mspdebug(1)		     General Commands Manual		     mspdebug(1)

NAME
     MSPDebug - debugging tool for MSP430 MCUs

SYNOPSIS
     mspdebug [options] driver [command ...]

DESCRIPTION
     MSPDebug  is a command-line tool designed for debugging and programming the
     MSP430 family of MCUs. It supports the eZ430-F2013,  eZ430-RF2500,  Launch-
     pad,  Chronos, FET430UIF, GoodFET, Olimex MSP430-JTAG-TINY and MSP430-JTAG-
     ISO programming tools, as well as a simulation mode.

     When started with appropriate options, MSPDebug will attempt to connect  to
     the  debugging tool specified and identify the device under test. Once con-
     nected, the user is presented with a command prompt which can  be	used  to
     reflash the device memory, inspect memory and registers, set registers, and
     control the CPU (single step, run and run to breakpoint).

     It supports a variety of file formats, described in the section BINARY FOR-
     MATS below. It can also be used as a remote stub for gdb(1).

     On  startup,  MSPDebug  will  look for a file called .mspdebug first in the
     current directory, and then in the user's home directory.	If  either  file
     exists,  commands will be read and executed from this file before executing
     any other commands or starting the interactive reader.

     Alternatively, a configuration file can be explicitly specified with the -C
     option.

COMMAND-LINE OPTIONS
     Command-line options accepted by MSPDebug are described below. If	commands
     are  specified on the end of the command-line, then they are executed after
     connecting to the device, and the interactive prompt is not started. Please
     be aware that commands consisting of multiple words need to be enclosed  in
     quotation	marks,	otherwise  they are treated as single commands. Thus the
     common prog command would be used as "prog main.elf".  See the section  la-
     belled COMMANDS for more information.

     -q     Start in quiet mode. See the "quiet" option described below.

     -v voltage
	    Set  the  programming voltage. The voltage should be specified as an
	    integer in millivolts. It defaults to 3000 (3.0 V).

     -j     Use JTAG instead of Spy-Bi-Wire to communicate with the MSP430. This
	    option doesn't work with eZ430 or eZ430-RF2500 devices,  which  sup-
	    port Spy-Bi-Wire only.

     -d device
	    Specify  that the driver should connect via a tty device rather than
	    USB.  The supported connection methods vary depending on the driver.
	    See the section DRIVERS below for details.

     -U bus:device
	    Specify a particular USB device to connect to. Without this  option,
	    the first device of the appropriate type is opened.

     -s serial
	    Specify  a	particular  USB  device serial number to connect to. Use
	    this option to distinguish between	multiple  devices  of  the  same
	    type.

     -n     Do not process the startup file (~/.mspdebug).

     -C fileSpecify  an alternative configuration file (default is ~/.mspdebug).
	    If -n is specified as well, no file will be read.

     --long-password
	    When using the flash-bsl driver, send a 32-byte BSL password instead
	    of the standard 16-byte password.

     --help Display a brief help message and exit.

     --fet-list
	    Display a list of chips supported by the FET driver (the driver used
	    for UIF, RF2500 and Olimex devices).

     --fet-force-id string
	    When using a FET device, force the connected chip to  be  recognised
	    by	MSPDebug  as  one  of the given type during initialization. This
	    overrides the device ID returned by the FET. The given string should
	    be a chip name in long form, for example "MSP430F2274".

     --fet-skip-close
	    When using a FET device, skip the JTAG close procedure when  discon-
	    necting.   With some boards, this removes the need to replug the de-
	    bugger after use.

     --usb-list
	    List available USB devices and exit.

     --force-reset
	    When using a FET device, always send a reset during  initialization.
	    By default, an initialization without reset will be tried first.

     --allow-fw-update
	    When  using a V3 FET device via the TI library, allow the library to
	    perform a firmware update if the FET firmware is  incompatible  with
	    the library.

     --require-fw-update image.txt
	    When  using  a  V3	FET  device,  or certain Olimex devices, force a
	    firmware update using the given firmware image. The firmware  format
	    depends on the driver.

     --version
	    Show program version and copyright information.

     --embedded
	    Start  mspdebug as an embedded subprocess. See the documentation ac-
	    companying the source release for more information on embedded mode.

     --bsl-entry-sequence seq
	    Specify a BSL entry sequence. Each character specifies a modem  con-
	    trol line transition (R: RTS on, r: RTS off, D: DTR on, d: DTR off).
	    A  comma  indicates  a delay. The entry and exit sequences are sepa-
	    rated by a colon. The default value is dR,r,R,r,R,D:dR,DR,	for  the
	    flash-bsl driver.

