IPMI-SEL(8)			 System Commands		     IPMI-SEL(8)

NAME
     ipmi-sel - display SEL entries

SYNOPSIS
     ipmi-sel [OPTION...]

DESCRIPTION
     Ipmi-sel  is  used  to  view and manage System Event Log (SEL) entries. SEL
     records store system event information and  may  be  useful  for  debugging
     problems.

     Ipmi-sel  does not inform the user if an event is particularly good or bad,
     just  that  the  event  occurred.	Users  may  wish  to  use   the   --out-
     put-event-state option to output the analyzed state.

     Listed  below  are  general  IPMI	options,  tool specific options, trouble
     shooting information, workaround information, examples, and  known  issues.
     For  a general introduction to FreeIPMI please see freeipmi(7).  To perform
     some advanced SEL management, please see bmc-device(8).

GENERAL OPTIONS
     The following options are general options for configuring	IPMI  communica-
     tion and executing general tool commands.

     -D IPMIDRIVER, --driver-type=IPMIDRIVER
	    Specify  the  driver type to use instead of doing an auto selection.
	    The currently available outofband drivers are LAN and LAN_2_0, which
	    perform IPMI 1.5 and IPMI 2.0 respectively. The currently  available
	    inband drivers are KCS, SSIF, OPENIPMI, SUNBMC, and INTELDCMI.

     --disable-auto-probe
	    Do not probe in-band IPMI devices for default settings.

     --driver-address=DRIVER-ADDRESS
	    Specify  the in-band driver address to be used instead of the probed
	    value. DRIVER-ADDRESS should be prefixed with "0x" for a  hex  value
	    and '0' for an octal value.

     --driver-device=DEVICE
	    Specify  the  in-band  driver  device path to be used instead of the
	    probed path.

     --register-spacing=REGISTER-SPACING
	    Specify the in-band driver register spacing instead  of  the  probed
	    value. Argument is in bytes (i.e. 32bit register spacing = 4)

     --target-channel-number=CHANNEL-NUMBER
	    Specify  the  in-band  driver target channel number to send IPMI re-
	    quests to.

     --target-slave-address=SLAVE-ADDRESS
	    Specify the in-band driver target slave number to send IPMI requests
	    to.

     -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMI-
     HOST2[:PORT],...
	    Specify the remote host(s) to communicate with.  Multiple  hostnames
	    may be separated by comma or may be specified in a range format; see
	    HOSTRANGED	SUPPORT  below.  An  optional port can be specified with
	    each host, which may be useful in port forwarding or similar  situa-
	    tions.   If specifying an IPv6 address and port, use the format [AD-
	    DRESS]:PORT.

     -u USERNAME, --username=USERNAME
	    Specify the username to use  when  authenticating  with  the  remote
	    host.   If	not  specified,  a null (i.e. anonymous) username is as-
	    sumed. The user must have atleast USER privileges in order for  this
	    tool to operate fully.

     -p PASSWORD, --password=PASSWORD
	    Specify  the  password  to	use when authenticationg with the remote
	    host.  If not specified, a null password is assumed.  Maximum  pass-
	    word length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

     -P, --password-prompt
	    Prompt  for  password  to avoid possibility of listing it in process
	    lists.

     -k K_G, --k-g=K_G
	    Specify the K_g BMC key to use when authenticating with  the  remote
	    host for IPMI 2.0. If not specified, a null key is assumed. To input
	    the  key in hexadecimal form, prefix the string with '0x'. E.g., the
	    key 'abc' can be entered with the either the  string  'abc'  or  the
	    string '0x616263'

     -K, --k-g-prompt
	    Prompt for k-g to avoid possibility of listing it in process lists.

     --session-timeout=MILLISECONDS
	    Specify  the session timeout in milliseconds. Defaults to 20000 mil-
	    liseconds (20 seconds) if not specified.

     --retransmission-timeout=MILLISECONDS
	    Specify the packet retransmission timeout in milliseconds.	Defaults
	    to 1000 milliseconds (1 second) if not specified. The retransmission
	    timeout cannot be larger than the session timeout.

     -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
	    Specify  the  IPMI	1.5  authentication  type  to use. The currently
	    available authentication types are NONE, STRAIGHT_PASSWORD_KEY, MD2,
	    and MD5. Defaults to MD5 if not specified.

