IPMI-SENSORS(8) 		 System Commands		 IPMI-SENSORS(8)

NAME
     ipmi-sensors - display IPMI sensor information

SYNOPSIS
     ipmi-sensors [OPTION...]

DESCRIPTION
     Ipmi-sensors  displays  current readings of sensors and sensor data reposi-
     tory (SDR) information. The default display outputs  each	sensor's  record
     id, sensor name, sensor type name, sensor reading (if appropriate), and the
     current  sensor event. More verbose information can be found using the ver-
     bose options specified below.

     Ipmi-sensors does not inform the user if a problem exists with a particular
     sensor because sensor readings and events	are  not  analyzed  by	default.
     Users  may  wish to use the --output-sensor-state option to output the ana-
     lyzed sensor state.

     Some sensors may have a sensor reading or sensor event of "N/A" if the  in-
     formation	is  unavailable. This is typical of a sensor that is not enabled
     or not owned by a BMC. Please see --bridge-sensors  option  below	to  deal
     with  sensors not owned by a BMC. Sensors may output a sensor event of "Un-
     known" if the sensor reading cannot be read. This is typical  of  a  sensor
     that is busy or a reading that cannot be calculated. If sensors report "Un-
     recognized State", it is indicative of an unknown sensor type, typically an
     OEM  sensor.  If  the  sensor OEM interpretation is available, the --inter-
     pret-oem-data may be able to report the appropriate sensor  state.  Sensors
     need  not always report a sensor event. When a sensor event is not present,
     "OK" is typically reported.

     Listed below are general  IPMI  options,  tool  specific  options,  trouble
     shooting  information,  workaround information, examples, and known issues.
     For a general introduction to FreeIPMI please see freeipmi(7).  To  perform
     IPMI  sensor configuration, please see ipmi-config(8).  To perform some ad-
     vanced SDR management, please see bmc-device(8).

GENERAL OPTIONS
     The following options are general options for configuring	IPMI  communica-
     tion and executing general tool commands.

     -D IPMIDRIVER, --driver-type=IPMIDRIVER
	    Specify  the  driver type to use instead of doing an auto selection.
	    The currently available outofband drivers are LAN and LAN_2_0, which
	    perform IPMI 1.5 and IPMI 2.0 respectively. The currently  available
	    inband drivers are KCS, SSIF, OPENIPMI, SUNBMC, and INTELDCMI.

     --disable-auto-probe
	    Do not probe in-band IPMI devices for default settings.

     --driver-address=DRIVER-ADDRESS
	    Specify  the in-band driver address to be used instead of the probed
	    value. DRIVER-ADDRESS should be prefixed with "0x" for a  hex  value
	    and '0' for an octal value.

     --driver-device=DEVICE
	    Specify  the  in-band  driver  device path to be used instead of the
	    probed path.

     --register-spacing=REGISTER-SPACING
	    Specify the in-band driver register spacing instead  of  the  probed
	    value. Argument is in bytes (i.e. 32bit register spacing = 4)

     --target-channel-number=CHANNEL-NUMBER
	    Specify  the  in-band  driver target channel number to send IPMI re-
	    quests to.

     --target-slave-address=SLAVE-ADDRESS
	    Specify the in-band driver target slave number to send IPMI requests
	    to.

     -h IPMIHOST1,IPMIHOST2,..., --hostname=IPMIHOST1[:PORT],IPMI-
     HOST2[:PORT],...
	    Specify the remote host(s) to communicate with.  Multiple  hostnames
	    may be separated by comma or may be specified in a range format; see
	    HOSTRANGED	SUPPORT  below.  An  optional port can be specified with
	    each host, which may be useful in port forwarding or similar  situa-
	    tions.   If specifying an IPv6 address and port, use the format [AD-
	    DRESS]:PORT.

     -u USERNAME, --username=USERNAME
	    Specify the username to use  when  authenticating  with  the  remote
	    host.   If	not  specified,  a null (i.e. anonymous) username is as-
	    sumed. The user must have atleast OPERATOR privileges in  order  for
	    this tool to operate fully.

     -p PASSWORD, --password=PASSWORD
	    Specify  the  password  to	use when authenticationg with the remote
	    host.  If not specified, a null password is assumed.  Maximum  pass-
	    word length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

     -P, --password-prompt
	    Prompt  for  password  to avoid possibility of listing it in process
	    lists.

     -k K_G, --k-g=K_G
	    Specify the K_g BMC key to use when authenticating with  the  remote
	    host for IPMI 2.0. If not specified, a null key is assumed. To input
	    the  key in hexadecimal form, prefix the string with '0x'. E.g., the
	    key 'abc' can be entered with the either the  string  'abc'  or  the
	    string '0x616263'

     -K, --k-g-prompt
	    Prompt for k-g to avoid possibility of listing it in process lists.

     --session-timeout=MILLISECONDS
	    Specify  the session timeout in milliseconds. Defaults to 20000 mil-
	    liseconds (20 seconds) if not specified.

