Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
NVME-COMPARE(1) 		   NVMe Manual			 NVME-COMPARE(1)

NAME
     nvme-compare - Send an NVMe Compare command, provide results

SYNOPSIS
     nvme-compare <device> [--start-block=<slba> | -s <slba>]
			     [--block-count=<nlb> | -c <nlb>]
			     [--data-size=<size> | -z <size>]
			     [--metadata-size=<metasize> | -y <metasize>]
			     [--ref-tag=<reftag> | -r <reftag>]
			     [--data=<data-file> | -d <data-file>]
			     [--metadata=<meta> | -M <meta>]
			     [--prinfo=<prinfo> | -p <prinfo>]
			     [--app-tag-mask=<appmask> | -m <appmask>]
			     [--app-tag=<apptag> | -a <apptag>]
			     [--limited-retry | -l]
			     [--force-unit-access | -f]
			     [--dir-type=<type> | -T <type>]
			     [--dir-spec=<spec> | -S <spec>]
			     [--dsm=<dsm> | -D <dsm>]
			     [--show-command | -V]
			     [--dry-run | -w]
			     [--latency | -t]
			     [--storage-tag<storage-tag> | -g <storage-tag>]
			     [--storage-tag-check | -C]
			     [--force]
			     [--output-format=<fmt> | -o <fmt>] [--verbose | -v]
			     [--timeout=<timeout>]

DESCRIPTION
     The  Compare command reads the logical blocks specified by the command from
     the medium and compares the data read to a comparison  data  buffer  trans-
     ferred as part of the command. If the data read from the controller and the
     comparison data buffer are equivalent with no miscompares, then the command
     completes	successfully.  If there is any miscompare, the command completes
     with an error of Compare Failure. If metadata is provided, then a	compari-
     son is also performed for the metadata.

OPTIONS
     -s <slba>, --start-block=<slba>
	 64-bit address of the first block to access.

     -c <nlb>, --block-count=<nlb>
	 Number of blocks to be accessed (zero-based).

     -z <size>, --data-size=<size>
	 Size of data to be compared in bytes.

     -y <metasize>, --metadata-size=<metasize>
	 Size of metadata to be transferred in bytes.

     -r <reftag>, --ref-tag=<reftag>
	 Reference Tag for Protection Information

     -d <data-file>, --data=<data-file>
	 Data file.

     -M <meta>, --metadata=<meta>
	 Metadata file.

     -p <prinfo>, --prinfo=<prinfo>
	 Protection Information and check field.
	 +-----+-----------------------------+
	 | Bit | Description		     |
	 +-----+-----------------------------+
	 | 3   | PRACT:  Protection Informa- |
	 |     | tion Action. When set to 1, |
	 |     | PI is stripped/inserted  on |
	 |     | read/write  when  the block |
	 |     | format's metadata  size  is |
	 |     | 8.  When set to 0, metadata |
	 |     | is passes.		     |
	 +-----+-----------------------------+
	 | 2:0 | PRCHK: Protection  Informa- |
	 |     | tion Check:		     |
	 +-----+-----------------------------+
	 | 2   | Set  to  1 enables checking |
	 |     | the guard tag		     |
	 +-----+-----------------------------+
	 | 1   | Set to 1  enables  checking |
	 |     | the application tag	     |
	 +-----+-----------------------------+
	 | 0   | Set  to  1 enables checking |
	 |     | the reference tag	     |
	 +-----+-----------------------------+

     -m <appmask>, --app-tag-mask=<appmask>
	 App Tag Mask for Protection Information

     -a <apptag>, --app-tag=<apptag>
	 App Tag for Protection Information

     -l, --limited-retry
	 Number of limited attempts to media.

     -f, --force-unit-access
	 FUA option to guarantee that data is stored to media.

     -T <type>, --dir-type=<type>
	 Optional directive type. The nvme-cli only enforces the value be in the
	 defined range for the directive type,	though	the  NVMe  specification
	 (1.3a) defines only one directive, 01h, for write stream identifiers.

     -S <spec>, --dir-spec=<spec>
	 Optional  field  for directive specifics. When used with write streams,
	 this value is defined to be the write stream identifier.  The	nvme-cli
	 will not validate the stream requested is within the controller's capa-
	 bilities.

     -D <dsm>, --dsm=<dsm>
	 The optional data set management attributes for this command. The argu-
	 ment  for  this  is  the least significant 8 bits of the DSM field in a
	 write command; the most significant 16 bits of the field come from  the
	 directive  specific  field, if used. This may be used to set attributes
	 for the LBAs being written, like access frequency, type, latency, among
	 other things, as well as yet to be defined types.  Please  consult  the
	 NVMe specification for detailed breakdown of how to use this field.

     -V, --show-cmd
	 Print out the command to be sent.

     -w, --dry-run
	 Do  not  actually  send  the  command. If want to use --dry-run option,
	 --show-cmd option must be set. Otherwise --dry-run option will  be  ig-
	 nored.

     -t, --latency
	 Print out the latency the IOCTL took (in us).

     -g <storage-tag>, --storage-tag=<storage-tag>
	 Variable Sized Expected Logical Block Storage Tag(ELBST).

     -C, --storage-tag-check
	 This flag enables Storage Tag field checking as part of end-to-end data
	 protection processing.

     --force
	 Ignore  namespace  is	currently  busy and performed the operation even
	 though.

     -o <fmt>, --output-format=<fmt>
	 Set the reporting format to normal, json or  binary.  Only  one  output
	 format can be used at a time.

     -v, --verbose
	 Increase the information detail in the output.

     --timeout=<timeout>
	 Override default timeout value. In milliseconds.

EXAMPLES
     No examples yet.

NVME
     Part of the nvme-user suite

NVMe				   10/31/2024			 NVME-COMPARE(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=nvme-compare&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help