
		   specified by policytriggerlimit.  When the fIpolicytrigger is
		   boottimepolicy,  a power profile will simply be maintained by
		   the value specified by policytargetlimit. aggressivepowercor-
		   rection defaults to automatic. It can only be set  to  notag-
		   gressive  or  aggressive  if the domainid is platform or cpu.
		   policystorage determines if the policy being  configured  can
		   survive  across resets of the machine. The units of the poli-
		   cytargetlimit depends on the policytrigger selected.  If  the
		   policytrigger is none, inlettemperaturelimitpolicytrigger, or
		   timeafterplatformresettrigger, the units will be in Watts. If
		   the	policytrigger  is  missingpowerreadingtimeout, the units
		   will be in percent, where 100 means	maximum  throttling.  If
		   the	policytrigger  is boottimepolicy, the units is number of
		   CPUs. In addition, platformbootingmode must be set to perfor-
		   mance or power to indicate optimization mode.  policytrigger-
		   limit is sometimes required, given the input  to  policytrig-
		   ger.  The  units of the policytriggerlimit will depend on the
		   policytrigger selected. If the policytrigger is inlettempera-
		   turelimitpolicytrigger, the units of policytriggerlimit  will
		   be  in  Celsius. If the policytrigger is missingpowerreading-
		   timeout or timeafterplatformresettrigger, the units	will  be
		   in  seconds.  If the policytrigger is none or boottimepolicy,
		   the policytriggerlimit is ignored  internally  by  the  Intel
		   Node  Manager and need not be specified.. Typically configur-
		   ing it to 0 is more than sufficient. The  correctiontimelimit
		   specifies  the time the Node Manager must take corrective ac-
		   tions to bring back the system within  limits  before  taking
		   the actions specified in policyexceptionaction. statisticsre-
		   portingperiod  is  the  number of seconds that measured power
		   will be averaged for  reporting.   Please  see  get-node-man-
		   ager-policy to determine proper ranges for policytargetlimit,
		   correctiontimelimit,  policytriggerlimit,  and  statisticsre-
		   portingperiod.  If domainid is configured as  platform,  user
		   may optionally set policypowerdomain to primary or secondary.
		   Otherwise  policypowerdomain  will  be ignored.  Command con-
		   firmed to work on Intel S2600JF (Appro 512X).

	    remove-node-manager-policy domainid=platform|cpu|memory|highpowerio
	    policyid=num
		   This OEM command will remove the indicated policy ID from the
		   domain ID. Both the domainid and policyid are required.  Com-
		   mand confirmed to work on Intel S2600JF (Appro 512X).

	    get-node-manager-policy-alert-thresholds [domainid=platform|cpu|mem-
	    ory|highpowerio] [policyid=num]
		   This OEM command will get the current alert thresholds. If no
		   domainid  is  specified,  all alert thresholds for domain IDs
		   and policy Ids will be attempted to be output. If a	domainid
		   is  specified  but  a  policyid  is not, all alert thresholds
		   within a domain will be attempted to be output. The units  of
		   the	thresholds  will depend on the configuration of the cur-
		   rent policy. If the verbose option is set,  additional  error
		   messages  will be output as valid policies are being searched
		   for. Command confirmed to work on Intel S2600JF (Appro 512X).

	    set-node-manager-policy-alert-thresholds domainid=platform|cpu|mem-
	    ory|highpowerio policyid=num [threshold1=num] [threshold2=num]
	    [threshold3=num]
		   This OEM command will set the alert thresholds  for	a  given
		   domain ID and policy ID. Up to three thresholds can be speci-
		   fied, The units of the thresholds will depend on the configu-
		   ration  of  the current policy.  Command confirmed to work on
		   Intel S2600JF (Appro 512X).

	    get-node-manager-policy-suspend-periods [domainid=platform|cpu|mem-
	    ory|highpowerio] [policyid=num]
		   This OEM command will get the current policy suspend periods.
		   Suspend periods will temporarily disable Intel  Node  Manager
		   policies  at  configured  times. If no domainid is specified,
		   all suspend periods for domain IDs and policy Ids will be at-
		   tempted to be output.  If a domainid is specified but a poli-
		   cyid is not, all suspend periods within a domain will be  at-
		   tempted  to	be  output.  If the verbose option is set, addi-
		   tional error messages will be output as  valid  policies  are
		   being  searched  for. Suspend start and stop times are output
		   in 24 hour format. Command confirmed to work on Intel S2600JF
		   (Appro 512X).

	    set-node-manager-policy-suspend-periods domainid=platform|cpu|mem-
	    ory|highpowerio policyid=num suspendperiodstart1=time suspendperiod-
	    stop1=time suspendperiodrepeat1=monday|tuesday|wednesday|thurs-
	    day|friday|saturday|sunday ...
		   This OEM command will set the policy suspend  periods  for  a
		   policy.   Suspend periods will temporarily disable Intel Node
		   Manager policies at configured times. Up to 5 suspend periods
		   can be specified by suspendperiodstartX,  suspendperiodstopX,
		   suspendperiodrepeatX.  suspendperiodstart  and suspendperiod-
		   stop specify the start and stop time  since	midnight  for  a
		   suspend  period. The time should be specified in 24 hour for-
		   mat (i.e. 02:00 or 13:40). Note that suspend periods are con-
		   figured in multiples of 6 minutes, therefore the stored  con-
		   figuration  may be rounded to a slightly alternate configura-
		   tion.  suspendperiodrepeat indicates the days  in  which  the
		   suspend  period shall be enabled. The option can be specified
		   multiple times to configure multiple times. Command confirmed
		   to work on Intel S2600JF (Appro 512X).

	    set-node-manager-power-draw-range domainid=platform|cpu|memory|high-
	    powerio minpowerdrawrange=watts maxpowerdrawrange=watts
		   This OEM command will set the power draw range  for	a  given
		   domain ID.  After this configuration, any policies within the
		   domain  ID that are outside of this range will be disabled as
		   needed. The current power draw range  can  be  read	via  the
		   get-node-manager-capabilities  above.  Command  confirmed  to
		   work on Intel S2600JF (Appro 512X).

	    get-node-manager-alert-destination
		   This OEM command will get the current alert	destination  in-
		   formation.	Some  of the configuration information output by
		   this command will need to be correlated to BMC device channel
		   and PEF configuration. BMC device channel information can  be
		   viewed  via	.B  bmc-info(8). PEF configuration can be viewed
		   via ipmi-config(8).	 Command  confirmed  to  work  on  Intel
		   S2600JF (Appro 512X).

	    set-node-manager-alert-destination [channelnumber=num] [slavead-
	    dress=address] [destinationselector=num] [alertstringselector=num]
	    [sendalertstring=yes|no] [register=yes|no]
		   This  OEM command will set the current alert receiver. By de-
		   fault, this command will attempt to register an alert  (iden-
		   tical  to  register=yes).  When registering an alert receiver
		   the channelnumber, alertstringselector,  and  sendalertstring
		   options must be specified. The slaveaddress or destinationse-
		   lector  must also be specified, depending on the channel num-
		   ber specified. If register=no, most of these options are  not
		   required.  Appropriate channel number input can be determined
		   via	bmc-info(8).   Destination selector and alert string se-
		   lector information  can  be	determined  via  ipmi-config(8).
		   Command confirmed to work on Intel S2600JF (Appro 512X).