     --retransmission-timeout=MILLISECONDS
	    Specify the packet retransmission timeout in milliseconds.	Defaults
	    to 1000 milliseconds (1 second) if not specified. The retransmission
	    timeout cannot be larger than the session timeout.

     -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
	    Specify  the  IPMI	1.5  authentication  type  to use. The currently
	    available authentication types are NONE, STRAIGHT_PASSWORD_KEY, MD2,
	    and MD5. Defaults to MD5 if not specified.

     -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
	    Specify the IPMI 2.0 cipher suite ID to use.  The  Cipher  Suite  ID
	    identifies	a  set of authentication, integrity, and confidentiality
	    algorithms to use for IPMI 2.0 communication. The authentication al-
	    gorithm identifies the algorithm to use for session setup,	the  in-
	    tegrity algorithm identifies the algorithm to use for session packet
	    signatures,  and  the confidentiality algorithm identifies the algo-
	    rithm to use for payload encryption. Defaults to cipher suite  ID  3
	    if	not specified. The following cipher suite ids are currently sup-
	    ported:

	    0 - Authentication Algorithm = None;  Integrity  Algorithm	=  None;
	    Confidentiality Algorithm = None

	    1  -  Authentication  Algorithm  =	HMAC-SHA1; Integrity Algorithm =
	    None; Confidentiality Algorithm = None

	    2 - Authentication Algorithm  =  HMAC-SHA1;  Integrity  Algorithm  =
	    HMAC-SHA1-96; Confidentiality Algorithm = None

	    3  -  Authentication  Algorithm  =	HMAC-SHA1; Integrity Algorithm =
	    HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

	    6 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = None;
	    Confidentiality Algorithm = None

	    7 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = None

	    8 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm = HMAC-
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    11 - Authentication Algorithm  =  HMAC-MD5;  Integrity  Algorithm  =
	    MD5-128; Confidentiality Algorithm = None

	    12	-  Authentication  Algorithm  =  HMAC-MD5; Integrity Algorithm =
	    MD5-128; Confidentiality Algorithm = AES-CBC-128

	    15 - Authentication Algorithm = HMAC-SHA256; Integrity  Algorithm  =
	    None; Confidentiality Algorithm = None

	    16	-  Authentication Algorithm = HMAC-SHA256; Integrity Algorithm =
	    HMAC_SHA256_128; Confidentiality Algorithm = None

	    17 - Authentication Algorithm = HMAC-SHA256; Integrity  Algorithm  =
	    HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

     -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
	    Specify  the  privilege  level  to	be used. The currently available
	    privilege levels are USER, OPERATOR, and ADMIN. Defaults to OPERATOR
	    if not specified.

     --config-file=FILE
	    Specify an alternate configuration file.

     -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
	    Specify  workarounds   to	vendor	 compliance   issues.	Multiple
	    workarounds  can be specified separated by commas. A special command
	    line flag of "none", will indicate no workarounds (may be useful for
	    overriding configured defaults). See WORKAROUNDS below for a list of
	    available workarounds.

     --debug
	    Turn on debugging.

     -?, --help
	    Output a help list and exit.

     --usage
	    Output a usage message and exit.

     -V, --version
	    Output the program version and exit.

IPMI-SENSORS OPTIONS
     The following options are specific to ipmi-sensors.

     -v, --verbose
	    Output verbose sensor output. This option will output additional in-
	    formation about sensors such as  thresholds,  ranges,  numbers,  and
	    event/reading type codes.

     -vv    Output  very verbose sensor output. This option will output more ad-
	    ditional information than the verbose  option  such  as  information
	    about events, other sensor types, and oem sensors.

     -i, --sdr-info
	    Show sensor data repository (SDR) information

     -q, --quiet-readings
	    Do	not output sensor reading values by default. This option is par-
	    ticularly useful if you want to use hostranged output across a clus-
	    ter and want to consolidate the output.

     -r RECORD-IDS-LIST, --record-ids=RECORD-IDS-LIST
	    Specify sensors to show by record id. Multiple  record  ids  can  be
	    separated  by  commas  or  spaces.	If  both --record-ids and --sen-
	    sor-types are specified, --record-ids takes  precedence.  A  special
	    command line record id of "all", will indicate all record ids should
	    be shown (may be useful for overriding configured defaults).

     -R RECORD-IDS-LIST, --exclude-record-ids=RECORD-IDS-LIST
	    Specify sensors to not show by record id. Multiple record ids can be
	    separated  by  commas or spaces. A special command line record id of
	    "none", will indicate no record ids should be excluded (may be  use-
	    ful for overriding configured defaults).

     -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
	    Specify sensor types to show outputs for. Multiple types can be sep-
	    arated  by commas or spaces. If both --record-ids and --sensor-types
	    are specified, --record-ids takes  precedence.   A	special  command
	    line  type of "all", will indicate all types should be shown (may be
	    useful for overriding configured defaults). Users may specify sensor
	    types by string (see --list-sensor-types below) or by number  (deci-
	    mal or hex).