     --bsl-entry-password hex-string
	    Specify a BSL unlock password as a hexadecimal byte string. This op-
	    tion  affects  both the flash and ROM BSL drivers. The password will
	    be padded with 0xff bytes, and the default password  is  a	sequence
	    consisting of only 0xff bytes.

DRIVERS
     For  drivers supporting both USB and tty access, USB is the default, unless
     specified otherwise (see -d above).

     On Linux, if USB access is used, the kernel driver  (if  any)  is	detached
     from the tty device. If further access to the tty device is needed, unload-
     ing and re-loading of the driver (e.g. cdc-acm.ko) is required.

     A driver name must be specified on the command line for MSPDebug to connect
     to. Valid driver names are listed here.

     rf2500 Connect  to  an  eZ430-RF2500, Launchpad or Chronos device. Only USB
	    connection is supported.

     olimex Connect to an Olimex MSP430-JTAG-TINY device. Both USB and	tty  ac-
	    cess are supported.

     olimex-v1
	    Connect  to an Olimex MSP430-JTAG-TINY (V1) device. Both USB and tty
	    access are supported. This driver must be used instead of olimex  if
	    connecting to a V1 device via a tty interface.

     olimex-iso
	    Connect to an Olimex MSP430-JTAG-ISO device. Both USB and tty access
	    are supported.

     olimex-iso-mk2
	    Connect  to  an  Olimex MSP430-JTAG-ISO-MK2 device. Both USB and tty
	    access are supported.

     sim    Do not connect to any hardware device, but instead start in  simula-
	    tion mode. A 64k buffer is allocated to simulate the device memory.

	    During  simulation, addresses below 0x0200 are assumed to be IO mem-
	    ory.  Programmed IO writes to and from IO memory are handled by  the
	    IO	simulator, which can be configured and controlled with the simio
	    command, described below.

	    This mode is intended for testing of changes to  MSPDebug,	and  for
	    aiding  the disassembly of MSP430 binaries (as all binary and symbol
	    table formats are still usable in this mode).

     uif    Connect to an eZ430-F2013 or a FET430UIF device. The device argument
	    should be the filename of the appropriate tty device. The TI  serial
	    converter  chips on these devices are supported by newer versions of
	    the Linux kernel, and should appear as /dev/ttyXX when attached.

	    USB connection is supported for this driver. The USB interface  chip
	    in	these devices is a TI3410, which requires a firmware download on
	    startup. MSPDebug will search for a file called  ti_3410.fw.ihex  in
	    the  configured library directory and the current directory. You can
	    specify  an  alternate  location  for  the	file  via   the   MSPDE-
	    BUG_TI3410_FW environment variable.

     uif-bslConnect  to the bootloader on a FET430UIF device. These devices con-
	    tain MSP430F1612 chips. By sending a special command  sequence,  you
	    can  obtain  access  to  the  bootloader  and  inspect memory on the
	    MSP430F1612 in the programming device itself.

	    Currently, only memory read/write and erase are supported. CPU  con-
	    trol via the bootloader is not possible.

     flash-bsl
	    Connect  to  the  built-in	bootloader  in MSP430 devices with flash
	    bootloader memory. Devices with ROM bootloaders require another dri-
	    ver. Currently, this driver must mass-erase the device in  order  to
	    gain access. Read, write, and erase operations are supported.

	    USB  connection  is not supported for this driver. Connection is via
	    serial port, and bootloader entry is accomplished via  the	RTS  and
	    DTR  lines.  Connect RTS to the device's TEST pin and DTR to the de-
	    vice's RST pin.  Use an appropriate serial level-shifter to make the
	    connection, if necessary.  If connecting to a device with non-multi-
	    plexed JTAG pins, connect RTS to the device's TCK  pin  via  an  in-
	    verter.

     gdbc   GDB client mode. Connect to a server which implements the GDB remote
	    protocol and provide an interface to it. To use this driver, specify
	    the remote address in hostname:port format using the -d option.

     tilib  Use  the  Texas Instruments MSP430.DLL to access the device. The li-
	    brary file (MSP430.DLL for Windows, libmsp430.so for Unix-like  sys-
	    tems)  must be present in the dynamic loader search path, unless the
	    MSPDEBUG_TILIB_PATH environment variable is present in which case it
	    will look there.

