Skip site navigation (1)Skip section navigation (2)

FreeBSD Manual Pages

  
 
  

home | help
scanimage(1)		  SANE Scanner Access Now Easy		    scanimage(1)

NAME
     scanimage - scan an image

SYNOPSIS
     scanimage	[-d  dev] [--format=output-format] [-i profile] [-L] [-f device-
     format]   [-b   [format]]	  [--batch-start=start]    [--batch-count=count]
     [--batch-increment=increment] [--batch-double] [--accept-md5-only] [-p] [-o
     path] [-n] [-T] [-A] [-h] [-v] [-B size] [-V] [device-specific-options]

DESCRIPTION
     scanimage	is a command-line interface to control image acquisition devices
     such as flatbed scanners or cameras.  The device is controlled via command-
     line options.  After command-line processing, scanimage  normally	proceeds
     to  acquire  an image.  The image data is written to standard output in one
     of the PNM (portable aNyMaP) formats (PBM for black-and-white  images,  PGM
     for  grayscale  images,  and PPM for color images), TIFF format (black-and-
     white, grayscale or color), PNG format, or JPEG format  (compression  level
     75).   scanimage accesses image acquisition devices through the SANE (Scan-
     ner Access Now Easy) interface and can thus support any  device  for  which
     there  exists  a SANE backend (try apropos sane- to get a list of available
     backends).

EXAMPLES
     To get a list of devices:

       scanimage -L

     To scan with default settings to the file image.pnm:

       scanimage >image.pnm

     To scan 100x100 mm to the file image.tiff (-x and -y may not  be  available
     with all devices):

       scanimage -x 100 -y 100 --format=tiff >image.tiff

     To print all available options:

       scanimage -h

OPTIONS
     There are two sets of options available when running scanimage.

     The  options that are provided by scanimage itself are listed below. In ad-
     dition, each backend offers its own set of options and these  can	also  be
     specified.  Note  that  the options available from the backend may vary de-
     pending on the scanning device that is selected.

     Often options that are similar in function may be	implemented  differently
     across  backends.	An  example of this difference is --mode Gray and --mode
     Grayscale.  This may be due to differing backend  author  preferences.   At
     other  times,  options are defined by the scanning device itself and there-
     fore out of the control of the backend code.

     Parameters are separated by a blank from single-character options (e.g.  -d
     epson) and by a "=" from multi-character options  (e.g.   --device-name=ep-
     son).

     -d dev, --device-name=dev
	    specifies  the  device  to access and must be followed by a SANE de-
	    vice-name like `epson:/dev/sg0' or `hp:/dev/usbscanner0'.	A  (par-
	    tial)  list of available devices can be obtained with the --list-de-
	    vices option (see below).  If no device-name  is  specified  explic-
	    itly,  scanimage  reads  a device-name from the environment variable
	    SANE_DEFAULT_DEVICE.  If this variable is not  set,  scanimage  will
	    attempt to open the first available device.

     --format=output-format
	    selects  how  image  data  is written to standard output or the file
	    specified by the --output-file option.  output-format  can	be  pnm,
	    tiff, png, or jpeg.  If --format is not specified, PNM is written by
	    default.

     -i profile, --icc-profile=profile
	    is used to include an ICC profile into a TIFF file.

     -L, --list-devices
	    requests  a  (partial) list of devices that are available.	The list
	    may not be complete since some devices may be available, but are not
	    listed in any of the configuration files (which are typically stored
	    in directory /usr/local/etc/sane.d).  This is particularly the  case
	    when  accessing  scanners  through	the network.  If a device is not
	    listed in a configuration file, the only way to access it is by  its
	    full device name.  You may need to consult your system administrator
	    to find out the names of such devices.

     -f format, --formatted-device-list=device-format
	    works  similarly  to  --list-devices,  but requires a format string.
	    scanimage replaces the placeholders %d %v %m %t %i %n with	the  de-
	    vice  name,  vendor  name, model name, scanner type, an index number
	    and newline respectively. The command

	    scanimage -f " scanner number %i device %d is a %t, model  %m,  pro-
	    duced by %v "

	    will produce something like:

		   scanner  number 0  device sharp:/dev/sg1 is	a  flatbed scan-
		   ner, model JX250 SCSI, produced by SHARP

     The --batch* options provide features for scanning documents using document
     feeders.