     -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
	    Specify  sensor types to not show outputs for. Multiple types can be
	    eparated by commas or spaces. A special command line type of "none",
	    will indicate no types should be excluded (may be useful  for  over-
	    riding  configured	defaults).  Users  may	specify  sensor types by
	    string (see --list-sensor-types below)  or	by  number  (decimal  or
	    hex).

     -L, --list-sensor-types
	    List sensor types.

     -b, --bridge-sensors
	    By	default,  sensors readings are not attempted for sensors on non-
	    BMC owners. By setting this option, sensor requests can  be  bridged
	    to	non-BMC  owners to obtain sensor readings. Bridging may not work
	    on some interfaces/driver types.

     --shared-sensors
	    Some sensors share the same sensor data record (SDR). This is  typi-
	    cally utilized for system event log (SEL) entries and not for sensor
	    readings. However, there may be some motherboards in which this for-
	    mat  is utilized for multiple active sensors, or the user simply has
	    interest in seeing the permutation of entries shared by a SDR entry.
	    By setting this option, each sensor number shared by a  record  will
	    be iterated over and output.

     --interpret-oem-data
	    Attempt  to interpret OEM data, such as event data, sensor readings,
	    or general extra info, etc. If an OEM interpretation is  not  avail-
	    able,  the	default output will be generated. Correctness of OEM in-
	    terpretations cannot be guaranteed due to potential changes OEM ven-
	    dors may make in products, firmware, etc. See OEM INTERPRETATION be-
	    low for confirmed supported motherboard interpretations.

     --ignore-not-available-sensors
	    Ignore not-available (i.e. N/A) sensors in output.

     --ignore-unrecognized-events
	    Ignore unrecognized sensor events. This will suppress output of  un-
	    recognized	events,  typically shown as 'Unrecognized Event = XXXXh'
	    in output. In addition, unrecognized events  will  be  ignored  when
	    calculating sensor state with --output-sensor-state below.

     --output-event-bitmask
	    Output event bitmask value instead of the string representation.

     --output-sensor-state
	    Output  sensor  state  in output. This will add an additional output
	    reporting if a sensor is in a NOMINAL, WARNING, or	CRITICAL  state.
	    The sensor state is an interpreted value based on the current sensor
	    event.  The  sensor state interpretations are determined by the con-
	    figuration	 file	 /usr/local/etc/freeipmi/freeipmi_interpret_sen-
	    sor.conf.	See  freeipmi_interpret_sensor.conf(5) for more informa-
	    tion.  This option gives identical output to the sensor state previ-
	    ously output by ipmimonitoring(8).

     --sensor-state-config-file=FILE
	    Specify an alternate sensor state configuration file. Option ignored
	    if --output-sensor-state not specified.

     --entity-sensor-names
	    Output sensor names prefixed with their entity id and instance  num-
	    ber  when appropriate. This may be necessary on some motherboards to
	    help identify what sensors are referencing. For example,  a  mother-
	    board  may have multiple sensors named 'TEMP'. The entity id and in-
	    stance number may help clarify which sensor refers to "Processor  1"
	    vs. "Processor 2".

     --output-sensor-thresholds
	    Output sensor thresholds in output. This will add columns to the de-
	    fault  output  for lower non-recoverable, lower critical, lower non-
	    critical, upper non-critical, upper critical, and upper non-recover-
	    able thresholds.

     --no-sensor-type-output
	    Do not show sensor type output for each entry. On many systems,  the
	    sensor  type  is redundant to the name of the sensor. This can espe-
	    cially be true if --entity-sensor-names is specified.  If the sensor
	    name is sufficient, or if the sensor type is of no interest  to  the
	    user, this option can be specified to condense output.

     --comma-separated-output
	    Output fields in comma separated format.

     --no-header-output
	    Do not output column headers. May be useful in scripting.

     --non-abbreviated-units
	    Output  non-abbreviated  units (e.g. 'Amps' instead of 'A'). May aid
	    in disambiguation of units (e.g. 'C' for Celsius or Coulombs).

     --legacy-output
	    Output in legacy format. Newer options  may  not  be  applicable  to
	    legacy output.

     --ipmimonitoring-legacy-output
	    Output  legacy  format  of legacy ipmimonitoring tool. Newer options
	    may not be applicable to legacy output.

SDR CACHE OPTIONS
     This tool requires access to the sensor data  repository  (SDR)  cache  for
     general  operation.  By  default, SDR data will be downloaded and cached on
     the local machine. The following options apply to the SDR cache.

     --flush-cache
	    Flush a cached version of the sensor data  repository  (SDR)  cache.
	    The  SDR  is typically cached for faster subsequent access. However,
	    it may need to be flushed and re-generated if the SDR has  been  up-
	    dated on a system.

     --quiet-cache
	    Do not output information about cache creation/deletion. May be use-
	    ful in scripting.