	    get-turbo-synchronization-ratio activecoresconfig=num|all [cpu-
	    socket=num|all]
		   This  OEM  command will get the current Turbo Synchronization
		   Ratio. If cpusocket is not set to a specific cpu socket,  all
		   sockets will return maximum settings.

	    set-turbo-synchronization-ratio turboratiolimit=num|default [cpu-
	    socket=num|all] [activecoresconfig=num|all],
		   This OEM command will set the Turbo Synchronization Ratio. If
		   cpusocket  is not set to a specific cpu socket, it assumed to
		   be applied to all cores. If activecore is not set, it is  as-
		   sumed to be for all cores.

	    get-node-manager-version
		   This  OEM  command will output the current Intel Node Manager
		   version information.  Command  confirmed  to  work  on  Intel
		   S5500WB  (Penguin  Computing  Relion 700), Inventec 5441/5442
		   (Dell Xanadu II/III),  Quanta  S99Q	(Dell  FS12-TY),  Quanta
		   QSSC-S4R (Appro GB812X-CN), Intel S2600JF (Appro 512X).

     Inventec

	    get-nic-mode
		   This OEM command will determine the current NIC mode as dedi-
		   cated  or  shared. Dedicated indicates IPMI is only available
		   on the dedicated management port. Shared  indicates	IPMI  is
		   also  available on one of the primary ethernet ports. Command
		   confirmed to work on Inventec 5441/5442 (Dell Xanadu II/III).

	    set-nic-mode dedicated|shared
		   This OEM command will set the current NIC mode  to  dedicated
		   or  shared.	(See get-nic-mode above for description on dedi-
		   cated vs. shared mode.) This OEM command may internally reset
		   the BMC, making the BMC unusable  for  awhile.  Command  con-
		   firmed to work on Inventec 5441/5442 (Dell Xanadu II/III).

	    get-mac-address
		   This command will retrieve the BMC MAC address. This is actu-
		   ally  not  an OEM command, but rather the normal IPMI MAC ad-
		   dress command (identical to what is	used  in  the  ipmi-con-
		   fig(8) tool). This command is placed here for convenience.

	    set-mac-address dedicated|shared MACADDR
		   This OEM command will set the dedicated or shared BMC MAC ad-
		   dress.   (See get-nic-mode above for description on dedicated
		   vs. shared mode.) The BMC MAC address cannot be  set  through
		   the	normal	IPMI  MAC  address  command (what is used in the
		   ipmi-config(8) tool). The  MACADDR  should  be  specified  in
		   XX:XX:XX:XX:XX:XX form. A shared BMC MAC address may conflict
		   with  normal communication ethernet communication on the pri-
		   mary ethernet port. Users may wish to configuration an alter-
		   nate MAC address instead. After configuration of the MAC  ad-
		   dress, the BMC must be reset. This may be accomplished by ex-
		   ecuting  a  cold-reset with bmc-device(8).  Command confirmed
		   to work on Inventec 5441/5442 (Dell Xanadu II/III).

	    get-bmc-services
		   This OEM command will display the currently enabled BMC  ser-
		   vices.  Command confirmed to work on Inventec 5441/5442 (Dell
		   Xanadu II/III).

	    set-bmc-services enable|disable all|kvm|http|ssh
		   This  OEM  command  will enable or disable other BMC services
		   besides IPMI. all can be specified to enable/disable all ser-
		   vices, kvm specifies KVM and Virtual Storage, http  specifies
		   HTTP  and  HTTPS, and ssh specifies both SSH and Telnet. Com-
		   mand confirmed to work on  Inventec	5441/5442  (Dell  Xanadu
		   II/III).

	    get-authentication-config
		   This  OEM  command will display additional OEM authentication
		   settings.  (See set-authentication-config below for	descrip-
		   tion  on  outputs.)	Command  confirmed  to	work on Inventec
		   5441/5442 (Dell Xanadu II/III).

	    set-authentication-config KEY=VALUE ...
		   This OEM command will set additional OEM authentication  set-
		   tings on the IPMI card. The possible keys and values are max-
		   authenticationfailures=count, lockoutwindow=seconds, lockout-
		   time=seconds,  and  httpsportnumber=num.   maxauthentication-
		   failures specifies the maximum number of allowed  authentica-
		   tion failures. lockoutwindow specifies the window of time the
		   authentication  failure  count can be reached in to disable a
		   user. lockouttime specifies the time period a  user	is  dis-
		   abled if the authentication failure count is reached. Setting
		   0  to  any  of the settings will disable the lockout feature.
		   Each time any of these settings is modified, the  authentica-
		   tion failure count of each enabled user is reset to 0. Multi-
		   ple	key=value  pairs may be specified. If no key=value pairs
		   are specified, available pairs are output. Command  confirmed
		   to work on Inventec 5441/5442 (Dell Xanadu II/III).

	    get-account-status
		   This  OEM  command  will output the current account status of
		   users on the BMC. This command is particularly usefor for de-
		   termining which users in the system may have been locked  out
		   via	authentication	failures  configured via set-authentica-
		   tion-config. Command confirmed to work on Inventec  5441/5442
		   (Dell Xanadu II/III).

	    get-dns-config
		   This  OEM  command  will display additional OEM DNS settings.
		   (See set-dns-config below for description on  outputs.)  Com-
		   mand  confirmed  to	work  on Inventec 5441/5442 (Dell Xanadu
		   II/III).

	    set-dns-config KEY=VALUE ...
		   This OEM command will set additional OEM DNS settings on  the
		   IPMI  card.	The  possible  keys  and  values are dnsdhcp=en-
		   able|disable,   dnsserver1=ipaddress,   dnsserver2=ipaddress,
		   dnsregisterbmc=enable|disable,  dnsbmchostname=string, dnsdo-
		   mainnamedhcp=enable|disable, and dnsdomainname=string.  dnsd-
		   hcp	specifies  if  the DNS server IP addresses should be as-
		   signed from the DHCP server.  dnsserver1 and dnsserver2 spec-
		   ify the IP address for server 1  and  2  respectively.  These
		   fields are read only if dnsdhcp and DHCP are enabled. dnsreg-
		   isterbmc specifies if the BMC host name is registered via the
		   DNS	server. dnsbmchostname specifies the BMC host name. This
		   field is read only if dnsregisterbmc is  enabled.  dnsdomain-
		   namedhcp  specifies	if the DNS domainname should be assigned
		   from the DHCP server. dnsdomainname specifies the DNS  domain
		   name  string. This field is read only if dnsdomainnamedhcp is
		   enabled. Multiple key=value pairs may  be  specified.  If  no
		   key=value  pairs  are  specified, available pairs are output.
		   Command confirmed to work on Inventec 5441/5442 (Dell  Xanadu
		   II/III).

