NAME
     x10oregon - Oregon sensor support for HEYU

DESCRIPTION
     Heyu  is  an X10 Automation program for Linux, Unix, and Mac OS X.  See man
     page heyu(1) for usage information.

     Oregon sensors transmit encoded RF signals for Temperature, Relative Humid-
     ity, Barometric Pressure, Wind speed, Rainfall, and other variables.   When
     equipped  with  a	compatible RF receiver, Heyu can receive and decode this
     information.  Also included in the same category are two miscellaneous sen-
     sors, the Electrisave CM113 and the OWL CM119, which transmit encoded  data
     from AC current probes in the breaker box.

SYSTEM REQUIREMENTS
     To  use  Oregon  sensors  with Heyu requires a 433.92 MHz RFXCOM X10 RF re-
     ceiver and Heyu version 2.3 or greater.  Support for the Electrisave  CM113
     was added in Heyu version 2.7.  Support for the OWL CM119 was added in Heyu
     version  2.8  but	also requires the special CM119 option in the RFXCOM re-
     ceiver.

COMPILER OPTION
     Support for Oregon sensors is compiled into Heyu by  default.   A	compiler
     option  can be used to omit this support.	See the file INSTALL included in
     the Heyu distribution source directory for details.

CONFIGURATION
     It is assumed that a working installation of Heyu version	2.3  or  greater
     exists  on  the  computer,  and  that the user has a basic familiarity with
     Heyu.

     Include the following directive in the Heyu configuration file:
       TTY_AUX	<serial_port or network_address:port>  RFXCOM
     where <serial_port> is the port where the RFXCOM receiver is connected,  or
     <network_address:port> is where the RFXLAN receiver is listening.	The RFX-
     COM  receiver  connects  to a USB port but includes a USB->Serial converter
     chip, while the RFXLAN connects over a network.

     Start Heyu with 'heyu start', then open another xterm window and run  'heyu
     monitor'  in  it  to start the Heyu Monitor.  Wait for the sensor to make a
     transmission, usually about every 40 seconds, and in the Heyu monitor  win-
     dow you should then see something like this (ignoring the date and time):

       rcva func   RFdata : Type ORE_TH1 Ch 1 ID 0x1F Data 0x1a2d101f6027908344

     The  example is for an Oregon Remote Temperature and Humidity sensor, which
     is in the group of Oregon sensors using  the  protocol  identified  by  the
     mnemonic ORE_TH1.

     Map  the  Oregon  ID  to an otherwise unused housecode and unitcode address
     with an ALIAS directive in your Heyu configuration file  using  the  module
     type  ORE_xxx corresponding to your sensor group.	(A list of Oregon sensor
     module types appears farther down in this page.)

     Syntax:
       ALIAS  <label>  <Housecode/Unit>  <module_type>	<ID>
     Example:
       ALIAS Attic  D5	ORE_TH1  0x1F

     Run 'heyu restart' to incorporate this change into the  running  Heyu  dae-
     mons.   Then  the	next time the sensor makes a transmission you should see
     (with the above example) something like this:

       rcva func  oreTemp : hu D5 Ch 1 Temp 27.7C (Attic)
       rcva func    oreRH : hu D5 Ch 1 RH 39% (Attic)

STORED OREGON DATA
     If the Heyu Engine daemon is running, current Oregon data is stored in  the
     Heyu state tables and displayed in the Heyu log file (if thus configured).

     Stored data can be retrieved with the (lower case) Heyu state commands cor-
     responding to the displayed function labels.  In the following, "Hu" is the
     Housecode|Unit address to which the sensor has been mapped in the ALIAS di-
     rective, or the alias label itself.
     Examples:
       heyu oretemp    Hu    - Temperature
       heyu orerh      Hu    - Relative Humidity
       heyu orebp      Hu    - Barometric Pressure

     The command 'heyu show oregon' will display stored data from all configured
     Oregon units in tabular form.

UNIT SCALING
     The  native units for output of Oregon sensors are Celsius for temperature,
     hPa (hectoPascals) for Barometric Pressure, and kilograms for Weight.  (See
     the sections WIND SENSORS and RAIN SENSORS for information about those sen-
     sors.)  These may be scaled by Heyu to different units with  the  following
     configuration file directives:

     Directive ORE_TSCALE  <temp_scale>

     where <temp_scale> is F[ahrenheit], C[elsius], K[elvin], or R[ankine].
     Example:
       ORE_TSCALE  F

     Directive ORE_BPSCALE <BP_unit> <scale_factor> [<offset>]

     where  <BP_unit> is the name of the new unit, e.g. mmHg, and <scale_factor>
     is the number by which the BP in hPa is multiplied to get its value in  the
     new unit.

     Directive ORE_WGTSCALE <Weight_unit> <scale_factor>

     where <Weight_unit> is the name of the new unit, e.g., Lbs, and <scale_fac-
     tor>  is  the  number by which the Weight in kilograms is multiplied to get
     its value in the new unit.
     Some examples:
       ORE_BPSCALE  mmHg  0.75006158
       ORE_BPSCALE  inHg  0.029529983 1.06
       ORE_BPSCALE  millibars  1.0
       ORE_WGTSCALE Lbs  2.200

     The optional <offset> parameter is added to the BP after scaling.

