RRDTOOL(1)			     rrdtool			      RRDTOOL(1)

NAME
     rrdtool - Round Robin Database Tool

SYNOPSIS
     rrdtool - [workdir]| function

DESCRIPTION
   OVERVIEW
     It  is  pretty  easy to gather status information from all sorts of things,
     ranging from the temperature in your office to the number of  octets  which
     have  passed  through  the  FDDI interface of your router. But it is not so
     trivial to store this data in an efficient and systematic manner.	This  is
     where  RRDtool  comes  in	handy.	It lets you log and analyze the data you
     gather from all kinds of data-sources (DS). The data analysis part of  RRD-
     tool  is based on the ability to quickly generate graphical representations
     of the data values collected over a definable time period.

     In this man page you will find general information on the design and  func-
     tionality	of  the Round Robin Database Tool (RRDtool). For a more detailed
     description of how to use the individual functions  of  RRDtool  check  the
     corresponding man page.

     For  an introduction to the usage of RRDtool make sure you consult the rrd-
     tutorial.

   FUNCTIONS
     While the man pages talk of command line switches you have to set in  order
     to  make  RRDtool work it is important to note that RRDtool can be remotely
     controlled through a set of pipes. This  saves  a	considerable  amount  of
     startup  time  when  you  plan  to make RRDtool do a lot of things quickly.
     Check the section on "REMOTE CONTROL" further down. There is also a  number
     of  language  bindings  for RRDtool which allow you to use it directly from
     Perl, python, Tcl, PHP, etc.

     create  Set up a new Round Robin Database (RRD). Check rrdcreate.

     update  Store new data values into an RRD. Check rrdupdate.

     updatev Operationally equivalent to update except for output. Check  rrdup-
	     date.

     graph   Create  a graph from data stored in one or several RRDs. Apart from
	     generating graphs, data can also be extracted to stdout. Check rrd-
	     graph.

     graphv  Create a graph from data stored in one or	several  RRDs.	Same  as
	     graph, but metadata are printed before the graph. Check rrdgraph.

     dump    Dump  the contents of an RRD in plain ASCII. In connection with re-
	     store you can use this to move an RRD from one  computer  architec-
	     ture to another.  Check rrddump.

     restore Restore an RRD in XML format to a binary RRD. Check rrdrestore

     fetch   Get  data	for a certain time period from a RRD. The graph function
	     uses fetch to retrieve its data from an RRD. Check rrdfetch.

     tune    Alter setup and structure of an RRD. Check rrdtune.

     first   Find the first update time of an RRD. Check rrdfirst.

     last    Find the last update time of an RRD. Check rrdlast.

     lastupdate
	     Find the last update time of an RRD.  It  also  returns  the  value
	     stored  for  each datum in the most recent update. Check rrdlastup-
	     date.

     info    Get information about an RRD. Check rrdinfo.

     resize  Change the size of individual RRAs. This is dangerous! Check rrdre-
	     size.

     xport   Export data retrieved from one or several RRDs. Check rrdxport.

     flushcached
	     Flush the values for a specific RRD file from  memory.  Check  rrd-
	     flushcached.

     list    List the directories and rrd databases remotely. Check rrdlist.

   HOW DOES RRDTOOL WORK?
     Data Acquisition
	     When monitoring the state of a system, it is convenient to have the
	     data  available at a constant time interval. Unfortunately, you may
	     not always be able to fetch data at exactly the time you  want  to.
	     Therefore	RRDtool  lets  you  update  the log file at any time you
	     want. It will automatically interpolate  the  value  of  the  data-
	     source  (DS)  at the latest official time-slot (interval) and write
	     this interpolated value to the log. The  original	value  you  have
	     supplied  is stored as well and is also taken into account when in-
	     terpolating the next log entry.

     Consolidation
	     You may log data at a 1 minute interval, but you might also be  in-
	     terested  to  know  the development of the data over the last year.
	     You could do this by simply storing the data in 1 minute  intervals
	     for  the  whole year. While this would take considerable disk space
	     it would also take a lot of time  to  analyze  the  data  when  you
	     wanted  to create a graph covering the whole year. RRDtool offers a
	     solution to this problem through its  data  consolidation	feature.
	     When  setting  up	a  Round Robin Database (RRD), you can define at
	     which interval this consolidation should occur, and what consolida-
	     tion function (CF) (average, minimum, maximum, last) should be used
	     to build the consolidated values (see rrdcreate).	You  can  define
	     any  number  of different consolidation setups within one RRD. They
	     will all be maintained on the fly when new data is loaded into  the
	     RRD.