     --sdr-cache-recreate
	    If	the  SDR cache is out of date or invalid, automatically recreate
	    the sensor data repository (SDR) cache. This option  may  be  useful
	    for scripting purposes.

     --sdr-cache-file=FILE
	    Specify  a	specific  sensor  data repository (SDR) cache file to be
	    stored or read from. If this option is used when multiple hosts  are
	    specified, the same SDR cache file will be used for all hosts.

     --sdr-cache-directory=DIRECTORY
	    Specify  an  alternate  directory  for  sensor data repository (SDR)
	    caches to be stored or read from. Defaults to the home directory  if
	    not specified.

TIME OPTIONS
     By  IPMI definition, all IPMI times and timestamps are stored in localtime.
     However, in many situations, the timestamps will not be  stored  in  local-
     time.  Whether  or  not  a  system truly stored the timestamps in localtime
     varies on many factors, such as the vendor, BIOS, and operating system.

     The following options will allow the user to adjust the  interpretation  of
     the stored timestamps and how they should be output.

     --utc-to-localtime
	    Assume  all  times	are reported in UTC time and convert the time to
	    localtime before being output.

     --localtime-to-utc
	    Convert all localtime timestamps to UTC before being output.

     --utc-offset=SECONDS
	    Specify a specific UTC offset in seconds to be added to  timestamps.
	    Value can range from -86400 to 86400 seconds. Defaults to 0.

HOSTRANGED OPTIONS
     The  following options manipulate hostranged output. See HOSTRANGED SUPPORT
     below for additional information on hostranges.

     -B, --buffer-output
	    Buffer hostranged output. For each node, buffer standard output  un-
	    til  the node has completed its IPMI operation. When specifying this
	    option, data may appear to output slower to the user since	the  the
	    entire  IPMI  operation must complete before any data can be output.
	    See HOSTRANGED SUPPORT below for additional information.

     -C, --consolidate-output
	    Consolidate hostranged output. The	complete  standard  output  from
	    every node specified will be consolidated so that nodes with identi-
	    cal output are not output twice. A header will list those nodes with
	    the  consolidated  output.	When this option is specified, no output
	    can be seen until the IPMI operations to all nodes has completed. If
	    the user breaks out of the program early, all currently consolidated
	    output will be dumped. See HOSTRANGED SUPPORT below  for  additional
	    information.

     -F NUM, --fanout=NUM
	    Specify  multiple  host fanout. A "sliding window" (or fanout) algo-
	    rithm is used for parallel IPMI communication so that  slower  nodes
	    or timed out nodes will not impede parallel communication. The maxi-
	    mum  number  of threads available at the same time is limited by the
	    fanout. The default is 64.

     -E, --eliminate
	    Eliminate hosts determined as undetected by  ipmidetect.   This  at-
	    tempts to remove the common issue of hostranged execution timing out
	    due  to several nodes being removed from service in a large cluster.
	    The ipmidetectd daemon must be running on  the  node  executing  the
	    command.

     --always-prefix
	    Always prefix output, even if only one host is specified or communi-
	    cating  in-band.  This option is primarily useful for scripting pur-
	    poses. Option will be ignored if specified with the -C option.

HOSTRANGED SUPPORT
     Multiple hosts can be input either as an explicit comma separated lists  of
     hosts  or	a  range  of hostnames in the general form: prefix[n-m,l-k,...],
     where n < m and l < k, etc. The later form should not be confused with reg-
     ular expression character	classes  (also	denoted  by  []).  For	example,
     foo[19] does not represent foo1 or foo9, but rather represents a degenerate
     range: foo19.

     This  range  syntax  is meant only as a convenience on clusters with a pre-
     fixNN naming convention and specification of ranges should not  be  consid-
     ered  necessary -- the list foo1,foo9 could be specified as such, or by the
     range foo[1,9].

     Some examples of range usage follow:
	 foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
	 foo[7,9-10] instead of foo7,foo9,foo10
	 foo[0-3] instead of foo0,foo1,foo2,foo3

     As a reminder to the reader, some shells will interpret brackets ([ and  ])
     for  pattern  matching. Depending on your shell, it may be necessary to en-
     close ranged lists within quotes.

     When multiple hosts are specified by the user, a thread  will  be	executed
     for  each	host  in  parallel up to the configured fanout (which can be ad-
     justed via the -F option). This will allow communication to  large  numbers
     of nodes far more quickly than if done in serial.

     By  default,  standard  output from each node specified will be output with
     the hostname prepended to each line. Although this output	is  readable  in
     many situations, it may be difficult to read in other situations. For exam-
     ple,  output  from  multiple nodes may be mixed together. The -B and -C op-
     tions can be used to change this default.

     In-band IPMI Communication will be used when the host "localhost" is speci-
     fied. This allows the user to add the localhost into the hostranged output.

GENERAL TROUBLESHOOTING
     Most often, IPMI problems are due to configuration problems.

