NAME
     sane - Scanner Access Now Easy: API for accessing scanners

DESCRIPTION
     SANE  is an application programming interface (API) that provides standard-
     ized access to any raster image scanner hardware. The  standardized  inter-
     face makes it possible to write just one driver for each scanner device in-
     stead of one driver for each scanner and application.

     While  SANE  is  primarily targeted at a UNIX environment, the standard has
     been carefully designed to make it possible to implement the API on  virtu-
     ally any hardware or operating system.

     This  manual  page  provides  a  summary of the information available about
     SANE.

     If you have trouble getting your scanner detected, read the  PROBLEMS  sec-
     tion.

TERMINOLOGY
     An  application  that uses the SANE interface is called a SANE frontend.  A
     driver that implements the SANE interface is called a SANE backend.  A meta
     backend provides some means to manage one or more other backends.

SOFTWARE PACKAGES
     The package sane-backends contains backends, documentation, networking sup-
     port, and the command line frontend scanimage(1).	The  frontends	xscanim-
     age(1), xcam(1), and scanadf(1) are included in the package sane-frontends.
     Both    packages	 can	be    downloaded    from   the	 SANE	homepage
     (http://www.sane-project.org/).   Information  about  other  frontends  and
     backends can also be found on the SANE homepage.

GENERAL INFORMATION
     The  following sections provide short descriptions and links to more infor-
     mation about several aspects of SANE.  A name with a number in  parenthesis
     (e.g.   sane-dll(5))  points  to a manual page. In this case man 5 sane-dll
     will  display  the  page.	Entries   like	 /usr/local/share/doc/sane-back-
     ends/README are references to text files that were copied to the SANE docu-
     mentation	directory (/usr/local/share/doc/sane-backends/) during installa-
     tion. Everything else is a URL to a resource on the web.

     SANE homepage
       Information on all aspects of SANE including a tutorial and a link to the
       SANE FAQ can be found on the SANE homepage: http://www.sane-project.org/.

     SANE device lists
       The SANE device lists contain information about the status of  SANE  sup-
       port  for  a specific device. If your scanner is not listed there (either
       supported or unsupported), please contact us. See  section  HOW	CAN  YOU
       HELP SANE for details. There are lists for specific releases of SANE, for
       the    current	 development	version    and	  a    search	 engine:
       http://www.sane-project.org/sane-supported-devices.html.  The  lists  are
       also installed on your system at /usr/local/share/doc/sane-backends/.

     SANE mailing list
       There  is  a mailing list for the purpose of discussing the SANE standard
       and its implementations: sane-devel.  Despite its name, the list  is  not
       only  intended  for  developers,  but also for users. There are also some
       more lists for special topics. However,	for  users,  sane-devel  is  the
       right	  list.      How      to      subscribe     and     unsubscribe:
       http://www.sane-project.org/mailing-lists.html.

     SANE IRC channel
       The IRC (Internet Relay Chat) channel #sane can be found on the	Freenode
       network	(irc.libera.chat).  It's  for  discussing SANE problems, talking
       about development and general SANE related chatting.  Before  asking  for
       help,  please read the other documentation mentioned in this manual page.
       The channel's topic is also used for announcements of problems with  SANE
       infrastructure (mailing lists, web server, etc.).

     Compiling and installing SANE
       Look  at  /usr/local/share/doc/sane-backends/README  and the os-dependent
       README files for information about compiling and installing SANE.

     SCSI configuration
       For  information  about	various  systems  and	SCSI   controllers   see
       sane-scsi(5).

     USB configuration
       For information about USB configuration see sane-usb(5).

FRONTENDS AND MISCELLANEOUS PROGRAMS
     scanimage
       Command-line frontend. See scanimage(1).

     saned
       SANE  network  daemon that allows remote clients to access image acquisi-
       tion devices available on the local host. See saned(8).

     sane-find-scanner
       Command-line tool to find SCSI and USB scanners and determine their  UNIX
       device files. See sane-find-scanner(1).

