silk.conf(5)			 SiLK Tool Suite		    silk.conf(5)

NAME
     silk.conf - SiLK site configuration file

DESCRIPTION
     The silk.conf SiLK site configuration file is used to associate symbolic
     names with flow collection information stored in SiLK Flow records.

     In addition to the information contained in the NetFlow or IPFIX flow
     record (e.g., source and destination addresses and ports, IP protocol, time
     stamps, data volume), every SiLK Flow record has two additional pieces of
     information that is added when rwflowpack(8) converts the NetFlow or IPFIX
     record to the SiLK format:

     *	 The sensor typically denotes the location where the flow data was col-
	 lected; e.g., an organization that is instrumenting its border routers
	 would create a sensor to represent each router.  Each sensor has a
	 unique name and numeric ID.

     *	 The flowtype represents information about how the flow was routed
	 (e.g., as incoming or outgoing) or other information about the flow
	 (e.g., web or non-web).  The packing process categorizes each flow into
	 a flowtype.  Each flowtype has a unique name and numeric ID.

     Note that the binary form of SiLK flow records represent the sensor and
     flowtype by their numeric IDs, not by their names.

     For historic reasons, one rarely speaks of the flowtype of a SiLK Flow
     record, but instead refers to its class and type.	Every flowtype maps to a
     unique class/type pair.  The classes and types have names only; they do not
     have numeric IDs.	Note that flowtype and type are different concepts de-
     spite the similarity of their names.

     A class is generally used to represent topological features of the network
     with different collections of sensors, since every active sensor must be-
     long by one or more classes.  Every class must have a unique name.

     A type is used to distinguish traffic within a single topological area
     based on some other dimension.  For example, incoming and outgoing traffic
     is generally distinguished into different types.  Web traffic is also fre-
     quently split into a separate type from normal traffic in order to parti-
     tion the data better.  The type names within a class must be unique, but
     multiple classes may have a type with the same name.

     As stated above, each class/type pair maps to a unique flowtype.

     The silk.conf file defines

     *	 the mapping between sensor names and sensor IDs

     *	 optional named collections of sensors called sensor-groups

     *	 the names of the available classes

     *	 the sensors that belong to each class

     *	 the names of the types in each class

     *	 the mapping from a class/type pair to a flowtype ID

     *	 the mapping between a flowtype name and a flowtype ID

     *	 the default class to use for rwfilter(1) and rwfglob(1) queries

     *	 for each class, the default types to use for rwfilter and rwfglob

     *	 the layout of the directory tree for the SiLK archive (flow data repos-
	 itory) relative to the root directory

     *	 a default value for the --packing-logic switch to rwflowpack(8)

     In normal usage, the silk.conf file will be located at the root of the SiLK
     data spool referenced by the SILK_DATA_ROOTDIR environment variable, or
     specified on the command line using the --data-rootdir flag.  This ensures
     that the sensor and class definitions in the site configuration match the
     data in the flow records you retrieve.

     If you cannot place the site configuration file in the data root directory,
     or the file in that location is incorrect, you can use the SILK_CONFIG_FILE
     environment variable to specify the location of your configuration file
     (including the file name).  Many SiLK commands provide the --site-con-
     fig-file switch which allows you to specify the name of the site configura-
     tion file on the command line.

     By having the site configuration information outside of the SiLK tools, a
     single SiLK installation can be used to query different data stores (though
     each invocation of a command may only query one storage location).

     Any additions or modifications to the silk.conf file will be seen by all
     SiLK applications upon their next invocation.  There are some important
     things to keep in mind when modifying the silk.conf file:

     *	 Once data has been collected for a sensor or a flowtype, the sensor or
	 flowtype should never be removed or renumbered.  SiLK Flow files store
	 the sensor ID and flowtype ID as integers; removing or renumbering a
	 sensor or flowtype breaks this mapping.  In order to keep the mapping
	 consistent, old sensor and flowtype definitions should remain indefi-
	 nitely.  Completely unused sensors or flowtypes may be removed, but the
	 IDs of the remaining sensors and flowtypes must not be modified.

     *	 The path to the files in the SiLK data store often involve the sensor
	 name, flowtype name, class name, and/or type name.  If any of those
	 names are changed, it will be necessary to rename all the previously
	 packed data files that have the former name as part of their path.