     IPMI over LAN problems involve a misconfiguration of the  remote  machine's
     BMC.   Double  check  to make sure the following are configured properly in
     the remote machine's BMC: IP address, MAC address, subnet	mask,  username,
     user  enablement,	user privilege, password, LAN privilege, LAN enablement,
     and allowed authentication type(s). For IPMI 2.0 connections, double  check
     to make sure the cipher suite privilege(s) and K_g key are configured prop-
     erly. The ipmi-config(8) tool can be used to check and/or change these con-
     figuration settings.

     Inband  IPMI problems are typically caused by improperly configured drivers
     or non-standard BMCs.

     In addition to the troubleshooting tips below, please see WORKAROUNDS below
     to also if there are any vendor specific bugs that have been discovered and
     worked around.

     Listed below are many of the common issues for error messages.   For  addi-
     tional support, please e-mail the <freeipmi-users@gnu.org> mailing list.

     "username	invalid"  - The username entered (or a NULL username if none was
     entered) is not available on the remote machine. It may  also  be	possible
     the remote BMC's username configuration is incorrect.

     "password	invalid"  - The password entered (or a NULL password if none was
     entered) is not correct. It may also be possible the password for the  user
     is not correctly configured on the remote BMC.

     "password	verification  timeout" - Password verification has timed out.  A
     "password invalid" error (described above) or a generic  "session	timeout"
     (described below) occurred.  During this point in the protocol it cannot be
     differentiated which occurred.

     "k_g invalid" - The K_g key entered (or a NULL K_g key if none was entered)
     is  not  correct. It may also be possible the K_g key is not correctly con-
     figured on the remote BMC.

     "privilege level insufficient" - An IPMI command  requires  a  higher  user
     privilege	than the one authenticated with. Please try to authenticate with
     a higher privilege. This may require authenticating  to  a  different  user
     which has a higher maximum privilege.

     "privilege  level	cannot	be obtained for this user" - The privilege level
     you are attempting to authenticate with is higher than the maximum  allowed
     for this user. Please try again with a lower privilege. It may also be pos-
     sible  the  maximum  privilege  level  allowed for a user is not configured
     properly on the remote BMC.

     "authentication type unavailable for attempted privilege level" -	The  au-
     thentication  type  you wish to authenticate with is not available for this
     privilege level. Please try again with an alternate authentication type  or
     alternate	privilege level. It may also be possible the available authenti-
     cation types you can authenticate with are not correctly configured on  the
     remote BMC.

     "cipher  suite  id unavailable" - The cipher suite id you wish to authenti-
     cate with is not available on the remote BMC. Please try again with an  al-
     ternate cipher suite id. It may also be possible the available cipher suite
     ids are not correctly configured on the remote BMC.

     "ipmi 2.0 unavailable" - IPMI 2.0 was not discovered on the remote machine.
     Please try to use IPMI 1.5 instead.

     "connection  timeout"  - Initial IPMI communication failed. A number of po-
     tential errors are possible, including an invalid	hostname  specified,  an
     IPMI  IP  address	cannot	be  resolved,  IPMI is not enabled on the remote
     server, the network connection is bad, etc. Please verify configuration and
     connectivity.

     "session timeout" - The IPMI session has timed out. Please  reconnect.   If
     this  error occurs often, you may wish to increase the retransmission time-
     out. Some remote BMCs are considerably slower than others.

     "device not found" - The specified device could not be found. Please  check
     configuration or inputs and try again.

     "driver  timeout"	- Communication with the driver or device has timed out.
     Please try again.

     "message timeout" - Communication with the driver or device has timed  out.
     Please try again.

     "BMC busy" - The BMC is currently busy. It may be processing information or
     have too many simultaneous sessions to manage. Please wait and try again.

     "could  not  find	inband	device"  -  An inband device could not be found.
     Please check configuration or specify specific device or driver on the com-
     mand line.

     "driver timeout" - The inband driver has timed out communicating to the lo-
     cal BMC or service processor. The BMC or service processor may be	busy  or
     (worst case) possibly non-functioning.

     "internal	IPMI  error" - An IPMI error has occurred that FreeIPMI does not
     know how to handle. Please e-mail <freeipmi-users@gnu.org>  to  report  the
     issue.

     "sensor  config  file  parse error" - A parse error was found in the sensor
     interpretation  configuration  file.  Please  see	 freeipmi_interpret_sen-
     sor.conf(5).

WORKAROUNDS
     With  so many different vendors implementing their own IPMI solutions, dif-
     ferent vendors may implement their IPMI protocols incorrectly. The  follow-
     ing describes a number of workarounds currently available to handle discov-
     ered compliance issues. When possible, workarounds have been implemented so
     they  will  be transparent to the user. However, some will require the user
     to specify a workaround be used via the -W option.