	    -b [format], --batch=[format]
		   is used to specify the format of the filename that each  page
		   will  be  written  to.   Each page is written out to a single
		   file.  If format is not specified, the default  of  out%d.pnm
		   (or	out%d.tif  for --format tiff, out%d.png for --format png
		   or out%d.jpg for --format jpeg) will be used.  This option is
		   incompatible with the --output-path option.	format is  given
		   as a printf style string with one integer parameter.

	    --batch-start=start
		   selects  the  page number to start naming files with. If this
		   option is not given, the counter will start at 1.

	    --batch-count=count
		   specifies the number of pages to attempt  to  scan.	 If  not
		   given, scanimage will continue scanning until the scanner re-
		   turns  a state other than OK.  Not all scanners with document
		   feeders signal when the ADF is empty. Use this option to work
		   around them.

	    --batch-increment=increment
		   sets the amount that the number in  the  filename  is  incre-
		   mented by.  Generally this is used when you are scanning dou-
		   ble-sided   documents  on  a  single-sided  document  feeder.
		   --batch-double is a specific command provided to aid this.

	    --batch-double
		   will automatically set the increment  to  2.   Equivalent  to
		   --batch-increment=2.

	    --batch-prompt
		   will ask for pressing RETURN before scanning a page. This can
		   be used for scanning multiple pages without an automatic doc-
		   ument feeder.

     --accept-md5-only
	    only  accepts user authorization requests that support MD5 security.
	    The SANE network daemon saned(8) is capable of doing such requests.

     -p, --progress
	    requests that scanimage prints a progress counter. It shows how much
	    image data of the current image has already been received  (in  per-
	    cent).

     -o path, --output-file=path
	    requests that scanimage saves the scanning output to the given path.
	    This  option  is  incompatible  with the --batch option. The program
	    will try to guess --format from the file name. If that is not possi-
	    ble, it will print an error message and exit.

     -n, --dont-scan
	    requests that scanimage only sets the options provided by  the  user
	    but doesn't actually perform a scan. This option can be used to e.g.
	    turn off the scanner's lamp (if supported by the backend).

     -T, --test
	    requests  that  scanimage performs a few simple sanity tests to make
	    sure the backend works as defined by the SANE API. In particular the
	    sane_read() function is exercised by this test.

     -A, --all-options
	    requests that scanimage lists all available options exposed  by  the
	    backend,  including  button  options.  The information is printed on
	    standard output and no scan will be performed.

     -h, --help
	    requests help information.	The information is printed  on	standard
	    output and no scan will be performed.

     -v, --verbose
	    increases  the verbosity of the output of scanimage.  The option may
	    be specified repeatedly, each time increasing the verbosity level.

     -B [size], --buffer-size=size
	    changes input buffer size from the default of 1MB to size KB.

     -V, --version
	    requests that scanimage prints the program	and  package  name,  the
	    version  number  of  the SANE distribution that it came with and the
	    version of the backend that it loads. If more information about  the
	    version  numbers  of  the backends are necessary, the DEBUG variable
	    for the dll layer can be used. Example:  SANE_DEBUG_DLL=3  scanimage
	    -L.

     As  you  might  imagine, much of the power of scanimage comes from the fact
     that it can control any SANE backend.  Thus, the exact set of  command-line
     options depends on the capabilities of the selected device.  To see the op-
     tions  for  a  device named dev, invoke scanimage via a command-line of the
     form:

	    scanimage --help --device-name dev

     The documentation for the device-specific options printed by --help is best
     explained with a few examples:

     -l 0..218mm [0]
	    Top-left x position of scan area.

	    The description above shows that option -l expects an  option  value
	    in	the  range from 0 to 218 mm.  The value in square brackets indi-
	    cates that the current option value is 0 mm. Most  backends  provide
	    similar  geometry  options	for top-left y position (-t), width (-x)
	    and height of scan-area (-y).

     --brightness -100..100% [0]
	    Controls the brightness of the acquired image.

	    The description above shows that option --brightness expects an  op-
	    tion  value  in  the  range  from -100 to 100 percent.  The value in
	    square brackets indicates that the current option value  is  0  per-
	    cent.

     --default-enhancements
	    Set default values for enhancement controls.

