Skip site navigation (1)Skip section navigation (2)

  
 
  

home | help
p2hex(1)		     General Commands Manual			p2hex(1)

NAME
     p2hex - convert code files into hex files

SYNTAX
     p2hex [ option(s) ] <name(s)> [ further options/names ]

DESCRIPTION
     P2HEX is a tool to convert the contents of one or several code files gener-
     ated  by  AS into HEX files.  A HEX file is a common method of representing
     binary data in a way that is human-readable  and  transferrable  over  non-
     transparent  data	lines.	 Generally  spoken, each byte of code or data is
     represented by two characters that show the byte in its  hexadecimal  nota-
     tion.   A	HEX file also contains additional information like addresses and
     checksums that ease processing of the data.   Unfortunately,  there  is  no
     generally accepted standard format for HEX files.	Instead, every processor
     manufacturer  developed his own format and some of them have become "indus-
     try standards".  P2HEX supports all formats that seem to have gained accep-
     tance, with some variations that are commonplace.

     Arguments to P2HEX may be either command line parameters or file name spec-
     ifications.  Any argument that starts with the charactes +, - or /  is  re-
     garded  as  a  comand  line parameter (which may take an additional command
     line argument); any other argument is regarded as a file name.   Generally,
     P2HEX needs at least two file names: An input code file and the name of the
     HEX  output file.	If multiple file names are given, P2HEX will always take
     the last name as the output file's name.  If an input file  name  does  not
     have  an  extension, the extension '.p' is added automatically.  Similarly,
     the extension '.hex' is added automatically to the target file's  name.   A
     special  case occurs when only one file name is given: P2HEX will then take
     its name as the source (possibly extended with '.p'), and the same name  as
     target (with '.hex' as additional or replaced extension).

     By  default, P2HEX will choose a HEX format that is the most common for the
     processor family a source file contains code for; this however  means  that
     if the source file(s) contain(s) code for different processor families, the
     HEX  file	might  become an undesirable mixture of formats; use the -F com-
     mand-line parameter to force a certain format then.

COMMAND-LINE PARAMETERS
     If a command-line parameter starts with a slash(/)  or  minus  sign(-),  it
     turns an option on; if a command-line parameter starts with a plus sign(+),
     it turns a specific option off.  Numeric arguments to parameters can be ei-
     ther written in decimal or hexadecimal notation.  For hexadecimal notation,
     prefix  the  number  with a dollar($) sign.  In the following list, all op-
     tions will be shown in the form that is needed to change the default behav-
     iour, which might be a plus or minus sign, depening on wether the option is
     on or off by default.

     p2hex accepts the following command-line parameters:

     -a

	    Tell P2HEX to use relative addressing in the output  HEX  file.   By
	    default,  addresses  the  HEX file will be exactly the same absolute
	    addresses as they were in the code file.  This may	create	problems
	    with  some	EPROM-burners  if your code does not start at address 0.
	    In relative mode, the address filter's start  address  (see  the  -r
	    command line switch) is subtracted from all addresses specifications
	    in	the  HEX file (with the exception of the entry address).  There-
	    fore, addresses in the HEX file again start at 0.

     -d < <start address>-<stop address> >
	    Tell P2HEX that items in the address range	given  by  the	argument
	    should be regarded as data rather than code.  This option only has a
	    meaning  for  the  TI-DSK format that can differenciate between code
	    and data.  This option is principally obsolete since P2HEX	can  now
	    directly  process data from the DATA segment.  It should not be used
	    in new projects, since it may be removed in the near future.

     -e <address>

	    Set an entry address or modify an existing one.  Some HEX file  for-
	    mats  can  carry  a special record for an entry address that tells a
	    program loader where to jump after a program has been loaded.   Nor-
	    mally,  this  address is generated by AS if the program's END state-
	    ment has a label as argument, but this options allows to change  the
	    entry point or add one if it was forgotten in the program itself.

     -F <Default|Moto|Intel|Intel16|Intel32|MOS|Tek|DSK|C>

	    Force  a  certain format for the output HEX file.  By default, P2HEX
	    will choose one depending on the target processor.	Using Default as
	    argument will also set this behaviour, which might be useful to  re-
	    vert  to  P2HEX's  default behaviour if the default has been changed
	    (see the discussion of the P2HEXCMD variable  below  for  presetting
	    parameters).

	    Moto stands for the Motorola S-Record format, which allows addresses
	    from 16 to 32 bits in length and entry addresses.  It bears its name
	    due to the fact that every record starts with the letter S.

	    Intel  is the "standard" Intellec-MCS8-Format for a variety of Intel
	    8-Bit-CPUs that almost became a standard, but was originally limited
	    to 16-bit addresses.  In later editions, the  addressing  capability
	    was extended to 20 ( Intel16 ) and 32 bits ( Intel32 ).

	    MOS  is a simple format introduced by the manufacturer MOS for their
	    line of 65xx CPUs.	It is limited to 16-bit addresses, just like the
	    Tek format that was defined by Tektronix.

	    DSK is the format Texas Instruments uses for their	line  of  16-bit
	    fixed-point signal processors.  In contrast to all other formats, it
	    is word-oriented and can distinguish between data and code segments.
	    Atmel  is  the  simple  Hex format defined by Atmel for the AVR RISC
	    family.