     -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
	    Specify the IPMI 2.0 cipher suite ID to use.  The  Cipher  Suite  ID
	    identifies	a  set of authentication, integrity, and confidentiality
	    algorithms to use for IPMI 2.0 communication. The authentication al-
	    gorithm identifies the algorithm to use for session setup,	the  in-
	    tegrity algorithm identifies the algorithm to use for session packet
	    signatures,  and  the confidentiality algorithm identifies the algo-
	    rithm to use for payload encryption. Defaults to cipher suite  ID  3
	    if	not specified. The following cipher suite ids are currently sup-
	    ported:

	    0 - Authentication Algorithm = None;  Integrity  Algorithm	=  None;
	    Confidentiality Algorithm = None

	    1  -  Authentication  Algorithm  =	HMAC-SHA1; Integrity Algorithm =
	    None; Confidentiality Algorithm = None

	    2 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm  =
	    HMAC-SHA1-96; Confidentiality Algorithm = None

	    3  -  Authentication  Algorithm  =	HMAC-SHA1; Integrity Algorithm =
	    HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

	    6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None;
	    Confidentiality Algorithm = None

	    7 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = None

	    8 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    11 - Authentication Algorithm  =  HMAC-MD5;  Integrity  Algorithm  =
	    MD5-128; Confidentiality Algorithm = None

	    12	-  Authentication  Algorithm  =  HMAC-MD5; Integrity Algorithm =
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    15 - Authentication Algorithm = HMAC-SHA256; Integrity  Algorithm  =
	    None; Confidentiality Algorithm = None

	    16	-  Authentication Algorithm = HMAC-SHA256; Integrity Algorithm =
	    HMAC_SHA256_128; Confidentiality Algorithm = None

	    17 - Authentication Algorithm = HMAC-SHA256; Integrity  Algorithm  =
	    HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

     -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	    Specify  the  privilege  level  to	be used. The currently available
	    privilege levels are USER, OPERATOR, and ADMIN. Defaults to OPERATOR
	    if not specified.

     --config-file=FILE
	    Specify an alternate configuration file.

     -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	    Specify  workarounds   to	vendor	 compliance   issues.	Multiple
	    workarounds  can be specified separated by commas. A special command
	    line flag of "none", will indicate no workarounds (may be useful for
	    overriding configured defaults). See WORKAROUNDS below for a list of
	    available workarounds.

     --debug
	    Turn on debugging.

     -?, --help
	    Output a help list and exit.

     --usage
	    Output a usage message and exit.

     -V, --version
	    Output the program version and exit.

IPMI-SEL OPTIONS
     The following options are specific to ipmi-sel.

     -v     Output verbose output. This  option  will  output  event  direction.
	    Event direction may be useful to differentiate severity between some
	    events.  For example, some motherboards may issue an event both when
	    a temperature exceeds a threshold and when it goes back  down  below
	    it.

     -vv    Output  very  verbose output. This option will output additional in-
	    formation than verbose output. Most notably  it  will  output  addi-
	    tional hex codes to given information on ambiguous SEL entries, such
	    as OEM codes. For example, it will output Generator ID hex codes for
	    sensors  without  names, event type codes for OEM events, and record
	    types for OEM records. This information may be  useful  if	you  are
	    writing a parser outside of ipmi-sel to interpret OEM information.

     -i, --info
	    Show general information about the SEL.

     --display=RECORD-IDS-LIST
	    Display  SEL  records by record id. Accepts space or comma separated
	    lists.

     --exclude-display=RECORD-IDS-LIST
	    Exclude display of SEL records by record id. Accepts space or  comma
	    separated lists.

     --display-range=START-END
	    Display SEL records from record id START to END.

     --exclude-display-range=START-END
	    Exclude display of SEL records from record id START to END.

     --date-range=DATE-DATE
	    Display  SEL  records  with  events  occurring in the specified date
	    range.  Dates may be specified in MM/DD/YYYY, MM-DD-YYYY or the  ISO
	    8601  YYYY-MM-DDTHH:MM:SS  format. For the non ISO 8601 formats, the
	    month may be specified as a numeral or its abbreviated string  name.
	    The current local system time can be specified with "now". Note that
	    non-timestamped  records will not be displayed automatically because
	    they do not possess a timestamp.

     --exclude-date-range=DATE-DATE
	    Exclude display of SEL records with events occurring in  the  speci-
	    fied date range. Dates may be specified in MM/DD/YYYY, MM-DD-YYYY or
	    the  ISO  8601 YYYY-MM-DDTHH:MM:SS format. For the non ISO 8601 for-
	    mats, the month may be specified as a  numeral  or	its  abbreviated
	    string  name.  The	current  local system time can be specified with
	    "now".  Note that non-timestamped records will be displayed automat-
	    ically because they do not possess a timestamp.

     -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
	    Specify sensor types to show SEL events for. Multiple types  can  be
	    separated by commas or spaces. A special command line type of "all",
	    will  indicate all types should be shown (may be useful for overrid-
	    ing configured defaults). Users may specify sensor types  by  string
	    (see --list-sensor-types below) or by number (decimal or hex).