	    USB connection is not supported for this driver.  This  driver  sup-
	    ports  watchpoints.  Note  that the -d option for this driver passes
	    its argument straight through  to  the  library's  MSP430_Initialize
	    function.  Any special argument supported by that function is there-
	    fore accessible via the -d option.

	    Automatic device discovery works only on Linux and Windows. On other
	    systems, the appropriate ACM serial node must be  explicitly  speci-
	    fied.

     goodfetConnect  to  a  GoodFET device. JTAG mode must be used, and only tty
	    access is supported. This device  can  be  used  for  memory  access
	    (read,  erase  and program), but CPU control is limited. The CPU may
	    be halted, run and reset, but register access and breakpoints aren't
	    supported.

     pif    Connect to a parallel-port JTAG controller. JTAG mode must be  used,
	    and  only  tty  access  is supported. Currently, this driver is only
	    supported on Linux, FreeBSD and DragonFly BSD. A parallel  port  de-
	    vice  (ppdev  on  Linux,  ppi  on FreeBSD and DragonFly BSD) must be
	    specified via the -d option.

     gpio   Connect to system gpios. JTAG mode must be used, and only tty access
	    is supported. Currently, this driver is  only  supported  on  Linux,
	    FreeBSD  and  DragonFly  BSD. The gpios to used must defined using a
	    string like "tdi=7 tdo=8 tms=9 tck=4 rst=10 tst=11" via the  -d  op-
	    tion. (don't forget the quotes)

     load-bsl
	    Connect  to  a  USB  bootloader. The stub bootloader will be used to
	    load a fuller-featured bootloader into RAM for execution.

     ezfet  This driver is for Texas Instruments' eZ-FET  devices.  It	supports
	    USB and tty access. It does not support breakpoint control.

     rom-bslThis driver is for the old-style (ROM) bootstrap loader. It supports
	    tty access only. Entry is attempted via the RTS/DTR signals. The de-
	    fault  sequence is DR,r,R,r,d,R:DR,r, but you can override this with
	    the --bsl-entry-sequence option.

	    WARNING: this driver unlocks the BSL by  performing  a  mass  erase.
	    There  are	reports  of this operation causing an erase of info A in
	    some devices. Use at your own risk.

     bus-pirate
	    Raw JTAG using Bus Pirate devices.

COMMANDS
     MSPDebug can accept commands either through an interactive prompt, or  non-
     interactively  when  specified  on the command line. The supported commands
     are listed below.

     Commands take arguments separated by spaces. Any text  string  enclosed  in
     double-quotation  marks  is  considered to be a single argument, even if it
     contains space characters. Within a quoted string, the usual C-style  back-
     slash substitutions can be used.

     Commands can be specified by giving the first few characters of the command
     name,  provided that the prefix is unambiguous. Some commands support auto-
     matic repeat. For these commands, pressing enter at the reader prompt with-
     out typing anything will cause repeat execution.

     ! [command [args ...]]
	    Invoke an interactive operating system shell. If any  arguments  are
	    specified,	the first one is taken as a command to execute, with the
	    rest of the arguments as the arguments to the command.

	    This command is not yet available on non-POSIX systems.

     = expression
	    Evaluate an address expression and show both its value, and the  re-
	    sult  when	the  value is looked up in reverse in the current symbol
	    table. This result is of the form symbol+offset, where symbol is the
	    name of the nearest symbol not past the address in question.

	    See the section marked ADDRESS EXPRESSIONS for more  information  on
	    the syntax of expressions.

     alias  Show a list of defined command aliases.

     alias name
	    Remove a previously defined command alias.

     alias name command
	    Define  a  command	alias.	The text command will be substituted for
	    name when looking up commands. The given command text may contain  a
	    command plus arguments, if the entire text is wrapped in quotes when
	    defining  the  alias.  To avoid alias substitution when interpreting
	    commands, prefix the command with \ (a backslash character).

     blow_jtag_fuse
	    Blow the device's JTAG fuse.

	    WARNING: this is an irreversible operation!

     break  Show a list of active breakpoints. Breakpoints can be added and  re-
	    moved  with  the  setbreak and delbreak commands. Each breakpoint is
	    numbered with an integer index starting at 0.

     cgraph address length [address]
	    Construct the call graph of all functions contained or referenced in
	    the given range of memory. If a particular	function  is  specified,
	    then  details for that node of the graph are displayed. Otherwise, a
	    summary of all nodes is displayed.