	    get-web-server-config
		   This  OEM  command will get the current web server configura-
		   tion on the IPMI card. Command confirmed to work on	Inventec
		   5441/5442 (Dell Xanadu II/III).

	    set-web-server-config KEY=VALUE ...
		   This  OEM  command will set the current web server configura-
		   tion on the IPMI card. The possible keys and values are  web-
		   server=enable|disable, webservertimeout=seconds, httpportnum-
		   ber=num,  and  httpsportnumber=num.	Multiple key=value pairs
		   may be specified. If no key=value pairs are specified, avail-
		   able pairs are output. Command confirmed to work on	Inventec
		   5441/5442 (Dell Xanadu II/III).

	    get-power-management-config
		   This  OEM  command will get the current power management con-
		   figuration on the IPMI card. Command confirmed to work on In-
		   ventec 5441/5442 (Dell Xanadu II/III).

	    set-power-management-config KEY=VALUE ...
		   This OEM command will set the current power	management  con-
		   figuration on the IPMI card. The possible keys and values are
		   dpnmpowermanagement=enable|disable,	 powerstaggeringacrecov-
		   ery=immediate|auto|user,   powerondelay=seconds,   and   max-
		   powerondelay=seconds.   dpnmpowermanagement	enables  or dis-
		   ables DPNM, Dynamic Power  Node  Management.  For  powerstag-
		   geringacrecovery,  immediate  specifies no delay, auto gener-
		   ates a delay time between the minimum and maximum configured,
		   and user uses the user defined time defined by  powerondelay.
		   powerondelay  must be within the minimum and maximum power on
		   delay times. Multiple key=value pairs may be specified. If no
		   key=value pairs are specified, available  pairs  are  output.
		   Command  confirmed to work on Inventec 5441/5442 (Dell Xanadu
		   II/III).

	    get-sol-idle-timeout
		   This OEM command will get the SOL idle timeout. Command  con-
		   firmed to work on Inventec 5441/5442 (Dell Xanadu II/III).

	    set-sol-idle-timeout idle-timeout
		   This   OEM  command	will  set  the	SOL  idle  timeout.  The
		   idle-timeout is one-based, max of 65535, in 1  minute  incre-
		   ments  (e.g.  1  =  1  minute), 0 or "none" will configure no
		   timeout. Command confirmed  to  work  on  Inventec  5441/5442
		   (Dell Xanadu II/III).

	    get-telnet-ssh-redirect-status
		   This  OEM  command  will  get the telnet/SSH redirect status.
		   Command confirmed to work on Inventec 5442 (Dell Xanadu III).

	    set-telnet-ssh-redirect-status enable|disable
		   This OEM command will enable or disable  telnet/SSH	redirect
		   status.   Command  confirmed  to  work on Inventec 5442 (Dell
		   Xanadu III).

	    get-board-id
		   This OEM command can get the board ID. Command  confirmed  to
		   work on Inventec 5441/5442 (Dell Xanadu II/III).

	    set-board-id ID
		   This  OEM  command can set the board ID. Command confirmed to
		   work on Inventec 5441/5442 (Dell Xanadu II/III).

	    get-fcb-version
		   This OEM command can get the fan control board (FCB)  version
		   number.   Command  confirmed  to  work  on Inventec 5441/5442
		   (Dell Xanadu II/III).

	    set-fcb-version majorversion minorversion
		   This OEM command can set the fan control board (FCB)  version
		   number.   The majorversion and minorversion must be specified
		   in hex. Command confirmed to work on Inventec 5441/5442 (Dell
		   Xanadu II/III).

	    get-sol-inactivity-timeout
		   This OEM command will retrieve the  SOL  inactivity	timeout.
		   Command  confirmed to work on Inventec 5441/5442 (Dell Xanadu
		   II/III).

	    set-sol-inactivity-timeout inactivity-timeout
		   This OEM command will set the SOL inactivity timeout. The in-
		   activity-timeout is one-based, max of 65535, in 1 minute  in-
		   crements  (e.g.  1 = 1 minute), 0 or "none" will configure no
		   timeout.  Command confirmed to  work  on  Inventec  5441/5442
		   (Dell Xanadu II/III).

	    restore-to-defaults all|user|lan|sol|serial|pef
		   This  OEM command will restore certain BMC configuration sec-
		   tions back to default values. The command will spin until the
		   reset is confirmed to be complete. Command confirmed to  work
		   on  Inventec  5442 (Dell Xanadu III). After running this com-
		   mand, the BMC must be reset to return it to functioning  sta-
		   tus.  This may be accomplished by executing a cold-reset with
		   bmc-device(8).

	    read-eeprom at24c256n
		   This OEM command will read the specified eeprom. Command con-
		   firmed  to  work  on  Inventec  5441  (Dell	Xanadu	II)  for
		   at24c256.

	    clear-eeprom at24c256n
		   This OEM command will clear the specified eeprom, overwriting
		   all	bytes  with 0xFF. If the verbose option is set, progress
		   percent will be output as the clearing is being done. Command
		   confirmed to work on  Inventec  5441  (Dell	Xanadu	II)  for
		   at24c256.

     Quanta

	    get-nic-mode
		   This OEM command will determine the current NIC mode as dedi-
		   cated  or  shared. Dedicated indicates IPMI is only available
		   on the dedicated management port. Shared  indicates	IPMI  is
		   also  available on one of the primary ethernet ports. Command
		   confirmed to work on Quanta S99Q (Dell FS12-TY).

	    set-nic-mode dedicated|shared
		   This OEM command will set the current NIC mode  to  dedicated
		   or  shared.	(See get-nic-mode above for description on dedi-
		   cated vs. shared mode.) This OEM command may internally reset
		   the BMC, making the BMC unusable  for  awhile.  Command  con-
		   firmed to work on Quanta S99Q (Dell FS12-TY).

	    get-bmc-services
		   This  OEM command will display the currently enabled BMC ser-
		   vices.  Command  confirmed  to  work  on  Quanta  S99Q  (Dell
		   FS12-TY).

	    set-bmc-services enable|disable all|kvm|http|ssh
		   This  OEM  command  will enable or disable other BMC services
		   besides IPMI. all can be specified to enable/disable all ser-
		   vices, kvm specifies KVM and Virtual Storage, http  specifies
		   HTTP  and  HTTPS, and ssh specifies both SSH and Telnet. Com-
		   mand confirmed to work on Quanta S99Q (Dell FS12-TY).

	    get-account-status
		   This OEM command will output the current  account  status  of
		   users on the BMC. This command is particularly usefor for de-
		   termining  which users in the system may have been locked out
		   via authentication failures. Command  confirmed  to	work  on
		   Quanta S99Q (Dell FS12-TY).

	    get-dns-config
		   This  OEM  command  will display additional OEM DNS settings.
		   (See set-dns-config below for description on  outputs.)  Com-
		   mand confirmed to work on Quanta S99Q (Dell FS12-TY).

