X10CONFIG(5)		       File Formats Manual		    X10CONFIG(5)

NAME
     x10config - Configuration file format for HEYU, an X-10 CM11A serial inter-
     face control program

DESCRIPTION
     Heyu is a program for controlling an X-10 "CM11A" home control device.  See
     the heyu(1) man page for usage information.

     The configuration file contains several critical pieces of information that
     the heyu program needs in order to function, plus a number of user options.
     These are all specified by keywords known as directives which are explained
     below.  In general, directives may appear in any order in the configuration
     file,  however  see  the  exception  to this rule under the heading for the
     ALIAS directive.

     The configuration file, named x10config, is normally stored in the (hidden)
     subdirectory .heyu under your home directory, i.e., $HOME/.heyu/x10config

     For system-wide use, the configuration file may alternatively be stored  as
     file  x10.conf  in the directory /etc/heyu (or as otherwise defined in Con-
     figure for your operating system).

     The configuration file may be located in an additional  subdirectory  level
     under  either  of the directories above.  The additional subdirectory level
     can have a name of your choice, for example "mysub".  In this case you must
     specify the name of the subdirectory with the HEYUSUB environment	variable
     in order for Heyu to find it, for example HEYUSUB=mysub. Somewhat more con-
     venient however is to locate the configuration file in a subdirectory named
     simply  /0  ... /9, e.g. $HOME/.heyu/3/x10config, in which case Heyu can be
     instucted to use the appropriate directory with  the  command  line  option
     '-0' ... '-9'.

     Finally,  the configuration file may be stored in any arbitrary location on
     your hard drive with any arbitrary filename, but  the  full  pathname  will
     have  to be specified either with the '-c' Heyu command line option or with
     the X10CONFIG environment variable.

     If the HEYUSUB environment variable is NOT set or the  '-0'  ...  '-9'  not
     specified,  then  the search will start with $HOME/.heyu/x10config and con-
     tinue with /etc/heyu/x10.conf, stopping with the first one  it  finds.   If
     not found, Heyu will exit with an error message.

     If  the  HEYUSUB environment variable IS set or the '-0' ... '-9' is speci-
     fied,  the  search   for	the   configuration   file   will   start   with
     $HOME/.heyu/<subdirectory>/x10config,  then,  if  not  found, will continue
     looking for /etc/heyu/<subdirectory>/x10.conf. Examples:
	$HOME/.heyu/mysub/x10config
	/etc/heyu/mysub/x10.conf
	/etc/heyu/4/x10.conf

     If not found under either of these places, Heyu will  exit  with  an  error
     message.

     (The  main  reason  for  implementing the subdirectory feature is to enable
     Heyu to be used for more than one CM11A interface, with separate configura-
     tion and other files for each.  If you have only one CM11A  interface,  you
     probably won't find a need to bother with it.)

     The  directory  in which the configuration file is located MUST be writable
     by Heyu.

     Case sensistivity:
     The following entities ARE  case-sensitive:  Filenames;  Pathspecs;  Serial
     ports (and the keyword "dummy" used when there is no CM11A connected);
      Heyu  and  shell commands; Alias, Scene, Usersyn, Script, and Launcher la-
     bels.

     The following entities are NOT case sensitive:   Names  of  directives  and
     values of directives other than those listed above; Housecode letters.

TTY directive
     The  TTY directive is the most important.	Syntax is simply the word TTY, a
     space and then the full path name for the serial port to which the CM11A is
     attached.	/dev/ttyS0 would be the first serial port (corresponding to COM1
     under MS-DOS).  /dev/cua0 will also work.
     Examples:

	TTY /dev/ttyS0
	TTY /dev/cua2
	TTY /dev/usb/ttyUSB0  (implies a USB-Serial adapter)

     To configure Heyu for a CM10A interface (instead of a CM11A or  CM12),  ap-
     pend the keyword "CM10A", e.g.:

	TTY /dev/ttyS0	CM10A

     Note:  If	you've	started  Heyu before configuring for the CM10A, you must
     stop and start it up again.  I.e., 'heyu stop', then 'heyu start'.

TTY dummy directive
     Setting the directive
	TTY dummy
     tells Heyu there is no CM11 powerline interface connected and Heyu commands
     which attempt to communicate with the interface will result in a quick  er-
     ror  message.   However  commands	which  involve	only the heyu_engine and
     heyu_aux daemons will continue to function, e.g., setting and reading flags
     or countdown timers, and executing scripts launched by RF signals forwarded
     from heyu_aux. (Like the name of the serial  port	it  replaces,  the  word
     "dummy" is case sensitive.)

HOUSECODE directive
     The  housecode  directive indicates the housecode for which the CM11A is to
     store in its internal registers the on/off/dim status of  individual  units
     when signals are sent or received over the AC power line.	The 'heyu reset'
     command  (with  no  housecode parameter supplied) will program the CM11A to
     use the housecode provided by this directive.  (It will not do  this  auto-
     matically.)

     Example:
	HOUSECODE   D

     The default for this directive is housecode A.

ALIAS directive
     An  alias associates a label (front_porch) with an X10 device (A10) so that
     we don't have to remember that the front porch light is house code  A,  de-
     vice 10.  In other words, we can use a mnemonic to represent a device.

     There  are a few other directives in which the user may choose to reference
     an alias label in place of a housecode|unitcode address.	In  these  cases
     the  alias directive must appear before the other directive in the configu-
     ration file in order to be resolved.  Therefore it's a good idea  to  group
     all the alias directives at or near the beginning of the file.

     Alias  labels can refer to one or more X10 devices with the same housecode,
     however Heyu's monitor will display the alias label only if the alias  ref-
     erences a single device address.

     The format for an alias is:
	ALIAS  Label  Housecode|Devices  [Module_type [Module option]]
     where the Housecode letter and Device string are concatenated.

     Label  can  be  any contiguous string (maximum length 32 characters) of al-
     phanumeric characters or period '.', hyphen '-', or underscore '_',  except
     that  the	the  hyphen and underscore may not be the first character in the
     string.  The label may not be the word 'macro'.

     Alias labels are case sensitive, so that 'kitchen' and 'Kitchen'  represent
     two distinct aliases.
     Housecode is a case-insensitive letter A-P (or a-p).
     Devices can be 4 things:

	    1. A single number (example 1)
	    2. A group of numbers separated by commas (example 1,2,14,15)
	    3. A range separated by a dash (example 1-8)
	    4. A combination of 2 and 3 (example 1-8,14,15)

     Module_type is optional and defines for Heyu the attributes of the particu-
     lar kind of module assigned to the Housecode|Unit.
     Heyu  uses this information to determine what state the module should be in
     when the module receives any particular command. E.g., it will know that an
     appliance module will never be in a dimmed state even though it may be sent
     a dim command.

     Unlike many popular software programs which attempt to do your thinking for
     you, Heyu does not decide what X10 command to send based on the Module_type
     defined for the specific housecode|unit address or  alias.   It  does  only
     what  you	tell it to do, and defining a Module_type does not restrict Heyu
     from sending a command which the module may not support.  E.g., if you tell
     Heyu to send a dim command to an appliance module, it will  do  so  without
     question.	But the physical module will not respond and the Heyu state will
     reflect that fact.

     The  following  generic module types and/or specific model numbers are cur-
     rently recognized.  The names are not case-sensitive:

	       *** WARNING - WARNING - WARNING ***

     The X-10 LM465 Lamp Module and WS467 Wall Switch Module were redesigned  in
     2007  but	the model numbers, appearance, and packaging remained unchanged.
     The new designs, designated here as module types LM465-1 and WS467-1,  have
     quite  different  features  and  characteristics from the original designs.
     Among other differences, they support a subset of Extended  Code  commands.
     They  can be distinguished by executing 'heyu xon Hu' and 'heyu xoff Hu' at
     the command prompt.  The redesigned modules will respond and  turn  respec-
     tively On and Off; the original modules won't respond.

     Among  the  potential problems, there's an apparent design error in the re-
     designed WS467 Wall Switch firmware making it not backwards compatible with
     the original design.  A standard X10 bright or dim  or  dimb  signal  won't
     turn it On from the Off state unless preceded by an on signal.

	LM465-1 (LM-1) - Redesigned LM465 lamp module.
	LM    (StdLM LM465 PLM01 PLM03) - Original standard X-10 lamp module.
	LM12  () - Marmitek standard X-10 lamp module.
	LMS   (?) - X-10 2-way lamp module (responds status on/off).
	AM    (StdAM AM486 AM466 PAM01 PAM02) - Standard X-10 appliance module.
	AM12  () - Marmitek standard X-10 appliance module.
	SR227 (PA011) - X-10 socket module.
	AMS   (RR501 PAT01) - X-10 2-way switch (responds status on/off).
	Some  2-way  modules  can be configured to automatically return a Statu-
     sOn/Off
	whenever they are turned On/Off.  For these, the module type parameter
	"DEFER" instructs Heyu not to update the stored  states  of  the  module
     with
	the On/Off signal but let the ensuing StatusOn/Off signal do it. (Other-
     wise
	the changed state following the StatusOn/Off would always be unchanged.)
	RAIN8II () WGL model Rain8II 2-way irrigation controller which
	can be configured to automatically respond with a StatusOn/Off signal
	when turned On/Off.
	WS467-1 (WS-1) - Redesigned WS467 wall switch module.
	WS    (StdWS WS467) - Standard X-10 wall switch module.
	LW10U  () - Marmitek dimming wall switch module.
	WS12A  (XPD3) - X-10 dimming wall switch module.
	WS13A  (XPS3) - X-10 non-dimming wall switch module.
	LM15A (PSM04) - X-10 Socket Rocket screw-in non-dimming lamp module.
	LM15  () - Marmitek screw-in non-dimming lamp module.
	AM14A  (AM15A  PAM21  PAM22)  -  X-10  2-way  appliance module (Extended
     codes).
	LM14A (PLM21) - X-10 2-way lamp module (Extended codes).
	SL1AM (?) - SwitchLinc 1-way switch (Preset codes).
	SL2AM (?) - SwitchLinc 2-way switch (Preset codes).
	SL1LM (?) - SwitchLinc 1-way dimmer (Preset codes).
	SL2LM (SL2380W) - SwitchLinc 2-way dimmer (Preset codes).
	LL1LM (?) - LampLinc 1-way dimmer (Preset codes)
	LL2LM (LL2000STW) - LampLinc 2-way dimmer (Preset codes)
	RS114 () ACT user-programmable 2-way switch module.
	With this module, support for AllUnitsOff, AllLightsOn, and
	AllLightsOff signals is user programmable.  Module type parameters
	AUF, ALO, and ALF match Heyu's support with the module's programming.
	RF234 () ACT user-programmable 2-way switch module.  This 230V
	module has similar to but not identical characteristics with the RS114.
	Based on data from a single device, it appears the RS234 does not
	maintain its address after being turned On or Off.
	AMEXC16 (?) - Module of the appliance type with
	exclusive addressing: An on command turns On only the last
	unit addressed.  All other modules of this type on the
	same housecode turn themselves Off and become unaddressed.
	AMEXC8 (RAIN8) - Modules of the appliance type with
	exclusive addressing within groups of 8 units, i.e., 1-8,
	9-16. Other modules on the same housecode and within the same
	group of units turn themselves Off when the last addressed
	unit in that group is turned On.  A typical device of this
	type is the WGL Rain8 Irrigation Controller.
	AMEXC4 (XM10A XM13A) - Similar to AMEXC8 but with
	exclusive addressing within groups of 4, i.e., 1-4,
	5-8, 9-12, 13-16.  Typical modules of this type are X-10's
	XM10A and XM13A camera power supplies.
	PR511 () - X-10 PR511 2-way Motion Sensing floodlight
	NONE  - No module; supports no X10 commands.
	REMOTE2 - Not actually a module, it can be used as
	a 'target' for X10 commands sent by a transmitter
	with only On/Off codes (like a keychain remote
	or motion sensor), when there is no physical module
	assigned to that Housecode|Unit.
	REMOTE4 - Like the above, but for a four function
	transmitter like a PalmPad which can send Dim and
	Bright codes in addition to On and Off.
	REMOTE6 - Like the above, but for a six function
	transmitter like the Mini- or Maxi-Controller which
	can send On, Off, Dim, Bright, LightsOn, and AllOff
	codes.