	    Information from the symbol table is used for hinting at the  possi-
	    ble  locations of function starts. Any symbol which does not contain
	    a "." is considered a possible function start.

	    Callers and callee names are shown prefixed by a "*" where the tran-
	    sition is a tail-call type transition.

     delbreak [index]
	    Delete one or all breakpoints. If an index is  given,  the	selected
	    breakpoint is deleted. Otherwise, all breakpoints are cleared.

     dis address [length]
	    Dissassemble  a section of memory. Both arguments may be address ex-
	    pressions. If no length is	specified,  a  section	of  the  default
	    length (64 bytes) is disassembled and shown.

	    If	symbols  are  available, then all addresses used as operands are
	    translated into symbol+offset form.

	    This command supports repeat execution. If repeated, it continues to
	    disassemble another block of memory following that last printed.

     erase [all|segment|segrange] [address] [size] [segrange]
	    Erase the device under test. With no arguments, all code  memory  is
	    erased  (but  not  information  or	boot  memory). With the argument
	    "all", a mass erase is performed (the  results  may  depend  on  the
	    state of the LOCKA bit in the flash memory controller).

	    Specify  "segment" and a memory address to erase an individual flash
	    segment. Specify "segrange", an address, size and  segment	size  to
	    erase an arbitrary set of contiguous segments.

     exit   Exit from MSPDebug.

     fill address length b0 [b1 b2 ...]
	    Fill  the  memory region of size length starting at address with the
	    pattern of bytes given (specified in hexadecimal). The pattern  will
	    be	repeated  without padding as many times as necessary without ex-
	    ceeding the bounds of the specified region.

     gdb [port]
	    Start a GDB remote stub, optionally specifying a TCP port to  listen
	    on.   If no port is given, the default port is controlled by the op-
	    tion gdb_default_port.

	    MSPDebug will wait for a connection on this port, and then act as  a
	    GDB remote stub until GDB disconnects.

	    GDB's  "monitor"  command can be used to issue MSPDebug commands via
	    the GDB interface. Supplied commands are executed non-interactively,
	    and the output is sent back to be displayed in GDB.

     help [command]
	    Show a brief listing of available commands. If an argument is speci-
	    fied, show the syntax for the given command.  The  help  text  shown
	    when no argument is given is also shown when MSPDebug starts up.

     hexout address length filename
	    Read  the  specified  section of the device memory and save it to an
	    Intel HEX file. The address and length arguments may both be address
	    expressions.

	    If the specified file already exists, then it will	be  overwritten.
	    If you need to dump memory from several disjoint memory regions, you
	    can do this by saving each section to a separate file. The resulting
	    files  can	then be concatenated together to form a single valid HEX
	    file.

     isearch address length [options ...]
	    Search over the given range for an	instruction  which  matches  the
	    specified  search criteria. The search may be narrowed by specifying
	    one or more of the following terms:

	    opcode opcode
		   Match the specified	opcode.  Byte/word  specifiers	are  not
		   recognised, as they are specified with other options.

	    byte   Match only byte operations.

	    word   Match only word operations.

	    aword  Match only address-word (20-bit) operations.

	    jump   Match  only	jump instructions (conditional and unconditional
		   jumps, but not instructions such as BR which load the program
		   counter explicitly).

	    single Match only single-operand instructions.

	    double Match only double-operand instructions.

	    noarg  Match only instructions with no arguments.

	    src address
		   Match instructions with the specified  value  in  the  source
		   operand.  The  value  may  be given as an address expression.
		   Specifying this  option  implies  matching  of  only  double-
		   operand instructions.

	    dst address
		   Match  instructions	with the specified value in the destina-
		   tion operand. This option implies that  no-argument	instruc-
		   tions are not matched.

	    srcreg register
		   Match instructions using the specified register in the source
		   operand.  This option implies matching of only double-operand
		   instructions.

	    dstreg register
		   Match instructions using the specified register in the desti-
		   nation operand.  This option  implies  that	no-argument  in-
		   structions are not matched.

	    srcmode mode
		   Match  instructions	using  the  specified mode in the source
		   operand. See below for a list of modes recognised.  This  op-
		   tion implies matching of only double-operand instructions.

	    dstmode mode
		   Match  instructions	using the specified mode in the destina-
		   tion operand. See below for a list of modes. This option  im-
		   plies that no-argument instructions are not matched.

	    For single-operand instructions, the operand is considered to be the
	    destination operand.

	    The  seven	addressing  modes  used by the MSP430 are represented by
	    single characters, and are listed here:

	    R	   Register mode.