     -f <number>[,<further numbers>]

	    Add <number> to the list of record header IDs that	allow  a  record
	    from  a  source  file  to  be written to the target file.  A certain
	    header ID marks code for a certain target  processor  family;  thus,
	    this  filter allows to distill code for a certain processor out of a
	    source file that contains code  for  different  processor  families.
	    Negation  of  this parameter removes certain header IDs from P2HEX's
	    list.  See the user manual of AS for a list of all	possible  header
	    ID	values.   If  P2HEX's  list of header IDs is empty, no filtering
	    will take place, i.e. all records from a source file  will	make  it
	    into the target file.

     -i <0|1|2>

	    Change the terminating line for an Intel-HEX file.	Normally, an In-
	    tel-HEX file is terminated with the line :00000001FF , but there are
	    sources that also mention :00000001 or :0000000000 as the last line.
	    The numeric argument of this parameter selects one of these opportu-
	    nities,  with  the first one being the default.  This parameter only
	    has an effect if the target file's format is one  of  the  Intel-HEX
	    variants.

     -l <length>

	    Set  the maximum number of bytes per record, and therefore the maxi-
	    mum length of a line in the target file.  Possible	values	are  be-
	    tween 2 and 254 bytes, with 16 being the default.

     -m <0..3>

	    Set  one of the four Intel-Hex variants defined by Microchip for the
	    PIC family of microcontrollers.  The Default is the INHX8(0) format,
	    which contains all words in  a  Lobyte-Hibyte-ordering.   INHX16M(1)
	    does  just	the opposite, whereas INHX8L(2) and INHX8H(3) only store
	    the lower resp. higher bytes of each word.	This parameter only  has
	    an	effect if the target file's format is one of the Intel-HEX vari-
	    ants.

     -r < <start>-<stop> >

	    Set a certain address range to be filtered out of the input file(s).
	    Code that lies outside this range does  not  appear  in  the  output
	    file.   The  default  for  the  address filter is the 0-$7fff, which
	    might create confusion in some cases.  As a special option,  <start>
	    and  <stop> may consist of just a single dollar sign (escape this in
	    UNIX shells!) or 0x to signify the lowest resp. highest address that
	    occurs in the input file(s).  Using this option will implicitly  en-
	    able a second pass over all input files to find the minimum and max-
	    imum  values  before  conversion starts, reducing the speed of P2HEX
	    slightly.

     -s

	    In Motorola S-Record format, force	P2HEX  to  write  a  termination
	    record  after  each group of data records, which may be necessary in
	    some cases (but creates problems most of the time...)

     +5

	    Disable output of Motorola S5-records, which contain the  number  of
	    data  records that were sent and therefore allow an additional level
	    of checking.  However, they are not understood by all  programs  and
	    therefore might be a source of trouble.

     -M <1|2|3>

	    Force  P2HEX  to  use a minimum length for the address fields of Mo-
	    torola S-records.  For example, a value of 2 will  effectively  dis-
	    able  S1  records,	and a value of 3 will force usage of S3 records.
	    The default is 1, which enables full  automatic  setting  of  the  S
	    record length.

     -avrlen <2|3>

	    Set the address field length of Atmel AVR Hex files to either two or
	    three bytes (the latter is the default).

     -k

	    Instruct P2HEX to erase the program source files after conversion.

     -avrlen <2|3>

	    Set  the width of the address field used for the Atmel hex file for-
	    mat.  By default, 3-byte addresses will be used.

PRESETTING PARAMETERS
     Parameters need not neccessarily be given in the command line itself.   Be-
     fore  processing  of command line parameters starts, P2HEX will look if the
     P2HEXCMD environment variable is defined.	If it exists, its contents  will
     be  treated as additional command line paramters whose syntax is absolutely
     equal to normal command line parameters.  As exception is made if the vari-
     able's contents start with a '@' sign; in such a case, the string after the
     '@' sign is treated as the name of a file that contains the options.   Such
     a	file (also called a 'key file') has the advantage that it allows the op-
     tions to be written in different lines, and it does not have a size  limit.
     Some  operating  systems  (like  MS-DOS)  do have a length limit on command
     lines and environment variable contents, so the key file may be  your  only
     option if you have a lot of lengthy parameters for P2HEX.

RETURN CODES
     p2hex may return with the following codes:

     0	    no errors.

     1	    incorrect command line parameters.

     2	    I/O-error.

     3	    An input file had an incorrect format.

EXAMPLES
     To convert a file file1.p fully into its HEX representation on a Unix plat-
     form, use

     p2hex -r \$-\$ file1

     If  you  additionally  want to force usage of the Motorola S-Record format,
     use

     p2hex -r \$-\$ -F Moto file1

NATIONAL LANGUAGE SUPPORT
     p2hex supports national languages in the same way as AS.	See  the  manual
     page for asl(1) for more information about this.

TIPS
     Calling  P2HEX  without  any  arguments will print a short help listing all
     command line parameters.

SEE ALSO
     asl(1), plist(1), pbind(1), p2bin(1)

HISTORY
     P2HEX originally appeared as an AS tool in 1992, written in Borland-Pascal,
     and was ported to C and UNIX in 1996.

BUGS
     Command line interpreters of some operating systems reserve some characters
     for their own use, so it might be necessary to give command line parameters
     with certain tricks (e.g., with the help of escape characters).

     P2HEX does not have so far an opportunity to filter records by target  seg-
     ment.   Instead,  records that contain data for any other segment than CODE
     are completely ignored.

AUTHOR(S)
     Alfred Arnold (alfred@ccac.rwth-aachen.de)

									p2hex(1)