     *	 If the SiLK installation at your site is distributed across multiple
	 hosts (for example, if packing occurs on a machine separate from analy-
	 sis), it is important to synchronize changes to the silk.conf files.

     *	 The packing logic plug-in file, packlogic-*.so (e.g., pack-
	 logic-twoway(3), packlogic-generic(3)), used by rwflowpack(8) checks
	 for specific class names, type names, and flowtype names at start up,
	 and it will exit with an error if the names it expects do not exist.
	 In addition, it checks that the flowtype IDs it has match with those in
	 the silk.conf file.  When new flowtypes are added, the packlogic-*.so
	 file will need to be updated if rwflowpack is to generate SiLK Flow
	 records with the new flowtype.

     *	 When rwflowpack reads incoming flow records, those records are associ-
	 ated with a sensor name as determined by the sensor.conf(5) file.
	 rwflowpack uses the silk.conf file to map the sensor name to the sensor
	 ID, and it stores the sensor ID in the SiLK records it creates.
	 Changes to the silk.conf and sensor.conf files may need to be coordi-
	 nated.

SYNTAX
     When parsing the site configuration file, blank lines are ignored.  Com-
     ments are also ignored and may begin at any location on a line by specify-
     ing the character "#" outside of a quoted string.	The comment continues to
     the end of the line.

     Each non-empty line begins with a command name followed by one or more ar-
     guments.  Whitespace (one or more space and/or tab characters) may appear
     before the command and is required to separate the command and its argu-
     ments.  Command names are textual atoms, while arguments may either be tex-
     tual atoms or quoted strings.

     *	 A textual atom may contain the alphanumeric characters ("A"-"Z",
	 "a"-"z", 0-9), period ("."), hyphen ("-"), underscore ("_"), at ("@"),
	 and forward slash ("/").  To use any other character as part of an ar-
	 gument, a quoted string must be used.

     *	 Quoted strings begin and end with the double-quote character """ which
	 must appear on a single line.	Quoted strings may contain ASCII charac-
	 ters and support C-style backslash-escapes.  The character "#" inside a
	 quoted string does not begin a comment.

     For the commands supported by silk.conf and described below, unless a com-
     mand explicitly states that it is used by particular applications, it
     should be considered used by all of the SiLK analysis tools and the packing
     tools flowcap(8), rwflowpack(8), and rwflowappend(8).

     There are three contexts for commands: top-level, class block, and group
     block contexts.  The class block and group block contexts are used to de-
     scribe individual features of classes and groups, while top-level commands
     are used to describe the entire configuration and to define sensors.

     The valid commands for each context are described below.

   Top-Level Commands
     class class-name
	 The "class" command begins a new class block.	It takes as an argument
	 the name of the class being defined.  Each class must have a unique
	 name.	A class block is closed with the "end class" command.  See the
	 "Class Block Commands" section below for a list of commands valid in-
	 side class blocks.

	 The class name must begin with a letter, must not be longer than 32
	 characters, and may not contain whitespace characters or these charac-
	 ters: forward slash ("/"), backward slash ("\"), double quote ("""),
	 single quote ("'"), and comma (",").

	 A site that does not use multiple classes should define a single class
	 with a name like "all" or "default".

	 To be valid, a configuration file must contain at least one class defi-
	 nition.

	 Example: class all

     default-class class-name
	 rwfilter(1) and rwfglob(1) will use a default class when the user does
	 not specify an explicit --class or --flowtype.  This command specifies
	 that default class; the class must have been created prior to this com-
	 mand.	If more than one default class is set, the last definition en-
	 countered is used.

	 Example: default-class all

     group group-name
	 The "group" command begins a sensor group blocks and takes as an argu-
	 ment the name of the group to be defined.  Sensor groups are a conve-
	 nient way of defining named collections of sensors for inclusion in
	 classes.  As of SiLK 3.21.0, sensor group names are accepted by the
	 --sensors option of rwfilter, rwfglob, and rwsiteinfo(1).  A group
	 block is closed using the "end group" command.  See the "Group Block
	 Commands" section below for details on valid commands within group
	 blocks.

	 Example: group test-sensors

     include "file-name"
	 The "include" command is used to include the contents of another file.
	 This may be used to separate large configurations into logical units.
	 An analyst may wish to create their own site configure file to augment
	 the default one with additional sensor groups or to change the de-
	 fault-class.  (Note that all sensors, classes, groups, and types must
	 be declared before they may be referenced.)