     Also,  have  a  look at the sane-frontends package (which includes xscanim-
     age(1), xcam(1), and scanadf(1))  and  the  frontend  information	page  at
     http://www.sane-project.org/sane-frontends.html.

BACKENDS FOR SCANNERS
     abaton
       Supports  Abaton flatbed scanners such as the Scan 300/GS (8bit, 256 lev-
       els of gray)  and  the  Scan  300/S  (black  and  white,  untested).  See
       sane-abaton(5) for details.

     agfafocus
       Supports  AGFA  Focus  scanners	and  the  Siemens S9036 (untested).  See
       sane-agfafocus(5) for details.

     apple
       Supports Apple flatbed scanners including the following scanners: AppleS-
       canner, OneScanner and ColorOneScanner. See sane-apple(5) for details.

     artec
       Supports several Artec/Ultima SCSI flatbed scanners as well as the Black-
       Widow BW4800SP and the Plustek 19200S. See sane-artec(5) for details.

     artec_eplus48u
       Supports the Artec E+ 48U scanner and re-badged	models	like  Tevion  MD
       9693,  Medion  MD  9693, Medion MD 9705 and Trust Easy Webscan 19200. See
       sane-artec_eplus48u(5) for details.

     as6e
       Supports the Artec AS6E parallel port interface scanner. See sane-as6e(5)
       for details.

     avision
       Supports several Avision based scanners including  the  original  Avision
       scanners  (like	AV  630, AV 620, ...) as well as the HP ScanJet 53xx and
       74xx series, Fujitsu ScanPartner, some Mitsubishi and Minolta  film-scan-
       ners.  See sane-avision(5) for details.

     bh
       Supports Bell+Howell Copiscan II series document scanners. See sane-bh(5)
       for details.

     canon
       Supports  the CanoScan 300, CanoScan 600, and CanoScan 2700F SCSI flatbed
       scanners. See sane-canon(5) for details.

     canon630u
       Supports the CanoScan 630u and 636u USB scanners.  See  sane-canon630u(5)
       for details.

     canon_dr
       Supports   the	Canon	DR-Series   ADF   SCSI	and  USB  scanners.  See
       sane-canon_dr(5) for details.

     canon_lide70
       Supports   the	CanoScan   LiDE   70   and   600   USB	 scanners.   See
       sane-canon_lide70(5) for details.

     canon_pp
       Supports the CanoScan FB330P, FB630P, N340P and N640P parallel port scan-
       ners.  See sane-canon_pp(5) for details.

     cardscan
       Support	for  Corex  Cardscan  USB scanners. See sane-cardscan(5) for de-
       tails.

     coolscan coolscan2 coolscan3
       Supports   Nikon   Coolscan    film-scanners.	See    sane-coolscan(5),
       sane-coolscan2(5) and sane-coolscan3(5) for details.

     epjitsu
       Supports  Epson-based  Fujitsu  USB scanners. See sane-epjitsu(5) for de-
       tails.

     epson
       Old driver for Epson SCSI, parallel port and USB  flatbed  scanners.  See
       sane-epson(5) for details but try epson2 first.

     epson2
       Newer driver for Epson SCSI, parallel port, network and USB flatbed scan-
       ners  (try  this  before epson which is outdated). See sane-epson2(5) for
       details.

     escl
       Supports scanners through the eSCL protocol.  See  sane-escl(5)	for  de-
       tails.

     fujitsu
       Supports  most  Fujitsu	SCSI  and  USB,  flatbed  and  adf scanners. See
       sane-fujitsu(5) for details.

     genesys
       Supports several scanners based on the Genesys Logic GL646, GL841, GL843,
       GL847 and GL124 chips like the Medion  6471  and  Hewlett-Packard  2300c.
       See sane-genesys(5) for details.