     In the USA at least, barometric pressures reported by the National  Weather
     Service are adjusted to the BP at sea level.  The offset can be used to ap-
     proximate this adjustment for altitude.  Typical values for BP versus alti-
     tude can be found on the Internet.

SUPPORTED OREGON MODEL NUMBERS
     The following chart shows the Oregon model numbers known to be supported by
     the Heyu ORE_xxx module types.

     Temperature sensors:
       ORE_T1 :  THR128 THR138 THC138
       ORE_T1 :  (THR128) Brookstone Projection Weather/Clock
       ORE_T2 :  THC238 THN132N THWR288A THRN122N THN122N AW129 AW131
       ORE_T2 :  Radio Shack P/N 63-1091 Projection Weather/Clock
       ORE_T3 :  THWR800 (Alpha)

     Temperature / Humidity sensors:
       ORE_TH1 : THGN122N THGN123N THGR122NX THGR228N THGR238 THGR268 THGR238N
       ORE_TH2 : THGR810 THGR800 THGN800
       ORE_TH3 : RTGR328N RTGN318
       ORE_TH4 : THGR328N
       ORE_TH5 : WTGR800
       ORE_TH6 : THGR918 THGR918N THGRN228NX

     Temperature / Humidity / Barometric Pressure sensors:
       ORE_THB1 : BTHR918  (Alpha)
       ORE_THB2 : BTHR918N BTHR968

     Weight sensors
       ORE_WGT1 : BWR101 BWR102

     Wind sensors
       ORE_WIND1 : WTGR800
       ORE_WIND2 : WGR800   (In Oregin model WMR80A Weather Station bundle)
       ORE_WIND3 : WGR918N  (In Oregin model WMR928N Weather Station bundle)

     Rain sensors
       ORE_RAIN1 : PCR918N  (In Oregon model WMR928N Weather Station bundle)
       ORE_RAIN2 : PCR800   (In Oregon model WMR80A Weather Station bundle)
       ORE_RAIN3 : (Alpha)

     UV sensors
       ORE_UV1 :  UVR138  (Alpha)
       ORE_UV2 :  UVN800  (Alpha)

     Current sensors
       ELS_ELEC1 : Electrisave CM113  (See note below.)
       OWL_ELEC2 : OWL CM119

     Module types designated "Alpha" have not yet been tested with actual data.

     Module  type  ORE_IGNORE  can be used to ignore signals from Oregon sensors
     which may not be under your control, e.g., signals from a nearby neighbor's
     sensor.  An unused Housecode/Unit address must be sacrificed.  Specify  the
     Oregon IDs for one or more sensors to be ignored.
     Example:
       ALIAS Neighbor_Sensors  P6  ORE_IGNORE  3C  4E  2A

     Note:  Use  of this module type does not prevent RF intereference with sig-
     nals from your own sensors.  See section MULTIPLE OREGON SENSORS below.

     Note: It's possible for the signal transmitted  from  an  ELS_ELEC1  sensor
     when  the "Check" button is pressed to be confused with that from an Oregon
     temperature sensor type ORE_T2. Pressing the Check  button  a  second  time
     will generally clear up the confusion.

     The  following module types are Oregon emulation (dummy) modules.	See sec-
     tion "OREGON SENSOR EMULATION" below for usage.  These modules do not  take
     an ID parameter.
       ORE_TEMU - Temperature
       ORE_THEMU - Temperature and Relative Humidity
       ORE_THBEMU - Temperature and Relative Humidity and Barometric Pressure.

TEMPERATURE, HUMIDITY, and BAROMETRIC PRESSURE SETPOINTS
     Temperature, Relative Humidity, and Barometric Pressure Min and/or Max set-
     points  can  be defined for any Oregon sensor by appending parameters "TMIN
     <setpoint>" and/or  "TMAX	<setpoint>"  and/or  "RHMIN  <setpoint>"  and/or
     "RHMAX  <setpoint>"  and/or  "BPMIN|BPMINL <setpoint>" and/or "BPMAX|BPMAXL
     <setpoint>" to the ALIAS directive line for that sensor in  the  configura-
     tion  file. When the data value reported by the sensor falls below or above
     the respective setpoint,  corresponding  local  flags  TMIN,  TMAX,  RHMIN,
     RHMAX, BPMIN, and BPMAX are raised which can be tested in the launch condi-
     tions for a Heyu script.
     Examples:
       ALIAS CrawlSpace B7  ORE_TH2 0x14  TMIN 32F RHMAX 90%
       ALIAS Attic  D5	ORE_T1	0x1F  TMAX 90F TMIN 60F

     Then  if  the  B7	sensor	reports  a crawl-space temperature lower than 32
     Fahrenheit, the TMIN flag will be raised. If the crawl-space  humidity  ex-
     ceeds  90%, the RHMAX flag will be raised.  And if the D5 sensor reports an
     attic temperature outside the range 60F - 90F, then the appropriate TMIN or
     TMAX flag will be raised.

     If the temperature scale suffix (C, F, K, or R) is omitted  from  the  set-
     point,  the  config  directive  "ORE_DATA_ENTRY  NATIVE|SCALED"  determines
     whether the scale is the native Celsius scale or that defined by  directive
     ORE_TSCALE.

     The only scale for relative humidity is %, which may optionally be omitted.