     The hardware listed below may only indicate the hardware that a problem was
     discovered on. Newer versions of hardware may fix	the  problems  indicated
     below.  Similar machines from vendors may or may not exhibit the same prob-
     lems. Different vendors may license  their  firmware  from  the  same  IPMI
     firmware developer, so it may be worthwhile to try workarounds listed below
     even if your motherboard is not listed.

     If  you believe your hardware has an additional compliance issue that needs
     a workaround to be implemented, please contact the FreeIPMI maintainers  on
     <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

     assumeio  -  This workaround flag will assume inband interfaces communicate
     with system I/O rather than being memory-mapped. This will work around sys-
     tems that report invalid base addresses. Those hitting this issue	may  see
     "device not supported" or "could not find inband device" errors.  Issue ob-
     served on HP ProLiant DL145 G1.

     spinpoll  -  This workaround flag will inform some inband drivers (most no-
     tably the KCS driver) to spin while polling rather than putting the process
     to sleep. This may significantly improve the wall	clock  running	time  of
     tools  because  an  operating  system  scheduler's  granularity may be much
     larger than the time it takes to perform a single IPMI message transaction.
     However, by spinning, your system may be performing less useful work by not
     contexting out the tool for a more useful task.

     authcap - This workaround flag will skip early checks for username capabil-
     ities, authentication capabilities, and K_g support and allow IPMI  authen-
     tication  to  succeed.  It works around multiple issues in which the remote
     system does not properly report username capabilities, authentication capa-
     bilities, or K_g status. Those hitting this issue	may  see  "username  in-
     valid", "authentication type unavailable for attempted privilege level", or
     "k_g invalid" errors.  Issue observed on Asus P5M2/P5MT-R/RS162-E4/RX4, In-
     tel SR1520ML/X38ML, and Sun Fire 2200/4150/4450 with ELOM.

     nochecksumcheck  - This workaround flag will tell FreeIPMI to not check the
     checksums returned from IPMI command responses.  It  works  around  systems
     that  return invalid checksums due to implementation errors, but the packet
     is otherwise valid. Users are cautioned on the use of this  option,  as  it
     removes  validation  of packet integrity in a number of circumstances. How-
     ever, it is unlikely to be an issue in most situations. Those hitting  this
     issue may see "connection timeout", "session timeout", or "password verifi-
     cation  timeout"  errors.	On  IPMI  1.5 connections, the "noauthcodecheck"
     workaround may also needed too. Issue observed on Supermicro X9SCM-iiF, Su-
     permicro X9DRi-F, and Supermicro X9DRFR.

     idzero - This workaround flag will allow empty session IDs to  be	accepted
     by  the client. It works around IPMI sessions that report empty session IDs
     to the client. Those hitting this issue may see "session  timeout"  errors.
     Issue observed on Tyan S2882 with M3289 BMC.

     unexpectedauth  - This workaround flag will allow unexpected non-null auth-
     codes to be checked as though they were expected. It works around an  issue
     when  packets contain non-null authentication data when they should be null
     due to disabled per-message authentication. Those hitting	this  issue  may
     see "session timeout" errors. Issue observed on Dell PowerEdge 2850,SC1425.
     Confirmed fixed on newer firmware.

     forcepermsg - This workaround flag will force per-message authentication to
     be  used no matter what is advertised by the remote system. It works around
     an issue when per-message authentication is advertised as disabled  on  the
     remote  system, but it is actually required for the protocol. Those hitting
     this issue may see "session timeout" errors.  Issue observed on IBM eServer
     325.

     endianseq - This workaround flag will flip the endian of  the  session  se-
     quence  numbers  to allow the session to continue properly. It works around
     IPMI 1.5 session sequence numbers that are the wrong endian.  Those hitting
     this issue may see "session timeout" errors. Issue  observed  on  some  Sun
     ILOM 1.0/2.0 (depends on service processor endian).

     noauthcodecheck  - This workaround flag will tell FreeIPMI to not check the
     authentication codes returned from IPMI 1.5  command  responses.  It  works
     around  systems  that return invalid authentication codes due to hashing or
     implementation errors. Users are cautioned on the use of this option, as it
     removes an authentication check verifying the validity of	a  packet.  How-
     ever, in most organizations, this is unlikely to be a security issue. Those
     hitting  this  issue  may	see  "connection timeout", "session timeout", or
     "password verification timeout" errors.   Issue  observed	on  Xyratex  FB-
     H8-SRAY, Intel Windmill, Quanta Winterfell, and Wiwynn Windmill.

     intel20  - This workaround flag will work around several Intel IPMI 2.0 au-
     thentication issues. The issues covered include padding of  usernames,  and
     password  truncation if the authentication algorithm is HMAC-MD5-128. Those
     hitting this issue may see "username invalid", "password invalid", or  "k_g
     invalid"  errors.	Issue observed on Intel SE7520AF2 with Intel Server Man-
     agement Module (Professional Edition).