     gt68xx
       Supports  scanners  based on the Grandtech GT-6801 and GT-6816 chips like
       the Artec Ultima 2000 and several Mustek BearPaw CU and TA models.
       Some Genius, Lexmark, Medion, Packard Bell, Plustek, and  Trust	scanners
       are also supported. See sane-gt68xx(5) for details.

     hp
       Supports Hewlett-Packard ScanJet scanners which utilize SCL (Scanner Con-
       trol Language by HP). See sane-hp(5) for details.

     hpsj5s
       Supports  the  Hewlett-Packard ScanJet 5S scanner. See sane-hpsj5s(5) for
       details.

     hp3500
       Supports the Hewlett-Packard ScanJet 3500 series. See sane-hp3500(5)  for
       details.

     hp3900
       Supports  the Hewlett-Packard ScanJet 3900 series. See sane-hp3900(5) for
       details.

     hp4200
       Supports the Hewlett-Packard ScanJet 4200 series. See sane-hp4200(5)  for
       details.

     hp5400
       Supports the Hewlett-Packard ScanJet 54XXC series. See sane-hp5400(5) for
       details.

     hpljm1005
       Supports    the	  Hewlett-Packard    LaserJet	 M1005	  scanner.   See
       sane-hpljm1005(5) for details.

     hs2p
       Supports the Ricoh IS450 family of SCSI scanners.  See  sane-hs2p(5)  for
       details.

     ibm
       Supports some IBM and Ricoh SCSI scanners. See sane-ibm(5) for details.

     kodak
       Supports some large Kodak scanners. See sane-kodak(5) for details.

     kodakaio
       Supports Kodak AiO printer/scanners. See sane-kodakaio(5) for details.

     kvs1025
       Supports Panasonic KV-S102xC scanners. See sane-kvs1025(5) for details.

     leo
       Supports  the  LEO  S3  and  the Across FS-1130, which is a re-badged LEO
       FS-1130 scanner. See sane-leo(5) for details.

     lexmark
       Supports the Lexmark X1100 series of USB  scanners.  See  sane-lexmark(5)
       for details.

     lexmark_x2600
       Supports  the  Lexmark  X2600  series  of  USB  scanners.  See  sane-lex-
       mark_x2600(5) for details.

     ma1509
       Supports the Mustek BearPaw 1200F USB flatbed scanner. See sane-ma1509(5)
       for details.

     magicolor
       Supports the KONICA MINOLTA magicolor 1690MF multi-function printer/scan-
       ner/fax. See sane-magicolor(5) for details.

     matsushita
       Supports some Panasonic KVSS high speed scanners. See  sane-matsushita(5)
       for details.

     microtek
       Supports  "second  generation" Microtek scanners with SCSI-1 command set.
       See sane-microtek(5) for details.

     microtek2
       Supports some Microtek scanners with a SCSI-2 command set.  See	sane-mi-
       crotek2(5) for details.

     mustek
       Supports  most  Mustek  SCSI  flatbed  scanners including the Paragon and
       ScanExpress series and the 600 II N and 600 II EP (non-SCSI). Some  Trust
       scanners are also supported. See sane-mustek(5) for details.

     mustek_pp
       Supports Mustek parallel port flatbed scanners. See sane-mustek_pp(5) for
       details.

     mustek_usb
       Supports    some   Mustek   ScanExpress	 USB   flatbed	 scanners.   See
       sane-mustek_usb(5) for details.

     mustek_usb2
       Supports scanners using the SQ113 chipset like the Mustek BearPaw 2448 TA
       Pro USB flatbed scanner. See sane-mustek_usb2(5) for details.

     nec
       Supports the NEC PC-IN500/4C SCSI scanner. See sane-nec(5) for details.

     niash
       Supports the Agfa Snapscan Touch and the HP  ScanJet  3300c,  3400c,  and
       4300c USB flatbed scanners. See sane-niash(5) for details.

     p5
       Supports the Primax PagePartner. See sane-p5(5) for details.