     -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
	    Specify  sensor types to not show SEL events for. Multiple types can
	    be separated by commas or spaces. A special  command  line	type  of
	    "none", will indicate no types should be excluded (may be useful for
	    overriding	configured  defaults). Users may specify sensor types by
	    string (see --list-sensor-types below)  or	by  number  (decimal  or
	    hex).

     -L, --list-sensor-types
	    List sensor types.

     --tail=count
	    Display  approximately the last count SEL records. The display count
	    is calculated by approximating  the  record  ids  of  the  last  SEL
	    records.  It's  correctness depends highly on the SEL implementation
	    by the vendor.

     --clear
	    Clear SEL.

     --post-clear
	    Identical to --clear, except the SEL clearing will be performed  af-
	    ter  SEL  event  records  are  displayed.  This option is useful for
	    scripting if users intend to log SEL events to another log, then im-
	    mediately clear SEL. Unlike calling --clear in another execution  of
	    ipmi-sel,  this  option will use SEL reservations to notify the user
	    if a SEL change has occurred while displaying and clearing the  SEL.
	    This can protect users from a race, where a new SEL event is unknow-
	    ingly  generated before clearing the SEL. Note that SEL reservations
	    are optionally implemented by vendors and may not  be  available  on
	    all machines.

     --delete=RECORD-IDS-LIST
	    Delete records by record id in the SEL. Accepts space or comma sepa-
	    rated lists.

     --delete-range=START-END
	    Delete record ids from START to END in the SEL.

     --system-event-only
	    Output only system event records (i.e. don't output OEM records).

     --oem-event-only
	    Output  only  OEM  event  records  (i.e.  don't  output system event
	    records).

     --output-manufacturer-id
	    For OEM SEL record types, output  the  manufacturer  ID  along  with
	    event data when available.

     --output-event-state
	    Output event state in output. This will add an additional output re-
	    porting  if an event should be viewed as NOMINAL, WARNING, or CRITI-
	    CAL.  The event state is an interpreted value based on the	configu-
	    ration  file /usr/local/etc/freeipmi/freeipmi_interpret_sel.conf and
	    the event direction.  See  freeipmi_interpret_sel.conf(5)  for  more
	    information.

     --event-state-config-file=FILE
	    Specify  an alternate event state configuration file. Option ignored
	    if --output-event-state not specified.

     --hex-dump
	    Hex-dump SEL entries.

     --interpret-oem-data
	    Attempt to interpret OEM data, such as event data, sensor  readings,
	    or	general  extra info, etc. If an OEM interpretation is not avail-
	    able, the default output will be generated. Correctness of	OEM  in-
	    terpretations cannot be guaranteed due to potential changes OEM ven-
	    dors may make in products, firmware, etc. See OEM INTERPRETATION be-
	    low for confirmed supported motherboard interpretations.

     --output-oem-event-strings
	    Some  motherboards	support  an  IPMI OEM extension that returns the
	    string output for a system event. Such string output may be  benefi-
	    cial  for  determining  the meaning behind OEM specific events. This
	    option will use the OEM event string to describe all  system  events
	    in	 the   ipmi-sel   output.  This  option  differs  from	--inter-
	    pret-oem-data option in that all system events will output the  ven-
	    dor  supplied  event  string, not just events that are OEM specific.
	    The event string may be very  different  from  the	normal	FreeIPMI
	    event  string  output. If an OEM event strings is not available, the
	    default output will be output.  This option is confirmed to work for
	    Fujitsu iRMC S1 and iRMC S2 systems.

     --entity-sensor-names
	    Output sensor names prefixed with their entity id and instance  num-
	    ber  when appropriate. This may be necessary on some motherboards to
	    help identify what sensors are referencing. For example,  a  mother-
	    board  may have multiple sensors named 'TEMP'. The entity id and in-
	    stance number may help clarify which sensor refers to "Processor  1"
	    vs. "Processor 2".

     --no-sensor-type-output
	    Do	not show sensor type output for each entry. On many systems, the
	    sensor type is redundant to the name of the sensor. This  can  espe-
	    cially be true if --entity-sensor-names is specified.  If the sensor
	    name  is  sufficient, or if the sensor type is of no interest to the
	    user, this option can be specified to condense output.

     --comma-separated-output
	    Output fields in comma separated format.

     --no-header-output
	    Do not output column headers. May be useful in scripting.

     --non-abbreviated-units
	    Output non-abbreviated units (e.g. 'Amps' instead of 'A').	May  aid
	    in disambiguation of units (e.g. 'C' for Celsius or Coulombs).