	    I	   Indexed mode.

	    S	   Symbolic mode.

	    &	   Absolute mode.

	    @	   Register-indirect mode.

	    +	   Register-indirect mode with auto-increment.

	    #	   Immediate mode.

     load filename
	    Program the device under test using the binary file  supplied.  This
	    command  is like prog, but it does not load symbols or erase the de-
	    vice before programming.

	    The CPU is reset and halted before and after programming.

     load_raw filename address
	    Write the data contained in a raw binary file to  the  given  memory
	    address.

	    The CPU is reset and halted before and after programming.

     md address [length]
	    Read  the  specified  section  of  device memory and display it as a
	    canonical-style hexdump. Both arguments may be address  expressions.
	    If	no  length  is	specified,  a  section of the default length (64
	    bytes) is shown.

	    The output is split into three columns. The first column  shows  the
	    starting address for the line. The second column lists the hexadeci-
	    mal values of the bytes. The final column shows the ASCII characters
	    corresponding to printable bytes, and . for non-printing characters.

	    This command supports repeat execution. If repeated, it continues to
	    print another block of memory following that last printed.

     mw address bytes ...
	    Write  a  sequence of bytes at the given memory address. The address
	    given may be an address expression. Bytes values are two-digit hexa-
	    decimal numbers separated by spaces.

     opt [name] [value]
	    Query, set or list option variables.  MSPDebug's  behaviour  can  be
	    configured	using  option  variables, described below in the section
	    OPTIONS.

	    Option variables may be of three types: boolean,  numeric  or  text.
	    Numeric values may be specified as address expressions.

	    With  no arguments, this command displays all available option vari-
	    ables.  With just an option name as its argument,  it  displays  the
	    current value of that option.

     power info
	    Show  basic  power	statistics  gathered over the last few sessions.
	    This includes total charge consumption, run time  and  average  cur-
	    rent.

     power clear
	    Clear all recorded power statistics.

     power all [granularity]
	    Show sample data gathered over all sessions. An optional granularity
	    can  be  specified,  in  microseconds. For each time slice, relative
	    session time, charge consumption, current consumption  and	approxi-
	    mate code location are shown.

     power session N [granularity]
	    Same  as  power all, except that data is shown only for the Nth ses-
	    sion.

     power export-csv N filename
	    Export raw sample data for the Nth session to the given file in  CSV
	    format.  For  each line, the columns are, in order: relative time in
	    microseconds, current consumption in microamps, memory address.

     power profile
	    If a symbol table is loaded,  compile  and	correlate  all	gathered
	    power  data  against  the symbol table. A single table is then shown
	    listing, per function, charge consumption, run time and average cur-
	    rent. The functions  are  listed  in  order  of  charge  consumption
	    (biggest consumers first).

     prog filename
	    Erase and reprogram the device under test using the binary file sup-
	    plied.  The  file format will be auto-detected and may be any of the
	    supported file formats.

	    In the case of a file containing symbols, symbols will be  automati-
	    cally loaded from the file into the symbol table (discarding any ex-
	    isting symbols), if they are present.

	    The CPU is reset and halted before and after programming.

     read filename
	    Read  commands  from  the  given file, line by line and process each
	    one.  Any lines whose first non-space character is # are ignored. If
	    an error occurs while processing a command, the rest of the file  is
	    not processed.

     regs   Show  the  current	value  of  all CPU registers in the device under
	    test.

     reset  Reset (and halt) the CPU of the device under test.

     run    Start running the CPU. The interactive  command  prompt  is  blocked
	    when  the  CPU is started and the prompt will not appear again until
	    the CPU halts. The CPU will halt if it encounters a  breakpoint,  or
	    if Ctrl-C is pressed by the user.

	    After  the	CPU halts, the current register values are shown as well
	    as a disassembly of the first few instructions at  the  address  se-
	    lected by the program counter.

     save_raw address length filename
	    Save a region of memory to a raw binary file. The address and length
	    arguments may both be address expressions.

