NAME
     sg_write_and_verify - send the SCSI WRITE AND VERIFY command

SYNOPSIS
     sg_write_verify   [--16]	[--bytchk=BC]	[--dpo]   [--group=GN]	[--help]
     [--ilen=ILEN] [--in=IF]  --lba=LBA  [--num=NUM]  [--repeat]  [--timeout=TO]
     [--verbose] [--version] [--wrprotect=WP] DEVICE

DESCRIPTION
     Send a SCSI WRITE AND VERIFY (10) or (16) command to DEVICE. The data to be
     written  is read from the IF file or, in its absence, a buffer full of 0xff
     bytes is used. The length of the data-out buffer sent with the  command  is
     ILEN bytes or, if that is not given, then it is the length of the IF file.

     The  write  operation  is	to the DEVICE's medium (optionally to its cache)
     starting at logical block address LBA for NUM logical  blocks.   After  the
     write  to	medium	is  performed  a  verify operation takes place which may
     viewed as a medium read (with appropriate checks) but without the data  be-
     ing  returned.  Additionally,  if BS is set to one, the data read back from
     the medium in the verify operation is compared  to  the  original	data-out
     buffer.

     The  relationship	between the number of logical blocks to be written (i.e.
     NUM) and the length (in bytes) of the data-out buffer (i.e.  ILEN)  may  be
     simply  found  by multiplying the former by the logical block size. However
     if the DEVICE has protection information (PI) then it becomes  a  bit  more
     complicated.  Hence  the  calculation  is left to the user with the default
     ILEN, in the absence of the IF file, being set to NUM * 512.

     For sending large amounts of data to contiguous logical  blocks,  a  single
     WRITE AND VERIFY command may not be appropriate (e.g. due to operating sys-
     tem limitations). In such cases see the REPEAT section below.

OPTIONS
     Arguments to long options are mandatory for short options as well.  The op-
     tions are arranged in alphabetical order based on the long option name.

     -S, --16
	    Send  a WRITE AND VERIFY(16) command. The default is to send a WRITE
	    AND VERIFY(10) command unless LBA or NUM are too large  for  the  10
	    byte variant.

     -b, --bytchk=BC
	    where BC is the value to place in the command's BYTCHK field. Values
	    between  0 and 3 (inclusive) are accepted. The default is value is 0
	    which implies only a write to the medium then a verify operation are
	    performed. The only other value T10 defines  currently  is	1  which
	    does  performs  an additional comparison between the data-out buffer
	    that was used by the write operation and the contents of the logical
	    blocks read back from the medium.

     -d, --dpo
	    Set the DPO (disable page out) bit in the command. The default is to
	    leave it clear.

     -g, --group=GN
	    where GN is the value to place in the command's GROUP NUMBER  field.
	    Values  between  0	and  63 (inclusive) are accepted. The default is
	    value is 0.

     -h, --help
	    output the usage message then exit.

     -I, --ilen=ILEN
	    where ILEN is the number  of  bytes  that  will  be  placed  in  the
	    data-out  buffer.  If  the	IF  file is given then no more than ILEN
	    bytes are read from that file. If the IF file does not contain  ILEN
	    bytes then an error is reported. If the  IF file is not given then a
	    data-out buffer with ILEN bytes of 0xff is sent.

     -i, --in=IF
	    read  data	(binary)  from file named IF. If IF is "-" then stdin is
	    used. This data will become the data-out buffer and will be  written
	    to the DEVICE's medium. If BC is 1 then that data-out buffer will be
	    held  until after the verify operation and compared to the data read
	    back from the medium.

     -l, --lba=LBA
	    where LBA is the logical block address to start the write to medium.
	    Assumed to be in decimal unless prefixed with '0x' or has a trailing
	    'h'.  Must be provided.

     -n, --num=NUM
	    where NUM is the number of blocks, starting at LBA, to write to  the
	    medium. The default value for NUM is 1.

     -R, --repeat
	    this  option will continue to do WRITE AND VERIFY commands until the
	    IF file is exhausted. This option requires both the --ilen=ILEN  and
	    --in=IF options to be given. Each command starts at the next logical
	    block  address  and is for no more than NUM blocks. The last command
	    may be shorter with the number of  blocks  scaled  as  required.  If
	    there  are residue bytes a warning is sent to stderr. See the REPEAT
	    section.

     -t, --timeout=TO
	    where TO is the command timeout value in seconds. The default  value
	    is 60 seconds. If NUM is large then command may require considerably
	    more time than 60 seconds to complete.

     -v, --verbose
	    increase the degree of verbosity (debug messages).

     -V, --version
	    output version string then exit.

