Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
OCF_HEARTBEAT_NVMET()					   OCF_HEARTBEAT_NVMET()

NAME
     ocf_heartbeat_nvmet-port - NVMe-oF target export agent

SYNOPSIS
     nvmet-port [start | stop | status | monitor | meta-data | validate-all]

DESCRIPTION
     Manages NVMe-oF ports. An NVMe-oF port is part of an NVMe-oF target. A port
     must  be  created	after  the subsystem. It exposes one or multiple subsys-
     tem(s) including the enclosed namespace(s) to the network.

SUPPORTED PARAMETERS
     port_id
	 The NVMe port number is a 16 bit number.

	 (unique, optional, integer, default 0)

     type
	 The NVMe transport type. Should  be  one  of  'tcp',  'rdma',	'fc'  or
	 'loop'.

	 (optional, string, default "tcp")

     addr_fam
	 The address family of the address. Should be 'ipv4', 'ipv6' or 'fc'.

	 (optional, string, default "ipv4")

     svcid
	 The  transport  service  identifier. The TCP/IP port number this target
	 binds to, or its RDMA protocol equivalent.

	 (optional, integer, default 4420)

     addr
	 The transport address. The TCP/IP address this targets binds to, or its
	 RDMA protocol equivalent.

	 (required, string, no default)

     nqns
	 A space-separated list of NQNs that should  be  exported  through  this
	 NVMe-oF-Target port. This list needs to have at least one entry.

	 (required, string, no default)

SUPPORTED ACTIONS
     This resource agent supports the following actions (operations):

     start
	 Starts the resource. Suggested minimum timeout: 10s.

     stop
	 Stops the resource. Suggested minimum timeout: 10s.

     status
	 Performs  a status check. Suggested minimum timeout: 10s. Suggested in-
	 terval: 10s.

     monitor
	 Performs a detailed status check. Suggested minimum timeout: 10s.  Sug-
	 gested interval: 10s.

     meta-data
	 Retrieves  resource agent metadata (internal use only). Suggested mini-
	 mum timeout: 5s.

     validate-all
	 Performs a validation of the resource configuration. Suggested  minimum
	 timeout: 10s.

EXAMPLE CRM SHELL
     The  following  is an example configuration for a nvmet-port resource using
     the crm(8) shell:

	 primitive p_nvmet-port ocf:heartbeat:nvmet-port \
	   params \
	     addr=string \
	     nqns=string \
	   op monitor timeout="10s" interval="10s" depth="0"

EXAMPLE PCS
     The following is an example configuration for a nvmet-port  resource  using
     pcs(8)

	 pcs resource create p_nvmet-port ocf:heartbeat:nvmet-port \
	   addr=string \
	   nqns=string \
	   op monitor timeout="10s" interval="10s" OCF_CHECK_LEVEL="0"

SEE ALSO
     http://clusterlabs.org/

AUTHOR
     ClusterLabs  contributors	(see  the  resource agent source for information
     about individual authors)