	 Example: include "silk-2.conf"

     packing-logic "file-name"
	 The "packing-logic" command provides a default value for the --pack-
	 ing-logic switch on rwflowpack(8).  The value is the path to a plug-in
	 that rwflowpack loads; the plug-in provides functions that determine
	 into which class and type a flow record will be categorized.  The path
	 specified here will be ignored when the --packing-logic switch is ex-
	 plicitly specified to rwflowpack or when SiLK has been configured with
	 hard-coded packing logic.

	 Example: packing-logic "packlogic-twoway.so"

     path-format "format-string"
	 File and directory locations relative to the SILK_DATA_ROOTDIR may be
	 defined using the "path-format" command.  The "path-format" is used by
	 rwflowpack and rwflowappend(8) when writing data to the data reposi-
	 tory, and it is used by rwfilter and rwfglob when reading or listing
	 files in the data repository.	This command takes a format string spec-
	 ification that supports the following "%"-conversions:

	 %C  The textual class name

	 %d  The day of the month as a two-digit, zero-padded number

	 %F  The textual flowtype name for this class/type pair (see also %f)

	 %f  The flowtype ID, as an unpadded number (see also %F)

	 %H  The hour (24-hour clock) as a two-digit, zero-padded number

	 %m  The month of the year as a two-digit, zero-padded number

	 %N  The textual sensor name (see also %n)

	 %n  The sensor ID, as an unpadded number (see also %N)

	 %T  The textual type name

	 %x  The default file name, which is equivalent to "%F-%N_%Y%m%d.%H"

	 %Y  The year as a four-digit, zero-padded number

	 %%  A literal "%" character

	 A "%" followed by any other character is an error.

	 For example, to place all spooled files directly in the data root di-
	 rectory, the path format %x could be used.  To use two levels of hier-
	 archy, the first containing the year and month, and the second contain-
	 ing the day and sensor name, like "2006-01/23-alpha/...", the format
	 would be "%Y-%m/%d-%N/%x".

	 If no path format is set by the configuration file, the default path
	 format of "%T/%Y/%m/%d/%x" is used.

	 All path formats are currently required to end in "/%x" so that infor-
	 mation may be extracted from the file name.  This requirement may be
	 lifted in the future.

	 Example: %C/%T/%Y/%m/%d/%x

     sensor sensor-id sensor-name
     sensor sensor-id sensor-name "sensor-description"
	 Individual sensor definitions are created with the "sensor" command.
	 This command creates a new sensor with the given name and numeric ID.
	 Sensor names must begin with a letter, must not be longer than 64 char-
	 acters, and may not contain whitespace characters or these characters:
	 forward slash ("/"), backward slash ("\"), double quote ("""), single
	 quote ("'"), comma (","), and underscore ("_").

	 The sensor line may may also provide an optional description of the
	 sensor, enclosed in double quotes.  The description can be used however
	 your installation chooses to use it.  The description may be viewed by
	 specifying the "describe-sensor" field to rwsiteinfo(1).  (When using
	 sensor descriptions, the file's "version" must be 2.)

	 It is an error to define two different sensors with the same sensor ID
	 or the same sensor name.

	 A sensor may be associated with multiple classes.

	 NOTE: It is extremely important not to change the sensor-id or sen-
	 sor-name for a given sensor once that sensor is in use.  The sensor-id
	 field is stored numerically in SiLK data files, and the sensor-name
	 field is used to construct file names within the data root directory.

	 Example: sensor 0 S001

	 Example: sensor 0 S001  "Primary connection to ISP"

     version version-number
	 The "version" command declares that this configuration file conforms to
	 a given version of the configuration file format.  If the tools do not
	 support this version of the configuration file, they will report an er-
	 ror.  Currently, versions 1 and 2 of the format is defined, where ver-
	 sion 2 indicates that sensor descriptions are present.

	 It is a recommended practice to include the version number at the be-
	 ginning of all configuration files for compatibility with future ver-
	 sions.

	 Example: version 1

   Class Block Commands
     As stated above, a class block begins with the command "class" followed by
     the name of the class.  Each class must have a unique name not longer than
     32 characters.