     supermicro20 - This workaround flag will  work  around  several  Supermicro
     IPMI  2.0 authentication issues on motherboards w/ Peppercon IPMI firmware.
     The issues covered include handling invalid  length  authentication  codes.
     Those hitting this issue may see "password invalid" errors.  Issue observed
     on  Supermicro  H8QME with SIMSO daughter card. Confirmed fixed on newerver
     firmware.

     sun20 - This workaround flag will work work around several Sun IPMI 2.0 au-
     thentication issues. The issues covered include invalid lengthed hash keys,
     improperly hashed keys, and invalid cipher  suite	records.  Those  hitting
     this  issue  may  see  "password invalid" or "bmc error" errors.  Issue ob-
     served on Sun Fire 4100/4200/4500 with ILOM.  This workaround automatically
     includes the "opensesspriv" workaround.

     opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI 2.0
     connection protocol to workaround an invalid hashing algorithm used by  the
     remote system. The privilege level sent during the Open Session stage of an
     IPMI 2.0 connection is used for hashing keys instead of the privilege level
     sent  during  the	RAKP1 connection stage. Those hitting this issue may see
     "password invalid", "k_g invalid", "bad rmcpplus status code",  or  "privi-
     lege level cannot be obtained for this user" errors.  Issue observed on Sun
     Fire  4100/4200/4500  with  ILOM,	Inventec 5441/Dell Xanadu II, Supermicro
     X8DTH,  Supermicro  X8DTG,  Intel	S5500WBV/Penguin   Relion   700,   Intel
     S2600JF/Appro  512X,  Quanta  QSSC-S4R/Appro GB812X-CN, Dell C5220, and the
     OpenIPMI software BMC. This workaround is automatically triggered with  the
     "sun20" workaround.

     integritycheckvalue  - This workaround flag will work around an invalid in-
     tegrity check value during an IPMI 2.0 session establishment when using Ci-
     pher Suite ID 0. The integrity check value should be 0 length, however  the
     remote  motherboard responds with a non-empty field. Those hitting this is-
     sue may see "k_g invalid" errors. Issue observed on Supermicro  X8DTG,  Su-
     permicro	X8DTU,	 and   Intel  S5500WBV/Penguin	Relion	700,  and  Intel
     S2600JF/Appro 512X.

     assumemaxsdrrecordcount - This workaround will inform SDR reading	to  stop
     reading  after  a	known maximum number of SDR records have been read. This
     will work around systems that have miss-implemented SDR reading  functions.
     Those  hitting  this issue may see "SDR record count invalid" errors. Issue
     observed on unspecified Inspur motherboard.

     discretereading - This workaround option will allow analog sensor	readings
     (i.e.  rpm,  degrees,  etc.) to be read even if the event/reading type code
     for the sensor is for a discrete sensor (i.e. assert  vs.	deassert).  This
     option  works around poorly defined (and arguably illegal) SDR records that
     expect analog sensor readings to be read alongside discrete  sensors.  This
     option  is  confirmed  to work around issues on HP Proliant DL380 G7 and HP
     ProLiant ML310 G5 motherboards.

     ignorescanningdisabled - This workaround option will allow sensor	readings
     to  be read even if the sensor scanning bit indicates a sensor is disabled.
     This option works around motherboards that incorrectly indicate sensors  as
     disabled.	This  may  problem  may exist on your motherboard if sensors are
     listed as "N/A" even if they should be available. This option is  confirmed
     to  work  around  issues  on Dell Poweredge 2900, Dell Poweredge 2950, Dell
     Poweredge R410, Dell Poweredge R610, and HP Integrity rx3600 motherboards.

     assumebmcowner - This workaround option will allow sensor	readings  to  be
     read  if  the sensor owner is the BMC, but the reported sensor owner is not
     the BMC. Typically, sensors owned by a non-BMC sensor owner must be bridged
     (e.g. with the --bridge-sensors option),  however	if  the  non-BMC  sensor
     owner  is	invalid,  bridging  fails. This option works around motherboards
     that incorrectly report an non-BMC sensor owner by always assuming the sen-
     sor owner is the BMC. This problem may exist on your motherboard if sensors
     are listed as "N/A" even if they should be available. This option	is  con-
     firmed  to  work around issues on Fujitsu RX300 and Fujitsu RX300S2 mother-
     boards.

     altbridging - This workaround option will attempt alternate bridging  logic
     that  does  not  work  on some motherboards. This problem may exist on your
     motherboard if --bridge-sensors does not work and	sensors  are  listed  as
     "N/A"  even  if  they should be available. This option is confirmed to work
     around issues on  Lenovo  SR650  v3  motherboards	and  Lenovo  ThinkSystem
     servers.

     ignoreauthcode  -	This  workaround option will allow sensor readings to be
     read if the remote machine is invalidly  calculating  authentication  codes
     (i.e.  authentication hashes) when communicating over LAN. This problem may
     exist on your system if the error "session timeout" errors or there  is  an
     appearance of a hang.  Users are cautioned on the use of this option, as it
     removes  an  authentication  check verifying the validity of a packet. How-
     ever, in most organizations, this is unlikely to be a security  issue.  The
     ignoring  of  authentication packets is only limited to the period in which
     sensor readings are done, and not for any portion of the session  authenti-
     cation  or  session  teardown. This option is confirmed to work on Inventec
     5441/Dell Xanadu II and Inventec 5442/Dell Xanadu III.  (Note: On the above
     systems, this issue has only been observed  when  the  --bridge-sensors  is
     used.)