	    If the specified file already exists, then it will be overwritten.

     set register value
	    Alter  the	value  of a register. Registers are specified as numbers
	    from 0 through 15. Any leading non-numeric	characters  are  ignored
	    (so  a  register may be specified as, for example, "R12"). The value
	    argument is an address expression.

     setbreak address [index]
	    Add a new breakpoint. The breakpoint location is an address  expres-
	    sion.  An  optional index may be specified, indicating that this new
	    breakpoint should overwrite an existing slot. If no index is  speci-
	    fied, then the breakpoint will be stored in the next unused slot.

     setwatch address [index]
	    Add  a new watchpoint. The watchpoint location is an address expres-
	    sion, and an optional index may be specified. Watchpoints  are  con-
	    sidered  to  be a type of breakpoint and can be inspected or removed
	    using the break and delbreak commands. Note  that  not  all  drivers
	    support watchpoints.

     setwatch_r address [index]
	    Add a watchpoint which is triggered only on read access.

     setwatch_w address [index]
	    Add a watchpoint which is triggered only on write access.

     simio add class name [args ...]
	    Add a new peripheral to the IO simulator. The class parameter may be
	    any of the peripheral types named in the output of the simio classes
	    command. The name parameter is a unique name assigned by the user to
	    this  peripheral  instance, and is used with other commands to refer
	    to this instance of the peripheral.

	    Some peripheral classes take arguments upon creation. These are doc-
	    umented in the output to the simio help command.

     simio classes
	    List the names of the different types of peripherals  which  may  be
	    added to the simulator. You can use the simio help command to obtain
	    more information about each peripheral type.

     simio config name param [args ...]
	    Configure or perform some action on a peripheral instance. The param
	    argument is specific to the peripheral type. A list of valid config-
	    uration commands can be obtained by using the simio help command.

     simio del name
	    Remove  a  previously  added  peripheral instance. The name argument
	    should be the name of the peripheral  that	was  assigned  with  the
	    simio add command.

     simio devices
	    List  all  peripheral instances currently attached to the simulator,
	    along with their types and interrupt status. You can obtain more de-
	    tailed information for each instance with the simio info command.

     simio help class
	    Obtain more information about a peripheral class. The  documentation
	    given  will  list constructor arguments and configuration parameters
	    for the device type.

     simio info name
	    Display detailed status information for a particular peripheral. The
	    type of information displayed is specific to each  type  of  periph-
	    eral.

     step [count]
	    Step  the  CPU through one or more instructions. After stepping, the
	    new register values are displayed, as well as a disassembly  of  the
	    instructions at the address selected by the program counter.

	    An optional count can be specified to step multiple times. If no ar-
	    gument  is	given,	the CPU steps once. This command supports repeat
	    execution.

     sym clear
	    Clear the symbol table, deleting all symbols.

     sym set name value
	    Set or alter the value of a symbol. The value given may  be  an  ad-
	    dress expression.

     sym del name
	    Delete the given symbol from the symbol table.

     sym import filename
	    Load  symbols from the specified file and add them to the symbol ta-
	    ble.  The file format will be auto-detected and may be either  ELF32
	    or a BSD-style symbol listing (like the output from nm(1)).

	    Symbols  can be combined from many sources, as the syms command adds
	    to the existing symbol table without discarding existing symbols.

     sym import+ filename
	    This command is similar to sym import, except that the symbol  table
	    is	not  cleared first. By using this command, symbols from multiple
	    sources can be combined.

     sym export filename
	    Save all symbols currently defined to the given  file.  The  symbols
	    are  saved	as  a BSD-style symbol table. Note that symbol types are
	    not stored by MSPDebug, and all symbols are saved as type t.

     sym find [regex]
	    Search for symbols. If a regular expression is given, then all  sym-
	    bols matching the expression are printed. If no expression is speci-
	    fied, then the entire symbol table is listed.

     sym rename regex string
	    Rename symbols by searching for those matching the given regular ex-
	    pression  and substituting the given string for the matched portion.
	    The symbols renamed are displayed, as well as a total count  of  all
	    symbols renamed.

     verify filename
	    Compare the contents of the given binary file to the chip memory. If
	    any  differences  are found, a message is printed for the first mis-
	    matched byte.

     verify_raw filename address
	    Compare the contents of a raw binary file to the  device  memory  at
	    the  given	address.  If  any  differences	are  found, a message is
	    printed for the first mismatched byte.

BINARY FORMATS
     The following binary/symbol formats are supported by MSPDebug:

	    ELF32
	    COFF
	    Intel HEX (program only)
	    BSD symbol table (symbols only)
	    TI Text (program only)
	    SREC (program only)

IO SIMULATOR
     The IO simulator subsystem consists of a database of device classes, and  a
     list  of  instances of those classes. Each device class has a different set
     of constructor arguments, configuration parameters  and  information  which
     may be displayed. This section describes the operation of the available de-
     vice classes in detail.