	Note that the above two REMOTEs function a little
	differently than lamp modules.	The state for an On
	(or a LightsOn for REMOTE6) code will always be
	recorded as fully On regardless of prior state,
	and the state for Dim/Bright codes can range from
	fully Off through fully On and vice-versa.  This
	allows their use in scripts for controlling things
	other than modules.

	REMOTE3 - Similar to REMOTE4 except that the On
	command is ignored by the state engine except for
	addressing the particular unit in the housecode -
	it does not change the stored brightness level.
	The Off command does set the brightness level to
	zero and the Bright and Dim commands make incremental
	changes in this level within the range fully Off
	to fully On.  (The Bright and Dim signals sent by
	RF remotes do not include a unit code.	This module
	type allows using the On signal to address a
	particular unit without changing the stored brightness
	level and then using the Dim and Bright commands for
	some analog control purpose via a script.)

	REMOTEP - Again not actually a module, but can be
	used as a target for transmitters which send only
	the Preset (1-32) codes.

	SHUTTER (SW10) - Shutter and shade controller
	which support Extended Code Type 0 commands. The
	Marmitek SW10 Shutter Motor Controller is the only
	module known to support these commands and Marmitek
	keeps it a secret.  This Heyu model supports Extended
	Type 0 functions 0x01, 0x02, 0x03, 0x04, and 0x0B.
	The Heyu model also supports the standard On and Off
	commands, but not Dim or Bright, to which the shutter
	module is reported to react in an unpredictable manner.

	VDATA - A virtual module which can store a data
	byte as if it were a (raw) brightness level 0-255.
	Data is written to this virtual module only with the
	 'heyu vdata HU <data>' command - it is unaffected
	by any other X10 command.

     The following security transmitter models are included for use with RF aux-
     iliary input from a W800RF32A or RFXCOM receiver.

	DS10A - (PDS01) X-10 DS10A Security Door/Window Sensor
	DS90  - (DS18-1) X-10 DS90 Sec Door/Window Sensor (2 chan)
	DS18-1	- () ElekHomica DS18 Sec Door/Window Sensor (2 chan)
	DS18   - () ElekHomica DS18 Sec Door/Window Sensor (1 chan)
	MS10A - (PMS01) X-10 MS10A Security Motion Sensor  (See  section  "MS10A
     WARNING" in man page x10aux(5))
	SH624 - (PSR01) X-10 Security Remote
	KR10A - (PKR02, KR21) X-10 Security Keyfob Remote.
	KR18  - (KR18E) Marmitek Security Keyfob Remote.
	SD10  - () Marmitek SD10 Smoke Detectors
	SD90  - () Marmitek SD90 Smoke Detectors
	BMB-SD18 - () BMB SD18 Smoke Detector
	MS90  - (MS18E) Marmitek MS90 Security Motion Sensor
	EH-CWSD10 - () ElekHomica EH-CWSD10 Smoke Detector
	EH-WD210 - () ElecHomica EH-WD210 Water Detector
	GB10  - () Marmitek GB10 Glass Break Detector
	SVDATA - () Generic X10 Security Remote (all 'vdata')

     Most  (but not all) security sensors transmit a 16-bit security ID which is
     detectable with the RFXCOM RF receiver operating in variable length  packet
     mode  (the default).  For backward compatibility, the directive 'SECURID_16
     NO' instructs Heyu to ignore the upper 8-bits.

     Some security sensors, notably the Aux channel of the DS90 Door/Window sen-
     sor, have a firmware bug whereby a parity bit used to  check  the	upper  8
     bits  of  the 16-bit security ID is incorrect in every other RF repetition,
     which means that half the signals are discarded as noise.	 The  configura-
     tion  directive 'SECURID_PARITY  NO' instructs Heyu to disregard the parity
     bit.  It's use is less risky than throwing away half the  signals,  but  if
     none  of your sensors exhibit this bug there's no need to use it.	Configu-
     ration directive 'DISPLAY_RAW_RF  NOISE' can be used to  determine  whether
     the bug exists.

     Unlike  the larger SH624 security remote, the smaller KR10A, KR18, and KR21
     security keyfob remotes have no physical Away/Home or Max/Min switches, and
     by default transmit the swAway and swMin  flags  when  the  Arm  button  is
     pressed.	Appending the parameters SWHOME and/or SWMAX to the alias direc-
     tive for these keyfob remotes results in the flags  being	decoded  respec-
     tively as swHome and/or swMax.

     Alternatively,  appending	the parameter DUMMY to the above security keyfob
     remote alias directive results in the signals transmitted by  the	Arm  and
     Disarm button presses being decoded instead as Alert and Clear, thus allow-
     ing  the  remote to be used for a user-defined purpose unrelated to Arm and
     Disarm.

     Module type SEC_IGNORE can be used to ignore signals from X10 Security sen-
     sors which may not be under your  control,  e.g.,	signals  from  a  nearby
     neighbor's  sensor.   An  unused Housecode/Unit address must be sacrificed.
     Specify the Security IDs for one or more sensors to be ignored.
     Example:
       ALIAS Neighbor_Sensors  P6  SEC_IGNORE  3C  4E  2A

     The following entertainment transmitter model is included for use	with  RF
     Auxiliary input from a W800RF32A, RFXCOM, or MR26A receiver.

	UR81A - (UR61A) X-10 Entertainment Universal Remote.

     The following module types are used to override the settings defined by the
     TRANSCEIVE and RFFORWARD directives for specific units and functions within
     a housecode.  Each requires one of the parameters TRANSCEIVE, RFFORWARD, or
     RFIGNORE be specified following the module name in the ALIAS directive.

	PALMPAD - Controls RF On, Off, Dim, Bright.
	KEYCHAIN - Controls RF On and Off
	ONLYON	- Controls RF On
	ONLYOFF - Controls RF Off
	MS12, MS13, MS14, MS16 - Controls RF On and Off

     (The  MSxx module types are similar to the KEYCHAIN module type but are de-
     fined as "sensors" and as such will be listed in  the  table  displayed  by
     'heyu show sensors'.)

     Example: If housecode C is set to be transceived, specifying:
       ALIAS XMMS_Control C1-6	KEYCHAIN  RFFORWARD
     allows  using the On/Off buttons C1-6 on a RF remote to launch scripts con-
     trolling the XMMS audio player software on the PC without the  delay  of  a
     powerline	signal.  The other unit buttons continue to transceive powerline
     signals to lamps and appliances.

	PLCSENSOR - A target for a transmitter which sends
	X10 On and Off signals over the power line and which has
	a "heartbeat", i.e., it periodically retransmits its current
	state.	The Heyu config directives HIDE_UNCHANGED and
	INACTIVE_TIMEOUT apply to this module type as they do for
	RF security sensors.

     The following module type decodes RF  signals  transmitted  from  RFXSensor
     modules and received by a W800RF32A/AE or RFXCOM RF receiver, and maps them
     to a Housecode|Unit address.

	RFXSENSOR - A decoder for RFXSensor transmitters
	and external sensors.  Two parameters are required, the
	base_address of the sensor and a mnemonic for the type
	of sensor, e.g., Temperature/Humidity, Temp/Barometric
	Pressure, etc. The mnemonic will be one of: TH, TB, TV,
	TP, TT, or T.
     Example:
	ALIAS Basement L9 RFXSENSOR 0x20 TH
     The RF signals sent by the sensor with base_address 0x20 will be decoded as
     RFX  Temperature and Relative Humidity functions received (RCVA) at Housec-
     ode|Unit L9.
     See man page x10rfxsensors(5) for full details.

     The following module types decode RF signals transmitted by  RFXMeter  sen-
     sors.  Each requires as a parameter the ID address of the sensor.
	RFXPOWER - Electric Watt-Hour meter.
	RFXWATER - Water meter.
	RFXGAS	 - Gas meter.
	RFXPULSE - Pulse meter.
	RFXCOUNT - General counter.
     Example:
	ALIAS MyWaterMeter C9 RFXWATER	0x04

     Module type DIGIMAX decodes RF signals transmitted by the DigiMax 210 wire-
     less  thermostat  and  received by the 433.92 MHz RFXCOM X10 RF receiver in
     variable length packet mode. Its parameter is the 16-bit ID of the  thermo-
     stat.

     Module  types  ORE_xxx  decode signals transmitted by various Oregon remote
     sensors and received by the 433.92 MHz RFXCOM X10 RF receiver  in	variable
     length packet mode.  See man page x10oregon(5) for full descriptions.

     Module  type ELS_ELEC1 decodes signals transmitted by the Electrisave CM113
     Electricity Monitor sensor and received by the 433.92 MHz RFXCOM X10 RF re-
     ceiver in variable length packet mode. The optional directive  "ELS_VOLTAGE
     <voltage>"  specifies a nominal AC voltage to be multiplied by the measured
     current to display an apparent power.  See page X10oregon(5) for  more  in-
     formation.

     Module  type  OWL_ELEC2  decodes signals transmitted by the OWL CM119 Elec-
     tricity Monitor sensor and received by the 433.92 MHz  RFXCOM  X10  RF  re-
     ceiver  in  variable  length packet mode. The directive "OWL_VOLTAGE <volt-
     age>" specifies the nominal AC voltage to be used to compute the Power  and
     Energy values.  See page X10oregon(5) for more information.

     SwitchLinc  and  LampLinc modules can be manually configured to always turn
     on to some level less than the maximum (32), or always resume the	previous
     setting.	If  you've  configured your modules in either of these ways, you
     must inform Heyu of the fact by adding the module option  'ONLEVEL  nn'  or
     'ONLEVEL RESUME'.

