SG_READCAP(8)			    SG3_UTILS			   SG_READCAP(8)

NAME
     sg_readcap - send SCSI READ CAPACITY command

SYNOPSIS
     sg_readcap   [--10]   [--16]   [--brief]	[--help]   [--hex]  [--inhex=FN]
     [--json[=JO]] [--js-file=JFN] [--lba=LBA] [--long] [--pmi] [--raw] [--read-
     only] [--verbose] [--version] [--zbc] DEVICE

     sg_readcap [-16] [-b] [-h] [-H] [-lba=LBA] [-pmi] [-r] [-R] [-v] [-V]  [-z]
     DEVICE

DESCRIPTION
     The  normal action of the SCSI READ CAPACITY command is to fetch the number
     of blocks (and block size) from the DEVICE.

     The SCSI READ CAPACITY command (both 10 and 16 byte  cdbs)  actually  yield
     the  block  address  of  the  last  block and the block size. The number of
     blocks is thus one plus the block address of the last block (as blocks  are
     counted  origin  zero (i.e. starting at block zero)). This is the source of
     many "off by one" errors.

     The READ CAPACITY(16) response provides additional information not found in
     the READ CAPACITY(10) response. This includes protection and logical  block
     provisioning  information,  plus  the number of logical blocks per physical
     block. So even though the media size may not exceed what READ  CAPACITY(10)
     can  show,  it  may  still be useful to examine the response to READ CAPAC-
     ITY(16). Sadly there are horrible SCSI command set implementations  in  the
     wild that crash when the READ CAPACITY(16) command is sent to them.

     Device  capacity  is the product of the number of blocks by the block size.
     This utility outputs this figure in bytes, MiB (1048576 bytes per MiB),  GB
     (1000000000 bytes per GB) and, if large enough, TB (1000 GB).

     If sg_readcap is called without the --long option then the 10 byte cdb ver-
     sion  (i.e.  READ	CAPACITY  (10))  is sent to the DEVICE. If the number of
     blocks in the response is reported as 0xffffffff (i.e. (2**32 -  1)  )  and
     the  --hex option has not been given, then READ CAPACITY (16) is called and
     its response is output.

     This utility supports two command line syntaxes, the preferred one is shown
     first in the synopsis and explained in this section. A later section on the
     old command line syntax outlines the second group of options.

OPTIONS
     Arguments to long options are mandatory for short options as well.  The op-
     tions are arranged in alphabetical order based on the long option name.

     --10   Use the 10 byte cdb variant of the READ CAPACITY  command.	This  is
	    currently  the  default  action  of  this  utility. That default may
	    change to the 16 byte variant, especially if T10 deprecates  the  10
	    byte variant.

     --16   Use  the  16  byte cdb variant of the READ CAPACITY command. See the
	    '--long' option.  -b, --brief outputs two hex numbers (prefixed with
	    '0x' and space separated) to stdout. The first number is the maximum
	    number of blocks on the device (which is one plus  the  lba  of  the
	    last  accessible  block).  The second number is the size in bytes of
	    each block. If the operation fails then "0x0 0x0" is written to std-
	    out.

     -h, --help
	    print out the usage message then exit.

     -H, --hex
	    output the response to the READ CAPACITY command (either the  10  or
	    16	byte  cdb  variant)  in  ASCII	hexadecimal on stdout. Each line
	    starts with a hexadecimal address or index, starting at 0.	If  this
	    option  is	given twice, and ASCII rendering of the 16 bytes on each
	    line is appended to the right hand side of each line.
	    If this option is given three times then 16 bytes of ASCII hexadeci-
	    mal are output in each line with no leading address nor  ASCII  ren-
	    dering  to	the right.  This output is suitable for importing into a
	    later invocation of this utility with the file  containing	the  hex
	    given  to  the  --inhex=FN	option.  When given four (or more times)
	    this option adds a comment line (starting with '#')  describing  the
	    command that caused the output.

     -i, --inhex=FN
	    where FN is a file name whose contents are assumed to be ASCII hexa-
	    decimal.  If  DEVICE is also given then DEVICE is ignored, a warning
	    is issued and the utility continues, decoding the file named FN. See
	    the "HEX, BINARY AND JSON FORMATS" section in the sg3_utils  manpage
	    for  more  information.  If  the --raw option is also given then the
	    contents of FN are treated as binary.

     -j[=JO], --json[=JO]
	    output is in JSON format instead of plain text form. Note that argu-
	    ments to the short and long form  are  themselves  optional  and  if
	    present  start  with  "=" and no whitespace is permitted around that
	    "=".
	    See sg3_utils_json manpage or use '?' for JO to get a summary.

     -J, --js-file=JFN
	    output is in JSON format and it is sent to a file named JFN. If that
	    file exists then it is truncated. By default,  the	JSON  output  is
	    sent to stdout.
	    When  this	option	is  given, the --json[=JO] option is implied and
	    need not be given. The --json[=JO] option may still be needed to set
	    the JO parameter to non-default values.

