modbus_report_slave_id()				modbus_report_slave_id()

Name
     modbus_report_slave_id - returns a description of the controller

Synopsis
     int modbus_report_slave_id(modbus_t *ctx, int max_dest, uint8_t *dest);

Description
     The  modbus_report_slave_id()  function  shall  send  a request to the con-
     troller to obtain a description of the controller.

     The response stored in dest contains:

     * the slave ID, this unique ID is in reality not unique at all so it's  not
       possible  to  depend  on it to know how the information are packed in the
       response.

     * the run indicator status (0x00 = OFF, 0xFF = ON)

     * additional data specific to each controller. For example,  libmodbus  re-
       turns the version of the library as a string.

     The function writes at most max_dest bytes from the response to dest so you
     must ensure that dest is large enough.

Return value
     The function shall return the number of read data if successful.

     If the output was truncated due to the max_dest limit then the return value
     is  the  number  of  bytes  which would have been written to dest if enough
     space had been available. Thus, a return value greater than max_dest  means
     that the response data was truncated.

     Otherwise it shall return -1 and set errno.

Example
     uint8_t tab_bytes[MODBUS_MAX_PDU_LENGTH];

     ...

     rc = modbus_report_slave_id(ctx, MODBUS_MAX_PDU_LENGTH, tab_bytes);
     if (rc > 1) {
	 printf("Run Status Indicator: %s\n", tab_bytes[1] ? "ON" : "OFF");
     }

							modbus_report_slave_id()

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=modbus_report_slave_id&sektion=3&manpath=FreeBSD+Ports+15.1.quarterly>