     The  barometric pressure scale defined by the ORE_BPSCALE directive may op-
     tionally include an offset to adjust for altitude.  If the specified Min or
     Max setpoint includes the offset, use BPMIN or BPMAX, otherwise use  BPMINL
     or  BPMAXL to specify that this is the unadjusted local pressure.	In other
     words, a setpoint specified by BPMIN corresponds to the adjusted value dis-
     played by Heyu, whereas a setpoint specified by BPMINL corresponds  to  the
     local value displayed on the sensor's LCD screen.

     A	BP  setpoint may include the suffix for the units defined in the ORE_BP-
     SCALE directive or the native units "hPa".  If the  setpoint  is  specified
     without a units suffix, the config directive "ORE_DATA_ENTRY NATIVE|SCALED"
     determines  whether the scale is the native "hPa" or that defined by direc-
     tive ORE_BPSCALE.

HEYU SCRIPTS
     Heyu scripts can be launched  by  the  functions  "oretemp",  "orerh",  and
     "orebp"  the  same  as  any  other Heyu function.	Similarly the "elscurr",
     "owlpower", and "owlenergy" functions from the current sensors
     The launch conditions in the SCRIPT directive must include the source  key-
     word "RCVA" and may optionally include the keyword "changed", any of the 16
     common  flags, and the global security flags.  They may also optionally in-
     clude the local flags.
     Examples:
       SCRIPT  L9 oretemp rcva armed away tmin :: my_oretemp.sh
       SCRIPT  L9 orerh changed rcva :: my_orerh.sh

     Local flags for the Oregon functions are "lobat" for  those  sensors  which
     transmit a low battery indicator, "tmin"/"tmax" for the "oretemp" function,
     "rhmin"/"rhmax"  for  the orerh function, and "bpmin"/"bpmax" for the orebp
     function.
     Example:
       SCRIPT CrawlSpace oretemp tmin :: echo "Freezing pipes" | mail

SCRIPT ENVIRONMENT
     Any Heyu script has access to the stored Oregon data values  through  envi-
     ronment  variables  linked  to  the housecode|unit (Hu) and its alias (note
     lower case x10_) mapped to each Oregon unit.
       X10_Hu_oreTemp	  x10_<Hu_alias>_oreTemp
       X10_Hu_oreBP	  x10_<Hu_alias>_oreBP
       X10_Hu_oreRH	  x10_<Hu_alias>_oreRH
       X10_Hu_oreLoBat	  x10_<Hu_alias>_oreLoBat (1 = Low, 0 = OK);
       X10_Hu_oreWgt	  x10_<Hu_alias>_oreWgt
       X10_Hu_oreWindSp   x10_<Hu_alias>_oreWindSp
       X10_Hu_oreWindAvSp x10_<Hu_alias>_oreWindAvSp
       X10_Hu_oreWindDir  x10_<Hu_alias>_oreWindDir
       X10_Hu_oreRainRate x10_<Hu_alias>_oreRainRate
       X10_Hu_oreRainTot  x10_<Hu_alias>_oreRainTot
       X10_Hu_elsCurr	  x10_<Hu_alias>_elsCurr
       X10_Hu_owlPower	  x10_<Hu_alias>_owlPower
       X10_Hu_owlEnergy   x10_<Hu_alias>_owlEnergy

     For sensor models which transmit this information:
       X10_Hu_oreCh	  x10_<Hu_alias>_oreCh	 (Channel number)
       X10_Hu_oreBatLvl   x10_<Hu_alias>_oreBatLvl
       X10_Hu_oreForecast x10_<Hu_alias>_oreForecast

     If a Heyu script is launched by one of the  functions  "oretemp",	"orerh",
     "orebp", "orewgt", "orewindsp", "orewindavsp", "orewinddir", "orerainrate",
     "oreraintot",  "elscurr",	"owlpower", or "owlenergy", the environment will
     additionally include variables for values and flags without the "Hu"  iden-
     tification, e.g., X10_oreTemp, X10_oreWgt, X10_elsCurr.

     No variable is created for data which is invalid or "not ready".

CONFIGURATION DIRECTIVES
     In  addition  to the ALIAS and scaling directives mentioned above, the fol-
     lowing will also affect Oregon data.  See man page x10config(5).

     Directive ORE_LOWBATTERY <percent> - Defines for those sensors which trans-
     mit a battery level the percentage at or below which Heyu	will  raise  the
     "LoBat" flag.  The default is 20%.

     Directive HIDE_UNCHANGED YES - Display transmission in the Monitor and Log-
     file only when there's a change from the previous transmission.

     Directives  ORE_CHGBITS_xx define the amount of change in the data required
     for it to be identified as "changed".  The parameter for  these  directives
     is  the  number  of  least significant bits for the data in question, which
     correspond to:
       ORE_CHGBITS_T   Temperature 0.1C
       ORE_CHGBITS_RH  Relative Humidity  1%
       ORE_CHGBITS_BP  Barometric Pressure  1hPa
       ORE_CHGBITS_WGT Weight  0.1kg
       ORE_CHGBITS_WINDSP Wind Speed  0.1meters/second
       ORE_CHGBITS_WINDAVSP Wind Average Speed 0.1meters/second
       ORE_CHGBITS_WINDDIR  Wind Direction  (varies with sensor model)
       ORE_CHGBITS_RAINRATE  Rainfall Rate (varies with sensor model)
       ORE_CHGBITS_RAINTOT   Total Rain (varies with sensor model)
       ORE_CHGBITS_UV  UV Factor  1

     (See the sections WIND SENSORS and RAIN SENSORS for  details  about  change
     bits for those sensor types.)

