modbus_new_rtu()						modbus_new_rtu()

Name
     modbus_new_rtu - create a libmodbus context for RTU

Synopsis
     modbus_t *modbus_new_rtu(const char *device, int baud, char parity, int data_bit, int stop_bit);

Description
     The  modbus_new_rtu()  function  shall  allocate  and initialize a modbus_t
     structure to communicate in RTU mode on a serial line.

     The device argument specifies the name of the serial port	handled  by  the
     OS,  eg.  "/dev/ttyS0"  or  "/dev/ttyUSB0".  On  Windows, it's necessary to
     prepend COM name with "\.\" for COM number greater than 9, eg. "\\.\COM10".
     See http://msdn.microsoft.com/en-us/library/aa365247(v=vs.85).aspx for  de-
     tails

     The  baud	argument specifies the baud rate of the communication, eg. 9600,
     19200, 57600, 115200, etc.

     The parity argument can have one of the following values:

     * N for none

     * E for even

     * O for odd

     The data_bit argument specifies the number of bits  of  data,  the  allowed
     values are 5, 6, 7 and 8.

     The  stop_bit argument specifies the bits of stop, the allowed values are 1
     and 2.

     Once the modbus_t structure is initialized, you can connect to  the  serial
     bus with modbus_connect <modbus_connect.md>.

     In RTU, your program can act as server or client:

     * server  is  called  slave in Modbus terminology, your program will expose
       data to the network by processing and answering the requests  of  one  of
       several clients. It up to you to define the slave ID of your service with
       modbus_set_slave  <modbus_set_slave.md>,  this  ID  should be used by the
       client to communicate with your program.

     * client is called master in Modbus terminology, your program will send re-
       quests to servers to read or write data from them. Before issuing the re-
       quests, you should define the slave ID of the  remote  device  with  mod-
       bus_set_slave  <modbus_set_slave.md>.  The slave ID is not an argument of
       the read/write functions because it's very frequent to talk with only one
       server so you can set it once and for all. The slave ID it  not	used  in
       TCP communications so this way the API is common to both.

Return value
     The  function shall return a pointer to a modbus_t structure if successful.
     Otherwise it shall return NULL and set errno to one of the  values  defined
     below.

Errors
     * EINVAL, an invalid argument was given.

     * ENOMEM,	out  of  memory. Possibly, the application hits its memory limit
       and/or whole system is running out of memory.

Example
     In this example, the program will open a serial communication on  USB.  All
     subsequent  calls	such  as  read or write of registers will be sent on the
     wire and the request will be visible to all connected devices. According to
     the Modbus protocol, only the master associated to slave ID 10 will process
     and answer your requests.

     const int REMOTE_ID = 10;
     modbus_t *ctx;
     uint16_t tab_reg[10];

     ctx = modbus_new_rtu("/dev/ttyUSB0", 115200, 'N', 8, 1);
     if (ctx == NULL) {
	 fprintf(stderr, "Unable to create the libmodbus context\n");
	 return -1;
     }

     if (modbus_connect(ctx) == -1) {
	 fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
	 modbus_free(ctx);
	 return -1;
     }

     modbus_set_slave(ctx, REMOTE_ID);

     // Read 2 registers from address 0 of server ID 10.
     modbus_read_registers(ctx, 0, 2, tab_reg);

See also
     * modbus_new_tcp <modbus_new_tcp.md>

     * modbus_free <modbus_free.md>

								modbus_new_rtu()