     -w, --wrprotect=WP
	    set  the  WRPROTECT  field	in the cdb to WP. The default value is 0
	    which implies no protection information is sent (along with the user
	    data) in the data-out buffer.

REPEAT
     For data sizes around a megabyte and larger, it may be appropriate to  send
     multiple SCSI WRITE AND VERIFY commands due to operating system limitations
     (e.g.  pass-through SCSI interfaces often limit the amount of data that can
     be passed with a SCSI command). With this utility the mechanism  for  doing
     that is the --repeat option.

     In  this  mode  the --ilen=ILEN and --in=IF options must be given. The ILEN
     and NUM values are treated as a per SCSI command  parameters.  Up	to  ILEN
     bytes  will  be read from the IF file continually until it is exhausted. If
     the IF file is stdin, reading continues until an EOF is detected. The  data
     read  from  each  iteration becomes the data-out buffer for a new WRITE AND
     VERIFY command.

     The last read from the file (or stdin) may read less  than  ILEN  bytes  in
     which  case  the number of logical blocks sent to the last WRITE AND VERIFY
     is scaled back accordingly. If there is a residual number of bytes left af-
     ter that scaling then that is reported to stderr.

     If an error occurs then that is reported to stderr and via the exit  status
     and the utility stops at that point.

NOTES
     Other  SCSI  WRITE  commands have a Force Unit Access (FUA) bit but that is
     set (implicitly) by WRITE AND VERIFY commands hence there is no  option  to
     set  it.  The  data-out  buffer may still additionally be placed in the DE-
     VICE's cache and setting the DPO bit is a hint not to do that.

     Normal SCSI WRITEs can be done with the ddpt and the sg_dd  utilities.  The
     SCSI  WRITE  SAME	command can be done with the sg_write_same utility while
     the SCSI COMPARE AND WRITE command (sg_compare_and_write utility) offers  a
     "test and set" facility.

     Various numeric arguments (e.g. LBA) may include multiplicative suffixes or
     be  given	in  hexadecimal.  See  the  "NUMERIC  ARGUMENTS"  section in the
     sg3_utils(8) man page.

EXIT STATUS
     The exit status of sg_write_verify is 0 when it is successful. If the  ver-
     ify  operation  fails that is typically indicated with a medium error which
     leads to an exit status of 3.

     If BC is set to 1 and the comparison it causes fails this utility will  in-
     dicate the miscompare with an exit status of 14. For other exit status val-
     ues see the EXIT STATUS section in the sg3_utils(8) man page.

EXAMPLES
     To  start	with, a simple example: write 1 block of data held in file t.bin
     that is 512 bytes long then write that block to LBA 0x1234 on /dev/sg4 .

       # sg_write_verify --lba=0x1234 --in=t.bin /dev/sg4

     Since '--num=' is not given then it defaults to 1. Further the  ILEN  value
     is  obtained  from  the  file size of t.bin . To additionally do a data-out
     comparison to the read back data:

       # sg_write_verify -l 0x1234 -i t.bin --bytchk=1 /dev/sg4

     The ddpt command can do copies between SCSI devices using	READ  and  WRITE
     commands.	However, currently it has no facility to promote those WRITES to
     WRITE AND VERIFY commands. Using a pipe, that could be done like this:

       # ddpt if=/dev/sg2 bs=512 bpt=8 count=11 of=- |
     sg_write_verify --in=- -l 0x567 -n 8 --ilen=4096 --repeat /dev/sg4

     Both ddpt and sg_write_verify are configured for segments	of  8  512  byte
     logical  blocks.  Since  11  logical  blocks  are read then first 8 logical
     blocks are copied followed by a copy of the remaining 3 blocks. Since it is
     assumed that there is  no	protection  information  then  the  data-in  and
     data-out buffers will be 4096 bytes each. For sg_write_verify this needs to
     be stated explicitly with the --ilen=4096 option.

AUTHORS
     Bruno Goncalves and Douglas Gilbert.

REPORTING BUGS
     Report bugs to <dgilbert at interlog dot com>.

COPYRIGHT
     Copyright (C) 2014-2018 Douglas Gilbert
     This software is distributed under a BSD-2-Clause license. There is NO war-
     ranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

SEE ALSO
     ddpt(in   a  package  of  that  name),  sg_compare_and_write(8),  sg_dd(8),
     sg_write_same(8)

sg3_utils-1.48			  January 2022		     WRITE AND VERIFY(8)

Want to link to this manual page? Use this URL:
<https://man.freebsd.org/cgi/man.cgi?query=sg_write_verify&sektion=8&manpath=FreeBSD+Ports+15.1.quarterly>