ipmi_ui(1)		Crude interface to an IPMI system	      ipmi_ui(1)

NAME
     ipmi_ui - Crude interface to an IPMI system

SYNOPSIS
     ipmiui [-dmsg] [-dmem] [-c] connection-1[connection-2]

     The connections are specified as either:

     smi smi-num

     or

     lan IP-addr port [IP-addr-2 port-2] auth privilege username password

DESCRIPTION
     The  ipmi_ui  program connects to an IPMI system, and allows access to IPMI
     entities and sensors and OpenIPMI controls.  It's rather crude, and primar-
     ily for testing OpenIPMI, but it has some use beyond that	so  it	is  pro-
     vided.

     Normally, ipmi_ui starts up in a full-screen format.  The left window shows
     the  output  of  commands,  the  right window shows the logs from OpenIPMI.
     Both windows are scrollable with page up and page down keys, press the "F1"
     key to choose the the left window to scroll, the "F2"  key  to  choose  the
     right window to scroll.

     Note  that  you  must  set your environment TERM variable properly for your
     terminal, or ipmi_ui will display garbage on the screen.

     Note that you can put two connection specifications on  the  command  line,
     and  ipmi_ui will make two connection.  You can only do this if the connec-
     tions are to the same IPMI domain through different management controllers.
     Also, each LAN connection may have two IP addresses.  These are two differ-
     ent addresses to the same management controller.  So you may have	a  total
     of  4 IP addresses to an IPMI domain, two management controllers and two IP
     adresses to each management controller.

OPTIONS
     -dmsg  Turn on message debugging, this will dump all messages  to	the  log
	    window.

     -dmem  Turn  on  memory  debugging,  this	will cause memory allocation and
	    deallocations to be checked.  When the program terminates,	it  will
	    dump all memory that was not properly freed (leaked).

     -snmp  Enable  the  SNMP  trap handler.  ipmi_ui must be compiled with SNMP
	    code enabled for this option to be available.

     -c     Run the program in command-line mode.  This is useful for scripting.
	    All output goes to standard output, there is no windowing.

     smi-num
	    The SMI number to connect to, for systems with more than  on  system
	    interface.	Generally, this is '0'.

     IP-addr
	    The IP address of the LAN interface.

     port   The UDP port of the LAN interface, general 623.

     IP-addr-2
	    Some  systems  support  multiple  IP connections, this specified the
	    second address and is optional.  If  specified,  OpenIPMI  will  use
	    both  IP  addresses  and fail over to the working one if one of them
	    fails.

     port-2
	    The port for the second IP connection, generally 623.

     auth   The  authorization	to  use  for  the  connection,	either	 "none",
	    "straight", "md5", or "md2".

     privilege
	    The  privilege to use for the connection, either "callback", "user",
	    "operator", or "admin".  Note that some IPMI  operations  will  fail
	    without the correct privilege.

     username
	    The  user  name  to use for the connection.  If using this anonymous
	    user, this should be the empty string "".

     password
	    The password to use for the connection.

ENTITIES
     Entities are listed by their entity id (the type of entity  they  are)  and
     their  entity  instance.  Entities may be active or inactive in the system,
     the standard IPMI algorithm for determining this is used.	Commands on  en-
     tities are:

     entities
	    List all the entities in the system.  The output is the entity spec-
	    ifier,  followed by an optional entity name in parenthesis, followed
	    by "present" or "not present".

     check_presence
	    For the check of presence for all entities.

     fru entity
	    List the FRU information associated with the entity.

     dump_fru is_logical device_address device_id lun private_bus channel
	    Dump raw information from the specified FRU device.