     --legacy-output
	    Output  in	legacy	format.  Newer	options may not be applicable to
	    legacy output.

SDR CACHE OPTIONS
     This tool requires access to the sensor data  repository  (SDR)  cache  for
     general  operation.  By  default, SDR data will be downloaded and cached on
     the local machine. The following options apply to the SDR cache.

     --flush-cache
	    Flush a cached version of the sensor data  repository  (SDR)  cache.
	    The  SDR  is typically cached for faster subsequent access. However,
	    it may need to be flushed and re-generated if the SDR has  been  up-
	    dated on a system.

     --quiet-cache
	    Do not output information about cache creation/deletion. May be use-
	    ful in scripting.

     --sdr-cache-recreate
	    If	the  SDR cache is out of date or invalid, automatically recreate
	    the sensor data repository (SDR) cache. This option  may  be  useful
	    for scripting purposes.

     --sdr-cache-file=FILE
	    Specify  a	specific  sensor  data repository (SDR) cache file to be
	    stored or read from. If this option is used when multiple hosts  are
	    specified, the same SDR cache file will be used for all hosts.

     --sdr-cache-directory=DIRECTORY
	    Specify  an  alternate  directory  for  sensor data repository (SDR)
	    caches to be stored or read from. Defaults to the home directory  if
	    not specified.

     --ignore-sdr-cache
	    Ignore  SDR cache related processing. May lead to incomplete or less
	    useful information being output, however it will allow functionality
	    for systems without SDRs or when the correct SDR cannot be loaded.

TIME OPTIONS
     By IPMI definition, all IPMI times and timestamps are stored in  localtime.
     However,  in  many  situations, the timestamps will not be stored in local-
     time. Whether or not a system truly  stored  the  timestamps  in  localtime
     varies on many factors, such as the vendor, BIOS, and operating system.

     The  following  options will allow the user to adjust the interpretation of
     the stored timestamps and how they should be output.

     --utc-to-localtime
	    Assume all times are reported in UTC time and convert  the	time  to
	    localtime before being output.

     --localtime-to-utc
	    Convert all localtime timestamps to UTC before being output.

     --utc-offset=SECONDS
	    Specify  a specific UTC offset in seconds to be added to timestamps.
	    Value can range from -86400 to 86400 seconds. Defaults to 0.

HOSTRANGED OPTIONS
     The following options manipulate hostranged output. See HOSTRANGED  SUPPORT
     below for additional information on hostranges.

     -B, --buffer-output
	    Buffer  hostranged output. For each node, buffer standard output un-
	    til the node has completed its IPMI operation. When specifying  this
	    option,  data  may appear to output slower to the user since the the
	    entire IPMI operation must complete before any data can  be  output.
	    See HOSTRANGED SUPPORT below for additional information.

     -C, --consolidate-output
	    Consolidate  hostranged  output.  The  complete standard output from
	    every node specified will be consolidated so that nodes with identi-
	    cal output are not output twice. A header will list those nodes with
	    the consolidated output. When this option is  specified,  no  output
	    can be seen until the IPMI operations to all nodes has completed. If
	    the user breaks out of the program early, all currently consolidated
	    output  will  be dumped. See HOSTRANGED SUPPORT below for additional
	    information.

     -F NUM, --fanout=NUM
	    Specify multiple host fanout. A "sliding window" (or  fanout)  algo-
	    rithm  is  used for parallel IPMI communication so that slower nodes
	    or timed out nodes will not impede parallel communication. The maxi-
	    mum number of threads available at the same time is limited  by  the
	    fanout. The default is 64.

     -E, --eliminate
	    Eliminate  hosts  determined  as undetected by ipmidetect.	This at-
	    tempts to remove the common issue of hostranged execution timing out
	    due to several nodes being removed from service in a large	cluster.
	    The  ipmidetectd  daemon  must  be running on the node executing the
	    command.

     --always-prefix
	    Always prefix output, even if only one host is specified or communi-
	    cating in-band. This option is primarily useful for  scripting  pur-
	    poses. Option will be ignored if specified with the -C option.

HOSTRANGED SUPPORT
     Multiple  hosts can be input either as an explicit comma separated lists of
     hosts or a range of hostnames in  the  general  form:  prefix[n-m,l-k,...],
     where n < m and l < k, etc. The later form should not be confused with reg-
     ular  expression  character  classes  (also  denoted  by  []). For example,
     foo[19] does not represent foo1 or foo9, but rather represents a degenerate
     range: foo19.

     This range syntax is meant only as a convenience on clusters  with  a  pre-
     fixNN  naming  convention and specification of ranges should not be consid-
     ered necessary -- the list foo1,foo9 could be specified as such, or by  the
     range foo[1,9].

