sane-st400(5)		  SANE Scanner Access Now Easy		   sane-st400(5)

NAME
     sane-st400 - SANE backend for Siemens ST/Highscan flatbed scanners

DESCRIPTION
     The  sane-st400 library implements a SANE (Scanner Access Now Easy) backend
     that provides access to Siemens ST400 flatbed scanners and compatibles.  At
     present, the following scanners are supported by this backend:

	    Siemens ST400 (6 bit gray scale)
	    Siemens ST800 (6 bit gray scale)

     The driver supports line art and gray scans up to 8bpp.

     The Siemens ST/Highscan series includes several more models, e.g. the ST300
     and ST600.  If you own one of these scanners, or a scanner other  than  the
     ones listed above that works with this backend, please let us know by send-
     ing  the  scanner's  model name, SCSI ID, and firmware revision to sane-de-
     vel@alioth-lists.debian.net.	  Have	       a	 look	      at
     http://www.sane-project.org/mailing-lists.html  concerning  subscription to
     sane-devel.

DEVICE NAMES
     This backend expects device names of the form:

	    special

     Where special is the path-name for the special device that corresponds to a
     SCSI scanner. For SCSI scanners, the special device name must be a  generic
     SCSI device or a symlink to such a device.  Under Linux, such a device name
     could be /dev/sga or /dev/sge, for example.  See sane-scsi(5) for details.

CONFIGURATION
     The  contents  of the st400.conf file is a list of device names that corre-
     spond to Siemens scanners.  Empty lines and lines starting with a hash mark
     (#) are ignored.  A sample configuration file is shown below:

	    /dev/scanner
	    # this is a comment
	    /dev/sge

     The default configuration file that is distributed  with  SANE  looks  like
     this:

	    scsi SIEMENS "ST 400" Scanner * * 3 0

     In  this  configuration, the driver can only access the ST400 model at SCSI
     ID 3 LUN 0 (see section BUGS below for the reason).  To use the driver with
     other scanner models, add an appropriate line to  the  configuration  file.
     For example, to use it with an ST800 at SCSI ID 3 LUN 0, add the line:

	    scsi SIEMENS "ST 800" Scanner * * 3 0

FILES
     /usr/local/etc/sane.d/st400.conf
	    The  backend  configuration  file (see also description of SANE_CON-
	    FIG_DIR below).

     /usr/local/lib/sane/libsane-st400.a
	    The static library implementing this backend.

     /usr/local/lib/sane/libsane-st400.so
	    The shared library implementing this  backend  (present  on  systems
	    that support dynamic loading).

ENVIRONMENT
     SANE_CONFIG_DIR
	    This environment variable specifies the list of directories that may
	    contain  the  configuration  file.	On *NIX systems, the directories
	    are separated by a colon (`:'), under OS/2, they are separated by  a
	    semi-colon	(`;').	 If  this variable is not set, the configuration
	    file is searched in two  default  directories:  first,  the  current
	    working  directory	(".") and then in /usr/local/etc/sane.d.  If the
	    value of the environment variable ends with the directory  separator
	    character,	then  the default directories are searched after the ex-
	    plicitly specified	directories.   For  example,  setting  SANE_CON-
	    FIG_DIR to "/tmp/config:" would result in directories tmp/config, .,
	    and /usr/local/etc/sane.d being searched (in this order).

     SANE_DEBUG_ST400
	    If	the  library was compiled with debug support enabled, this envi-
	    ronment variable controls the debug level for this backend. E.g.,  a
	    value of 128 requests all debug output to be printed. Smaller levels
	    reduce verbosity.

MISSING FUNCTIONALITY
     Everything but the most basic stuff.

BUGS
     Currently,  the  backend  does not check if the attached device really is a
     ST400.  It will happily accept everything that  matches  the  configuration
     entries.	This makes it easy to test the backend with other scanners: Just
     add an appropriate line to the configuration file.  The configuration  file
     as distributed (see above) only works with the ST400.  Be careful: If there
     is no config file at all, the backend defaults to /dev/scanner.

     The  ST400 answers on all eight SCSI LUNs.  Normally this is not a problem,
     as LUN support is usually disabled in SCSI drivers, but if you  are  seeing
     multiple  instances of the scanner in a device list, either disable LUNs in
     your SCSI setup or change the entry in the configuration file to match  LUN
     0 only.

DEBUG
     If you encounter a bug please set the environment variable SANE_DEBUG_ST400
     to  128  and  try to regenerate the problem. Then send me a report with the
     log attached.

     If you encounter a SCSI bus error or trimmed and/or displaced images please
     also set the environment variable SANE_DEBUG_SANEI_SCSI to 128 before send-
     ing me the report.

SEE ALSO
     sane(7), sane-scsi(5)
     http://www.informatik.uni-oldenburg.de/~ingo/sane/