	    set-dns-config KEY=VALUE ...
		   This  OEM command will set additional OEM DNS settings on the
		   IPMI card. The  possible  keys  and	values	are  dnsdhcp=en-
		   able|disable,   dnsserver1=ipaddress,   dnsserver2=ipaddress,
		   dnsregisterbmc=enable|disable, dnsbmchostname=string,  dnsdo-
		   mainnamedhcp=enable|disable,  and dnsdomainname=string. dnsd-
		   hcp specifies if the DNS server IP addresses  should  be  as-
		   signed from the DHCP server.  dnsserver1 and dnsserver2 spec-
		   ify	the  IP  address  for server 1 and 2 respectively. These
		   fields are read only if dnsdhcp and DHCP are enabled. dnsreg-
		   isterbmc specifies if the BMC host name is registered via the
		   DNS server. dnsbmchostname specifies the BMC host name.  This
		   field  is  read only if dnsregisterbmc is enabled. dnsdomain-
		   namedhcp specifies if the DNS domainname should  be	assigned
		   from  the DHCP server. dnsdomainname specifies the DNS domain
		   name string. This field is read only if dnsdomainnamedhcp  is
		   enabled.  Multiple  key=value  pairs  may be specified. If no
		   key=value pairs are specified, available  pairs  are  output.
		   Command confirmed to work on Quanta S99Q (Dell FS12-TY).

	    get-web-server-config
		   This  OEM  command will get the current web server configura-
		   tion on the IPMI card. Command confirmed to	work  on  Quanta
		   S99Q (Dell FS12-TY).

	    set-web-server-config KEY=VALUE...
		   This  OEM  command will set the current web server configura-
		   tion on the IPMI card. The possible keys and values are  web-
		   server=enable|disable, webservertimeout=seconds, httpportnum-
		   ber=num,  and  httpsportnumber=num.	Multiple key=value pairs
		   may be specified. If no key=value pairs are specified, avail-
		   able pairs are output. Command confirmed to	work  on  Quanta
		   S99Q (Dell FS12-TY).

	    get-power-management-config
		   This  OEM  command will get the current power management con-
		   figuration on the IPMI card. Command  confirmed  to	work  on
		   Quanta S99Q (Dell FS12-TY).

	    set-power-management-config KEY=VALUE ...
		   This  OEM  command will set the current power management con-
		   figuration on the IPMI card. The possible keys and values are
		   dpnmpowermanagement=enable|disable,	 powerstaggeringacrecov-
		   ery=immediate|auto|user,   powerondelay=seconds,   and   max-
		   powerondelay=seconds.  dpnmpowermanagement  enables	or  dis-
		   ables  DPNM,  Dynamic  Power  Node Management. For powerstag-
		   geringacrecovery, immediate specifies no delay,  auto  gener-
		   ates a delay time between the minimum and maximum configured,
		   and	user uses the user defined time defined by powerondelay.
		   powerondelay must be within the minimum and maximum power  on
		   delay times. Multiple key=value pairs may be specified. If no
		   key=value  pairs  are  specified, available pairs are output.
		   Command confirmed to work on Quanta S99Q (Dell FS12-TY).

	    get-sol-idle-timeout
		   This OEM command will get the SOL idle timeout. Command  con-
		   firmed to work on Quanta S99Q (Dell FS12-TY).

	    set-sol-idle-timeout idle-timeout
		   This   OEM  command	will  set  the	SOL  idle  timeout.  The
		   idle-timeout is one-based, max of 65535, in 1  minute  incre-
		   ments  (e.g.  1  =  1  minute), 0 or "none" will configure no
		   timeout. Command confirmed  to  work  on  Quanta  S99Q  (Dell
		   FS12-TY).

	    get-telnet-ssh-redirect-status
		   This  OEM  command  will  get the telnet/SSH redirect status.
		   Command confirmed to work on Quanta S99Q (Dell FS12-TY).

	    set-telnet-ssh-redirect-status enable|disable
		   This OEM command will enable or disable  telnet/SSH	redirect
		   status.   Command  confirmed  to  work  on  Quanta S99Q (Dell
		   FS12-TY).

	    reset-to-defaults all|user|lan|sol|serial|pef
		   This OEM command will reset certain	BMC  configuration  sec-
		   tions back to default values. The command will spin until the
		   reset  is confirmed to be complete. Command confirmed to work
		   on Quanta S99Q (Dell FS12-TY).  After running  this	command,
		   the	BMC  must  be  reset to return it to functioning status.
		   This may be accomplished by executing a cold-reset with  bmc-
		   device(8).

	    get-processor-information [processor-index]
		   This OEM command will determine system processor information.
		   By  default, information about each processor will be output.
		   If a processor-index is specified, only that specific proces-
		   sor will be output. Command confirmed to work on Quanta  S99Q
		   (Dell FS12-TY).

	    read-mac-address s99q dedicated|shared
		   This  command will read the currently configured dedicated or
		   shared MAC address for a specified motherboard. It will  read
		   the	MAC  address  directly from the BMC eeprom. Command con-
		   firmed to work on Quanta S99Q (Dell FS12-TY) for s99q.

	    write-mac-address s99q dedicated|shared MACADDR
		   This OEM command will set the dedicated or shared BMC MAC ad-
		   dress for a specified motherboard. It  will	be  written  di-
		   rectly  to  the  BMC  eeprom. (See get-nic-mode above for de-
		   scription on dedicated vs. shared mode.) The BMC MAC  address
		   cannot  be  set  through  the normal IPMI MAC address command
		   (what is used in the ipmi-config(8) tool). The MACADDR should
		   be specified in XX:XX:XX:XX:XX:XX form. A shared BMC MAC  ad-
		   dress  may conflict with normal communication ethernet commu-
		   nication on the primary ethernet port. Users may wish to con-
		   figuration an alternate MAC address instead. After configura-
		   tion of the MAC address, the BMC must be reset. This  may  be
		   accomplished  by  executing	a cold-reset with bmc-device(8).
		   Command confirmed to work on Quanta S99Q (Dell  FS12-TY)  for
		   s99q.

     Sun

	    get-led

		   This  OEM command will output current LED mode. off indicates
		   the LED is steady off, on indicates the  LED  is  steady  on,
		   standby  indicates  the  LED blinks at a 100ms on, 2900ms off
		   rate, slow indicates the LED is blinking at 1Hz, and fast in-
		   dicates the LED is blinking at 4Hz. If the verbose option  is
		   set, sensor names will be output with their entity ID and in-
		   stance   when  appropriate.	(Similar  to  the  --entity-sen-
		   sor-names option in ipmi-sensors.)  This OEM command requires
		   access to the SDR. Command confirmed to work on Sun Fire 4140
		   with ILOM.

	    set-led record_id off|on|standby|slow|fast
		   This OEM command will configure LED modes. (See get-led above
		   for description on LED modes.) This OEM command requires  ac-
		   cess  to  the SDR. Command confirmed to work on Sun Fire 4140
		   with ILOM.