     NOTE:  In	order  for  the Heyu state engine to properly track the state of
     modules with the 'resume' feature (LM14A and  SwitchLinc/LampLinc	option),
     its memory must be synchronized with the module's memory.	This can be done
     by  sending  the  module an X10 command setting it at a known level greater
     than the 'Off' level, or by having it respond to a status	request  with  a
     preset/xstatus level greater than the 'Off' level.

     Examples:
	ALIAS  hall_light  B7
	ALIAS  patio_lights  B2,4-6
	ALIAS  porch_light  D1	WS467
	ALIAS  livingroom_lamp H7 SL2LM  ONLEVEL 20

     It  is  advisable	to define single-unit aliases for all housecode|units in
     addition to any multiple-unit aliases which may be convenient  for  use  in
     Scenes/Usersyns/Macros,  and  to  define a Module_type only for single-unit
     aliases.
     (Once a Module_type is defined, it applies to that same housecode|unit how-
     ever used, e.g., in the above example Heyu will understand  that  D1  is  a
     WS467 dimmer when either 'heyu turn porch_light on' or 'heyu turn D1 on' is
     executed, or if D1 is also included in a multiple-unit alias like D1,2-5,7)

     Modules not defined for a Housecode|unit in an ALIAS directive are assigned
     to  be  the default module, which is a standard X-10 lamp module.	This can
     be changed with the DEFAULT_MODULE directive.

     Note: Versions of Heyu prior to 2 used a different format for  aliases:  No
     ALIAS  directive was used and the Housecode letter and Units were separated
     by whitespace, e.g., simply 'hall_light  B  7'.   For  compatibility,  Heyu
     version 2 will still accept this format, however its use is discouraged and
     deprecated.  (Module type cannot be specified with this format.)

DEFAULT_MODULE directive
     Sets  the module attributes of all Housecode|Units which are not defined in
     an alias directive.  If not otherwise specified by this directive, the  de-
     fault module is the standard X-10 plug-in lamp module (StdLM).

START_ENGINE directive
     Many of Heyu's features require the Heyu state engine daemon heyu_engine to
     be  running.   This  directive  instructs	Heyu  how  heyu_engine	is to be
     started.  With the default value of MANUAL, the engine must be  started  by
     entering  'heyu  engine' at the command line.  With the value AUTO, the en-
     gine will be started  automatically  along  with  Heyu's  other  background
     processes when 'heyu start' is run.  Example:
       START_ENGINE  AUTO

LOG_DIR directive
     Use  this directive to specify the directory in which the Heyu state engine
     daemon should write its log  file	'heyu.log.<tty>'.   The  keyword  'NONE'
     (which is the default) instructs Heyu to not write a log file.

     Example:
	LOG_DIR  /var/log/heyu/

     The  log  file will contain entries like appear in the Heyu monitor, and in
     addition, an entry whenever a script (excluding  heyuhelper)  is  launched.
     It  will  also collect the text output of a launched script, if that output
     isn't redirected to a different file.

     Two or more instances of Heyu running on the same computer can share a com-
     mon log file by appending the keyword "COMMON".  If each instance	of  Heyu
     is started with the base subdirectory switch (-0 through -9), each entry in
     the  log  file  'heyu.log.common'	will  display the subdirectory number (0
     through 9) from whence the signal originated.

     Example:
	LOG_DIR  /var/log/heyu	common

     Note that the log file will continue to grow.  Manually delete or	trim  it
     from  time  to time, or configure a Unix utility like 'logrotate' to manage
     it.

DATE_FORMAT directive
     Specifies how a numeric date is displayed.  The syntax for  this  directive
     is:
       DATE_FORMAT  <order>  [<separator>]
     where <order> is
       YMD  => Year/Month/Day  (Default)
       DMY  => Day/Month/Year
       MDY  => Month/Day/Year
     and where the optional <separator> is '/' (Default), '-', or '.'

     Examples:
       DATE_FORMAT  YMD  '/' => 2008/01/23  (Heyu default)
       DATE_FORMAT  YMD  '-' => 2008-01-23  (ISO 8601 standard)
       DATE_FORMAT  DMY  '-' => 23-01-2008  (many European countries)
       DATE_FORMAT  DMY  '.' => 23.01.2008  (Germany traditional)
       DATE_FORMAT  MDY  '/' => 01/23/2008  (USA traditional)

     The specified order of Month and Day also applies to the date ranges speci-
     fied  for Timers in schedule files to be uploaded to the CM11A EEPROM.  The
     separator between month and day must be '/', '-' or '.' but does  not  have
     to  be  the same as that specified with DATE_FORMAT.  The separator between
     the begin and end dates may optionally be either '-' or ':'.  (Use the lat-
     ter for clarity when the Month/Day separator is a '-'.)
     Examples:
       TIMER  smtwtfs  01/23-12/31 ...	(with DATE_FORMAT YMD or MDY)
       TIMER  smtwtfs  23-01:31-12 ...	(with DATE_FORMAT DMY)

     Dates where the month name is spelled out are not affected by  this  direc-
     tive and usually appear like:
       Wed 23 Jan 2008

LOGDATE_YEAR directive
     Instructs	Heyu  whether  or  not the dates reported for entries in the Log
     file and Monitor should include the year.	The choices are YES or NO,  with
     the default being NO, to omit the year.

TAILPATH directive
     Use  this	directive to specify the full pathname of the system 'tail' com-
     mand if it's not on the normal PATH accessable to Heyu.  The  Heyu  command
     'logtail' will use this pathspec to call 'tail'.

HEYU_UMASK directive
     Governs  the  permissions	for files created by Heyu.  The default for this
     directive is 0000 which results in files having permissions rw_rw_rw_.  The
     value 0002 results in files having permissions rw_rw_r__ ; the  value  0022
     results in files having permissions rw_r__r__.
     Example:
       HEYU_UMASK  0002

USERSYN directive
SCENE directive
     These directives, new to Heyu version 2, specify a semicolon-separated list
     of  Heyu commands.  These can then be executed sequentially by issuing only
     the usersyn or scene label as a Heyu command.  In addition, the  label  can
     be used in a macro as if it were a command.

     In  the current release, the ONLY difference between a SCENE and USERSYN is
     whether they appear in the scene or usersyn list  displayed  by  the  'heyu
     show'  command.   What applies below for a SCENE applies equally to a USER-
     SYN.

     The format for either a scene or usersyn is similar:
	SCENE	 Label	command1; command2; command3; ...
	USERSYN  Label	command1; command2; command3; ...

     The commands in a scene  can  accept  either  actual  device  addresses  or
     aliases.  (The alias directive must appear before any scene directive which
     references it.)
     Examples:
	SCENE  dim_all	dim A1-3  8; dim B2  8; dim c7	8
	SCENE  night_lights  off porch_light; on garage_light; dim hall 8

     Issuing the command 'heyu dim_all' would result in each of the commands de-
     fined in that scene to be executed in turn.

     Scenes can also be defined with positional parameters which are replaced by
     actual  parameters  when  they are executed.  The positional parameters are
     designated by a '$' sign followed by a number 1 to N optionally enclosed in
     curly brackets, e.g., '$2', '${7}'.  The number represents the position  of
     the parameter in the argument list supplied when the scene is executed..  A
     positional  parameter can be used as part or all of either a device address
     or a dim level, but not as part of a scene label or a Heyu command

     Examples:
	SCENE  blinker	on $1; off $1; on $2; off $2
	SCENE  Dim_all	dim A1-3  $1; dim B2  $1; dim c7  $1

     These could then be executed by running:
	heyu  blinker  A3  B7
	heyu  Dim_all 7

     Rules for scenes (interpret "scene" as meaning either scene or usersyn):

     1. A scene label is a case-sensistive ASCII string (maximum length 32 char-
     acters) not beginning with '-' or '_' and not containing blanks or the  '+'
     or '$' characters.

     2.  A  scene label may not be the same as a Heyu command or any of its syn-
     onyms.  A scene label may not duplicate a usersyn label and vice-versa.  As
     of  the  current  implementation, a scene label MAY be the same as an alias
     label, and it MAY be the same as a macro label, but these	feature  may  be
     restricted in future releases if too much user confusion results.

     3.  Only  "direct"  and CM17A commands can be used in scenes - "administra-
     tive" commands like 'help', 'info', etc., are invalid  in	scenes,  as  are
     commands  identified  as  "legacy"  commands from Heyu version 1.	(Running
     'heyu help' will identify each of these types of commands.)

     4. A command in a scene may not be another scene.

     5. Commands in scenes are checked for syntax when the configuration file is
     read, but there is no checking of any parameter containing a positional pa-
     rameter until the scene is actually executed or specified in a macro.   The
     syntax  checking is performed as if the scene is to be executed at the com-
     mand line, so if a scene contains a command which is  invalid  for  an  up-
     loaded  macro,  that error won't be flagged until the 'heyu upload [check]'
     command is run.

     6.There is no restriction on how a positional parameter is  used  within  a
     parameter	so  long as the result is valid when the scene is executed.  Use
     the optional curly brackets if the result	could  otherwise  be  ambiguous.
     The  positional  parameter  is first replaced by the actual parameter, then
     the result is checked against the list of aliases.

     7. The number of positional parameters supplied when a  scene  is	executed
     must agree exactly with the number specified in the scene definition.  Thus
     if  '$4' is the highest numbered positional parameter specified in a scene,
     then 4 and only 4 parameters must be supplied when the scene is executed.

     8. If more than one scene is used in a macro, or if scenes  are  intermixed
     with regular macro commands, they must be separated by semicolons.

     9.  Memory  for  scenes  is dynamically allocated so there is no fixed size
     limit for scenes intended for execution from the  command	line.	Bear  in
     mind  however the limited (1024 byte) EEPROM space in the CM11A when scenes
     are expanded in macros, although most common X10 commands occupy only 3  or
     4 bytes when converted to binary.

     10. The highest numbered positional parameter in a scene is by default lim-
     ited to 8. (In most cases anything over that is more likely an error.)  But
     this limit may be changed with configuration directive MAX_PPARMS.

MAX_PPARMS directive
     Specifies	the  highest  numbered	positional parameter allowed in a scene.
     The number may have any value between 1 and 999.  The default is 8.

STATUS_TIMEOUT directive
     Specifies how long Heyu will wait for a module to reply to a status command
     before timing out.  The default is 2  seconds.   Some  modules,  SwitchLinc
     dimmers  in particular, may require increasing this to 3.	The allowed lim-
     its for this directive are 1-5 seconds.  (Don't use a value any higher than
     the minimum needed for satisfactory status reporting.)  Example:
	 STATUS_TIMEOUT  2

SPF_TIMEOUT directive
     Specifies how long Heyu will wait for a module to reply to a "SPecial Func-
     tion" status command before timing out.  The  default  is	3  seconds.   To
     date,  there  is only one special function in Heyu, the display of the tem-
     perature as encoded in a preset command returned from a two-way  thermostat
     or remote thermometer.  (See below.)