     In the list below, each device class is listed, followed by its constructor
     arguments.

     gpio   Digital  IO port simulator. This device simulates any of the digital
	    ports with or without interrupt capability.  It  has  the  following
	    configuration parameters:

	    base address
		   Set the base address for this port. Note that for ports with-
		   out interrupt capability, the resistor enable port has a spe-
		   cial address which is computable from the base address.

	    irq vector
		   Enable interrupt functionality for this port by specifying an
		   interrupt vector number.

	    noirq  Disable interrupt functionality for this port.

	    verbosePrint  a  state  change  message  every  time the port output
		   changes.

	    quiet  Don't print anything when the port  state  changes  (the  de-
		   fault).

	    set pin value
		   Set	the  input pin state for the given pin on this port. The
		   pin parameter should be an index between 0 and 7.  The  value
		   should  be  either  zero (for a low state) or non-zero (for a
		   high state).

     hwmult This peripheral simulates the hardware multiplier. It  has	no  con-
	    structor  or  configuration parameters, and does not provide any ex-
	    tended information.

     timer [size]
	    This peripheral simulators Timer_A modules, and can be used to simu-
	    late Timer_B modules, provided that the extended features aren't re-
	    quired.

	    The constructor takes a size argument specifying the number of  cap-
	    ture/compare  registers  in  this peripheral instance. The number of
	    such registers may not be less than 2, or greater than 7.

	    The IO addresses and IRQs used are configurable. The default IO  ad-
	    dresses  used are those specified for Timer_A in the MSP430 hardware
	    documentation.

	    base address
		   Alter the base IO address. By default,  this  is  0x0160.  By
		   setting this to 0x0180, a Timer_B module may be simulated.

	    irq0 number
		   Set	the  TACCR0 interrupt vector number. By default, this is
		   interrupt vector 9.	This  interrupt  is  self-clearing,  and
		   higher priority than the TACCR1/TAIFG vector.

	    irq1 number
		   Set	the  TACCR1/TAIFG  interrupt vector. By default, this is
		   interrupt vector 8.

	    iv address
		   Alter the address of the interrupt vector  register.  By  de-
		   fault,  this is 0x012E.  By setting this to 0x011E, a Timer_B
		   module may be simulated.

	    set channel value
		   When Timer_A is used in capture mode, the  CCI  bit	in  each
		   capture  register reflects the state of the corresponding in-
		   put pin, and can't be altered in software. This configuration
		   command can be used to simulate changes in input  pin  state,
		   and	will trigger the corresponding interrupts if the periph-
		   eral is so configured.

     tracer [history-size]
	    The tracer peripheral is a debugging device. It can be used  to  in-
	    vestigate and record the IO activity of a running program, to bench-
	    mark execution time, and to simulate interrupts.

	    The  information  displayed  by  the tracer gives a running count of
	    clock cycles from each of the  system  clocks,  and  an  instruction
	    count. A list of the N most recent IO events is also displayed (this
	    is	configurable  via the history-size argument of the constructor).
	    Each IO event is timestamped by the number of MCLK cycles that  have
	    elapsed since the last reset of the device's counter.

	    The  IO  events  that  it records consist of programmed IO reads and
	    writes, interrupt acceptance, and system resets. As well as  keeping
	    the  IO events in a rotating buffer, the tracer can be configured to
	    display the events as they occur.

	    Note that since clock cycles don't advance while the CPU isn't  run-
	    ning,  this  peripheral can be used to calculate execution times for
	    blocks of code. This can be achieved by setting a breakpoint at  the
	    end  of  the code block, setting the program counter to the start of
	    the code block, clearing the tracer and running the code. After  the
	    breakpoint	is reached, the information displayed by the tracer will
	    contain a count of MCLK cycles elapsed during the last run.

	    The configuration parameters for this device class are:

	    verboseStart displaying IO events as they occur, as well as  record-
		   ing them in the rotating buffer.

	    quiet  Stop displaying IO events as they occur, and just record them
		   in the buffer.

	    trigger irq
		   Signal an interrupt request to the CPU. This request will re-
		   main raised until accepted by the CPU or cleared by the user.

	    untrigger
		   Clear a signalled interrupt request.

	    clear  Reset  the clock cycle and instruction counts to 0, and clear
		   the IO event history.

     wdt    This peripheral simulates the Watchdog Timer+, which can be used  in
	    software  either  as  a  watchdog or as an interval timer. It has no
	    constructor arguments.