     Supermicro

	    extra-firmware-info
		   This OEM command will output additional firmware version  in-
		   formation.  Command confirmed to work on Supermicro H8QME.

	    reset-intrusion
		   This  OEM  command  will reset the motherboard intrusion flag
		   after it has been triggered. For example, in ipmi-sensors  or
		   ipmi-sel, you may notice a 'General Chassis Intrusion' if the
		   motherboard	chassis is not open, but was opened in the past.
		   Command confirmed to work on Supermicro H8QME.

	    get-bmc-services-status
		   This OEM command will determine if  non-IPMI  services  (e.g.
		   ssh,  http,	https,	vnc, etc.) are currently enabled or dis-
		   abled on the BMC.  Command confirmed to  work  on  Supermicro
		   X8DTG.

	    set-bmc-services-status enable|disable
		   This OEM command will enable or disable all non-IPMI services
		   on  the  BMC.  This	command can be used to enable or disable
		   non-IPMI services such as ssh, http, https, and vnc.  Command
		   confirmed to work on Supermicro X8DTG.

	    get-power-supply-status ps_num
		   This  OEM command will get the status of a regular power sup-
		   ply.  Presently, it can get the status of  power  supplies  1
		   through  3.	 Command  confirmed to work on Supermicro X8DTU,
		   Supermicro X8STi, and Supermicro X9DRW.

	    get-power-supply-status2 ps_num
		   This OEM command will get the status of a regular power  sup-
		   ply.   Presently,  it  can get the status of power supplies 1
		   and 2. Command confirmed to work on Supermicro X10DRU-i+.

	    get-pmbus-power-supply-status ps_num
		   This OEM command will get the status of a PMBus  based  power
		   supply.  Presently, it can get the status of power supplies 1
		   through  3.	 Command  confirmed to work on Supermicro X8DTU,
		   Supermicro X8STi, Supermicro X9DRW, and Supermicro X9DRD.

     Wistron

	    get-system-info KEY
		   This OEM command can retrieve the motherboard system informa-
		   tion.  Valid keys are asset-tag,  service-tag,  product-name.
		   Command confirmed to work on Wistron / Dell Poweredge C6220.

	    get-nic-mode
		   This OEM command will determine the current NIC mode as dedi-
		   cated  or  shared. Dedicated indicates IPMI is only available
		   on the dedicated management port. Shared  indicates	IPMI  is
		   also  available on one of the primary ethernet ports. Command
		   confirmed to work on Wistron / Dell Poweredge C6220.

	    set-nic-mode dedicated|shared
		   This OEM command will set the current NIC mode  to  dedicated
		   or  shared.	(See get-nic-mode above for description on dedi-
		   cated vs. shared mode.) After running this command,	the  BMC
		   may	need to be reset to finalize the configuration. This may
		   be accomplished by executing a cold-reset with bmc-device(8).
		   Command confirmed to work on Wistron / Dell Poweredge C6220.

	    get-shared-nic-selection
		   This OEM command will  determine  the  current  NIC	IPMI  is
		   shared  with  if  the mode is shared. (See get-nic-mode above
		   for description on dedicated vs. shared mode.)  Command  con-
		   firmed to work on Wistron / Dell Poweredge C6220.

	    set-shared-nic-selection nic1|nic2|nic3|nic4|clear
		   This  OEM command will set the current NIC sharing selection.
		   If the current NIC mode is dedicated it is advisable to clear
		   this setting with the clear option. Command confirmed to work
		   on Wistron / Dell Poweredge C6220.

	    get-bmc-services
		   This OEM command will display the currently enabled BMC  ser-
		   vices.  Command confirmed to work on Wistron / Dell Poweredge
		   C6220.

	    set-bmc-services enable|disable all|kvm|http|ssh|snmp|telnet
		   This  OEM  command  will enable or disable other BMC services
		   besides IPMI. all can be specified to enable/disable all ser-
		   vices, kvm specifies KVM and Virtual Storage, http  specifies
		   HTTP  and  HTTPS. Command confirmed to work on Wistron / Dell
		   Poweredge C6220.

	    get-account-status
		   This OEM command will output the current  account  status  of
		   users on the BMC. This command is particularly usefor for de-
		   termining  which users in the system may have been locked out
		   via authentication failures. Command  confirmed  to	work  on
		   Wistron / Dell Poweredge C6220.

	    get-dns-config
		   This  OEM  command  will display additional OEM DNS settings.
		   (See set-dns-config below for description on  outputs.)  Com-
		   mand confirmed to work on Wistron / Dell Poweredge C6220.

	    set-dns-config KEY=VALUE ...
		   This  OEM command will set additional OEM DNS settings on the
		   IPMI card. The  possible  keys  and	values	are  dnsdhcp=en-
		   able|disable,   dnsserver1=ipaddress,   dnsserver2=ipaddress,
		   dnsregisterbmc=enable|disable, dnsbmchostname=string,  dnsdo-
		   mainnamedhcp=enable|disable,     dnsdomainname=string,    and
		   dnsregistrationdelay=seconds. dnsdhcp specifies  if	the  DNS
		   server  IP addresses should be assigned from the DHCP server.
		   dnsserver1 and dnsserver2 specify the IP address for server 1
		   and 2 respectively. These fields are read only if dnsdhcp and
		   DHCP are enabled. dnsregisterbmc specifies if  the  BMC  host
		   name  is registered via the DNS server. dnsbmchostname speci-
		   fies the BMC host name. This field is read only if  dnsregis-
		   terbmc is enabled. dnsdomainnamedhcp specifies if the DNS do-
		   mainname  should be assigned from the DHCP server. dnsdomain-
		   name specifies the DNS domain name string. This field is read
		   only if dnsdomainnamedhcp  is  enabled.  dnsregistrationdelay
		   specifies  the  delay  the  BMC  should  take  after the IPMI
		   process is up and running. Multiple key=value  pairs  may  be
		   specified.  If  no  key=value  pairs are specified, available
		   pairs are output. Command confirmed to work on Wistron / Dell
		   Poweredge C6220.

	    get-web-server-config
		   This OEM command will get the current web  server  configura-
		   tion on the IPMI card. Command confirmed to work on Wistron /
		   Dell Poweredge C6220.

	    set-web-server-config KEY=VALUE...
		   This  OEM  command will set the current web server configura-
		   tion on the IPMI card. The possible keys and values are  web-
		   server=enable|disable, webservertimeout=seconds, httpportnum-
		   ber=num,  and  httpsportnumber=num.	Multiple key=value pairs
		   may be specified. If no key=value pairs are specified, avail-
		   able pairs are output. Command confirmed to work on Wistron /
		   Dell Poweredge C6220.

	    get-power-management-config
		   This OEM command will get the current power	management  con-
		   figuration  on  the	IPMI  card. Command confirmed to work on
		   Wistron / Dell Poweredge C6220.