     Example:
       ORE_CHGBITS_T  2
     instructs	Heyu  to  report  a temperature as "changed" only when there's a
     difference of 0.2C or more from the previous value.  This avoids the situa-
     tion where even in a relatively constant temperature  environment	the  re-
     ported  temperature  may  flip-flop  back	and  forth by 0.1C in successive
     transmissions.

     The actual value of the data is stored in the Heyu state tables even though
     it's not identified as changed or displayed in the Monitor/Log file.

     The default for each of the above directives is 1.

     Directive ORE_DATA_ENTRY  NATIVE|SCALED
     Defines whether Oregon emulation data values (see	below)	are  entered  in
     Oregon  native units (Celsius for Temperature, percent for RH, or hectoPas-
     cals for BP) or in the scaled units defined by  directives  ORE_TSCALE  and
     ORE_BPSCALE.  This also applies to TMIN and TMAX setpoint temperatures when
     the entered temperature does not have a temperature scale suffix.

CURRENT SENSORS
     Heyu  supports decoding of signals from the Electrisave CM113 and the newer
     OWL CM119 current sensors when received by an RFXCOM receiver  in	variable
     length packet mode.

     When  Heyu  receives a signal from these sensors, you will see displayed in
     the monitor/logfile something similar to:
	rcva func   RFdata : Type ELS_ELEC1 Ch 1 ID 0xF5 Data 0x....
     or
	rcva func   RFdata : Type OWL_ELEC2 Ch 1 ID 0x24 Data 0x....

     Map the signal to a Housecode|init (Hu) with an ALIAS directive:
       ALIAS <label> <Hu> ELS_ELEC1 <ID>
     or
       ALIAS <label> <Hu> OWL_ELEC2 <ID>
     Example:
       ALIAS MyElectric  B6  OWL_ELEC2 0x24

     Directive ELS_VOLTAGE  <voltage>
     Defines a nominal AC voltage which is multiplied by the current reading  of
     an  Electrisave  sensor  to  display  a nominal power.  The default (or the
     value 0.0) omits displaying this power. Example:
       ELS_VOLTAGE  240.0
     Since the time relationship between current and  voltage  is  unknown,  the
     units of the displayed power are just "VA" (Volt-Amperes).  However this is
     probably  not  too  different  from Wattage for the typical residence which
     doesn't have large motors running.

     Directive ELS_CHGBITS_CURR
     Defines the amount of change in the Electrisave current required for it  to
     be  identified  as  "changed".   The parameter is the number of least bits,
     each corresponding to 0.1 Amperes.  The default is 1.

     The Electrisave CM113 sensor reports measured current (as func  "elsCurr"),
     whereas  the OWL CM119 sensor directly reports Power and total Energy usage
     computed internally in the sensor as functions "owlPower" and "owlEnergy".

     Directive OWL_VOLTAGE  <voltage>
     Defines a nominal AC voltage which corrects the computation  of  Power  and
     Energy  by  an  OWL CM119 sensor for nominal voltage other than the default
     230.0 Volts

     Directive OWL_CHGBITS_POWER  <nbits>
     Directive OWL_CHGBITS_ENERGY <nbits>
     Define the amount of change in the reported Power or Energy required for it
     to be identified as "changed".  The parameter is the number of least  bits,
     corresponding to 0.001 kW or 0.0001 KWh respectively.

     Directive OWL_CALIB_POWER	<factor>
     Directive OWL_CALIB_ENERGY <factor>
     Define  decimal  factors  by  which the Power and Energy values from an OWL
     sensor are multiplied by Heyu to get a better approximation of  the  actual
     Power  and  Energy.  Since the OWL sensor measures only current and the ac-
     tual AC voltage will usually vary from the nominal depending on time of day
     and day of the week, it can be useful to choose calibration factors to make
     the values reported by Heyu agree with the utility company  electric  meter
     when  compared  over a 24 hour or longer interval.  The default factors are
     1.0 for both directives.

     Directive OWL_DISPLAY_COUNT  YES|NO
     Determines whether the raw data count is displayed in  the  monitor/logfile
     for Owl CM119 sensors.  The default is NO.

     HEYU COMMANDS:

     The most recent values of current, power, or energy are stored in the state
     table and can be recovered with the commands:
       heyu elscurr <Hu>
       heyu owlpower <Hu>
       heyu owlenergy <Hu>

     HEYU ENVIRONMENT:

     Any  Heyu script can retrieve the Electrisave or Owl data via the following
     environment variables, where Hu is the Housecode|unit to which  the  sensor
     is mapped.
       X10_Hu_elsCurr	 x10_<Hu-alias>_elsCurr
       X10_Hu_owlPower	 x10_<Hu-alias>_owlPower
       X10_Hu_owlEnergy  x10_<Hu-alias>_owlEnergy

     Scripts  launched	by  one  of  the  sensor functions elscurr, owlpower, or
     owlenergy will also have  the  corresponding  environmental  variable  name
     without  the _Hu_, e.g., X10_owlPower.  Additionally available are the sig-
     nal counters which are decremented and cycled 9-0 (or 15-0  if  transmitted
     by pressing the check/test button).
       X10_elsSigCount
       X10_owlSigCount

WIND SENSORS
     There  are  currently three different protocols extant for Oregon Wind Sen-
     sors data: Wind1, Wind2, and Wind3.  These are identified by  "RFdata:Type"
     and decoded by the Heyu module types:
       ORE_WIND1
       ORE_WIND2
       ORE_WIND3

     Having  identified  the protocol and ID byte from the RFdata:Type displayed
     in the monitor/logfile, map the sensor to a housecode|unit address with  an
     ALIAS directive, e.g.,
       ALIAS MyWind  D3  ORE_WIND2  0x48

     Transmissions from wind sensors are single RF bursts and will be ignored if
     the <min_count> in directive AUX_REPCOUNTS is set greater than 1.