     pie
       Supports  Pacific  Image  Electronics (PIE) and Devcom SCSI flatbed scan-
       ners. See sane-pie(5) for details.

     pixma
       Supports Canon PIXMA MP series (multi-function devices), Canon imageCLASS
       series (laser devices), Canon MAXIFY series and some Canon  CanoScan  se-
       ries. See sane-pixma(5) for details.

     plustek
       Supports  USB  flatbed  scanners  that  use  the  National  Semiconductor
       LM983[1/2/3] chipset aka Merlin. Scanners using this LM983x chips include
       some models from Plustek, KYE/Genius, Hewlett-Packard, Mustek, Umax,  Ep-
       son, and Canon. See sane-plustek(5) for details.

     plustek_pp
       Supports  Plustek  parallel  port flatbed scanners using the Plustek ASIC
       P96001, P96003, P98001 and P98003, which includes some models from  Plus-
       tek, KYE/Genius, Primax. See sane-plustek_pp(5) for details.

     ricoh
       Supports  the Ricoh flatbed scanners IS50 and IS60. See sane-ricoh(5) for
       details.

     ricoh2
       Supports the Ricoh flatbed scanners: SG-3100SNw, SP-100SU, and  SP-111SU.
       See sane-ricoh2(5) for details.

     s9036
       Supports Siemens 9036 flatbed scanners. See sane-s9036(5) for details.

     sceptre
       Supports  the  Sceptre S1200 flatbed scanner. See sane-sceptre(5) for de-
       tails.

     sharp
       Supports Sharp SCSI scanners. See sane-sharp(5) for details.

     sm3600
       Supports the Microtek ScanMaker 3600 USB scanner. See sane-sm3600(5)  for
       details.

     sm3840
       Supports the Microtek ScanMaker 3840 USB scanner.  See sane-sm3840(5) for
       details.

     snapscan
       Supports AGFA SnapScan flatbed scanners including some which are rebadged
       to other brands. See sane-snapscan(5) for details.

     sp15c
       Supports   the	Fujitsu   FCPA	ScanPartner  15C  flatbed  scanner.  See
       sane-sp15c(5) for details.

     st400
       Supports the Siemens ST400 and ST800. See sane-st400(5) for details.

     tamarack
       Supports Tamarack Artiscan flatbed scanners. See sane-tamarack(5) for de-
       tails.

     teco1 teco2 teco3
       Supports some TECO scanners, usually sold under the Relisys, Trust,  Pri-
       max,   Piotech,	 Dextra  names.  See  sane-teco1(5),  sane-teco2(5)  and
       sane-teco3(5) for details.

     u12
       Supports USB flatbed scanners based on Plustek's  ASIC  98003  (parallel-
       port ASIC) and a GeneSys Logics' USB-parport bridge chip like the Plustek
       OpticPro U(T)12. See sane-u12(5) for details.

     umax
       Supports  UMAX-SCSI-scanners  and  some	Linotype Hell SCSI-scanners. See
       sane-umax(5) for details.

     umax_pp
       Supports Umax parallel port  flatbed  scanners  and  the  HP  3200C.  See
       sane-umax_pp(5) for details.

     umax1200u
       Supports  the  UMAX  Astra 1220U (USB) flatbed scanner (and also the UMAX
       Astra 2000U, sort of). See sane-umax1220u(5) for details.

     xerox_mfp
       Supports multiple Samsung-based Samsung, Xerox, and  Dell  scanners.  See
       sane-xerox_mfp(5) for details.

     Also,    have    a    look    at	 the   backend	 information   page   at
     http://www.sane-project.org/sane-supported-devices.html  and  the	list  of
     projects in /usr/local/share/doc/sane-backends/PROJECTS.