	    set-power-management-config KEY=VALUE ...
		   This OEM command will set the current power	management  con-
		   figuration on the IPMI card. The possible keys and values are
		   powerstaggeringacrecovery=immediate|auto|user,     poweronde-
		   lay=seconds,  and  maxpowerondelay=seconds.	For   powerstag-
		   geringacrecovery,  immediate  specifies no delay, auto gener-
		   ates a delay time between the minimum and maximum configured,
		   and user uses the user defined time defined by  powerondelay.
		   powerondelay  must be within the minimum and maximum power on
		   delay times. Multiple key=value pairs may be specified. If no
		   key=value pairs are specified, available  pairs  are  output.
		   Command confirmed to work on Wistron / Dell Poweredge C6220.

	    get-ipv6-settings
		   This  OEM  command  will get the current IPv6 settings on the
		   IPMI card.  Command confirmed to work on Wistron / Dell  Pow-
		   eredge C6220.

	    set-ipv6-settings KEY=VALUE ...
		   This  OEM  command  will set the current IPv6 settings on the
		   IPMI card.  The possible keys and values are ipv6=enable|dis-
		   able,  ipv6address=ipaddress,   ipv6gatewayaddress=ipaddress,
		   ipv6prefixlength=length,	  ipv6autoconfig=enable|disable,
		   ipv6autodns=enable|disable,	 ipv6dnsserver1=ipaddress,   and
		   ipv6dnsserver2=ipaddress.  If  no  key=value pairs are speci-
		   fied, available pairs are output. Some fields  may  be  read-
		   only on specific Poweredge systems. Command confirmed to work
		   on Wistron / Dell Poweredge C6220.

	    get-ipv6-trap-settings
		   This OEM command will get the current IPv6 SNMP trap settings
		   on the IPMI card. Command confirmed to work on Wistron / Dell
		   Poweredge C6220.

	    set-ipv6-trap-settings index KEY=VALUE ...
		   This OEM command will set the current IPv6 SNMP trap settings
		   on  the IPMI card. The index indicates the index position for
		   the configuration. It is followed by a set  of  configuration
		   keys  and  values.  The possible keys and values are destina-
		   tiontype=pet|oem1|oem2,     alertacktimeout=seconds,      re-
		   tries=count,   and	ipv6snmptrapaddress=ipaddress.	 If   no
		   key=value pairs are specified, available  pairs  are  output.
		   Some  fields  may be read-only on specific Poweredge systems.
		   Command confirmed to work on Wistron / Dell Poweredge C6220.

	    get-sol-idle-timeout
		   This OEM command will get the SOL idle timeout. Command  con-
		   firmed to work on Wistron / Dell Poweredge C6220.

	    set-sol-idle-timeout idle-timeout
		   This   OEM  command	will  set  the	SOL  idle  timeout.  The
		   idle-timeout is one-based, max of 65535, in 1  minute  incre-
		   ments  (e.g.  1  =  1  minute), 0 or "none" will configure no
		   timeout. Command confirmed to work on  Wistron  /  Dell  Pow-
		   eredge C6220.

	    get-telnet-redirect-function
		   This  OEM command will get the telnet redirect function. Com-
		   mand confirmed to work on Wistron / Dell Poweredge C6220.

	    set-telnet-redirect-function disable|solenable|smashenable
		   This OEM command will enable or disable telnet redirect func-
		   tion.  Command confirmed to work on Wistron / Dell  Poweredge
		   C6220.

	    get-dhcp-retry
		   This  OEM  command  will  retrieve  DHCP  retry  information.
		   Wistron / Dell Poweredge C6220.

	    set-dhcp-retry retry-count retry-interval retry-timeout
		   This  OEM  command  will  set  DHCP	retry  information.  The
		   retry-count	is  one-based, max of 254, 0 or "none" will con-
		   figure no retries, 255 or "indefinite"  will  configure  con-
		   stant  retries. The retry-interval is one-based, in 10 second
		   increments (e.g. 1 = 10 seconds). The retry-timeout	is  one-
		   based, in 1 minute increments (e.g. 1 = 1 minute). After run-
		   ning  this  command, the BMC may need to be reset to finalize
		   the configuration. This may be accomplished	by  executing  a
		   cold-reset  with bmc-device(8).  Command confirmed to work on
		   Wistron / Dell Poweredge C6220.

	    get-link-status-change-control
		   This OEM command will get the current link status change con-
		   trol. If it	reports  "Link	Down  Resilience  Enabled",  BMC
		   firmware  will  do  nothing upon detecting Link Status Change
		   until the DHCP lease is expired. If it reports "DHCP  Re-Dis-
		   covery  Enabled",  BMC  firmware  will perform DHCP Discovery
		   upon detecting link status going down than back  up.  Command
		   confirmed to work on Wistron / Dell Poweredge C6220..

	    set-link-status-change-control link_resilience|dhcp_rediscovery
		   This  OEM command will set the current NIC link status change
		   control setting.  (See  set-link-status-change-control  above
		   for	description  of  arguments). After running this command,
		   the BMC may need to be reset to finalize  the  configuration.
		   This  may be accomplished by executing a cold-reset with bmc-
		   device(8).  Command confirmed to work on Wistron / Dell  Pow-
		   eredge C6220.

	    set-password-policy <enable|disable>
		   This  OEM  command  will  set the current password policy en-
		   forcement. If password policy is enabled, BMC passwords  must
		   meet the following requirements: Not contain the user's name,
		   be  8-14  characters long, and contain three of the following
		   four, an English uppercase character (A-Z), an English lower-
		   case character (a-z), a digit (0-9), a special character  (!,
		   $,  #,  %, etc.). Command confirmed to work on Wistron / Dell
		   Poweredge C6220.

	    read-proprietary-string
		   This OEM command will read the proprietary string  stored  in
		   the FRU.  The proprietary string is a string the user may set
		   for any management purpose. It can also be read via ipmi-fru.
		   Command confirmed to work on Wistron / Dell Poweredge C6220.

	    set-proprietary-string <string>
		   This  OEM command will write the proprietary string stored in
		   the FRU.  The maximum length string is 80 characters. Command
		   confirmed to work on Wistron / Dell Poweredge C6220.

	    clear-proprietary-string
		   This OEM command will clear the proprietary string stored  in
		   the	FRU.   Command	confirmed to work on Wistron / Dell Pow-
		   eredge C6220.

HOSTRANGED SUPPORT
     Multiple hosts can be input either as an explicit comma separated lists  of
     hosts  or	a  range  of hostnames in the general form: prefix[n-m,l-k,...],
     where n < m and l < k, etc. The later form should not be confused with reg-
     ular expression character	classes  (also	denoted  by  []).  For	example,
     foo[19] does not represent foo1 or foo9, but rather represents a degenerate
     range: foo19.

     This  range  syntax  is meant only as a convenience on clusters with a pre-
     fixNN naming convention and specification of ranges should not  be  consid-
     ered  necessary -- the list foo1,foo9 could be specified as such, or by the
     range foo[1,9].