     No  IPMI  1.5  Support  - Some motherboards that support IPMI 2.0 have been
     found to not support IPMI 1.5. Those hitting this issue may see  "ipmi  2.0
     unavailable"  or  "connection  timeout"  errors.  This  issue can be worked
     around by	using  IPMI  2.0  instead  of  IPMI  1.5  by  specifying  --dri-
     ver-type=LAN_2_0.	Issue  observed on a number of HP and Supermicro mother-
     boards.

OEM INTERPRETATION
     The following motherboards are confirmed to have atleast  some  support  by
     the  --interpret-oem-data option. While highly probable the OEM data inter-
     pretations would work across other motherboards by the  same  manufacturer,
     there are no guarantees. Some of the motherboards below may be rebranded by
     vendors/distributors.

     Dell  Poweredge  R210,  Dell Poweredge R610, Dell Poweredge R710, Dell Pow-
     eredge R720, Fujitsu iRMC S1 and iRMC S2 systems, HP Proliant DL160 G8, In-
     tel S5500WB/Penguin Computing Relion 700, Intel S2600JF/Appro  512X,  Intel
     S2600GZ,  Intel S2600WP, Intel S5000PAL, Intel Windmill, Quanta Winterfell,
     Supermicro X7DBR-3, Supermicro X7DB8, Supermicro X8DTN,  Supermicro  X7SBI-
     LN4,  Supermicro  X8DTH,  Supermicro  X8DTG,  Supermicro  X8DTU, Supermicro
     X8DT3-LN4F, Supermicro X8DTU-6+, Supermicro X8DTL, Supermicro X8DTL-3F, Su-
     permicro X8SIL-F, Supermicro X9SCL, Supermicro X9SCM, Supermicro  X8DTN+-F,
     Supermicro  X8SIE,  Supermicro  X9SCA-F-O,  Supermicro  H8DGU-F, Supermicro
     X9DRi-F, Supermicro X9DRI-LN4F+, Supermicro  X9SPU-F-O,  Supermicro  X9SCM-
     iiF, Wiwynn Windmill, Wistron/Dell Poweredge C6220.

EXAMPLES
     # ipmi-sensors

     Show all sensors and readings on the local machine.

     # ipmi-sensors --verbose

     Show verbose sensors and readings on the local machine.

     # ipmi-sensors --record-ids="7,11,102"

     Show sensor record ids 7, 11, and 102 on the local machine.

     # ipmi-sensors --sensor-types=fan

     Show all sensors of type fan on the local machine.

     # ipmi-sensors -h ahost -u myusername -p mypassword

     Show all sensors on a remote machine using IPMI over LAN.

     # ipmi-sensors -h mycluster[0-127] -u myusername -p mypassword

     Show all sensors across a cluster using IPMI over LAN.

DIAGNOSTICS
     Upon successful execution, exit status is 0. On error, exit status is 1.

     If  multiple hosts are specified for communication, the exit status is 0 if
     and only if all targets successfully execute. Otherwise the exit status  is
     1.

KNOWN ISSUES
     On older operating systems, if you input your username, password, and other
     potentially  security relevant information on the command line, this infor-
     mation may be discovered by other users when using  tools	like  the  ps(1)
     command or looking in the /proc file system. It is generally more secure to
     input  password information with options like the -P or -K options. Config-
     uring security relevant information  in  the  FreeIPMI  configuration  file
     would also be an appropriate way to hide this information.

     In  order	to prevent brute force attacks, some BMCs will temporarily "lock
     up" after a number of remote authentication errors. You may  need	to  wait
     awhile  in order to this temporary "lock up" to pass before you may authen-
     ticate again.

     Some sensors may be output as not available (i.e. N/A) because the owner of
     the sensor is not the BMC. To attempt to bridge sensors and access  sensors
     not on the BMC, users may wish to try the -b or --bridge-sensors options.

REPORTING BUGS
     Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT
     Copyright (C) 2003-2015 FreeIPMI Core Team.

     This program is free software; you can redistribute it and/or modify it un-
     der  the  terms  of the GNU General Public License as published by the Free
     Software Foundation; either version 3 of the License, or (at  your  option)
     any later version.

SEE ALSO
     freeipmi(7),    bmc-device(8),    ipmi-config(8),	 freeipmi_interpret_sen-
     sor.conf(5)

     http://www.gnu.org/software/freeipmi/

IPMI Sensors version 1.6.18	   2026-06-02			 IPMI-SENSORS(8)

home | help