	    The simulated state of the NMI/RST# pin can be controlled through  a
	    configuration  parameter.  Note  that  if this pin state is held low
	    with the pin mode selected as a reset (the default),  the  CPU  will
	    not run.

	    The  extended  information	for  this  peripheral shows all register
	    states, including the hidden counter register. Configuration parame-
	    ters are:

	    nmi state
		   Set the NMI/RST# pin state. The argument should  be	zero  to
		   indicate a low state or non-zero for a high state.

	    irq irqSelect  the interrupt vector for interval timer mode. The de-
		   fault is to use interrupt vector 10.

ADDRESS EXPRESSIONS
     Any command which accepts a memory address, length or register value as  an
     argument may be given an address expression. An address expression consists
     of an algebraic combination of values.

     An address value can be one of the following:
	    A symbol name
	    A CPU register name preceded with "@"
	    A hex value preceded with the specifier "0x"
	    A decimal value preceded with the specifier "0d"
	    A  number  in the default input radix (without a specifier). See the
	    option iradix for more information.

     The operators recognised are the usual algebraic operators: +, -, *, /,  %,
     (	and ). Operator precedence is the same as in C-like languages, and the -
     operator may be used as a unary negation operator.

     The following are all valid examples of address expressions:

     2+2
     table_start + (elem_size + elem_pad)*4
     main+0x3f
     __bss_end-__bss_start
     @sp

OPTIONS
     MSPDebug's behaviour can be configured via the following variables:

     color (boolean)
	    If true, MSPDebug will colorize debugging output.

     fet_block_size (numeric)
	    Change the size of the buffer used to transfer memory  to  and  from
	    the  FET.  Increasing  the value from the default of 64 will improve
	    transfer speed, but may cause problems with some chips.

     enable_bsl_access (boolean)
	    If set, some drivers will allow erase/program access  to  flash  BSL
	    memory. If in doubt, do not enable this.

     enable_locked_flash_access (boolean)
	    If	set,  some drivers will allow erase/program access to the info A
	    segment. If in doubt, do not enable this. Currently, the  tilib  and
	    uif drivers are affected by this option.

     enable_fuse_blow
	    If set, some drivers will allow the JTAG security fuse to be blown.

	    WARNING: this is an irreversible operation!

	    If in doubt, do not enable this option.

     gdb_default_port (numeric)
	    This  option controls the default TCP port for the GDB server, if no
	    argument is given to the "gdb" command.

     gdb_loop (boolean)
	    Automatically restart the GDB server after	disconnection.	If  this
	    option  is set, then the GDB server keeps running until an error oc-
	    curs, or the user interrupts with Ctrl+C.

     gdbc_xfer_size (numeric)
	    Maximum size of memory transfers for the GDB client. Increasing this
	    value will result in faster transfers, but may cause  problems  with
	    some servers.

     iradix (numeric)
	    Default input radix for address expressions. For address values with
	    no	radix  specifier,  this value gives the input radix, which is 10
	    (decimal) by default.

     quiet (boolean)
	    If set, MSPDebug will suppress most  of  its  debug-related  output.
	    This option defaults to false, but can be set true on start-up using
	    the -q command-line option.

ENVIRONMENT
     MSPDEBUG_TI3410_FW
	    Specifies  the  location  of  TI3410 firmware, for raw USB access to
	    FET430UIF or eZ430 devices. This variable should contain the path to
	    an Intel HEX file containing suitable firmware for the TI3410.

     MSPDEBUG_TILIB_PATH
	    Specifies the directory to find the Texas Instruments MSP430.DLL li-
	    brary.

FILES
     ~/.mspdebug
	    File containing commands to be executed on startup.

     ti_3410.fw.ihex
	    Firmware image for the TI3410 USB interface chip. This file is  only
	    required for raw USB access to FET430UIF or eZ430 devices.

SEE ALSO
     nm(1), gdb(1), objcopy(1)

BUGS
     If  you  find  any  bugs,	you  should  report  them  to  the author at dl-
     beer@gmail.com. It would help if you  could  include  a  transcript  of  an
     MSPDebug session illustrating the program, as well as any relevant binaries
     or other files.

COPYRIGHT
     Copyright (C) 2009-2013 Daniel Beer <dlbeer@gmail.com>

     MSPDebug  is  free software, distributed under the terms of the GNU General
     Public license (version 2 or later). See the file COPYING included with the
     source code for more details.

Version 0.25			   24 Jul 2017			     mspdebug(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=mspdebug&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help