RCS_DECODE directive
RCS_TEMPERATURE directive
     This  is  the  same directive - use either but not both.  The name has been
     changed since Heyu now supports decoding other RCS status reports	such  as
     fan status on/off in addition to temperature.
     This  directive instructs the Heyu monitor to decode and display the status
     reports encoded in a Preset command transmitted from a  two-way  thermostat
     or  remote  thermometer  employing the algorithm used by the RCS TX15-B and
     TXB16 thermostats (shown as a table in the thermostat user's guide).
     The Smarthome TempLinc Model 1625 remote thermometer uses	the  same  algo-
     rithm for the temperature report, which is:

	temperature = -60 + 32*(unit - 11) + (preset_level - 1)

     If  the  Heyu State Engine is running, the decoded temperature is stored at
     the (fictitious) unit 0 address H0, where 'H' is the housecode of the ther-
     mostat or thermometer.  It can be recovered with the 'heyu rcstemp H'  com-
     mand.  Provided a valid temperature has been stored, any script launched by
     Heyu  can	recover  the  temperature  as  the value of environment variable
     X10_H0 or the environment variable alias for H0.  (Since these  environment
     variables are created only if valid data has been stored, a check for their
     existance, e.g., [ "X10_H0" != "" ], may be required before using them in a
     script or shell command.)

	       *** WARNING - WARNING - WARNING ***
     The  use  of  Heyu  or  any other power-line protocol software to control a
     heater lacking a built-in failsafe mechanism is not only unwise, it is haz-
     ardous to life and downright foolhardy.  DON'T DO IT!

     This directive may have the values: OFF for no decoding; a list if  housec-
     odes  enclosed in square [] brackets for which decoding is to be performed;
     or ALL to decode any housecode.  The default is OFF.
     Examples:
	RCS_DECODE  OFF        (no decoding)
	RCS_DECODE  [CFH]      (decode on housecodes C, F, and H)
	RCS_DECODE  ALL        (decode on any housecode)

     Note: This directive need not be used in order to query the thermostat with
     the 'heyu rcs_req ...' or 'heyu temp_req ...' commands -  it  only  enables
     the  temperature or other status to be displayed in Heyu's monitor, regard-
     less of whether or not the thermostat's transmission was initiated by these
     commands.	(The TempLinc Model 1625 remote thermometer can be programmed to
     transmit a temperature report any time the temperature changes.)

ACK_HAILS directive
     Setting this directive to YES will instruct the Heyu  state  engine  daemon
     (if  running) to send a hail_ack with the default housecode whenever it re-
     ceives a hail signal over the power line.	The hail_ack is sent as if  from
     a launched script.  The choices are YES or NO, with the default being NO.
     Example:
	ACK_HAILS  NO

AUTOFETCH directive
     When  a state command which returns the addressed state of a module is exe-
     cuted at the command line, Heyu by default (AUTOFETCH  YES)  instructs  the
     state  engine to first update the state file, since Heyu only automatically
     updates this file following an X10 function. Setting the value of	the  di-
     rective  to  NO  disables	this action for (only) those specific state com-
     mands.  Most users will want to accept the default value of YES.	See  the
     description  of the 'fetchstate' command in man page heyu(1) for a more de-
     tailed discussion of this issue.

TIMER_LOOPCOUNT directive
     Specifies the base loopcount for the fast timing loops needed by some CM17A
     and experimental commands.  To determine the value for this directive,  run
     'heyu utility calibrate'.

FORCE_ADDR directive
     Heyu  doesn't normally send a separate Housecode|Unit address byte for com-
     mands like all_lights_on which don't actually require the unit number  (the
     housecode	is  included  with the function), or for extended commands which
     contain the unit number within the function code.	However  X-10's  Active-
     Home software always sends this byte, generally using unit 13.  This direc-
     tives forces Heyu to always send an address byte.
     If always sending an address byte cures some problem you are having, choose
     YES. Otherwise take the default of NO.
     Example:
	FORCE_ADDR  NO

SPOOLFILE_MAX directive
     This directive sets the limit on the size of the spoolfile beyond which the
     Heyu  relay  daemon  will	rewind it once it detects a period of inactivity
     (currently 5 seconds).  The size set by this directive may  be  between  20
     and  an absolute maximum 1048576 bytes (but don't use this max value).  The
     default limit is 1000000 bytes.  For changes in this  directive  to  become
     effective when Heyu is already running, use the 'heyu restart' command.

     Note  that  re-synchronization with the Heyu state engine daemon or monitor
     takes a couple of seconds, during which time Heyu will ignore incoming  X10
     signals  or  macro executions.  So don't set a low limit except for testing
     purposes.

SECTION directive
     This directive and anything which follows it on the  line	is  treated  the
     same  as  a  comment and totally ignored by Heyu.	It is provided to enable
     user-definable breakpoints for use by an external program or script to  re-
     organize the Heyu configuration file.

CHECK_RI_LINE directive
     When  the	CM11A  receives an X10 signal over the power line it asserts the
     Ring Indicator (RI) serial line for a short time prior to sending the  sig-
     nal  to  the  computer.   This directive tells Heyu whether or not to check
     this serial line before attempting to transmit a  command	so  as	to  help
     avoid collisions on the powerline.  The default is YES.  This check is nor-
     mally  bypassed  for serial port hardware which does not support the serial
     control lines, so setting this directive to NO should only be  required  in
     exceptional situations.  One such situation occurs with USB-Serial adapters
     using an older Prolific chip under Linux, resulting in the message "RI ser-
     ial  line	may  be stuck" after a long delay.  Note that this check will be
     ineffective if the CM11A RI line is disabled by the following directive.

RING_CTRL directive
     Setting the value of this directive to DISABLE instructs  Heyu  to  disable
     the  CM11A  Ring Indicator (RI) line of the CM11A, which would otherwise be
     asserted each time an X10 signal is received over the powerline.  In  addi-
     tion,  Heyu commands like 'heyu ping' and 'heyu wait' which normally employ
     the CM11A Ring_Enable command for their functionality will  substitute  the
     CM11A  Ring_Disable  command.   This directive is not totally effective be-
     cause the CM11A asserts the RI line when it is powered up, before Heyu  has
     a	chance	to disable it, e.g., in the event of a momentary interruption in
     AC power.

     The ONLY reason for disabling the RI line is that	some  computers  have  a
     "Start  on  Ring"	feature  and/or "Awake from Sleep on Ring" feature which
     cannot easily be disabled in the computer's BIOS and disabling the CM11A RI
     line prevents undesired startup of the  computer.	 Otherwise  the  default
     value of ENABLE for this directive should not be overridden since the func-
     tion to check the RI line before sending would then be ineffective.

     For changes in this directive to become effective when Heyu is already run-
     ning,  use  'heyu	restart' to incorporate the change in the heyu_relay and
     heyu_aux daemons.

SEND_RETRIES directive
     Heyu by default attempts to send an X10 address or function command to  the
     CM11A  up	to  3 times, which is the default for this directive.  If colli-
     sions or noise on the power line result in  _occasional_  "Unable	to  send
     ..."  messages,  use  this directive to bump up the number a little.  Note:
     This directive will not help if the failure to send a command is due  to  a
     communication problem with the serial port.
     Example:
	SEND_RETRIES 5

POWERFAIL_UPDATE directive
     When  AC  power resumes after an interruption, the CM11A will poll the com-
     puter with a constant stream of requests at one-second intervals for a time
     update and will accept no other command until  the  request  is  satisfied.
     The  Heyu	relay  daemon  by default automatically responds and updates the
     CM11A clock.  The choices for this directive are either YES or NO, with the
     default being YES.  Choosing NO for this directive instructs heyu_relay  to
     respond with a truncated update which satisfies the CM11A but doesn't actu-
     ally  reset  the clock.  If Heyu is already running, use 'heyu restart' for
     changes in this directive to become effective in the heyu_relay daemon.

     This directive allows the user to determine the accuracy of the CM11A clock
     when operating solely on battery power. E.g., run 'heyu  setclock'  to  set
     the  CM11A clock to the system clock, unplug the CM11A from the wall socket
     for several hours or a day, plug it back in and  run  'heyu  readclock'  to
     compare the CM11A and system clocks.

NEWFORMAT flag (obsolete)
     The word NEWFORMAT formerly caused the output displayed in the Heyu monitor
     to  appear  in  a slightly different format.  In Heyu version 2 the monitor
     output is very different and the older formats  are  no  longer  supported.
     This directive will be ignored if it appears in the configuration file.

	    ===============================================
     The  following Directives are applicable when scripts are to be executed by
     Heyu in response to an X10 signal.  (See 'man x10scripts(2)' for details.)
	    ===============================================

SCRIPT_MODE directive
     The options are HEYUHELPER or SCRIPTS, with the default being SCRIPTS.

     If HEYUHELPER is chosen, a shell script named 'heyuhelper'  on  the  user's
     path  is  executed  every time an X10 function is received by Heyu from the
     interface.  The argument supplied to the script is  of  the  form	<housec-
     ode|last_unit|function>, where:
	housecode is the lower case letter a-p associated with the function
	  which resulted in execution of 'heyuhelper'
	last_unit is the last unit code received on that housecode.
	function will be one of the following:	On, Off, AllOn, AllOff,
	  Dim, Bright, LightsOn, LightsOff, Preset, Extended, Hail, HailAck,
	  Status, StatusOn, StatusOff, DataXfer.

     Examples of heyuhelper arguments:	a1On  b3Off c14Preset

     Note: The AllOn command in Heyu version 1.xx was interpreted to mean Light-
     sOn (All Lights On).  It is not a native CM11A command.  In Heyu version 2,
     it  instead  indicates the simple 'On' function whenever all units 1-16 are
     addressed.

     Another difference from Heyu version 1.35 is that the heyuhelper script  is
     not launched when an uploaded macro is executed.

     The heyuhelper script is only executed when X10 functions are received from
     the  interface  -	not when addresses or powerfail messages are received or
     when functions are sent.

     All other script-oriented directives with the exception of SCRIPT_SHELL and
     SCRIPT_CTRL are ignored with the HEYUHELPER option.  Choosing  SCRIPTS  al-
     lows one to use the full features of Heyu scripting (including execution of
     an existing 'heyuhelper' script).

SCRIPT_CTRL directive
     Globally  enables	or  disables  launching of scripts by Heyu.  The default
     value of ENABLE permits scripts to be launched; the value DISABLE	inhibits
     them  from being launched.  This will hopefully be useful when the configu-
     ration file contains many SCRIPT directives and it is desired to  temporar-
     ily disable them without having to delete them or comment them all out. All
     scripts  are  affected,  including  heyuhelper  and  powerfail  or  rfflood
     scripts.  (This directive may be overridden at  the  command  line  by  the
     'heyu script_ctrl enable|disable' command.)