SENSORS
     Sensors define input devices that OpenIPMI can monitor.

     sensors entity
	    List all the sensors that monitor the given entity.  The  output  is
	    the  sensor  specifier  (the entity specifier followed by the sensor
	    name, with spaces converted to ~). followed by the sensor name.

     sensor sensor
	    Pull up the given sensor and display all its information.  In  full-
	    screen mode, the sensor will be re-queried every second.

     rearm global [assertion-mask deassertion-mask]
	    Rearm  the	given  sensor.	If global is 1, then the whole sensor is
	    rearmed.  If global is 0, then the assertion-mask  and  deassertion-
	    mask must be specified telling which thresholds or states to rearm.

     events_enable events scanning assertion-bitmask deassertion-bitmask
	    Enable  or disable events for the given sensor.  events turns events
	    on or off from the sensor (0 or 1).  scanning turns scanning  on  or
	    off  for  the sensor (0 or 1).  assertion-bitmask specifies the bit-
	    mask of thresholds or states that should be enabled or disabled when
	    a thrshold or state is asserted.  It is a  bunch  of  0's  and  1's,
	    where the first one is for threshold/state 0, the second for thresh-
	    old/state  1,  etc.   deassertion-bitmask  specifies  the bitmask of
	    thresholds or states that should  be  enabled  or  disabled  when  a
	    thrshold or state is deasserted.

CONTROLS
     Controls are output devices that can control things like LEDs, power, reset
     lines and such.

     controls entity
	    List  all the controls that control the given entity.  The output is
	    the control specifier (the entity specifier followed by the  control
	    name, with spaces converted to ~). followed by the control name.

     control control
	    Pull up the given control and display it's current state.

     set_control val1 [val2 ...]
	    Change the value of a control.  Note that for controls with multiple
	    values, every value must be specified.

EVENTS
     Events  are  asynchronous	messages  from sensors that tell the user that a
     sensor has done something.  Events are generally stored in a  system  event
     log (SEL); OpenIPMI will fetch the events from the SELs in the system.

     Since multiple SELs may exist, an event is specified by the MC it came from
     in  the  format "(channel addr)" and a log number.  The same log number may
     exist in multiple MCs.

     Events are displayed in the log window as they come in.   If  they  can  be
     correlated  with a sensor, they will be display with as much information as
     possible.

     delevent channel mc-addr log-num
	    Delete the given event.  Note that many SELs do not support individ-
	    ual deletes, so this may only delete the local copy  of  the  event,
	    not  the one in the SEL.  In this case, to delete events in the SEL,
	    you must delete all the events in the SEL and wait about 10  seconds
	    for OpenIPMI to do a full SEL clear.

     clear_sel
	    Delete  all  events in the SEL.  This process may take some time, so
	    if you do this and quit immediately it may not be complete.

     list_sel
	    List all events in the local copy of the SELs.  This is only the lo-
	    cal copy, if the copies in the actual have change, this won't be re-
	    flected.

     get_sel_time channel mc-num
	    Get the time in the SEL for the given MC.

MANAGMENT CONTROLLERS (MCs)
     In OpenIPMI, you normally don't deal with management controllers.	They are
     considered internal to the system.   However,  for  debugging,  information
     about them is provided.

     mcs    List all the MCs in the system and whether they are active.  MCs are
	    displayed in the format "(channel address)".

     mc channel mc-addr
	    Display  a	boatload of information about the MC, mostly coming from
	    the get device id command.

     mccmd channel mc-addr LUN NetFN Cmd [data ...]
	    Send an IPMI command to the given MC.  The MC must exist and be  ac-
	    tive to do this.

     mc_reset channel mc-addr [warm | cold]
	    Send  a  warm or cold reset command to the given MC.  The action the
	    MC takes is system-specific.

     scan channel mc-addr
	    Scan for an MC at the given address.  If the MC exists but	OpenIPMI
	    didn't know about it, it will be added.  If the MC no longer exists,
	    then it will be removed.

     mc_events_enable channel mc-num enabled
	    Enable or disable event generation for the given MC.

     mc_events_enabled channel mc-num
	    Prints out if the events are enabled for the given MC.