     The  main	difference between protocols insofar as the data is concerned is
     the wind direction.  The Wind1 and Wind2 sensors report  the  direction  as
     one  of  16 compass points 22.5 degrees apart, whereas Wind3 sensors report
     the direction as degrees 0-359 with a precision  of  1  degree.   Therefore
     each  bit specified with directive ORE_CHGBITS_WDIR will correspond to 22.5
     degrees for Wind1 and Wind2 or 1 degree for Wind3.

     Directive ORE_WINDDIR_MODE  DEGREES|POINTS|BOTH
     Instructs Heyu whether to display wind direction as  degrees  (0-359.9)  or
     compass points (e.g., N, NE, NNE, etc.) or both.  The default is BOTH.

     Directive ORE_WINDSCALE  <units_label>  <scale_factor>
     Converts  the  wind  sensor native units m/s (meters/second) into different
     units.  Some common examples (courtesy of the Unix 'units' program):
       ORE_WINDSCALE  mph  2.2369363
       ORE_WINDSCALE  kph  3.6
       ORE_WINDSCALE  furlongs/fortnight 6012.8848

     Directive ORE_WINDSENSOR_DIR  <degrees>
     Oregon's setup instructions call for the wind sensor to be mounted pointing
     due North.  If this is not possible, use this directive to define	the  di-
     rection  (+/-  0-359 degrees from due North) your sensor is actually point-
     ing.  This will correct the wind direction displayed by Heyu (although  not
     that displayed in a Oregon Weather Base Station).
     For  Wind1  and  Wind2 sensors, best results will be obtained if the sensor
     can be mounted pointing towards one of the 16 compass points.

     Directive ORE_DISPLAY_BEAUFORT  YES|NO
     In addition to the scaled wind speeds, the speeds on the (nonlinear)  Beau-
     fort scale (0-12) will be displayed in the monitor/logfile.  The default is
     NO.

     Directive ORE_DISPLAY_COUNT  YES|NO
     With  the parameter YES, the actual sensor data readings for wind speed and
     average speed are displayed in square brackets in the monitor/logfile.  The
     default is NO.

     Directive ORE_CHGBITS_WINDSP   <nbits>
     Directive ORE_CHGBITS_WINDAVSP <nbits>
     Directive ORE_CHGBITS_WINDDIR  <nbits>
     These directives define the amount of change in the variable  required  for
     it  to be marked as "changed", expressed as the number of least significant
     bits in the difference between successive values.
     For ORE_CHGBITS_WINDSP and ORE_CHGBITS_WINDAVSP, each  bit  corresponds  to
     0.1  meters/sec.	For ORE_CHGBITS_WINDDIR and Wind1 or Wind2 sensors, each
     bit corresponds to 1 compass point (22.5 deg),  while  for  Wind3	sensors,
     each bit corresponds to 1 degree.

     HEYU COMMANDS:

     The  lowercase functions orewindavsp, orewindsp, orewinddir can be executed
     as Heyu commands to recover the most recent data stored in the  Heyu  state
     tables.  Example:
       heyu orewindsp  E2

     The command 'heyu show oregon' displays the stored data for all Oregon sen-
     sors in tabular form.

     The command 'heyu show sensors' displays the Active/Inactive state and bat-
     tery  state  of  all  sensors along with the timestamp of the last received
     signal.

     HEYU SCRIPTS:

     The lowercase functions orewindavsp, orewindsp, and orewinddir can be  used
     in  a SCRIPT directive the same as any other Heyu function to launch a Heyu
     script.
     Example:
       SCRIPT E2 orewindsp rcva :: <my command line>

     Global flags and local flags "lobat" and "changed" can be included  in  the
     launch  conditions as required.  The source "rcva" must be included (unless
     it has been configured as a default source).

     HEYU ENVIRONMENT:

     Any Heyu script can retrieve the Wind data via  the  following  environment
     variables, where Hu is the Housecode|unit to which the sensor is mapped.
       X10_Hu_oreWindAvSp   x10_<Hu-alias>_oreWindAvSp
       X10_Hu_oreWindSp     x10_<Hu-alias>_oreWindSp
       X10_Hu_oreWindDir    x10_<Hu-alias>_oreWindDir

     Scripts  launched by one of the sensor functions orewindavsp, orewindsp, or
     orewinddir will also have the  corresponding  environmental  variable  name
     without the _Hu_, e.g., X10_oreWindSp

RAIN SENSORS
     There  are  currently three different protocols extant for Oregon Rain Sen-
     sors data: Rain1, Rain2, and Rain3.  These are identified by  "RFdata:Type"
     and decoded by the Heyu module types:
       ORE_RAIN1
       ORE_RAIN2
       ORE_RAIN3

     Having  identified  the protocol and ID byte from the RFdata:Type displayed
     in the monitor/logfile, map the sensor to a housecode|unit address with  an
     ALIAS directive, e.g.,
       ALIAS MyRain  D3  ORE_RAIN2  0x4E

     Transmissions from rain sensors are single RF bursts and will be ignored if
     the <min_count> in directive AUX_REPCOUNTS is set greater than 1.