     Some examples of range usage follow:
	 foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
	 foo[7,9-10] instead of foo7,foo9,foo10
	 foo[0-3] instead of foo0,foo1,foo2,foo3

     As  a reminder to the reader, some shells will interpret brackets ([ and ])
     for pattern matching. Depending on your shell, it may be necessary  to  en-
     close ranged lists within quotes.

     When  multiple  hosts  are specified by the user, a thread will be executed
     for each host in parallel up to the configured fanout  (which  can  be  ad-
     justed  via  the -F option). This will allow communication to large numbers
     of nodes far more quickly than if done in serial.

     By default, standard output from each node specified will	be  output  with
     the  hostname  prepended  to each line. Although this output is readable in
     many situations, it may be difficult to read in other situations. For exam-
     ple, output from multiple nodes may be mixed together. The -B  and  -C  op-
     tions can be used to change this default.

     In-band IPMI Communication will be used when the host "localhost" is speci-
     fied. This allows the user to add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING
     Most often, IPMI problems are due to configuration problems.

     IPMI  over  LAN problems involve a misconfiguration of the remote machine's
     BMC.  Double check to make sure the following are	configured  properly  in
     the  remote  machine's BMC: IP address, MAC address, subnet mask, username,
     user enablement, user privilege, password, LAN privilege,	LAN  enablement,
     and  allowed authentication type(s). For IPMI 2.0 connections, double check
     to make sure the cipher suite privilege(s) and K_g key are configured prop-
     erly. The ipmi-config(8) tool can be used to check and/or change these con-
     figuration settings.

     Inband IPMI problems are typically caused by improperly configured  drivers
     or non-standard BMCs.

     In addition to the troubleshooting tips below, please see WORKAROUNDS below
     to also if there are any vendor specific bugs that have been discovered and
     worked around.

     Listed  below  are many of the common issues for error messages.  For addi-
     tional support, please e-mail the <freeipmi-users@gnu.org> mailing list.

     "username invalid" - The username entered (or a NULL username if  none  was
     entered)  is  not	available on the remote machine. It may also be possible
     the remote BMC's username configuration is incorrect.

     "password invalid" - The password entered (or a NULL password if  none  was
     entered)  is not correct. It may also be possible the password for the user
     is not correctly configured on the remote BMC.

     "password verification timeout" - Password verification has timed	out.   A
     "password	invalid"  error (described above) or a generic "session timeout"
     (described below) occurred.  During this point in the protocol it cannot be
     differentiated which occurred.

     "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered)
     is not correct. It may also be possible the K_g key is not  correctly  con-
     figured on the remote BMC.

     "privilege  level	insufficient"  -  An IPMI command requires a higher user
     privilege than the one authenticated with. Please try to authenticate  with
     a	higher	privilege.  This  may require authenticating to a different user
     which has a higher maximum privilege.

     "privilege level cannot be obtained for this user" -  The	privilege  level
     you  are attempting to authenticate with is higher than the maximum allowed
     for this user. Please try again with a lower privilege. It may also be pos-
     sible the maximum privilege level allowed for  a  user  is  not  configured
     properly on the remote BMC.

     "authentication  type  unavailable for attempted privilege level" - The au-
     thentication type you wish to authenticate with is not available  for  this
     privilege	level. Please try again with an alternate authentication type or
     alternate privilege level. It may also be possible the available  authenti-
     cation  types you can authenticate with are not correctly configured on the
     remote BMC.

     "cipher suite id unavailable" - The cipher suite id you wish  to  authenti-
     cate  with is not available on the remote BMC. Please try again with an al-
     ternate cipher suite id. It may also be possible the available cipher suite
     ids are not correctly configured on the remote BMC.

     "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine.
     Please try to use IPMI 1.5 instead.

     "connection timeout" - Initial IPMI communication failed. A number  of  po-
     tential  errors  are  possible, including an invalid hostname specified, an
     IPMI IP address cannot be resolved, IPMI  is  not	enabled  on  the  remote
     server, the network connection is bad, etc. Please verify configuration and
     connectivity.

     "session  timeout"  - The IPMI session has timed out. Please reconnect.  If
     this error occurs often, you may wish to increase the retransmission  time-
     out. Some remote BMCs are considerably slower than others.

     "device  not found" - The specified device could not be found. Please check
     configuration or inputs and try again.

     "driver timeout" - Communication with the driver or device has  timed  out.
     Please try again.

     "message  timeout" - Communication with the driver or device has timed out.
     Please try again.

     "BMC busy" - The BMC is currently busy. It may be processing information or
     have too many simultaneous sessions to manage. Please wait and try again.