     Round Robin Archives
	     Data  values  of the same consolidation setup are stored into Round
	     Robin Archives (RRA). This is a very efficient manner to store data
	     for a certain amount of time, while  using  a  known  and	constant
	     amount of storage space.

	     It  works	like this: If you want to store 1'000 values in 5 minute
	     interval, RRDtool will allocate space for 1'000 data values  and  a
	     header  area.  In	the header it will store a pointer telling which
	     slots (value) in the storage area was last written to.  New  values
	     are  written to the Round Robin Archive in, you guessed it, a round
	     robin manner. This automatically limits the  history  to  the  last
	     1'000  values (in our example). Because you can define several RRAs
	     within a single RRD, you can setup another  one,  for  storing  750
	     data  values at a 2 hour interval, for example, and thus keep a log
	     for the last two months at a lower resolution.

	     The use of RRAs guarantees that the RRD does not grow over time and
	     that old data is automatically eliminated. By using the  consolida-
	     tion  feature,  you can still keep data for a very long time, while
	     gradually reducing the resolution of the data along the time axis.

	     Using different consolidation functions (CF) allows  you  to  store
	     exactly  the  type  of information that actually interests you: the
	     maximum one minute traffic on the LAN, the minimum  temperature  of
	     your wine cellar, ... etc.

     Unknown Data
	     As  mentioned  earlier, the RRD stores data at a constant interval.
	     Sometimes it may happen that no new data is available when a  value
	     has  to be written to the RRD. Data acquisition may not be possible
	     for one reason or other. With RRDtool you can handle  these  situa-
	     tions  by	storing  an *UNKNOWN* value into the database. The value
	     '*UNKNOWN*' is supported through all the  functions  of  the  tool.
	     When  consolidating a data set, the amount of *UNKNOWN* data values
	     is accounted for and when a new consolidated value is ready  to  be
	     written  to its Round Robin Archive (RRA), a validity check is per-
	     formed to make sure that the percentage of unknown  values  in  the
	     data  point  is  above  a	configurable level. If not, an *UNKNOWN*
	     value will be written to the RRA.

     GraphingRRDtool allows you to generate reports in numerical  and  graphical
	     form  based on the data stored in one or several RRDs. The graphing
	     feature is fully configurable. Size,  color  and  contents  of  the
	     graph can be defined freely. Check rrdgraph for more information on
	     this.

     Aberrant Behavior Detection
	     by Jake Brutlag

	     RRDtool  provides	the  building blocks for near real-time aberrant
	     behavior detection. These components include:

	     *	 An algorithm for predicting the value of a time series one time
		 step into the future.

	     *	 A measure of deviation between predicted and observed values.

	     *	 A mechanism to decide if and when an observed value or sequence
		 of observed values is too deviant from the predicted value(s).

	     Here is a brief explanation of these components:

	     The Holt-Winters time series forecasting algorithm  is  an  on-line
	     (or incremental) algorithm that adaptively predicts future observa-
	     tions  in	a  time  series. Its forecast is the sum of three compo-
	     nents: a baseline (or intercept), a  linear  trend  over  time  (or
	     slope),  and  a  seasonal coefficient (a periodic effect, such as a
	     daily cycle). There is one seasonal coefficient for each time point
	     in the period (cycle). After a value is  observed,  each  of  these
	     components  is  updated  via exponential smoothing. This means that
	     the algorithm "learns" from past values and uses  them  to  predict
	     the future. The rate of adaptation is governed by 3 parameters, al-
	     pha (intercept), beta (slope), and gamma (seasonal). The prediction
	     can also be viewed as a smoothed value for the time series.