     Mechanically, all the sensors work with a bucket arrangement. When a bucket
     is  filled  with a certain amount of rain water, it tips and dumps its con-
     tents and the tip is counted.

     The main difference between the protocols insofar as data is  concerned  is
     in  the native units.  For Rain1, the units are millimeters/hr and millime-
     ters with a precision of 1 millimeter(/hr). For Rain2 and Rain3, the  units
     are inches/hr and inches with a precision of 0.001 inch(/hr).

     What  somewhat  confuses  things is that for Rain2 at least, the total rain
     count is not incremented by the exact same  amount  for  each  tip  of  the
     bucket.   The  increments	39, 40, 43, 44 (i.e., 0.039, 0.040, 0.043, 0.044
     inches) appear in what seems to be a complex pattern which  is  yet  to  be
     comprehended.

     Directive ORE_RAINRATESCALE  <units_label>  <scale_factor>
     Directive ORE_RAINTOTSCALE  <units_label>	<scale_factor>
     By default the rainfall rate and total rainfall are displayed in the native
     units,  which  for the Rain1 protocol is mm(/hr) while for the others it is
     inches(/hr).  This directives allow display in any arbitrary units by  pro-
     viding  the  name	for  the  units and the scale factor by which the native
     units are multiplied to convert to the new units.	Some  common  units  and
     scale factors (courtesy of the Unix "units" program):
     For Rain1:
       ORE_RAINRATESCALE  inches/hr  0.039370079
       ORE_RAINTOTSCALE  inches  0.039370079
     For Rain2 or Rain3:
       ORE_RAINRATESCALE  mm/hr  25.4
       ORE_RAINTOTSCALE  mm  25.4

     Directive ORE_DISPLAY_COUNT  YES|NO
     With  the	parameter YES, the actual sensor data readings for rain rate and
     total rain are displayed in square brackets in  the  monitor/logfile.   The
     default is NO.

     Directive ORE_CHGBITS_RAINRATE  <nbits>
     Directive ORE_CHGBITS_RAINTOT  <nbits>
     These directives define the difference between the current and previous raw
     data  reading required for the data to be marked as "changed".  The default
     is 1 for both.
     For Rain1:
       ORE_CHGBITS_RAINRATE  <nbits>  (Each bit is 1 mm/hr)
       ORE_CHGBITS_RAINTOT   <nbits>  (Each bit is 1 bucket tip = 1 mm)
     For Rain2 or Rain3:
       ORE_CHGBITS_RAINRATE  <nbits>  (Each bit is 0.01 inch/hr)
       ORE_CHGBITS_RAINTOT   <nbits>  (Each bit is 1 bucket tip = 0.04 inch)

     FLAGS:

     Each sensor has a battery monitor.  For Rain2 and Rain3, a low-battery  in-
     dicator  is  transmitted and Heyu will display the LoBat flag with the data
     when it is received.
     For Rain1, the battery level 0-100% is transmitted (and by default is  dis-
     played  with the data).  The configuration directive ORE_LOWBATTERY defines
     the level (default 20%) at or below which the LoBat flag is raised and dis-
     played.

     When the total rain counter rolls over to zero, the Heyu "rollover" flag is
     raised and displayed.  For Rain2, rollover has been determined to occur af-
     ter an accumulation of 393.70 inches, which appears to be a strange  number
     until  the realization that it's equivalent to 10000 millimeters. The Rain1
     and Rain3 rollover points are assumed to be the same as for Rain2, but this
     has not been verified.

     HEYU COMMANDS:

     The lowercase functions orerainrate and oreraintot can be executed as  Heyu
     commands  to  recover the most recent data stored in the Heyu state tables.
     Example:
       heyu oreraintot	E2

     The command 'heyu show oregon' displays the stored data for all Oregon sen-
     sors in tabular form.

     The command 'heyu show sensors' displays the Active/Inactive state and bat-
     tery state of all sensors along with the timestamp  of  the  last	received
     signal.

     HEYU SCRIPTS:

     The  lowercase functions orerainrate and oreraintot can be used in a SCRIPT
     directive the same as any other Heyu function to launch a Heyu script.
     Example:
       SCRIPT E2 oreraintot rcva :: <my command line>

     Global flags and local flags "lobat" and "changed" can be included  in  the
     launch  conditions as required.  The source "rcva" must be included (unless
     it has been configured as a default source).

     HEYU ENVIRONMENT:

     Any Heyu script can retrieve the Wind data via  the  following  environment
     variables, where Hu is the Housecode|unit to which the sensor is mapped.
       X10_Hu_oreRainRate   x10_<Hu-alias>_oreRainRate
       X10_Hu_oreRainTot    x10_<Hu-alias>_oreRainTot

     Scripts launched by one of the sensor functions orerainrate oreraintot will
     also  have  the corresponding environmental variable name without the _Hu_,
     e.g., X10_oreRainRate

APPLICABLE OLDER DIRECTIVES for WIND and RAIN sensors.
     Directive HIDE_UNCHANGED  YES|NO
     Determines whether unchanged data signals are displayed in the  Heyu  moni-
     tor/logfile.

