PACEMAKER-BASED(7)	     Pacemaker Configuration	      PACEMAKER-BASED(7)

NAME
     pacemaker-based - Cluster Information Base manager options

SYNOPSIS
     [enable-acl=boolean] [cluster-ipc-limit=integer]

DESCRIPTION
     Cluster options used by Pacemaker's Cluster Information Base manager

SUPPORTED PARAMETERS
     enable-acl = boolean [false]
	 Enable Access Control Lists (ACLs) for the CIB

     cluster-ipc-limit = integer [500]
	 Maximum IPC message backlog before disconnecting a cluster daemon

	 Raise	this  if  log  has "Evicting client" messages for cluster daemon
	 PIDs (a good value is the number of resources in the cluster multiplied
	 by the number of nodes).