     Some examples of range usage follow:
	 foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
	 foo[7,9-10] instead of foo7,foo9,foo10
	 foo[0-3] instead of foo0,foo1,foo2,foo3

     As a reminder to the reader, some shells will interpret brackets ([ and  ])
     for  pattern  matching. Depending on your shell, it may be necessary to en-
     close ranged lists within quotes.

     When multiple hosts are specified by the user, a thread  will  be	executed
     for  each	host  in  parallel up to the configured fanout (which can be ad-
     justed via the -F option). This will allow communication to  large  numbers
     of nodes far more quickly than if done in serial.

     By  default,  standard  output from each node specified will be output with
     the hostname prepended to each line. Although this output	is  readable  in
     many situations, it may be difficult to read in other situations. For exam-
     ple,  output  from  multiple nodes may be mixed together. The -B and -C op-
     tions can be used to change this default.

     In-band IPMI Communication will be used when the host "localhost" is speci-
     fied. This allows the user to add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING
     Most often, IPMI problems are due to configuration problems.

     IPMI over LAN problems involve a misconfiguration of the  remote  machine's
     BMC.   Double  check  to make sure the following are configured properly in
     the remote machine's BMC: IP address, MAC address, subnet	mask,  username,
     user  enablement,	user privilege, password, LAN privilege, LAN enablement,
     and allowed authentication type(s). For IPMI 2.0 connections, double  check
     to make sure the cipher suite privilege(s) and K_g key are configured prop-
     erly. The ipmi-config(8) tool can be used to check and/or change these con-
     figuration settings.

     Inband  IPMI problems are typically caused by improperly configured drivers
     or non-standard BMCs.

     In addition to the troubleshooting tips below, please see WORKAROUNDS below
     to also if there are any vendor specific bugs that have been discovered and
     worked around.

     Listed below are many of the common issues for error messages.   For  addi-
     tional support, please e-mail the <freeipmi-users@gnu.org> mailing list.

     "username	invalid"  - The username entered (or a NULL username if none was
     entered) is not available on the remote machine. It may  also  be	possible
     the remote BMC's username configuration is incorrect.

     "password	invalid"  - The password entered (or a NULL password if none was
     entered) is not correct. It may also be possible the password for the  user
     is not correctly configured on the remote BMC.

     "password	verification  timeout" - Password verification has timed out.  A
     "password invalid" error (described above) or a generic  "session	timeout"
     (described below) occurred.  During this point in the protocol it cannot be
     differentiated which occurred.

     "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered)
     is  not  correct. It may also be possible the K_g key is not correctly con-
     figured on the remote BMC.

     "privilege level insufficient" - An IPMI command  requires  a  higher  user
     privilege	than the one authenticated with. Please try to authenticate with
     a higher privilege. This may require authenticating  to  a  different  user
     which has a higher maximum privilege.

     "privilege  level	cannot	be obtained for this user" - The privilege level
     you are attempting to authenticate with is higher than the maximum  allowed
     for this user. Please try again with a lower privilege. It may also be pos-
     sible  the  maximum  privilege  level  allowed for a user is not configured
     properly on the remote BMC.

     "authentication type unavailable for attempted privilege level" -	The  au-
     thentication  type  you wish to authenticate with is not available for this
     privilege level. Please try again with an alternate authentication type  or
     alternate	privilege level. It may also be possible the available authenti-
     cation types you can authenticate with are not correctly configured on  the
     remote BMC.

     "cipher  suite  id unavailable" - The cipher suite id you wish to authenti-
     cate with is not available on the remote BMC. Please try again with an  al-
     ternate cipher suite id. It may also be possible the available cipher suite
     ids are not correctly configured on the remote BMC.

     "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine.
     Please try to use IPMI 1.5 instead.

     "connection  timeout"  - Initial IPMI communication failed. A number of po-
     tential errors are possible, including an invalid	hostname  specified,  an
     IPMI  IP  address	cannot	be  resolved,  IPMI is not enabled on the remote
     server, the network connection is bad, etc. Please verify configuration and
     connectivity.

     "session timeout" - The IPMI session has timed out. Please  reconnect.   If
     this  error occurs often, you may wish to increase the retransmission time-
     out. Some remote BMCs are considerably slower than others.

     "device not found" - The specified device could not be found. Please  check
     configuration or inputs and try again.

     "driver  timeout"	- Communication with the driver or device has timed out.
     Please try again.

     "message timeout" - Communication with the driver or device has timed  out.
     Please try again.

     "BMC busy" - The BMC is currently busy. It may be processing information or
     have too many simultaneous sessions to manage. Please wait and try again.

     "could  not  find	inband	device"  -  An inband device could not be found.
     Please check configuration or specify specific device or driver on the com-
     mand line.

     "driver timeout" - The inband driver has timed out communicating to the lo-
     cal BMC or service processor. The BMC or service processor may be	busy  or
     (worst case) possibly non-functioning.

WORKAROUNDS
     With  so many different vendors implementing their own IPMI solutions, dif-
     ferent vendors may implement their IPMI protocols incorrectly. The  follow-
     ing describes a number of workarounds currently available to handle discov-
     ered compliance issues. When possible, workarounds have been implemented so
     they  will  be transparent to the user. However, some will require the user
     to specify a workaround be used via the -W option.

     The hardware listed below may only indicate the hardware that a problem was
     discovered on. Newer versions of hardware may fix	the  problems  indicated
     below.  Similar machines from vendors may or may not exhibit the same prob-
     lems. Different vendors may license  their  firmware  from  the  same  IPMI
     firmware developer, so it may be worthwhile to try workarounds listed below
     even if your motherboard is not listed.

     If  you believe your hardware has an additional compliance issue that needs
     a workaround to be implemented, please contact the FreeIPMI maintainers  on
     <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

     assumeio  -  This workaround flag will assume inband interfaces communicate
     with system I/O rather than being memory-mapped. This will work around sys-
     tems that report invalid base addresses. Those hitting this issue	may  see
     "device not supported" or "could not find inband device" errors.  Issue ob-
     served on HP ProLiant DL145 G1.

     spinpoll  -  This workaround flag will inform some inband drivers (most no-
     tably the KCS driver) to spin while polling rather than putting the process
     to sleep. This may significantly improve the wall	clock  running	time  of
     tools  because  an  operating  system  scheduler's  granularity may be much
     larger than the time it takes to perform a single IPMI message transaction.
     However, by spinning, your system may be performing less useful work by not
     contexting out the tool for a more useful task.

     authcap - This workaround flag will skip early checks for username capabil-
     ities, authentication capabilities, and K_g support and allow IPMI  authen-
     tication  to  succeed.  It works around multiple issues in which the remote
     system does not properly report username capabilities, authentication capa-
     bilities, or K_g status. Those hitting this issue	may  see  "username  in-
     valid", "authentication type unavailable for attempted privilege level", or
     "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4, In-
     tel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

     nochecksumcheck  - This workaround flag will tell FreeIPMI to not check the
     checksums returned from IPMI command responses.  It  works  around  systems
     that  return invalid checksums due to implementation errors, but the packet
     is otherwise valid. Users are cautioned on the use of this  option,  as  it
     removes  validation  of packet integrity in a number of circumstances. How-
     ever, it is unlikely to be an issue in most situations. Those hitting  this
     issue may see "connection timeout", "session timeout", or "password verifi-
     cation  timeout"  errors.	On  IPMI  1.5 connections, the "noauthcodecheck"
     workaround may also needed too. Issue observed on Supermicro X9SCM-iiF, Su-
     permicro X9DRi-F, and Supermicro X9DRFR.