     Directive INACTIVE_TIMEOUT  <hh:mm:ss>
     Any sensor with a heartbeat will be reported as Inactive if no signals have
     been received from it within the specified timeout (default is 4 hours).

     Directive ORE_DISPLAY_BATLVL  YES|NO
     Determines  whether  the  battery	level  0-100%  is displayed in the moni-
     tor/logfile for those sensor models which report a battery level as opposed
     to just a low-battery flag.  The default is YES.  The LoBat flag  is  unaf-
     fected  by  this  directive.   (The  battery  level  defined with directive
     ORE_LOWBATTERY defines the level at or below which the LoBat flag	will  be
     raised.)

     Directive ORE_DISPLAY_CHAN  YES|NO
     Determines  whether  the  Oregon  channel	number is displayed in the moni-
     tor/logfile.  (The Wind and Rain sensors have no channel and  are	assigned
     by Heyu to be Channel 1.)	The default is YES.

     Directive DISPLAY_SENSOR_INTV  YES|NO
     Determines  whether  the time elapsed between the current and previous sig-
     nals is displayed in the monitor/logfile.	The default is NO.

OREGON SENSOR EMULATION
     An external program can store Temp/RH/BP data in the state table for an em-
     ulation (dummy) Oregon module for processing by Heyu, just as if  the  data
     were  received  from an actual Oregon sensor.  The available emulation mod-
     ules (described previously) are ORE_TEMU, ORE_THEMU, and  ORE_THBEMU  which
     are  mapped to a housecode|unit address with an ALIAS directive, similar to
     an actual Oregon sensor.

     To store data, use the command:
	heyu ore_emu  Hu  <func>  <value>

     where:
       Hu is the address to which one of the  following  emulation  modules  has
     been mapped with an ALIAS configuration directive, or its alias label.
       <func> is 'oretemp', 'orerh', or 'orebp'.
       <value> is the numerical value of the Temperature, RH, or BP data.
       (Temperature may optionally have an appended scale suffix C, F, K, or R.)

     The  configuration  directive  ORE_DATA_ENTRY determines the units in which
     Heyu expects the data values to be entered, unless for Temperature  it  has
     been overridden by a scale suffix.
     With the default "ORE_DATA_ENTRY NATIVE", the data is entered in the native
     units  for  Oregon  sensors, i.e., Celsius for Temperature, percent for RH,
     and hectoPascals (hPa) for BP.
     With "ORE_DATA_ENTRY  SCALED", data is entered in the units defined by con-
     figuration directives ORE_TSCALE and ORE_BPSCALE.	Note that with unit con-
     version and rounding between scaled and native units, the	displayed  value
     of the scaled data may be slightly different than what is entered.

     Entered BP data is expected to be the local value, without the offset (typ-
     ically  for  adjustment  to  sea  level) which is optionally specified with
     ORE_BPSCALE.  (The offset is applied to the value displayed in the  monitor
     or  log  file  and  to  the  Heyu	environment  variables	when a script is
     launched.)

     Example:
     In the Heyu config file:
       ALIAS  basement	D4  ORE_THEMU
       ORE_DATA_ENTRY  SCALED
       ORE_TSCALE F

     At the command prompt:
       heyu ore_emu  basement oretemp  65.0
       heyu ore_emu  basement orerh  50

     The signal will appear in the logfile and monitor with source SNDC.  Remem-
     ber to include this in the launch conditions if the signal is  expected  to
     launch a Heyu script.

MULTIPLE OREGON SENSORS
     If  multiple Oregon sensors are to be used, they should be different models
     and/or set to different channel numbers so each has a  different  transmis-
     sion  interval (and not an interval which is an integer multiple of another
     interval).  Not doing so risks having "blackout" periods during  which  the
     RF signals from two or more sensors with the same transmission interval in-
     terfere with each other over an extended period of time.

     The transmission interval for Oregon sensors is typically 30, 40 or 60 sec-
     onds offset by an interval depending on the channel number.  E.g., here are
     the  nominal intervals in seconds for several Oregon models.  (Users owning
     other models are encouraged to submit the information for those  models  so
     we can expand this table.)

       Model	  ORE_	Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6 Ch 7 Ch 8 Ch 9 Ch 10
       -----	  ----	---- ---- ---- ---- ---- ---- ---- ---- ---- ----
       THR138	  T1	 30   29   31
       THRN122N   T2	 78
       THN122N	  T2	 39   41   43
       THN132N	  T2	 39   41   43
       THGR122NX  TH1	 39   41   43
       THGN123N   TH1	 39   41   43
       THGR228N   TH1	 39   41   43
       THGR238	  TH1	 ??   ??   ??
       THGR238N   TH1	 39   41   43
       THGR810	  TH2	 53   59   61	67   71   79   83   87	 91   93
       THGR800	  TH2	 53   59   61
       THGN800	  TH2	 53   59   61		  (WMR80A Weather Station)
       RTGN318	  TH3	 53   59   61	67   71   (BAR800 Weather Station)
       RTGR328N   TH3	 53   59   61	67   71
       THGR328N   TH4	 53   59   61	67   71
       THGR918N   TH6	 37			  (WMR968N Weather Station)
       BTHR968	  THB2	 38
       BTHR918N   THB2	 38