     -L, --lba=LBA
	    used in conjunction with --pmi option. This variant of READ CAPACITY
	    will yield the last block address after LBA prior to a delay. For  a
	    disk,  given  a LBA it yields the highest numbered block on the same
	    cylinder (i.e. before the heads need to move). LBA is assumed to  be
	    decimal  unless  prefixed by "0x" or it has a trailing "h". Defaults
	    to 0.  This option was made obsolete in SBC-3 revision 26.

     -l, --long
	    Use the 16 byte cdb variant of the READ CAPACITY  command.	The  de-
	    fault action is to use the 10 byte cdb variant which limits the max-
	    imum  block address to (2**32 - 2). When a 10 byte cdb READ CAPACITY
	    command is used on a device whose size is  too  large  then  a  last
	    block address of 0xffffffff is returned (if the device complies with
	    SBC-2 or later).

     -O, --old
	    Switch to older style options. Please use as first option.

     -p, --pmi
	    partial  medium  indicator: for finding the next block address prior
	    to some delay (e.g. head movement). In the absence of  this  option,
	    the total number of blocks and the block size of the device are out-
	    put.  Used in conjunction with the --lba=LBA option. This option was
	    made obsolete in SBC-3 revision 26.

     -r, --raw
	    output response in binary to stdout.

     -R, --readonly
	    open  the  DEVICE  read-only  (e.g. in Unix with the O_RDONLY flag).
	    The default for READ CAPACITY(16) is to open it read-write. The  de-
	    fault  for	READ CAPACITY(10) is to open it read-only so this option
	    does not change anything for this case.

     -v, --verbose
	    increase level of verbosity. Can be used multiple times.

     -V, --version
	    outputs version string then exits.

     -z, --zbc
	    additionally prints out the extra ZBC field (RC_BASIS) in  the  READ
	    CAPACITY response. Using the option implicitly sets the --16 option.

NOTES
     The  response  to READ CAPACITY(16) contains a LBPRZ bit in the SBC-3 stan-
     dard (ANSI INCITS 514-2014). There was also a LBPRZ bit with the same mean-
     ing in the Logical block provisioning VPD page (0xb2). Then  somewhat  con-
     fusingly  T10  expanded the LBPRZ bit to a 3 bit field in SBC-4 draft revi-
     sion 7, but only in the LB provisioning VPD page. The reason for the expan-
     sion was to report a new "provisioning initialization pattern" state  (when
     an unmapped logical block is read). The new state has been assigned LBPRZ=2
     in  the  VPD page and it re-uses LBPRZ=0 in the READ CAPACITY(16) response.
     LBPRZ=1 retains the same meaning for both variants, namely that a block  of
     zeroes will be returned when an unmapped logical block is read.

EXIT STATUS
     The exit status of sg_readcap is 0 when it is successful. Otherwise see the
     sg3_utils(8) man page.

OLDER COMMAND LINE OPTIONS
     The options in this section were the only ones available prior to sg3_utils
     version  1.23  . Since then this utility defaults to the newer command line
     options which can be overridden by using --old (or -O) as the first option.
     See the ENVIRONMENT VARIABLES section for another way to force the  use  of
     these older command line options.

     -16    Use  the  16 byte cdb variant of the READ CAPACITY command.  Equiva-
	    lent to --long in the main description.

     -b     utility outputs two hex numbers (prefixed with '0x' and space  sepa-
	    rated)  to	stdout. The first number is the maximum number of blocks
	    on the device (which is one plus the  lba  of  the	last  accessible
	    block).  The  second number is the size of each block. If the opera-
	    tion fails then "0x0 0x0"  is  written  to	stdout.   Equivalent  to
	    --brief in the main description.

     -h     output  the  usage message then exit. Giving the -? option also out-
	    puts the usage message then exits.

     -H     output the response to the READ CAPACITY command (either the  10  or
	    16 byte cdb variant) in ASCII hexadecimal on stdout.

     -lba=LBA
	    used  in conjunction with -pmi option. This variant of READ CAPACITY
	    will yield the last block  address	after  LBA  prior  to  a  delay.
	    Equivalent to --lba=LBA in the main description.

     -N, --new
	    Switch to the newer style options.

     -pmi   partial  medium  indicator: for finding the next block address prior
	    to some delay (e.g. head movement). In the absence of  this  switch,
	    the total number of blocks and the block size of the device are out-
	    put.  Equivalent to --pmi in the main description.

     -r     output response in binary (to stdout).

     -R     Equivalent to --readonly in the main description.

     -v     verbose:  print out cdb of issued commands prior to execution. '-vv'
	    and '-vvv' are also accepted yielding greater verbosity.

     -V     outputs version string then exits.

     -z     Equivalent to --zbc in the main description.

ENVIRONMENT VARIABLES
     Since sg3_utils version 1.23 the  environment  variable  SG3_UTILS_OLD_OPTS
     can be given. When it is present this utility will expect the older command
     line options. So the presence of this environment variable is equivalent to
     using --old (or -O) as the first command line option.

AUTHORS
     Written by Douglas Gilbert

COPYRIGHT
     Copyright (C) 1999-2023 Douglas Gilbert
     This software is distributed under the GPL version 2. There is NO warranty;
     not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
     sg_inq(sg3_utils)

sg3_utils-1.48			    June 2023			   SG_READCAP(8)