BACKENDS FOR DIGITAL CAMERAS
     dc210
       Supports the Kodak DC210 Digital Camera. See sane-dc210(5).

     dc240
       Supports the Kodak DC240 Digital Camera. See dc240(5).

     dc25
       Supports Kodak DC20/DC25 Digital Cameras. See dc25(5).

     dmc
       Supports the Polaroid Digital Microscope Camera. See dmc(5).

     gphoto2
       Supports  digital cameras supported by the gphoto2 library package.  (See
       http://www.gphoto.org for more information and a list of  supported  cam-
       eras.)	Gphoto2  supports  over  140  different camera models.	However,
       please note that more development and testing is  needed  before  all  of
       these cameras will be supported by SANE backend.  See gphoto2(5).

     qcam
       Supports Connectix QuickCam cameras. See qcam(5).

     stv680
       Supports webcams with a stv680 chip. See stv680(5) for details.

     Also,    have    a    look    at	 the   backend	 information   page   at
     http://www.sane-project.org/sane-supported-devices.html  and  the	list  of
     projects in /usr/local/share/doc/sane-backends/PROJECTS.

MISCELLANEOUS BACKENDS
     dll
       Implements  a SANE backend that provides access to an arbitrary number of
       other SANE backends by dynamic loading. See sane-dll(5).

     net
       The SANE network daemon saned(8) provides access to scanners  located  on
       different  computers  in  connection  with  the	sane-net(5) backend. See
       saned(8).

     pnm
       PNM image reader pseudo-backend. The purpose of this backend is primarily
       to aid in debugging of SANE frontends. See sane-pnm(5).

     pint
       Supports scanners that use the PINT (Pint Is Not  Twain)  device  driver.
       The  PINT driver is being actively developed on the OpenBSD platform, and
       has  been  ported  to  a  few  other  *NIX-like	operating  systems.  See
       sane-pint(5).

     test
       Tests frontends and the SANE installation.  It provides test pictures and
       various test options. See sane-test(5).

     v4l
       Provides  generic access to video cameras and similar equipment using the
       V4L (Video for Linux) API. See sane-v4l(5).

     Also,   have   a	look   at    the    backend    information    page    at
     http://www.sane-project.org/sane-supported-devices.html  and  the	list  of
     projects in /usr/local/share/doc/sane-backends/PROJECTS.

CHANGING THE TOP-LEVEL BACKEND
     By default, all SANE backends  (drivers)  are  loaded  dynamically  by  the
     sane-dll meta backend. If you have any questions about the dynamic loading,
     read  sane-dll(5).  SANE frontends can also be linked to other backends di-
     rectly  by  copying  or  linking  a  backend  to  libsane.so  in	/usr/lo-
     cal/lib/sane.

DEVELOPER'S DOCUMENTATION
     It's  not hard to write a SANE backend. It can take some time, however. You
     should have basic knowledge of C and enough patience to  work  through  the
     documentation  and  find  out how your scanner works. Appended is a list of
     some documents that help to write backends and frontends.

     The SANE standard defines the application programming interface (API)  that
     is  used  to communicate between frontends and backends. It can be found at
     http://sane-project.gitlab.io/standard/ .

     There   is   some	 more	information   for   programmers   in	/usr/lo-
     cal/share/doc/sane-backends/backend-writing.txt.  Most of the internal SANE
     routines	    (sanei)	  are	    documented	     using	doxygen:
     http://www.sane-project.org/sanei/.   Before  a  new  backend  or	frontend
     project   is   started,  have  a  look  at  /usr/local/share/doc/sane-back-
     ends/PROJECTS for projects that are planned or not yet  included  into  the
     SANE      distribution	 and	 at	our	bug-tracking	 system:
     http://www.http://www.sane-project.org/bugs.html.

     There are some links on how to find out about the protocol  of  a	scanner:
     http://www.meier-geinitz.de/sane/misc/develop.html.

     If  you  start  writing  a  backend  or frontend or any other part of SANE,
     please contact the sane-devel mailing list for coordination so that work is
     not duplicated.