     "could not find inband device" - An  inband  device  could  not  be  found.
     Please check configuration or specify specific device or driver on the com-
     mand line.

     "driver timeout" - The inband driver has timed out communicating to the lo-
     cal  BMC  or service processor. The BMC or service processor may be busy or
     (worst case) possibly non-functioning.

     "internal IPMI error" - An IPMI error has occurred that FreeIPMI  does  not
     know  how	to  handle. Please e-mail <freeipmi-users@gnu.org> to report the
     issue.

IPMI-SEL TROUBLESHOOTING
     Some timestamps in the SEL may report a date of 1-Jan-1970, the  epoch  for
     SEL timestamps. This timestamp is not necessarily incorrect. It usually in-
     dicates  a  hardware event that occurred before a timestamp in firmware has
     been initialized. For example, certain hardware components will have  their
     internal clocks reset during a power cycle.

     However,  if  the	internal clock of the SEL appears to be regularly incor-
     rect, you may need to set the SEL time. This  can	be  done  using  bmc-de-
     vice(8).

     The following are common SEL related messages.

     "sel  config  file  parse error" - A parse error was found in the sel event
     interpretation   configuration    file.	Please	  see	 freeipmi_inter-
     pret_sel.conf(5).

WORKAROUNDS
     With  so many different vendors implementing their own IPMI solutions, dif-
     ferent vendors may implement their IPMI protocols incorrectly. The  follow-
     ing describes a number of workarounds currently available to handle discov-
     ered compliance issues. When possible, workarounds have been implemented so
     they  will  be transparent to the user. However, some will require the user
     to specify a workaround be used via the -W option.

     The hardware listed below may only indicate the hardware that a problem was
     discovered on. Newer versions of hardware may fix	the  problems  indicated
     below.  Similar machines from vendors may or may not exhibit the same prob-
     lems. Different vendors may license  their  firmware  from  the  same  IPMI
     firmware developer, so it may be worthwhile to try workarounds listed below
     even if your motherboard is not listed.

     If  you believe your hardware has an additional compliance issue that needs
     a workaround to be implemented, please contact the FreeIPMI maintainers  on
     <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

     assumeio  -  This workaround flag will assume inband interfaces communicate
     with system I/O rather than being memory-mapped. This will work around sys-
     tems that report invalid base addresses. Those hitting this issue	may  see
     "device not supported" or "could not find inband device" errors.  Issue ob-
     served on HP ProLiant DL145 G1.

     spinpoll  -  This workaround flag will inform some inband drivers (most no-
     tably the KCS driver) to spin while polling rather than putting the process
     to sleep. This may significantly improve the wall	clock  running	time  of
     tools  because  an  operating  system  scheduler's  granularity may be much
     larger than the time it takes to perform a single IPMI message transaction.
     However, by spinning, your system may be performing less useful work by not
     contexting out the tool for a more useful task.

     authcap - This workaround flag will skip early checks for username capabil-
     ities, authentication capabilities, and K_g support and allow IPMI  authen-
     tication  to  succeed.  It works around multiple issues in which the remote
     system does not properly report username capabilities, authentication capa-
     bilities, or K_g status. Those hitting this issue	may  see  "username  in-
     valid", "authentication type unavailable for attempted privilege level", or
     "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4, In-
     tel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

     nochecksumcheck  - This workaround flag will tell FreeIPMI to not check the
     checksums returned from IPMI command responses.  It  works  around  systems
     that  return invalid checksums due to implementation errors, but the packet
     is otherwise valid. Users are cautioned on the use of this  option,  as  it
     removes  validation  of packet integrity in a number of circumstances. How-
     ever, it is unlikely to be an issue in most situations. Those hitting  this
     issue may see "connection timeout", "session timeout", or "password verifi-
     cation  timeout"  errors.	On  IPMI  1.5 connections, the "noauthcodecheck"
     workaround may also needed too. Issue observed on Supermicro X9SCM-iiF, Su-
     permicro X9DRi-F, and Supermicro X9DRFR.

     idzero - This workaround flag will allow empty session IDs to  be	accepted
     by  the client. It works around IPMI sessions that report empty session IDs
     to the client. Those hitting this issue may see "session  timeout"  errors.
     Issue observed on Tyan S2882 with M3289 BMC.

     unexpectedauth  - This workaround flag will allow unexpected non-null auth-
     codes to be checked as though they were expected. It works around an  issue
     when  packets contain non-null authentication data when they should be null
     due to disabled per-message authentication. Those hitting	this  issue  may
     see "session timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425.
     Confirmed fixed on newer firmware.