SCRIPT directive
     Specifies	the  Linux/Unix  command to be launched and the conditions under
     which it will be launched.  The conditions for launching  the  command  may
     also (or additionally) be specified separately in a LAUNCHER directive.
     The format is as follows:
	SCRIPT [-l <label>] <launch conditions> :: [exec options] <command line>

     The  script  label is optional as long as the all the launch conditions are
     contained within the SCRIPT line.	It can be any  arbitrary  case-sensitive
     name up to 32 characters in length, not beginning with a '-' character.  If
     no  label is specified, Heyu will create one using the line number where it
     appears in the config file to make it unique, e.g., 'Script_21'.
     If the launch conditions are wholly or in part specified  with  a	LAUNCHER
     directive,  a  script  label  is  mandatory,  so that Heyu can match up the
     script with the assocated launcher.

     Launch conditions can be quite simple, like 'A1 on', or quite complex.   In
     addition,	there are special launch condition for extraordinary situations:
     -powerfail', '-rfflood', '-timeout'.
     See x10scripts(5) for a full description of launch conditions.

     Keep in mind that Heyu will normally launch a script only for the first set
     of launch conditions which are satisfied, i.e., only one script is launched
     per signal or special condition, although this restriction can be	overrid-
     den.  Launch conditions are tested in the order they appear in the configu-
     ration file.

     The  symbol  '::' (two colons) is always required (so that Heyu can distin-
     guish when the launch conditions end and the command line starts).

     Exec options are zero or more of the following:
	-xtend (or simply -x)	Create	an  environment  compatible  with  Xtend
     scripts.
	   (No other options are compatible with -xtend.)

	-rawlevel  (or	simply -r)  Use native raw dimlevels instead of percent-
     ages
	   for state bitmaps in the Heyu environment.

	-noenv (or simply -n) Provide no additional environment variables
	   beyond those already in the user's environment.

     The <command line> can be any executable binary,  shell  script,  or  shell
     command.

     Examples:
	SCRIPT	D1 on ::  doorbell_actions.sh
	SCRIPT	-l wake_em_up  C1 on :: play $HOME/music/reveille.wav
	SCRIPT	 -l  PowerFail	-powerfail :: echo "There was a power failure" |
     mail
	SCRIPT	-l RF_Flood  -rfflood :: heyu on Siren
	SCRIPT	-l Timeout -timeout timer2 :: echo "Timeout on Timer number 2" |
     mail

     If a script directive references an alias in place of a housecode|unitcode,
     the alias directive must have been defined  earlier  in  the  configuration
     file.

LAUNCHER directive
     This optional directive can wholly or in part specify the condition or con-
     ditions under which the associated script will be executed (or 'launched').
     The format is:
	LAUNCHER <script label> <launch conditions>; <launch conditions>; ...
     where:
	<script label> identifies the associated script with the same label.

     See x10scripts(5) for a full description of what can appear in <launch con-
     ditions>.

     Multiple  launchers  for  the same script may be continued on the same line
     following a semicolon, or may be configured as separate LAUNCHER lines.

     Example:
     If no launch condition was specified in the 'wake_em_up' script  above,  it
     would be specified in a launcher like this:
	LAUNCHER  wake_em_up  C1  on

LAUNCHER_SCANMODE directive
     See section "SCAN MODE" in man page x10scripts(5) for details.

SCRIPT_SHELL directive
     Defines  the  shell used when a script is executed. (Provide the full path-
     name.)  The default is to use the shell defined by the  SHELL  variable  in
     the user's environment, or /bin/sh if no such variable exist.

LAUNCHPATH_PREFIX directive
LAUNCHPATH_APPEND directive
     Prefix and/or append an additional directory or directories to the existing
     $PATH  in	the environment provided for Heyu scripts.  (This works only for
     shells where the path separator is a semicolon.)
     Example:
	LAUNCHPATH_APPEND  /etc/heyu/scripts

LAUNCH_SOURCE directive
     Sets the default source or sources of the X10 signal allowed  to  launch  a
     script  as  part  of the <launch conditions>.  One or more of the following
     may be specified.	The default is RCVI.
     SNDC   Sent from the Heyu command line.
     SNDM   Sent upon execution of an uploaded macro by a Timer.
     SNDT   Sent upon execution of an uploaded macro by a Trigger
     SNDP   Sent by Heyu from a power-fail script.
     RCVI   Received over the power line via the CM11A interface.
     RCVT   A Trigger which initiates execution of an uploaded macro.
     SNDA   Sent over the power line by the heyu_aux daemon.
     RCVA   Virtual data received from the heyu_aux daemon.
     ANYSRC All of the above.
     NOSRC  None of the above (sources must be specified in the  <launch  condi-
     tions>).

     Example:
	LAUNCH_SOURCE  rcvi  sndc

ISDARK_OFFSET directive
     Defines  the offset in minutes from Dusk and Dawn to use for the script en-
     vironment logical variable 'X10_isDarkTime'.  Its default value of 30  min-
     utes  means  that	'X10_isDarkTime' will be TRUE from 30 minutes after Dusk
     until 30 minutes before Dawn.  This directive also determines the	interval
     during which the launch condition flag 'dark' is TRUE.

ENV_ALIAS_PREFIX directive
     Determines whether the prefix of ALIAS environmental variables provided for
     scripts is upper or lower case, i.e., 'X10_' or 'x10_'.  The choices are LC
     or UC, with the default being LC for lower case.

     This  directive  enables compatibility with scripts written for earlier re-
     leases of Heyu (which used the upper-case prefix), however its use is  dis-
     couraged  -  please modify your scripts to use the lower-case 'x10_'as soon
     as practicable.
     Note that this prefix applies _only_ to ALIAS environment variables  -  all
     other  Heyu  environment  variables use the upper-case prefix.  E.g, if the
     configuration file defines:
       ALIAS  porch_light  A6
     then the environment variables provided will be:
       x10_porch_light=nnnn
       X10_A6=nnnn

STATE_FORMAT directive
     If set to the value OLD, the output of the state commands 'onstate',  'dim-
     state',  'chgstate', and 'addrstate' revert to the former heyuhelper style,
     e.g., a2Dim.  Taking the default value NEW  displays  output  as  either  1
     (True)  or 0 (False) when a housecode|unit parameter is provided, or a unit
     bitmap of the state (bit 0 -> unit 1) as a decimal integer when the parame-
     ter is a housecode only.  This directive is intended to provide compatibil-
     ity with existing scripts.

STATE_CTRL directive
     With the default value of "SINGLE" for this directive, the output of  state
     commands 'onstate', 'dimstate', 'chgstate', and 'addrstate' is boolian 0 or
     1	when the address parameter includes the unit, or a bitmap if the address
     parameter is only a housecode.  Specifying the value of this  directive  as
     "BITMAP"  results in the output being a bitmap regardless of whether or not
     the address include a unit.

	    ===============================================
     The following Directives are applicable  when  a  schedule  of  Timers  and
     Macros is to be uploaded by Heyu to the CM11A's EEPROM.
	    ===============================================

SCHEDULE_FILE directive
     Instructs	Heyu  to  use  the named file as the user's schedule file (which
     must be in the same directory as the configuration file).	The  default  is
     x10.sched.
     Example:
	SCHEDULE_FILE  vacation.sched

MODE directive
     Heyu  can operate in one of two modes insofar as uploaded timers and macros
     are concerned.  But before getting into these, first a few words about  the
     CM11A interface's internal clock:

     The  CM11A clock has no notion of actual dates, but is merely a day counter
     which starts from 0 and increments daily until it reaches 365 (a  total  of
     366  days),  after  which it rolls over to 0.  An independant counter keeps
     track of the weekday, starting at 0 (Sunday) and incrementing daily through
     6 (Saturday) before rolling over to 0.  Additional  counters  track  hours,
     minutes,  and seconds with the usual rollovers. (The CM11A has no notion of
     Standard versus Daylight Time.)  The day  and  weekday  counters  increment
     when the time rolls over to 0:00:00.

     In  either  mode,	the  CM11A  clock is maintained by Heyu on Standard Time
     thoughout the year.  Timers scheduled by  the  user  in  Civil  (i.e.  wall
     clock)  time are automatically divided by Heyu into separate timers for pe-
     riods of Standard and Daylight Time during the year.   Time  management  is
     intended to be handled by Heyu transparently to the user.

     In  COMPATIBLE  mode,  the CM11A clock is configured such that Day 0 corre-
     sponds to Jan 1st in the current year and the uploaded schedule  of  timers
     and  macros  is prepared to run for 366 days, i.e., through either Dec 31st
     or the following Jan 1st, depending on whether the current year is  a  leap
     or common year.  In order to maintain the proper correspondence, the user's
     schedule must be re-uploaded on Jan 1st, at least in years following common
     years.  (The  CM11A will otherwise keep chugging away, but events fired off
     will be a day in error.)

     In HEYU mode, the CM11A clock is configured such that Day 0 corresponds not
     to Jan 1st but to today's date.  The uploaded schedule can be configured to
     run for any period between 1 and 366 days via the	PROGRAM_DAYS  directive.
     (See  the description of that directive for reasons for wanting this.)  The
     user's schedule can be re-uploaded at any time prior to expiration  of  the
     PROGRAM_DAYS  period and correspondance will be maintained for the next pe-
     riod of PROGRAM_DAYS.  Note however that if this period is allowed  to  ex-
     pire  without  re-uploading  the schedule, the CM11A will cease to fire off
     any programmed events (unless of course the period is set for 366 days).

     The schedule should be programmed for the entire  year  regardless  of  the
     MODE  or  PROGRAM_DAYS  directives.  Based on those directives, Heyu deter-
     mines what parts of it to use and what parts  to  ignore.	 In  HEYU  mode,
     events  scheduled	for  execution	on  dates earlier than today's date wrap
     around into next year.
     Examples:

	MODE  COMPATIBLE
	MODE  HEYU

	       *** WARNING - WARNING - WARNING ***
     Users running PCs configured for dual-boot  between  Linux  and  MS-Windows
     should  NOT  operate Heyu in HEYU mode if they expect to ever manually exe-
     cute X-10's ActiveHome(TM) program (or allow  its	"Communications  Bridge"
     driver to be launched at boot time).  Here's why:

     If  the  CM11A  detects  that its AC power has been interrupted, even for a
     very short time, it will continually issue commands back to the PC request-
     ing a clock  update.  ActiveHome  and/or  its  Communications  Bridge  will
     _silently_  comply with this request (as will Heyu's Relay), but ActiveHome
     will set the CM11A clock to an incorrect  date  and  time	for  HEYU  mode.
     (This  is easily and automatically corrected by running the 'heyu setclock'
     command, but the PC has to be rebooted back into Linux/Unix to do it.)