     Rebranded Units:
       GEONAUTE   T2	 78	       (Geonaute WS-300 Weather Station)
       63-1091	  T2	 39   41   43  (Radio Shack Proj Weather/Clock)
       n/a	  T1	 30   29   31  (Brookstone Proj Weather/Clock)

     Weather sensors:
       PCR800	  RAIN2  47	       (WMR80A Weather Station)
       WGR800	  WIND2  14	       (WMR80A Weather Station)
       PCR918N	  RAIN1  47	       (WMR968N Weather Station)
       WGR918N	  WIND3  14	       (WMR968N Weather Station)

     Current sensors:
       CM113  ELS_ELEC1   6	       (Electrisave cent-a-meter)

     The   STR928N   Solar  Panel  houses  the	transmitters  for  both  PCR918N
     (ORE_RAIN1) and THGR918N (ORE_TH6) sensors within the panel housing.
     The STR938 Solar Panel housing  houses  the  transmitter  for  the  WGR918N
     (WIND3) anemometer.

     The  length  of an Oregon RF transmission depends on the type, but is some-
     where around 150-400 milliseconds.

     With two THR138 sensors set to channels 1 and 2 respectively, one might ex-
     pect that the two sensors would transmit at the same time	_at  most_  once
     every (30 * 29) = 870 seconds.  The most likely result of an overlap of the
     RF  transmissions is that the RFXCOM receiver will not recognize the signal
     as a valid Oregon signal and remain silent, but losing one out of every  30
     transmissions is normally not that serious a problem.

     However consider the case of two sensors with the same nominal transmission
     interval.	Each Oregon sensor has an independent timebase and the transmis-
     sion  intervals  will be slightly different.  The two sensors may run for a
     long time without the transmissions overlapping, but  one	will  eventually
     catch up with the other.  Suppose the intervals of two sensors differ by 10
     milliseconds.   Then  when  the  catchup occurs, the RF signal overlap will
     last for approximately (3 * 150) = 450 milliseconds divided by 10 millisec-
     onds, or 45 intervals of 30 seconds - a blackout period of about 22 minutes
     when no signal will be reported.  The smaller the difference between sensor
     intervals, the longer the blackout period will last.

     If you are forced to run more than one sensor with the same nominal  trans-
     mission  interval,  a  more precise measurement of the each interval can be
     obtained from the Heyu monitor by putting the directive "LOGDATE_UNIX  YES"
     in the configuration file.

     An extended blackout longer than the time set  by	configuration  directive
     INACTIVE_TIMEOUT (default 4 hours) will generate an Inactive message in the
     monitor/logfile.

     Although Heyu can be instructed to ignore signals from a neighbor's sensors
     by using the ORE_IGNORE module type, those signals can still interfere with
     signals  from your own sensors and result in a blackout if the transmission
     intervals are the same.

SPECIAL BWR102 SETUP
     The Oregon BWR102 scale has a switch on the scale for  units  kg,	lbs,  or
     stone-lbs,  but  this  controls  only  the display on the scale's LCD.  The
     transmitted data is always in kg.	Use the config directive ORE_WGTSCALE to
     define the units for Heyu's display.

     Oregon appears to use the scale factor 2.200 for conversion from kg to  lbs
     rather  than  the	official value 2.2046226.  However neither of these pro-
     duces an exact match to the BWR102 LCD display for weights below  about  50
     lbs.

     The  BWR102 transmits data as follows: After stepping on the scale and dis-
     playing the measurement, the scale retransmits the data up to  seven  times
     at  approximately	10 or 11 second intervals (for use by the remote display
     unit provided with the scale).  Heyu sets the 'changed' flag for the  first
     of  these	regardless of whether the weight in this measurement is the same
     or different as the previous measurement, i.e., if you step  on  the  scale
     twice in a row and get the exact same reading (which is unusual), Heyu will
     still record the weight as changed.

     Note:  Transmissions  from  the BWR102 are single RF bursts and will be ig-
     nored if the <min_count> in directive AUX_REPCOUNTS is set greater than 1.

EXPERIMENTAL STUFF
     Directive "ORE_ID_16  YES" expands the ID of Oregon sensors  to  16-bit  by
     using the channel code as the upper byte of a 16-bit ID word and the normal
     sensor-assigned  ID as the lower byte.  This may be useful if you have some
     of the Oregon sensor models which can only generate a very  limited  number
     of different IDs.

     Heyu  recognizes  protocols  for Oregon signals beyond those listed as sup-
     ported, but by default ignores them.

     Directive DISPLAY_ORE_ALL	YES - Instructs Heyu to display "RFdata" signals
     with all recognized Oregon protocols even though the support  may	not  yet
     exist for them in Heyu.  Recognized but unsupported protocols are:

       ORE_DT1 - Real time clock/calendar.
       ORE_WGT2 - Weight

AUTHORS
     Oregon support was added to Heyu by Charles W. Sullivan using the protocols
     gratefully provided by RFXCOM.

SEE ALSO
     http://www.heyu.org
     heyu(1),  x10config(5), x10sched(5), x10scripts(5), x10aux(5), x10cm17a(5),
     x10rfxsensors(5), x10rfxmeters(5), x10digimax(5)

				      local			    X10OREGON(5)