FILES
     /usr/local/etc/sane.d/*.conf
	    The backend configuration files.

     /usr/local/lib/sane/libsane-*.a
	    The static libraries implementing the backends.

     /usr/local/lib/sane/libsane-*.so
	    The shared libraries implementing the backends (present  on  systems
	    that support dynamic loading).

     /usr/local/share/doc/sane-backends/*
	    SANE documentation: The READMEs, text files for backends etc.

PROBLEMS
     If  your  device  isn't  found but you know that it is supported, make sure
     that it is detected by your operating system. For SCSI  and  USB  scanners,
     use  the sane-find-scanner(1) utility.  It prints one line for each scanner
     it has detected and some comments (#).  If sane-find-scanner(1) finds  your
     scanner only as root but not as normal user, the permissions for the device
     files  are  not  adjusted correctly. If the scanner isn't found at all, the
     operating system hasn't detected it and may need some  help.  Depending  on
     the  type of your scanner, read sane-usb(5) or sane-scsi(5).  If your scan-
     ner (or other device) is not connected over the SCSI bus or USB,  read  the
     backend's manual page for details on how to set it up.

     Is  your  scanner	detected  by  the operating system but not by SANE?  Try
     scanimage -L.  If the scanner is not found, check that the  backend's  name
     is  mentioned  in	/usr/local/etc/sane.d/dll.conf.   Some backends are com-
     mented out by default. Remove the comment sign for  your  backend	in  this
     case.  Also  some backends aren't compiled at all if one of their prerequi-
     sites  are  missing.  Examples  include  dc210,  dc240,  canon_pp,  hpsj5s,
     gphoto2,  pint,  qcam,  v4l, net, sm3600, snapscan, pnm. If you need one of
     these backends and it isn't available, read the build instructions  in  the
     README file and the individual manual pages of the backends.

     Another  reason  for not being detected by scanimage -L may be a missing or
     incorrect configuration in the backend's  configuration  file.  While  SANE
     tries  to	automatically  find most scanners, some can't be setup correctly
     without the intervention of the administrator. Also on some operating  sys-
     tems  auto-detection  may not work. Check the backend's manual page for de-
     tails.

     If your scanner is still not found, try  setting  the  various  environment
     variables that are available to assist in debugging.  The environment vari-
     ables are documented in the relevant manual pages.  For example, to get the
     maximum amount of debug information when testing a Mustek SCSI scanner, set
     environment   variables  SANE_DEBUG_DLL,  SANE_DEBUG_MUSTEK,  and	SANE_DE-
     BUG_SANEI_SCSI to 128 and then  invoke  scanimage -L.   The  SANE_DEBUG_DLL
     messages  tell  if  the sane-mustek(5) backend was found and loaded at all.
     The SANE_DEBUG_MUSTEK messages explain what the backend is doing while  the
     SANE_DEBUG_SCSI  debugging  shows the low level handling. If you can't find
     out what's going  on  by  checking  the  messages	carefully,  contact  the
     sane-devel mailing list for help (see REPORTING BUGS below).

     Now  that	your scanner is found by scanimage -L, try to do a scan: scanim-
     age >image.pnm.  This command starts a scan for the  default  scanner  with
     default  settings.  All the available options are listed by running scanim-
     age --help.  If scanning aborts with an error message, turn on debugging as
     mentioned above. Maybe the configuration file needs some  tuning,	e.g.  to
     setup the path to a firmware that is needed by some scanners. See the back-
     end's  manual page for details. If you can't find out what's wrong, contact
     sane-devel.

     To check that the SANE libraries are installed correctly you  can	use  the
     test backend, even if you don't have a scanner or other SANE device:

	    scanimage -d test -T

     You  should get a list of PASSed tests. You can do the same with your back-
     end by changing "test" to your backend's name.