PROGRAM_DAYS directive
     When operating Heyu to upload timers and macros to the CM11A  interface  in
     HEYU  mode,  this directive instructs Heyu to compile the uploaded schedule
     to run for the number of days specified (1-366), beginning today.	This di-
     rective is ignored when Heyu is operated in COMPATIBLE mode.   The  default
     value is 366 days.  Example:

	PROGRAM_DAYS  90

     The  advantage to running for a shorter number of days becomes evident when
     timers are programmed for Dawn- or Dusk-relative  times.	Because  of  the
     limited  size  (1024  bytes) of the CM11A EEPROM memory, Heyu uses a stair-
     step approximation to the daily times  of	Dawn  and  Dusk  over  the  PRO-
     GRAM_DAYS interval.  The unequal-length step intervals are determined iter-
     atively  to minimize the error while fitting in the available EEPROM memory
     space.

     As a result, even a single Dawn- or Dusk-relative timer will generally  oc-
     cupy  most  of  the  EEPROM space.  However as more timers are added to the
     schedule, the stair-steps are recalculated so everything will fit, although
     at the expense of a larger error.

LATITUDE directive
LONGITUDE directive
     These are used to allow Heyu to compute the times of dawn and dusk over the
     year for your particular location.  There are no defaults.

     The format of the directive line is the word LATITUDE followed by	a  space
     and then the direction, degrees, a colon and the minutes. The LONGITUDE di-
     rective follows the same format.  Example:
	LATITUDE  N37:41
	LONGITUDE W121:52

     Note:  Versions  of  Heyu	earlier than 2 did not use a direction (N/S/E/W)
     symbol and assumed the convention that positive Latitude is North and posi-
     tive Longitude is West.  For compatibility, Heyu version 2  will  make  the
     same assumptions if the direction symbol is omitted.

COMBINE_EVENTS directive
     This  directive  instructs Heyu whether or not to combine events which have
     the same day-of-week code, date range, type (i.e.,  Clock,  Dawn,	or  Dusk
     based), and time-of-day.  Heyu then needs to upload only a single timer ex-
     ecuting  a  concatenated  macro, which saves considerable EEPROM space when
     Dawn/Dusk relative timers are programmed.
     The choices are YES or NO, with the default being YES.
     The downside to using this feature is that the Heyu-assigned  name  of  the
     concatenated macro will not be easily recognizable when displayed in Heyu's
     monitor.

COMPRESS_MACROS directive
     This  directive instructs Heyu to merge unit codes for macro elements which
     have the same command, housecode, and "data" (e.g.  dim  level),  and  also
     eliminate	duplicate  elements.   It  can save a few bytes of EEPROM space,
     when macros with similar elements are concatenated.
     The choices are YES or NO, with the default being NO.

     Example:
	macro mac1 0  on A1; on B1; on A2; on B3
     becomes:
	macro mac1 0  on A1,2; on B1,3

     Warning: If you program a macro like:
	macro mac1 0  on A1; off A1; on A1; off A1; on A1; off A1; ...
     and expect to have a lamp on A1 repeatedly blinking on and off, better  set
     this  directive to NO, else the macro will be compressed to a single on and
     off.  (Heyu maintains the ordering in macros to the extent possible.)

DAWNDUSK_DEF directive
     By default Heyu defines Dawn and Dusk to be Sunrise and Sunset.   This  di-
     rective  allows  globally	defining them instead as the morning and evening
     times of several standard twilights, or as times calculated  for  a  custom
     position  of  the Sun centre below the horizon, specified in angle minutes,
     as follows:
     RISESET (or simply 'R') - Sunrise and Sunset (default)
     CIVIL (or simply 'C') - Civil Twilight
     NAUTICAL (or simply 'N') - Nautical Twilight
     ASTRONOMICAL (or simply 'A') - Astronomical Twilight
     OFFSET [-]NN (or simply 'O [-]NN') - Sun position in  angle  minutes  below
     the horizon (actually above the horizon if -NN)

     Example:
       DAWNDUSK_DEF  CIVIL
       DAWNDUSK_DEF  N
       DAWNDUSK_DEF  OFFSET 0

DAWN_OPTION directive
DUSK_OPTION directive
     These  directives	instruct Heyu how to assign the time for Dawn or Dusk in
     each timer subinterval. The options for this directive are:
     FIRST    - Use the Dawn/Dusk time for the first day in the subinterval.
     EARLIEST - Use the earliest of the times for any day in the subinterval.
     LATEST   - Use the latest of the times for any day in the subinterval.
     AVERAGE  - Use the arithmetic average of the times in the subinterval.
     MEDIAN   - Use a time halfway between the earliest and latest times.

     The default is FIRST, which is the most  convenient  for  comparing  Heyu's
     computations  with  Dawn/Dusk  times  published  in newspapers or by the US
     Naval Observatory.  (Remember that Heyu's times are  Standard  Time,  while
     newspapers generally publish Civil [wall clock] times.)

MIN_DAWN directive
MAX_DAWN directive
MIN_DUSK directive
MAX_DUSK directive
     These  directives	allow  bounds to be placed on the times of Dawn and Dusk
     computed by Heyu. For example, setting the value for MIN_DAWN to 06:30 will
     instruct Heyu to execute a timed event scheduled for dawn at 06:30 instead,
     whenever the computed time for dawn is earlier than  06:30.   These  direc-
     tives may be useful for users in extreme latitudes, when for example a lamp
     is scheduled to turn on at dusk and turn off at 9:30 PM.  But if during the
     summer  months  dusk actually occurs after that hour, then the on/off cycle
     of the lamp would normally be reversed, turning on at that  late  dusk  and
     remaining on until 9:30 PM the following day.

     The  value  for  these directives are specified as hh:mm Civil (i.e., wall-
     clock) time.  The directives may be disabled with the word OFF in place  of
     a time.  The default is OFF.

     Heyu  version 2 now has timer options for conditional compilation of events
     depending on the values of Dawn and Dusk, so these directives may no longer
     be useful.

     (Note: Due to Heyu's optimizations, the order in which events scheduled for
     the same time are actually executed is not necessarily that in  which  they
     appear  in the user's schedule file.  Allow at least a one minute time dif-
     ference when order is important.  The actual order can be	determined  from
     the  list	of  timers  in	the OUTPUT TIMERS section of the report.txt file
     written when a schedule is uploaded or upload checked.)

DAWN_SUBSTITUTE directive
DUSK_SUBSTITUTE directive
     These directives are obsolete and will be ignored.

REPORT_PATH directive
     Reports 'report.txt' and/or 'cronreport.txt' created when the command 'heyu
     upload [check|croncheck]' is run are by default written in  the  Heyu  base
     directory,  i.e.,	the  directory	where  the configuration file is stored.
     This directive instructs Heyu where the user would like  them  written  in-
     stead.  The full pathspec is required (127 characters maximum).
     Example:
	REPORT_PATH  ./

WRITE_CHECK_FILES directive
     When  a  schedule	is actually uploaded to the CM11A's EEPROM, Heyu records
     critical information in the files 'x10record', 'x10macroxref', and  'x10im-
     age'.   For  debugging  or informational purposes, this directive instructs
     Heyu to write these files with a .check extension when 'heyu upload  check'
     is run.

     In addition, this directive instructs Heyu to write 'x10image.hex' which is
     a human-readable hex dump of the EEPROM memory image.

     The choices here are YES or NO.  The default is NO.

REPL_DELAYED_MACROS directive
     This  directive instructs Heyu to replace events having delayed macros with
     new events and new undelayed macros when  possible.   (The  purpose  is  to
     avoid  pending  delayed macros, which are purged when a new schedule is up-
     loaded.)  The choices are YES or NO, with the default being YES.

ASIF_DATE directive
     Used for test purposes, this directive instructs Heyu to substitute the ar-
     gument date for today's date when processing the user's schedule file.
     The date format is yyyymmdd.
     Example:
	ASIF_DATE  20020621

ASIF_TIME directive
     Used mainly for test purposes, this directive instructs Heyu to use the ar-
     gument time of day instead of the system time when  processing  the  user's
     schedule file. Its format is hh:mm (Civil Time).  The default is to use the
     current system time.
     Example (simulates operation at Noon):
	ASIF_TIME    12:00

FEB_KLUGE directive
     Heyu ver 2 always interprets 02/30 as the last day of February when used as
     a	start  or  stop  date.	 This directive instructs Heyu to also interpret
     02/28 and 02/29 as the last day of February.  The options here are  YES  or
     NO,  with	YES  being the default.  (If you choose NO, programming 02/28 or
     02/29 in the wrong year could result in a skipped day, an	event  occurring
     twice, or possibly an error, depending on circumstances.)

RESOLVE_OVERLAP directive
     When uploaded timers specify Dawn/Dusk periods with different begin and end
     points,  Heyu  resolves the situation such that the approximation time used
     for Dawn and/or Dusk is the same for every timer on any given  day.   There
     are  two  methods for doing this and in most cases the newer method appears
     to give better results in term of maximum error on Dawn or Dusk.  This  di-
     rective  allows returning to the previous method if more satisfactory.  The
     choices here are OLD or NEW, with the default being NEW.
     If the timers in your schedule involve only clock times  or  don't  involve
     both  Dawn  and  Dusk-relative times, either choice will yield the same re-
     sult.
     (A future release of Heyu will make this  determination  automatically  and
     obsolete this directive.)

FIX_STOPSTART_ERROR directive
     With parameter "YES" is a work around for the CM11A EEPROM bug "Stop Time =
     Start  Time"  which  is  occasionally  encountered  when uploading specific
     schedules.  It should be used (generally as a "config" line in the schedule
     file) only when needed as it results in less efficient use  of  the  EEPROM
     memory space.

	    ===============================================
     The following directives are applicable to CM17A
	    ===============================================

RF_POST_DELAY directive
     This  directive specifies the delay in milliseconds following each standard
     RF command to a CM17A "Firecracker" to allow time for  the  transceiver  to
     respond with its power line signal.  The default is 850 milliseconds.
     Example:

       RF_POST_DELAY  850

RF_FARB_DELAY directive
RF_FARW_DELAY directive
     Specifies	the  delay  in	milliseconds  following respectively a 'farb' or
     'farw' RF command to a CM17A.  The default is 850 milliseconds.  This delay
     is specified separately from that for the	standard  RF  commands	so  that
     these  commands  can be used to control devices that don't involve a trans-
     ceiver and power line signals.

RF_BURSTS directive
     Specifies how many RF bursts (1-5) are to be transmitted with  each  actua-
     tion of the CM17A commands fon, foff, fdim, fbright, flightson, flightsoff,
     falloff,  farb,  and  farw.   Some transceivers will repeat some power line
     signals more than once when they receive the default 5 RF bursts.	This  is
     ordinarily  not  a  problem  except possibly when the particular power line
     signal is used to launch a script, in which event	this  directive  can  be
     useful.

     This directive has the syntax:
     'RF_BURSTS <command> <bursts> [<command> <bursts> [...]] ', e.g.,
       RF_BURSTS falloff 3 flightson 3 fdim 4

     Note:  Previous releases of Heyu required that each command be entered on a
     separate RF_BURSTS line and multiple RF_BURSTS  directive	lines  were  al-
     lowed.

