Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
NVME-DIR-RECEIVE(1)		   NVMe Manual		     NVME-DIR-RECEIVE(1)

NAME
     nvme-dir-receive - Send a directive receive command, returns applicable re-
     sults

SYNOPSIS
     nvme dir-receive <device> [--namespace-id=<nsid> | -n <nsid>]
			     [--data-len=<data-len> | -l <data-len>]
			     [--dir-type=<dtype> | -D <dtype>]
			     [--dir-spec=<dspec> | -S <dspec>]
			     [--dir-oper=<doper> | -O <doper>]
			     [--req-resource=<nsr> | -r <nsr>]
			     [--human-readable | -H] [--raw-binary | -b]
			     [--output-format=<fmt> | -o <fmt>] [--verbose | -v]
			     [--timeout=<timeout> | -t <timeout>]

DESCRIPTION
     Submits  an NVMe Directive Receive admin command and returns the applicable
     results. This may be the combination of directive type, and  operation,  as
     well as number of requested resource if specific operation needs it.

     The  <device>  parameter  is mandatory and may be either the NVMe character
     device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

     On success, the returned directive's parameter structure (if applicable) is
     returned in one of several ways depending on the option flags;  the  struc-
     ture  may parsed by the program and printed in a readable format if it is a
     known structure, displayed in hex, or the raw buffer may be printed to std-
     out for another program to parse.

OPTIONS
     -n <nsid>, --namespace-id=<nsid>
	 Retrieve the feature for the given nsid. This is optional and most fea-
	 tures do not use this value.

     -D <dtype>, --dir-type=<dtype>
	 Directive type

     -S <dspec>, --dir-spec=<dspec>
	 Directive specific

     -O <doper>, --dir-oper=<doper>
	 Directive operation

     -r <nsr>, --req-resource=<nsr>
	 Directive requested resource count
	 +--------+------------------------+
	 | Select | Description 	   |
	 +--------+------------------------+
	 | 0	  | Current		   |
	 +--------+------------------------+
	 | 1	  | Default		   |
	 +--------+------------------------+
	 | 2	  | Saved		   |
	 +--------+------------------------+
	 | 3	  | Supported capabilities |
	 +--------+------------------------+
	 | 4-7	  | Reserved		   |
	 +--------+------------------------+

     -l <data-len>, --data-len=<data-len>
	 The data length for the buffer returned for this  feature.  Most  known
	 features do not use this value. The exception is LBA Range Type

     -b, --raw-binary
	 Print	the raw receive buffer to stdout if the command returns a struc-
	 ture.

     -H, --human-readable
	 Print the decoded receive buffer to stdout if	the  command  returns  a
	 structure.

     -o <fmt>, --output-format=<fmt>
	 Set  the  reporting  format  to normal, json or binary. Only one output
	 format can be used at a time.

     -v, --verbose
	 Increase the information detail in the output.

     -t <timeout>, --timeout=<timeout>
	 Override default timeout value. In milliseconds.

EXAMPLES
     *	 Identify directive type supported :

	     # nvme dir-receive /dev/nvme0 --dir-type 0 --dir-oper 1 --human-readable

     *	 Get stream directive parameters :

	     # nvme dir-receive /dev/nvme0 --dir-type 1 --dir-oper 1 --human-readable

     *	 Allocate 3 streams for namespace 1

	     # nvme dir-receive /dev/nvme0n1 --dir-type 1 --dir-oper 3 --req-resource 3 --human-readable

     *	 Get streams directive status :

	     # nvme dir-receive /dev/nvme0 --dir-type 1 --dir-oper 2 --human-readable

	 It is probably a bad idea to not redirect stdout when using this mode.

NVME
     Part of the nvme-user suite

NVMe				   10/31/2024		     NVME-DIR-RECEIVE(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=nvme-dir-receive&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help