     idzero - This workaround flag will allow empty session IDs to  be	accepted
     by  the client. It works around IPMI sessions that report empty session IDs
     to the client. Those hitting this issue may see "session  timeout"  errors.
     Issue observed on Tyan S2882 with M3289 BMC.

     unexpectedauth  - This workaround flag will allow unexpected non-null auth-
     codes to be checked as though they were expected. It works around an  issue
     when  packets contain non-null authentication data when they should be null
     due to disabled per-message authentication. Those hitting	this  issue  may
     see "session timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425.
     Confirmed fixed on newer firmware.

     forcepermsg - This workaround flag will force per-message authentication to
     be  used no matter what is advertised by the remote system. It works around
     an issue when per-message authentication is advertised as disabled  on  the
     remote  system, but it is actually required for the protocol. Those hitting
     this issue may see "session timeout" errors.  Issue observed on IBM eServer
     325.

     endianseq - This workaround flag will flip the endian of  the  session  se-
     quence  numbers  to allow the session to continue properly. It works around
     IPMI 1.5 session sequence numbers that are the wrong endian.  Those hitting
     this issue may see "session timeout" errors. Issue  observed  on  some  Sun
     ILOM 1.0/2.0 (depends on service processor endian).

     noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the
     authentication codes returned from IPMI 1.5  command  responses.  It  works
     around  systems  that return invalid authentication codes due to hashing or
     implementation errors. Users are cautioned on the use of this option, as it
     removes an authentication check verifying the validity of	a  packet.  How-
     ever, in most organizations, this is unlikely to be a security issue. Those
     hitting  this  issue  may	see  "connection timeout", "session timeout", or
     "password verification timeout" errors.   Issue  observed	on  Xyratex  FB-
     H8-SRAY, Intel Windmill, Quanta Winterfell, and Wiwynn Windmill.

     intel20  - This workaround flag will work around several Intel IPMI 2.0 au-
     thentication issues. The issues covered include padding of  usernames,  and
     password  truncation if the authentication algorithm is HMAC-MD5-128. Those
     hitting this issue may see "username invalid", "password invalid", or  "k_g
     invalid"  errors.	Issue observed on Intel SE7520AF2 with Intel Server Man-
     agement Module (Professional Edition).

     supermicro20 - This workaround flag will  work  around  several  Supermicro
     IPMI  2.0 authentication issues on motherboards w/ Peppercon IPMI firmware.
     The issues covered include handling invalid  length  authentication  codes.
     Those hitting this issue may see "password invalid" errors.  Issue observed
     on  Supermicro  H8QME with SIMSO daughter card. Confirmed fixed on newerver
     firmware.

     sun20 - This workaround flag will work work around several Sun IPMI 2.0 au-
     thentication issues. The issues covered include invalid lengthed hash keys,
     improperly hashed keys, and invalid cipher  suite	records.  Those  hitting
     this  issue  may  see  "password invalid" or "bmc error" errors.  Issue ob-
     served on Sun Fire 4100/4200/4500 with ILOM.  This workaround automatically
     includes the "opensesspriv" workaround.

     opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI 2.0
     connection protocol to workaround an invalid hashing algorithm used by  the
     remote system. The privilege level sent during the Open Session stage of an
     IPMI 2.0 connection is used for hashing keys instead of the privilege level
     sent  during  the	RAKP1 connection stage. Those hitting this issue may see
     "password invalid", "k_g invalid", "bad rmcpplus status code",  or  "privi-
     lege level cannot be obtained for this user" errors.  Issue observed on Sun
     Fire  4100/4200/4500  with  ILOM,	Inventec 5441/Dell Xanadu II, Supermicro
     X8DTH,  Supermicro  X8DTG,  Intel	S5500WBV/Penguin   Relion   700,   Intel
     S2600JF/Appro  512X,  Quanta  QSSC-S4R/Appro GB812X-CN, Dell C5220, and the
     OpenIPMI software BMC. This workaround is automatically triggered with  the
     "sun20" workaround.

     integritycheckvalue  - This workaround flag will work around an invalid in-
     tegrity check value during an IPMI 2.0 session establishment when using Ci-
     pher Suite ID 0. The integrity check value should be 0 length, however  the
     remote  motherboard responds with a non-empty field. Those hitting this is-
     sue may see "k_g invalid" errors. Issue observed on Supermicro  X8DTG,  Su-
     permicro	X8DTU,	 and   Intel  S5500WBV/Penguin	Relion	700,  and  Intel
     S2600JF/Appro 512X.

     assumemaxsdrrecordcount - This workaround will inform SDR reading	to  stop
     reading  after  a	known maximum number of SDR records have been read. This
     will work around systems that have miss-implemented SDR reading  functions.
     Those  hitting  this issue may see "SDR record count invalid" errors. Issue
     observed on unspecified Inspur motherboard.

     No IPMI 1.5 Support - Some motherboards that support  IPMI  2.0  have  been
     found  to	not support IPMI 1.5. Those hitting this issue may see "ipmi 2.0
     unavailable" or "connection timeout"  errors.  This  issue  can  be  worked
     around  by  using	IPMI  2.0  instead  of	IPMI  1.5  by  specifying --dri-
     ver-type=LAN_2_0. Issue observed on a number of HP and  Supermicro  mother-
     boards.

DIAGNOSTICS
     Upon successful execution, exit status is 0. On error, exit status is 1.

     If  multiple hosts are specified for communication, the exit status is 0 if
     and only if all targets successfully execute. Otherwise the exit status  is
     1.

KNOWN ISSUES
     On older operating systems, if you input your username, password, and other
     potentially  security relevant information on the command line, this infor-
     mation may be discovered by other users when using  tools	like  the  ps(1)
     command or looking in the /proc file system. It is generally more secure to
     input  password information with options like the -P or -K options. Config-
     uring security relevant information  in  the  FreeIPMI  configuration  file
     would also be an appropriate way to hide this information.

     In  order	to prevent brute force attacks, some BMCs will temporarily "lock
     up" after a number of remote authentication errors. You may  need	to  wait
     awhile  in order to this temporary "lock up" to pass before you may authen-
     ticate again.

REPORTING BUGS
     Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
     Copyright (C) 2008-2015 FreeIPMI Core Team

     This program is free software; you can redistribute it and/or modify it un-
     der the terms of the GNU General Public License as published  by  the  Free
     Software  Foundation;  either version 3 of the License, or (at your option)
     any later version.

SEE ALSO
     freeipmi(7), ipmi-config(8), ipmi-raw(8)

     http://www.gnu.org/software/freeipmi/