     The  default  for	all  CM17A  commands  is  5  bursts.  For commands fdim,
     fbright, and farb where the total number of bursts is specified on the com-
     mand line, the CM17A will be actuated multiple times, with the maximum num-
     ber of bursts each time specified by this directive.

     The RF_BURSTS directive is not used for the  "fast"  ffdim,  ffbright,  and
     ffarb commands.

TIMER_LOOPCOUNT directive
     Specifies	the  base  countdown  for  fast timing loops.  These are usually
     needed to actuate the CM17A for the "fast"  'ffdim',  'ffbright',	'ffarb',
     and  'ffarw'  commands.  The value to use for this directive is obtained by
     running 'heyu utility calibrate'.

     For the CM17A fast commands, the default value of zero  instructs	Heyu  to
     use a kernel timer instead of a timing loop, but the resolution of the ker-
     nel timers for most Unix/Linux kernels is not fine enough for this purpose.

CM17A_BIT_DELAY directive
     Specifies	the  programmed delay in _microseconds_ between bits sent to the
     CM17A device.  X10's RF protocol specifies a minimum  of  500  microseconds
     and  the  default here is 500 microseconds.  For Linux at least the minimum
     resolution of the kernel timer is usually much longer than this,  typically
     10  milliseconds,	so changing the value probably won't accomplish anything
     except for the "fast" CM17A commands when a timing loop is used.

DISPLAY_RF_XMIT directive
     Determines whether an entry will appear in the monitor and log file when  a
     CM17A  command is executed.  The choices are NO or YES or VERBOSE, with the
     default being YES.  Using VERBOSE is like YES but the triplet [XX YY B]  is
     appended  to  each displayed entry.  The XX, YY, and B are respectively the
     two hex bytes and decimal bursts which could be sent  with  the  equivalent
     'farb XX YY B' command.

     One quirk is that with multiple CM17A commands the RF entries will not nec-
     essarily  be  properly  interleaved  with the entries for transceived power
     line signals resulting from the RF command.   This  is  because  the  CM11A
     doesn't instantly report reception of the power line signals - there can be
     a	delay  of  a  second  or  more.   The only workaround is to increase the
     RF_POST_DELAY to 2000 or 3000 milliseconds, which really slows down the  RF
     commands.

RF_NOSWITCH directive
     This  directive determines whether actuation of the built-in appliance mod-
     ule switch on an X-10 TM751 or RR501 is to be suppressed  when  the  trans-
     ceiver  receives  the  fon, foff, or falloff RF signal on the unit code for
     the switch.  Setting the parameter of this directive to YES  will	suppress
     actuation	of the switch with its accompanying loud audible click.  The de-
     fault is NO.

	    ===============================================
     The following directives provide controls for RF input  to  Heyu  from  the
     auxiliary	port  daemon heyu_aux.	They're more fully explained in man page
     x10aux(5).

	    ===============================================

TTY_AUX directive
     Specify the auxiliary serial port or network address and  RF  receiver  de-
     vice.

       TTY_AUX	<serial_port or network_address:port>  <receiver device>
     where <receiver device> is W800RF32A, MR26A, or RFXCOM.  Examples:
       TTY_AUX	/dev/ttyS1  W800RF32A
       TTY_AUX	10.10.10.10:10000  RFXCOM

     There is no default for this directive.

SUPPRESS_RFXJAM directive
     Older  firmware  versions	of  the RFXCOM receiver sent a special "jamming"
     signal when they detected RF jamming, but the  system  was  prone	to  many
     false  positives  and  the feature was removed.  This directive allows sup-
     pressing the jamming signals from older RFXCOM versions by treating them as
     RF Noise.
     The options for this directive are YES or NO, with the default being NO.

ALIAS directive
     For RF signals received by the W800RF32A from security remotes and sensors,
     this ALIAS format maps the device to a housecode|unit address.
       ALIAS  <label> <housecode|unit> <device model>  <ID> [<ID> [<ID>...]]
     where <ID> represents the security ID of a device expressed as a  hexadeci-
     mal  number, either with or without the "0x" prefix.  Up to 16 security IDs
     can be associated with a single housecode|unit address in the case of  mul-
     tiple  security  remotes  of the same model.  (Each sensor device should be
     mapped to its own address.)  Examples:
       ALIAS kitchen_door F11 DS10A 0x3c
       ALIAS keychain_remote G8 KR10A 2a b4 c7

     The ID for entertainment remotes like the UR81A is fixed  and  included  in
     the model, so isn't specified with the ALIAS directive.

TRANSCEIVE directive
RFFORWARD directive
     Determine	which  housecodes which are to be transceived to power line code
     (source SNDA) by the heyu_aux daemon and which housecodes are forwarded di-
     rectly (source RCVA) to the heyu_engine daemon  for  launching  scripts  or
     whatever.	These applies only to signals from Standard X10 remotes, not se-
     curity or entertainment remotes.
       TRANSCEIVE  <list>
       RFFORWARD  <list>
     where <list> may be the keywords ALL or NONE, or may be a string of housec-
     ode  enclosed  in	square [] brackets.  Additionally, the keyword ALLEXCEPT
     followed by the housecode string in square brackets may be used. Example:
       TRANSCEIVE  [BFH]
       RFFORWARD [DE]
     which will transceive standard X10 RF signals on housecode B, F, and H, and
     forward X10 RF signals on housecodes D and E.   RF  signals  on  all  other
     housecodes will be ignored.  Another example:
       TRANSCEIVE [BFH]
       RFFORWARD ALLEXCEPT [BFH]

     The  default for the TRANSCEIVE directive is ALL, and for the RFFORWARD di-
     rective is NONE, meaning that signals on  all  housecodes	will  be  trans-
     ceived.  The same housecode cannot be both transceived and forwarded.

     Certain  special  module  types have options to override the TRANSCEIVE and
     RFFORWARD lists for specific units and functions within a housecode.

TRANS_DIMLEVEL directive
     This directive specifies the dim level (1-22) for each  RF  Dim  or  Bright
     signal  transceived  (or  forwarded)  by  heyu_aux.  The default level is 2
     which results in a brightness level change of about 6 percent  in	standard
     X-10 Lamp Modules.
     Example:
       TRANS_DIMLEVEL  2

AUX_REPCOUNTS directive
     This directive instructs heyu_aux how to handle multiple bursts in an unin-
     terrupted sequence by providing 3 numbers:
       AUX_REPCOUNTS  <MIN> <REPEAT> <MAX>
     See  man  page  x10aux(5) for details.  Most users won't need to change the
     defaults (1 8 200) for this directive.

DISPLAY_RAW_RF directive
     This directive instructs Heyu whether or not to display  the  raw	RF  data
     bytes  from the receiver device.  The choices are the default "NONE" to not
     display any raw data, "NOISE" to display data which heyu_aux judges  to  be
     RF  noise,  or  "ALL"  to	display both noise and normal raw RF data.  Only
     change from the default for testing or debugging.

SECURID_16 directive
     This directive determines whether Heyu will use the full 16-bit ID of secu-
     rity sensors when received by a RFXCOM receiver in variable  length  packet
     mode.   It  is  provided  primarily for temporary backward compatibility in
     case the user has a large number of sensors configured with 8-bit IDs,  un-
     til  they	can be reconfigured.  The parameters are YES or NO, with the de-
     fault being YES.  The ID of a security device which transmits only an 8-bit
     ID is taken to be the lower byte of the 16-bit ID.

SECURID_PARITY directive
     Security sensor transmissions include a parity check on the upper 8-bits of
     a 16-bit ID.  Some sensors, notably the Aux channel of the DS90 Door/Window
     sensor, incorrectly report the parity on half of the RF repetitions.   This
     directive with parameter YES (which is the default) instructs Heyu to check
     the  parity.  The parameter NO instructs Heyu to ignore the parity.  Use NO
     only if you have a sensor exhibiting this bug.

HIDE_UNCHANGED directive
     This directive applies only to transmitters identified by their module type
     as having a "heartbeat", i.e., sensors which periodically repeat their cur-
     rent state as an "I am alive" indication.	The choices are YES or NO,  with
     the default being NO.  With YES, the sensor signal is displayed in the mon-
     itor and log file only when there's a change from the previous state of the
     sensor or if the signal launches a script.

HIDE_UNCHANGED_INACTIVE directive
     As above, but for the "func Inactive" pseudo_signal.

ORE_LOWBATTERY directive
     Defines for Oregon sensors which transmit a battery level the percentage at
     or below which Heyu will raise the low-battery ("LoBat") flag.  The default
     is 20%.  Note that many Oregon sensor models transmit a low battery indica-
     tor rather than a battery level, and for these models this directive has no
     effect.
     Example:
       ORE_LOWBATTERY 10%

ORE_CHGBITS_T directive
ORE_CHGBITS_RH directive
ORE_CHGBITS_BP directive
     Define  for  Oregon Temperature, Relative Humidity, and Barometric Pressure
     sensors the difference between succesive data values required for the  data
     value  to be identified as "changed".  The parameter is the number of least
     counts for the data in question.  The default for each is 1.  See man  page
     x10oregon(5) for details.

ELS_CHGBITS_CURR directive
     Define for the Electrisave sensor the difference between successive current
     values required for the data to be identified as changed.	The parameter is
     the  number  of  least counts for the data.  The default is 1, which corre-
     sponds to 0.1 Ampere.  See man page x10oregon(5) for details.

OWL_CHGBITS_POWER directive
OWL_CHGBITS_ENERGY directive
     Define for the Owl CM119 sensor the difference between successive Power and
     Energy values for the data to be identified as changed.  The  parameter  is
     the  number of least counts for the data in question.  The default for each
     is 1, corresponding to 0.001kW and 0.0001kWh respectively.   See  man  page
     x10oregon(5) for details.

OWL_DISPLAY_COUNT directive
     Determines whether the raw data is displayed in the monitor/logfile for Owl
     CM119 sensors.  The parameter choises are YES or NO, with the default being
     NO.

ORE_DATA_ENTRY
     Defines whether data is entered in Oregon native or scaled units for Oregon
     sensor emulation.	The parameter choices are NATIVE or SCALED, with the de-
     fault  being  NATIVE.   See  section  "OREGON SENSOR EMULATION" in man page
     x10oregon(5) for details.

ORE_DISPLAY_CHAN directive
     Determines whether the channel number of an Oregon sensor is  displayed  in
     the  logfile, monitor, and 'heyu show oregon' table.  Setting the parameter
     of this directive to NO suppresses display of  the  channel  number,  while
     with the default YES the channel number is displayed.

ORE_DISPLAY_FCAST
     Determines  whether the "weather forecast" transmitted by Oregon Barometric
     Pressure sensors (currently module types ORE_THB1	and  ORE_THB2)	is  dis-
     played in the logfile, monitor, and in 'heyu show oregon'.  The choices are
     YES  or  NO,  with  the  default  being NO.  The displayed forecast will be
     "Sunny", "PtCloudy", "Cloudy" or "Rain".  The  algorithm  employed  in  the
     sensor  firmware  is  currenly unknown but is assumed to be related only to
     the value of and changes in BP.  (Indoor temperature and humidity data from
     a sensor rated only for indoor use can hardly have a bearing on  a  weather
     forecast.)