LAN Parameter Configuration
     OpenIPMI  has functions that make it easier to configure the LAN parameters
     of a LAN connection.  Note  that  the  LAN  parameters  have  a  lock  that
     OpenIPMI  attempts  to  use.   If you read the LAN parameters, they will be
     locked until you either write them or clear the lock.

     readlanparm channel mc-num channel
	    Read lanparm information from an MC and display it	in  the  display
	    window.

     viewlanparm
	    Show current lanparm information in the display window.

     writelanparm channel mc-num channel
	    Write the current LANPARM information to an MC.  Note that this must
	    be the MC that the parameters were read from.

     clearlanparmlock [channel mc-num channel]
	    Clear  a LANPARM lock.  If the MC is given, then the LANPARM lock is
	    directly cleared.  If not given, then the LANPARM lock for the  cur-
	    rent parms is cleared.

     setlanparm config [selector] value
	    Set  the  given  config item to the value.	The optional selector is
	    used for items that take a selector, like "auth" or any of the items
	    in "destination".

Platform Event Filter (PEF)
     OpenIPMI contains function to help manage the PEF settings on a BMC.   Note
     that  the PEF parameters have a lock that OpenIPMI attempts to use.  If you
     read the PEF parameters, they will be locked until you either write them or
     clear the lock.

     readpef channel mc-num
	    Read the PEF information from an MC.

     clearpeflock [channel mc-num]
	    Clear a PEF lock.  If the MC is given, then the PEF lock on that  MC
	    is directly cleared.  If no MC is given, then the current PEF's lock
	    is cleared.

     viewpef
	    Show current pef information in the display window.

     writepef channel mc-num
	    Write the current PEF information to an MC.

     setpef config [selector] value
	    Set  the  given  config item to the value.	The optional selector is
	    used for items that take a selector, like anything in the event fil-
	    ters, alert policies, or alert strings.

     pet connection channel ip-addr mac_addr eft-selector policy-num apt-selec-
     tor lan-dest-selector
	    Set up the connection for the domain to  send  PET	traps  from  the
	    given connection to the given IP/MAC address over the given channel.
	    This  does all the LAN and PEF configuration required to configure a
	    system to send event traps.

CONNECTIONS
     OpenIPMI can maintain multiple connections to a  single  domain.	It  will
     generally	only  use  one	of these at a time (although the other will con-
     stantly be under test).  This is the "active" connection.	 You  can  query
     and set which connection is active.

     The  connection  number  is  the connection from the command line.  You can
     specify two connections on the command line (the part beginning with "lan",
     "smi", etc.).  The first connection you specify  is  connection  zero,  the
     second is connection 1.

     is_con_active connection
	    Print out if the given connection is active or not.

     activate_con connection
	    Activate the given connection.

OTHER COMMANDS
     msg channel IPMB-addr LUN NetFN Cmd [data ...]
	    Send  an  IPMI command to the given IPMB address.  This is available
	    in case the given MC cannot be found or enabled.

     sdrs channel mc-addr do-sensors
	    Dump all the sdrs from the given MC.  If do-sensors  is  true,  then
	    dump  the  device SDR.  If it is false, dump the main SDR repository
	    on the MC.

     scan channel IPMB-addr
	    Perform an IPMB bus scan for the given IPMB, to try to detect an  MC
	    at	the given address.  IPMB bus scanning can be slow, this can help
	    speed things up if you already know the address.

     quit   Leave the program.

     reconnect
	    Attempt to disconnect and reconnect to the IPMI controller.  This is
	    primarily for testing.

     display_win
	    Set the display window (left window) for scrolling, just in case the
	    "F1" key doesn't work.

     log_win
	    Set the log window (right window) for scrolling, just  in  case  the
	    "F2" key doesn't work.

     help   Dump some terse help output about all the commands.

ERROR OUTPUT
     All error output goes to the log window.

SEE ALSO
     ipmilan(8)

KNOWN PROBLEMS
     Our name is legion.

AUTHOR
     Corey Minyard <cminyard@mvista.com>

OpenIPMI			    05/13/03			      ipmi_ui(1)