	    The  description  above shows that option --default-enhancements has
	    no option value.  It should be thought of as having an immediate ef-
	    fect at the point of the command-line at which it appears.	For  ex-
	    ample, since this option resets the --brightness option, the option-
	    pair  --brightness	50 --default-enhancements would effectively be a
	    no-op.

     --mode Lineart|Gray|Color [Gray]
	    Selects the scan mode (e.g., lineart or color).

	    The description above shows that option --mode accepts  an	argument
	    that  must be one of the strings Lineart, Gray, or Color.  The value
	    in the square bracket indicates that the option is currently set  to
	    Gray.   For convenience, it is legal to abbreviate the string values
	    as long as they remain unique.   Also,  the  case  of  the	spelling
	    doesn't matter.  For example, option setting --mode col is identical
	    to --mode Color.

     --custom-gamma[=(yes|no)] [inactive]
	    Determines whether a builtin or a custom gamma-table should be used.

	    The  description  above shows that option --custom-gamma expects ei-
	    ther no option value, a "yes" string, or a "no" string.   Specifying
	    the  option  with  no  value is equivalent to specifying "yes".  The
	    value in square-brackets indicates that the option is not  currently
	    active.   That  is,  attempting to set the option would result in an
	    error message.  The set of available options  typically  depends  on
	    the  settings of other options.  For example, the --custom-gamma ta-
	    ble might be active only when a grayscale  or  color  scan-mode  has
	    been requested.

	    Note  that	the  --help option is processed only after all other op-
	    tions have been processed.	This makes it possible to see the option
	    settings for a particular mode by specifying the  appropriate  mode-
	    options  along  with  the  --help option.  For example, the command-
	    line:

	    scanimage --help --mode color

	    would print the option settings that are in effect when  the  color-
	    mode is selected.

     --gamma-table 0..255,...
	    Gamma-correction  table.   In color mode this option equally affects
	    the red, green, and blue channels simultaneously (i.e., it is an in-
	    tensity gamma table).

	    The description above shows that option --gamma-table  expects  zero
	    or	more  values  in the range 0 to 255.  For example, a legal value
	    for this option would be "3,4,5,6,7,8,9,10,11,12".	Since it's  cum-
	    bersome  to  specify  long vectors in this form, the same can be ex-
	    pressed by the abbreviated form "[0]3-[9]12".  What  this  means  is
	    that  the  first vector element is set to 3, the 9-th element is set
	    to 12 and the values  in  between  are  interpolated  linearly.   Of
	    course,  it  is  possible  to specify multiple such linear segments.
	    For   example,   "[0]3-[2]3-[6]7,[7]10-[9]6"   is	equivalent    to
	    "3,3,3,4,5,6,7,10,8,6".   The program gamma4scanimage can be used to
	    generate such gamma tables (see gamma4scanimage(1) for details).

     --filename <string> [/tmp/input.ppm]
	    The filename of the image to be loaded.

	    The description above is an example of an option that takes an arbi-
	    trary string value (which happens to be  a	filename).   Again,  the
	    value  in  brackets show that the option is current set to the file-
	    name /tmp/input.ppm.

ENVIRONMENT
     SANE_DEFAULT_DEVICE
	    The default device-name.

FILES
     /usr/local/etc/sane.d
	    This directory holds  various  configuration  files.   For	details,
	    please refer to the manual pages listed below.

     ~/.sane/pass
	    This file contains lines of the form

	    user:password:resource

	    scanimage  uses  this  information	to answer user authorization re-
	    quests  automatically.  The  file  must  have  0600  permissions  or
	    stricter.  You  should  use  this file in conjunction with the --ac-
	    cept-md5-only option to avoid server-side attacks. The resource  may
	    contain any character but is limited to 127 characters.

SEE ALSO
     sane(7),  gamma4scanimage(1), xscanimage(1), xcam(1), xsane(1), scanadf(1),
     sane-dll(5), sane-net(5), sane-"backendname"(5)

AUTHOR
     David Mosberger, Andreas Beck, Gordon Matzigkeit, Caskey Dickson, and  many
     others.  For questions and comments contact the sane-devel mailinglist (see
     http://www.sane-project.org/mailing-lists.html).

BUGS
     For  vector  options, the help output currently has no indication as to how
     many elements a vector-value should have.

				   10 Jul 2008			    scanimage(1)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=scanimage&sektion=1&manpath=FreeBSD+Ports+15.1.quarterly>

home | help