     The commands inside a class block define the sensors associated with it,
     the class's types, the mapping from the class/type pair to the flowtype
     name and flowtype ID, and the default types for the class.

     end class
	 The "end class" command ends the definition of a class.  Following an
	 "end class" command, top-level commands are again accepted.

	 Example: end class

     default-types type-name ...
	 When no types are specified for the "rwfilter" or "rwfglob" commands,
	 the default set of types for the selected class is used.  Each of the
	 types listed in this command is included as a default type of the
	 class.

	 Example: default-types in inweb

     sensors sensor-name-or-group-ref ...
	 The "sensors" command is used to associate sensors with a class.  In
	 short, to declare that these sensors have data for this class.  Each
	 item in the list must be either the name of a sensor or the name of a
	 sensor group preceded by an at ("@") character.  (If the group name is
	 a quoted string, include the "@" within the quote characters.)  When
	 you add a sensor group, it is equivalent to adding each individual sen-
	 sor in that group to the class; nothing records that the group has been
	 added to the class.  Since no record is kept, adding sensors to the
	 group after the class block does not add those sensors to this class.

	 Example: sensors my-sensor-1 my-sensor-2 @my-group-1

     type flowtype-id type-name [ flowtype-name ]
	 The "type" command defines a type name within the current class and it
	 specifies the flowtype ID to use for that class/type pair.  In addi-
	 tion, the "type" command may specify a flowtype name.	The flowtype ID
	 and flowtype name must be unique across the entire silk.conf file (and
	 any included files).  If a flowtype name is not specified, a default
	 flowtype name is constructed by concatenating the name of the class and
	 the name of the type.	(e.g. the type "in" in the class "all" would
	 have a flowtype name of "allin".)  Within a class, each type must have
	 a unique name, but multiple classes may use the same type name.  The
	 type name and flowtype name must begin with a letter, must not be
	 longer than 32 characters, and may not contain whitespace characters or
	 these characters: forward slash ("/"), backward slash ("\"), double
	 quote ("""), single quote ("'"), and comma (",").

	 As with sensors, it is important to be careful when renumbering flow-
	 type IDs or renaming types or flowtypes because the numeric IDs are
	 stored in data files, and the textual names are used as portions of
	 file and path names.

	 Example: type 0 in

	 Example: type 1 out out

   Group Block Commands
     A group block is a convenience used to define a collection of sensors.
     These collections may be used when adding the same group of sensors to mul-
     tiple classes.  As of SiLK 3.21.0, sensor groups may also be used as argu-
     ments to the --sensors option of rwfilter(1), rwfglob(1), and rwsite-
     info(1).

     A sensor group block begins with the command "group" followed by the name
     of the group.  If multiple groups blocks use the same name, the resulting
     group is the union of the sensors specified in all blocks.  Note that uses
     of "@GROUP-NAME" expand only to the sensors that have been specified in any
     "group GROUP-NAME" blocks seen before that use.

     A group may have the same name as a sensor and the silk.conf file can dis-
     tinguish between them.  However, the name only refers to the sensor when it
     is used in the --sensors switch of rwfilter, rwfglob, and rwsiteinfo.

     end group
	 Close a group block by using the "end group" command.	Following this
	 command, top-level commands are again accepted.

	 Example: end group

     sensors sensor-name-or-group-ref ...
	 Sensors are associated with a sensor group by means of the "sensors"
	 command within a group block.	Each item in the list must be either the
	 name of a sensor or the name of a sensor group preceded by an at ("@")
	 character.  (If the group name is a quoted string, include the "@"
	 within the quote characters.)	When you add a sensor group named A to
	 group B, it is equivalent to adding each individual sensor in A to
	 group B; nothing records that A has been added to B.  Since no record
	 of is kept, adding sensors to A after this group block does not add
	 those sensors to B.  (Though another group B block could be opened to
	 re-add A which would update B with those sensors.)

	 Example: sensors my-sensor-1 my-sensor-2 @my-group-1

SEE ALSO
     rwfilter(1), rwfglob(1), rwsiteinfo(1), sensor.conf(5), flowcap(8), rwflow-
     pack(8), packlogic-twoway(3), packlogic-generic(3), rwflowappend(8),
     silk(7), SiLK Installation Handbook

SiLK 3.22.2			   2026-08-27			    silk.conf(5)