	     The measure of deviation is a seasonal weighted absolute deviation.
	     The  term	seasonal means deviation is measured separately for each
	     time point in the seasonal cycle. As with Holt-Winters forecasting,
	     deviation is predicted using the measure computed from past  values
	     (but  only at that point in the seasonal cycle). After the value is
	     observed, the algorithm learns from the observed value via exponen-
	     tial smoothing. Confidence bands for the observed time  series  are
	     generated by scaling the sequence of predicted deviation values (we
	     usually  think  of  the sequence as a continuous line rather than a
	     set of discrete points).

	     Aberrant behavior (a potential failure) is  reported  whenever  the
	     number  of  times	the observed value violates the confidence bands
	     meets or exceeds a specified threshold within a specified	temporal
	     window  (e.g.  5 violations during the past 45 minutes with a value
	     observed every 5 minutes).

	     This functionality is embedded in a set of related RRAs. In partic-
	     ular, a FAILURES RRA logs potential failures. With these  data  you
	     could,  for example, use a front-end application to RRDtool to ini-
	     tiate real-time alerts.

	     For a detailed description on how to set this up, see rrdcreate.

   REMOTE CONTROL
     When you start RRDtool with the command line option '-' it waits for  input
     via  standard  input (STDIN). With this feature you can improve performance
     by attaching RRDtool to another process (MRTG is one example) through a set
     of pipes. Over these pipes RRDtool accepts the same  arguments  as  on  the
     command  line  and  some special commands like cd, mkdir, pwd, ls and quit.
     For detailed help on the server commands type:

	rrdtool help cd

     When a command is completed, RRDtool will print the  string   '"OK"',  fol-
     lowed  by	timing information of the form u:usertime s:systemtimer:runtime.
     The usertime and systemtime values are the running totals of seconds  since
     RRDtool  was  started.  runtime is the total amount of seconds that RRDtool
     has been running.	If an error occurs, a line of  the  form  '"ERROR:"  De-
     scription of error' will be printed instead. RRDtool will not abort, unless
     something	really serious happens. If a workdir is specified and the UID is
     0, RRDtool will do a chroot to that workdir. If the UID is not  0,  RRDtool
     only changes the current directory to workdir.

   RRD Server
     If you want to create a RRD-Server, you must choose a TCP/IP Service number
     and add them to /etc/services like this:

      rrdsrv	  13900/tcp			  # RRD server

     Attention:  the  TCP port 13900 isn't officially registered for rrdsrv. You
     can use any unused port in your services  file,  but  the	server	and  the
     client system must use the same port, of course.

     With  this  configuration	you  can  add RRDtool as meta-server to /etc/in-
     etd.conf. For example:

      rrdsrv stream tcp nowait root /opt/rrd/bin/rrdtool rrdtool - /var/rrd

     Don't forget to create the database  directory  /var/rrd  and  reinitialize
     your inetd.

     If  all  was  setup correctly, you can access the server with Perl sockets,
     tools like netcat, or in a quick interactive test by using  'telnet  local-
     host rrdsrv'.

     NOTE:  that there is no authentication with this feature! Do not setup such
     a port unless you are sure what you are doing.

ENVIRONMENT VARIABLES
     The following environment variables may be used to change the  behavior  of
     most of the utilities.

     RRD_LOCKING
	 If  this  environment	variable  is  set, the RRD file is locked in the
	 given mode:

	 -   try fails, when the file is locked by another process.  This is the
	     default.

	 -   block waits until the lock is released.

	 -   none skips locking at all.  Caller has to ensure a  proper  locking
	     which should be compatible with "fcntl(fd, F_SETLK, ...)".

	 Some  utilities  have	command  line options (--locking) which override
	 this variable.

RRDCACHED, THE CACHING DAEMON
     For very big setups, updating thousands of RRD files often becomes a  seri-
     ous  IO  problem.	If  you run into such problems, you might want to take a
     look at rrdcached, a caching daemon for RRDtool which may help  you  lessen
     the stress on your disks.

SEE ALSO
     rrdcreate,  rrdupdate, rrdgraph, rrddump, rrdfetch, rrdtune, rrdlast, rrdx-
     port, rrdflushcached, rrdcached

BUGS
     Bugs? Features!

AUTHOR
     Tobias Oetiker <tobi@oetiker.ch>

1.10.3				   2026-05-25			      RRDTOOL(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=rrdtool&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help