ORE_DISPLAY_COUNT directive
     Determines  whether  the  raw  data is displayed in the monitor/logfile for
     Oregon Wind and Rain sensors.  The parameter choises are YES  or  NO,  with
     the default being NO.

RFXCOM_DISABLE directive
     The  RFXCOM RF receiver hardware may be configured to suppress signals from
     specific sensor types to improve noise immunity and/or  to  ignore  foreign
     signals  from  nearby sensors.  Its use supercedes the directive RFXCOM_EN-
     ABLE, which is now obsolete since newer RFXCOM firmware  supports	a  wider
     variety of signal types.
     The syntax is:
       RFXCOM_DISABLE  <type> [<type> [<type> ...]]]

     The signal types which may be disabled are currently:
       OREGON
       ARCTECH
       ATIWONDER
       KOPPLA
       X10	(Standard and Security X10)
       HE_UK	(HomeEasy - UK and KAKU protocols)
       HE_EU	(HomeEasy - EU protocol)
       VISONIC	(Receivable only by RFXCOM VISONIC receivers.)

     All but HE_UK and HE_EU may be abbreviated to three characters.

     Examples:
       RFXCOM_DISABLE  OREGON
       RFXCOM_DISABLE  ORE  ARC  ATI

RFXCOM_ENABLE directive
     This is now obsolete.  See RFXCOM_DISABLE above.

	    ===============================================
     The  following  directives provide controls for Heyu's security system fea-
     tures.
	    ===============================================

ARM_MAX_DELAY directive
     When the 'heyu arm max ...' command is entered at the command line  or  re-
     ceived  from the RF auxiliary device, Heyu's security flag is initially set
     to "armpending".  At the end of the delay (in seconds)  specified	by  this
     directive,  the security flag is changed from "armpending" to "armed".  The
     following example specifies the delay to be 30 seconds:
       ARM_MAX_DELAY 30

     The default for this directive is 0 (zero), which sets the "armed" flag im-
     mediately regardless of the "max" or "min" parameter.

ARM_REMOTE directive
     This directive controls the behavior of Heyu when an 'arm'  signal  is  re-
     ceived  from  an  RF Security remote (source RCVA).  The allowed parameters
     are AUTO or MANUAL, with the default being AUTO.  If  set	to  MANUAL,  the
     signal  does not automatically set the global security flags, thus allowing
     the signal to be used to launch a script to customize the	arming	process,
     e.g.,  to first check that all doors and windows are closed and take an al-
     ternate action if they are not.  This directive has  no  effect  for  'arm'
     commands originating from the command line or other sources.

INACTIVE_TIMEOUT directive
     Most  security sensors transmit a signal with their current state (known as
     a "heatbeat") every 60-90 minutes to let the host system know they are  op-
     erational.
     RFXSensors  do  the same thing every 40 or 80 minutes, depending on whether
     hardware configured for fast or slow sampling.
     Oregon sensors transmit at intervals of 11 to  120  seconds,  depending  on
     model.

     Heyu  records  the times the signals are received.  The commands 'heyu sen-
     sorfault' and 'heyu show sensors' compare the elapsed times since the  last
     received  signals	with  the  value  specified with this directive to judge
     whether a sensor has become inactive.

     The value for this directive may be specifies in  seconds	or  in	hh:mm:ss
     format.  The default is 4:00:00 or 4 hours.  Example:
       INACTIVE_TIMEOUT  4:00:00

     This  directive  (or  its	default) can be overridden for a specific sensor
     having a heartbeat by appending the  parameters  "IATO   hh:mm:ss"  to  the
     ALIAS directive which maps that sensor to a Hu addresss.

INACTIVE_HANDLING directive.
     The  parameter  choice is NEW or OLD, with the default being NEW.	Choosing
     OLD reverts to the previous way Heyu handled the situation  when  a  sensor
     having  a	heartbeat failed to send a signal within the interval defined by
     the INACTIVE_TIMEOUT directive.  See man page x10scripts(5) for details.

ARM_LOGIC directive
     The value of this directive may be specified as STRICT, LOOSE,  or  MEDIUM.
     The default is MEDIUM.

     When  specified  as  STRICT, the state of the security flags may be changed
     from "disarmed" to "armed" or "armpending" and vice-versa, but  no  changes
     between  "armed" and "armpending" or between "home" and "away" are allowed.
     I.e., the system must be in the "disarmed" state before any 'heyu arm  ...'
     command can take effect.

     When  specified  as  LOOSE all changes are allowed.  A ramification is that
     the 'arm max ...' command when the system is already in the  "armed"  state
     will effectively disarm the system - put it in the "armpending" state - for
     the  duration  specified by the ARM_MAX_DELAY directive for as long as this
     command continues to be executed.

     When specified as MEDIUM, all changes are	allowed  except  the  transition
     from "armed" to "armpending".

     Example:
       ARM_LOGIC  MEDIUM

	    ===============================================
     The following experimental directives are otherwise undocumented and may or
     may not be useful for testing, hacking, or troubleshooting purposes.
	    ===============================================

CM11A_QUERY_DELAY directive
     On some systems a short delay appears to be required between a message from
     the  CM11A  that it has incoming powerline data and Heyu's polling for that
     data.  The parameter for this directive specifies the delay  time	in  mil-
     liseconds.   The  default is 0, indicating no delay.  Use of this directive
     may resolve the problem when Heyu reports: "The interface didn't  answer  a
     getinfo response." when attempting to receive incoming powerline data.
     Example:
       CM11A_QUERY_DELAY  10   # 10 millisecond delay

LOCK_TIMEOUT directive
     Before a Heyu process can write to the spool file it must first acquire the
     writefile	lock.	This  directive  specifies  how long a Heyu process will
     spend trying to acquire the lock before timing out and quitting.  Having  a
     number  of  Heyu  processes active at the same time and processes which hog
     the spool file, e.g., when sending commands to the CM11,  may  require  in-
     creasing  this  time.  The parameter for this directive is the time in sec-
     onds to spend, with the default being 10 seconds.
     Example:
	LOCK_TIMEOUT  20

DISPLAY_SENSOR_INTV directive
     Setting the parameter of this directive to YES instructs Heyu to append  to
     monitor/logfile  entries  for an Oregon or Security sensor the elapsed time
     interval in hh:mm:ss since the previous transmission from that sensor.

LOGDATE_UNIX directive
     This directive can be used to replace the normal date/time string displayed
     in the logfile and monitor with Unix time, i.e., seconds  from  the  1  Jan
     1970  epoch, to millisecond precision.  The parameter for this directive is
     YES or NO, with the default being NO.

ORE_ID_16 directive.
     Setting the parameter of this directive to YES expands the ID  code  of  an
     Oregon  sensor to 16-bit by using the channel code of the sensor as the up-
     per byte and the normal sensor ID as the lower byte.  The default is NO, to
     use only the normal sensor ID.

ENGINE_POLL directive
     This directive sets the delay in the polling loop of the  Heyu  Engine  and
     Heyu Monitor daemons. Too low a value results in somewhat excessive CPU us-
     age  when	idle.	The value is expressed in microseconds, with the default
     being 10000 (= 10 milliseconds).  The valid range is  100	to  1000000  mi-
     croseconds (1 second).
     Example:
	ENGINE_POLL 10000

RESTRICT_DIMS directive
     The  values for dim and bright levels for both Direct and Macro commands is
     specified in the X10 protocol as ranging from 1-22, however  the  field  in
     the binary command can accept a number between 0-31.  It is unknown at this
     time  whether  additional	dims/brights beyond 210 are actually sent by the
     CM11A, however the time for execution of the command  is  observed  to  in-
     crease  approximately proportionately.  Setting this directive to NO allows
     values between 0 and 31 to be programmed without generating an  error  mes-
     sage,  while taking the default of YES restricts the range to 1-22.  In any
     event, a CM11A receiving Dim or Bright signals over the AC power line never
     reports an expanded value greater than 210, which is actually reached  when
     the  programmed  level  is  19  or  greater.   (Entering  a  value of 0 for
     dim/bright level  for  my	CM11As	appears  to  send  the	same  number  of
     dims/brights as level 2, but who knows what yours will do.)

POWERFAIL_UPDATE directive
     When  AC  power resumes after an interruption, the CM11A will poll the com-
     puter with a constant stream of requests at one-second intervals for a time
     update and will accept no other command until  the  request  is  satisfied.
     The  Heyu	relay  by  default  automatically responds and updates the CM11A
     clock.  The choices for this directive are either YES or NO, with	the  de-
     fault being YES.  Choosing NO for this directive instructs the relay to re-
     spond  with  a truncated update which satisfies the CM11A but doesn't actu-
     ally reset the clock.  Note: If Heyu is already running, use 'heyu restart'
     for changes in this directive to become effective in the heyu_relay daemon.

     This directive allows the user to determine the accuracy of the CM11A clock
     when operating solely on battery power. E.g., run 'heyu  setclock'  to  set
     the  CM11A clock to the system clock, unplug the CM11A from the wall socket
     for several hours or a day, plug it back in and  run  'heyu  readclock'  to
     compare the CM11A and system clocks.

AUTO_WAIT directive
     This  directive  instructs  Heyu  to ping the CM11A before sending each X10
     command.  It has been reported that the USB port  on  some  non-PC  systems
     running  Linux  (toasters, maybe?) seem to need this nudge to wake them up.
     This directive takes a parameter 0 through  300  representing  the  maximum
     number  of pings (at one second intervals) to try before a ping response is
     received from the CM11A.  The default  is	0,  meaning  the  CM11A  is  not
     pinged.

ENVIRONMENT
     X10CONFIG	-  Points  to  a fully qualified file name of your configuration
     file, if located elsewhere than in one of the standard places.
     HEYUSUB - Optionally specifies an additional subdirectory level  under  the
     standard places where the configuration file will be found, i.e.,
	$HOME/.heyu/$HEYUSUB/
	/etc/heyu/$HEYUSUB/

AUTHORS
     Re-written to use the CM11A interface by Daniel B. Suthers (dbs@tanj.com).

     Originally  written  (Known  as  X10) by Larry Campbell (maynard!campbell).
     System V port, ID file, improved display formats, and other cleanup by John
     Chmielewski (rogue!jlc).  Module aliasing, sunset and sunrise additions  by
     Paul Fox (pgf@foxharp.boston.ma.us).  Additional functionality for uploaded
     timers   and  macros  and	for  scripts  by  Charles  W.  Sullivan  (cwsul-
     liv01@heyu.org)

SEE ALSO
     http://www.heyu.org
     date(1),  heyu(1), x10sched(5), x10scripts(5), x10cm17a(5), x10aux(5)

				      local			    X10CONFIG(5)