     forcepermsg - This workaround flag will force per-message authentication to
     be  used no matter what is advertised by the remote system. It works around
     an issue when per-message authentication is advertised as disabled  on  the
     remote  system, but it is actually required for the protocol. Those hitting
     this issue may see "session timeout" errors.  Issue observed on IBM eServer
     325.

     endianseq - This workaround flag will flip the endian of  the  session  se-
     quence  numbers  to allow the session to continue properly. It works around
     IPMI 1.5 session sequence numbers that are the wrong endian.  Those hitting
     this issue may see "session timeout" errors. Issue  observed  on  some  Sun
     ILOM 1.0/2.0 (depends on service processor endian).

     noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the
     authentication codes returned from IPMI 1.5  command  responses.  It  works
     around  systems  that return invalid authentication codes due to hashing or
     implementation errors. Users are cautioned on the use of this option, as it
     removes an authentication check verifying the validity of	a  packet.  How-
     ever, in most organizations, this is unlikely to be a security issue. Those
     hitting  this  issue  may	see  "connection timeout", "session timeout", or
     "password verification timeout" errors.   Issue  observed	on  Xyratex  FB-
     H8-SRAY, Intel Windmill, Quanta Winterfell, and Wiwynn Windmill.

     intel20  - This workaround flag will work around several Intel IPMI 2.0 au-
     thentication issues. The issues covered include padding of  usernames,  and
     password  truncation if the authentication algorithm is HMAC-MD5-128. Those
     hitting this issue may see "username invalid", "password invalid", or  "k_g
     invalid"  errors.	Issue observed on Intel SE7520AF2 with Intel Server Man-
     agement Module (Professional Edition).

     supermicro20 - This workaround flag will  work  around  several  Supermicro
     IPMI  2.0 authentication issues on motherboards w/ Peppercon IPMI firmware.
     The issues covered include handling invalid  length  authentication  codes.
     Those hitting this issue may see "password invalid" errors.  Issue observed
     on  Supermicro  H8QME with SIMSO daughter card. Confirmed fixed on newerver
     firmware.

     sun20 - This workaround flag will work work around several Sun IPMI 2.0 au-
     thentication issues. The issues covered include invalid lengthed hash keys,
     improperly hashed keys, and invalid cipher  suite	records.  Those  hitting
     this  issue  may  see  "password invalid" or "bmc error" errors.  Issue ob-
     served on Sun Fire 4100/4200/4500 with ILOM.  This workaround automatically
     includes the "opensesspriv" workaround.

     opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI 2.0
     connection protocol to workaround an invalid hashing algorithm used by  the
     remote system. The privilege level sent during the Open Session stage of an
     IPMI 2.0 connection is used for hashing keys instead of the privilege level
     sent  during  the	RAKP1 connection stage. Those hitting this issue may see
     "password invalid", "k_g invalid", "bad rmcpplus status code",  or  "privi-
     lege level cannot be obtained for this user" errors.  Issue observed on Sun
     Fire  4100/4200/4500  with  ILOM,	Inventec 5441/Dell Xanadu II, Supermicro
     X8DTH,  Supermicro  X8DTG,  Intel	S5500WBV/Penguin   Relion   700,   Intel
     S2600JF/Appro  512X,  Quanta  QSSC-S4R/Appro GB812X-CN, Dell C5220, and the
     OpenIPMI software BMC. This workaround is automatically triggered with  the
     "sun20" workaround.

     integritycheckvalue  - This workaround flag will work around an invalid in-
     tegrity check value during an IPMI 2.0 session establishment when using Ci-
     pher Suite ID 0. The integrity check value should be 0 length, however  the
     remote  motherboard responds with a non-empty field. Those hitting this is-
     sue may see "k_g invalid" errors. Issue observed on Supermicro  X8DTG,  Su-
     permicro	X8DTU,	 and   Intel  S5500WBV/Penguin	Relion	700,  and  Intel
     S2600JF/Appro 512X.

     assumemaxsdrrecordcount - This workaround will inform SDR reading	to  stop
     reading  after  a	known maximum number of SDR records have been read. This
     will work around systems that have miss-implemented SDR reading  functions.
     Those  hitting  this issue may see "SDR record count invalid" errors. Issue
     observed on unspecified Inspur motherboard.

     assumesystemevent - This workaround option will assume invalid  SEL  record
     types  are system event records. Records may be formatted correctly but re-
     port invalid record types. Those hitting this issue may  see  "Unknown  SEL
     Record  Type" errors. Output may be unknown, pray for the best. This option
     is confirmed to work around compliances issues on	HP  DL	380  G5  mother-
     boards.