     So now scanning with scanimage (1) works and you want to  use  one  of  the
     graphical	frontends  like  xsane(1),  xscanimage(1), or quiteinsane(1) but
     those frontends don't detect your scanner? One reason may be that	you  in-
     stalled  two versions of SANE.  E.g. the version that was installed by your
     distribution in /usr and one you  installed  from	source	in  /usr/local/.
     Make  sure  that only one version is installed. Another possible reason is,
     that your system's dynamic loader can't find the SANE libraries. For Linux,
     make sure that /etc/ld.so.conf contains /usr/local/lib and does not contain
     /usr/local/lib/sane.  See also the documentation of the frontends.

HOW CAN YOU HELP SANE
     We appreciate any help we can get. Please have a look at our web page about
     contributing to SANE: http://www.sane-project.org/contrib.html

CONTACT
     For reporting bugs or requesting new features, please use our  bug-tracking
     system:  http://www.sane-project.org/bugs.html.   You  can also contact the
     author of your backend directly. Usually the email address can be found  in
     the  /usr/local/share/doc/sane-backends/AUTHORS  file or the backend's man-
     page. For general discussion about SANE, please use the SANE  mailing  list
     sane-devel   (see	http://www.sane-project.org/mailing-lists.html	for  de-
     tails).

SEE ALSO
     saned(8), sane-find-scanner(1), scanimage(1), sane-abaton(5),  sane-agfafo-
     cus(5), sane-apple(5), sane-artec(5), sane-artec_eplus48u(5), sane-as6e(5),
     sane-avision(5),	   sane-bh(5),	   sane-canon(5),     sane-canon630u(5),
     sane-canon_dr(5),	sane-canon_pp(5),  sane-cardscan(5),   sane-coolscan(5),
     sane-coolscan2(5),    sane-coolscan3(5),	 sane-dc210(5),   sane-dc240(5),
     sane-dc25(5),  sane-dll(5),  sane-dmc(5),	sane-epson(5),	 sane-epson2(5),
     sane-escl(5),     sane-fujitsu(5),     sane-genesys(5),	sane-gphoto2(5),
     sane-gt68xx(5), sane-hp(5), sane-hpsj5s(5), sane-hp3500(5), sane-hp3900(5),
     sane-hp4200(5), sane-hp5400(5),  sane-hpljm1005(5),  sane-ibm(5),	sane-ko-
     dak(5),	  sane-leo(5),	    sane-lexmark(5),	  sane-lexmark_x2600(5),
     sane-ma1509(5),  sane-matsushita(5),  sane-microtek2(5),  sane-microtek(5),
     sane-mustek(5), sane-mustek_pp(5), sane-mustek_usb(5), sane-mustek_usb2(5),
     sane-nec(5),   sane-net(5),   sane-niash(5),   sane-pie(5),   sane-pint(5),
     sane-plustek(5), sane-plustek_pp(5),  sane-pnm(5),  sane-qcam(5),	sane-ri-
     coh(5),   sane-ricoh2(5),	 sane-s9036(5),  sane-sceptre(5),  sane-scsi(5),
     sane-sharp(5),    sane-sm3600(5),	   sane-sm3840(5),     sane-snapscan(5),
     sane-sp15c(5),	sane-st400(5),	   sane-stv680(5),     sane-tamarack(5),
     sane-teco1(5),  sane-teco2(5),  sane-teco3(5),  sane-test(5),  sane-u12(5),
     sane-umax1220u(5), sane-umax(5), sane-umax_pp(5), sane-usb(5), sane-v4l(5),
     sane-xerox_mfp(5)

AUTHOR
     David  Mosberger-Tang  and  many  many more (see /usr/local/share/doc/sane-
     backends/AUTHORS for details).  This man page was written by Henning Meier-
     Geinitz. Quite a lot of text was taken from the SANE standard, several  man
     pages, and README files.

				   03 Jan 2020				 sane(7)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=sane&sektion=7&manpath=FreeBSD+Ports+15.1.quarterly>

home | help