     No  IPMI  1.5  Support  - Some motherboards that support IPMI 2.0 have been
     found to not support IPMI 1.5. Those hitting this issue may see  "ipmi  2.0
     unavailable"  or  "connection  timeout"  errors.  This  issue can be worked
     around by	using  IPMI  2.0  instead  of  IPMI  1.5  by  specifying  --dri-
     ver-type=LAN_2_0.	Issue  observed on a number of HP and Supermicro mother-
     boards.

OEM INTERPRETATION
     The following motherboards are confirmed to have atleast  some  support  by
     the  --interpret-oem-data option. While highly probable the OEM data inter-
     pretations would work across other motherboards by the  same  manufacturer,
     there are no guarantees. Some of the motherboards below may be rebranded by
     vendors/distributors.

     Dell  Poweredge  2900,  Dell Poweredge 2950, Dell Poweredge R610, Dell Pow-
     eredge R710, Fujitsu iRMC S1 and iRMC S2 systems, Gigabyte MD90-FS0-ZB, Gi-
     gabyte MG20-OP0-ZB/Penguin Computing Relgion X1904GT, Intel S5500WB/Penguin
     Computing Relion  700,  Intel  S2600JF/Appro  512X,  Intel  S2600GZ,  Intel
     S2600WP, Intel S5000PAL, Intel Windmill, Intel S2600KP, Intel S2600KPR, In-
     tel  S2600WT2,  Intel  S2600WTT,  Inventec  5441/Dell  Xanadu  II, Inventec
     5442/Dell Xanadu  III,  Quanta  S99Q/Dell	FS12-TY,  Quanta  QSSC-S4R/Appro
     GB812X-CN,  Quanta  Winterfell,  Sun  X4140  Supermicro X7DBR-3, Supermicro
     X7DB8, Supermicro X8DTN, Supermicro X7SBI-LN4, Supermicro X8DTH, Supermicro
     X8DTG, Supermicro X8DTU, Supermicro X8DT3-LN4F, Supermicro X8DTU-6+, Super-
     micro X8DTL, Supermicro X8DTL-3F, Supermicro X8SIL-F, Supermicro X9SCL, Su-
     permicro X9SCM, Supermicro X8DTN+-F, Supermicro X8SIE, Supermicro	X9SCA-F-
     O, Supermicro H8DGU-F, Supermicro X9DRi-F, Supermicro X9DRI-LN4F+, Supermi-
     cro  X9SPU-F-O, Supermicro X9SCM-iiF, Supermicro X10SLM-F, Wiwynn Windmill,
     Wistron/Dell Poweredge C6220.

EXAMPLES
     # ipmi-sel

     Show all SEL records on the local machine.

     # ipmi-sel -h ahost -u myusername -p mypassword

     Show all SEL records of a remote machine using IPMI over LAN.

     # ipmi-sel -h mycluster[0-127] -u myusername -p mypassword

     Show all SEL records across a cluster using IPMI over LAN.

     # ipmi-sel --delete=44,82

     Delete SEL records 44 and 82 on the local machine.

     # ipmi-sel --delete-all

     Delete all SEL entries on the local machine.

     # ipmi-sel --delete-range=12-42

     Delete SEL entries in the range 12 to 42 on the local machine.

DIAGNOSTICS
     Upon successful execution, exit status is 0. On error, exit status is 1.

     If multiple hosts are specified for communication, the exit status is 0  if
     and  only if all targets successfully execute. Otherwise the exit status is
     1.

KNOWN ISSUES
     On older operating systems, if you input your username, password, and other
     potentially security relevant information on the command line, this  infor-
     mation  may  be  discovered  by other users when using tools like the ps(1)
     command or looking in the /proc file system. It is generally more secure to
     input password information with options like the -P or -K options.  Config-
     uring  security  relevant	information  in  the FreeIPMI configuration file
     would also be an appropriate way to hide this information.

     In order to prevent brute force attacks, some BMCs will  temporarily  "lock
     up"  after  a  number of remote authentication errors. You may need to wait
     awhile in order to this temporary "lock up" to pass before you may  authen-
     ticate again.

REPORTING BUGS
     Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
     Copyright (C) 2003-2015 FreeIPMI Core Team.

     This program is free software; you can redistribute it and/or modify it un-
     der  the  terms  of the GNU General Public License as published by the Free
     Software Foundation; either version 3 of the License, or (at  your  option)
     any later version.

SEE ALSO
     freeipmi(7),  bmc-device(8),  ipmiseld(8),  ipmi-config(8), freeipmi_inter-
     pret_sel.conf(5)

     http://www.gnu.org/software/freeipmi/

ipmi-sel 1.6.18 		   2026-06-02			     IPMI-SEL(8)